• Title/Summary/Keyword: air monitoring

Search Result 1,514, Processing Time 0.026 seconds

Monitoring and Control of the Air Spindle Based Microdrilling Using Spindle Speed Variations (주축속도변동을 이용한 공기회전축식 미세구멍가공의 감시제어)

  • 안중환;김화영;이응숙;오정욱
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.5
    • /
    • pp.1176-1181
    • /
    • 1995
  • Microdrilling is one of the most difficult operations because of the poor chip discharge and the weakness of tool. This study is concerned about the development of a microdrilling monitoring system that is useful for minimizing the tool breakage and enhancing the machinability in the air spindle based microdrilling. The system is composed of a drilling state detection unit and an adaptive step-feed control unit that controls the micro-stepping motor driven spindle axis. Drilling states such as overload, tood breakage are recognized by the change of the air spindle speed which is measured via the reflective photo sensor. Based on the monitoring results, the adaptive step-feed control algorithm adjusts the step increment to keep the decrease of spindle speed within a specified range. The results of evaluation tests have shown that the developed system is very effective to prevent the breakage of microdrill and improves the productivity in comparison with the conventional microdrilling.

MODIS AEROSOL RETRIEVAL IN FINE SPATIAL RESOLUTION FOR LOCAL AND URBAN SCALE AIR QUALITY MONITORING APPLICATIONS

  • Lee, Kwon-Ho;Kim, Young-Joon
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.378-380
    • /
    • 2005
  • Remote sensing of atmospheric aerosol using MODIS satellite data has been proven to be very useful in global/regional scale aerosol monitoring. Due to their large spatial resolution of $10km^2$ MODIS aerosol optical thickness (AOT) data have limitations for local/urban scale aerosol monitoring applications. Modified Bremen Aerosol Retrieval (BAER) algorithm developed by von Hoyningen-Huene et al. (2003) and Lee et al. (2005) has been applied in this study to retrieve AOT in fe resolutions of $500m^2$ over Korea. Look up tables (LUTs) were constructed from the aerosol properties based on sun-photometer observation and radiation transfer model calculations. It was found that relative error between the satellite products and the ground observations was within about $15\%$. Resulting AOT products were correlated with surface PMIO concentration data. There was good correlation between MODIS AOT and surface PM concentration under certain atmospheric conditions, which supports the feasibility of using the high-resolution MODIS AOT for local and urban scale air quality monitoring

  • PDF

Status Analysis for the Confinement Monitoring Technology of PWR Spent Nuclear Fuel Dry Storage System (경수로 사용후핵연료 건식저장시스템의 격납감시 기술현황 분석)

  • Baeg, Chang-Yeal;Cho, Chun-Hyung
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.14 no.1
    • /
    • pp.35-44
    • /
    • 2016
  • Leading national R&D project to design a PWR spent nuclear fuel interim dry storage system that has been under development since mid-2009, which consists of a dual purpose metal cask and concrete storage cask. To ensure the safe operation of dry storage systems in foreign countries, major confinement monitoring techniques currently consist of pressure and temperature measurement. In the case of a dual purpose metal cask, a pressure sensor is installed in the interspace of bolted double lid(primary and secondary lid) in order to measure pressure. A concrete storage cask is a canister based system made of double/redundant welded lid to ensure confinement integrity. For this reason, confinement monitoring method is real time temperature measurement by thermocouple placed in the air flow(air intake and exit) of the concrete structure(over pack and module). The use of various monitoring technologies and operating experiences for the interim dry storage system over the last decades in foreign countries were analyzed. On the basis of the analysis above, development of the confinement monitoring technology that can be used optimally in our system will be available in the near future.

Computation of geographic variables for air pollution prediction models in South Korea

  • Eum, Youngseob;Song, Insang;Kim, Hwan-Cheol;Leem, Jong-Han;Kim, Sun-Young
    • Environmental Analysis Health and Toxicology
    • /
    • v.30
    • /
    • pp.10.1-10.14
    • /
    • 2015
  • Recent cohort studies have relied on exposure prediction models to estimate individual-level air pollution concentrations because individual air pollution measurements are not available for cohort locations. For such prediction models, geographic variables related to pollution sources are important inputs. We demonstrated the computation process of geographic variables mostly recorded in 2010 at regulatory air pollution monitoring sites in South Korea. On the basis of previous studies, we finalized a list of 313 geographic variables related to air pollution sources in eight categories including traffic, demographic characteristics, land use, transportation facilities, physical geography, emissions, vegetation, and altitude. We then obtained data from different sources such as the Statistics Geographic Information Service and Korean Transport Database. After integrating all available data to a single database by matching coordinate systems and converting non-spatial data to spatial data, we computed geographic variables at 294 regulatory monitoring sites in South Korea. The data integration and variable computation were performed by using ArcGIS version 10.2 (ESRI Inc., Redlands, CA, USA). For traffic, we computed the distances to the nearest roads and the sums of road lengths within different sizes of circular buffers. In addition, we calculated the numbers of residents, households, housing buildings, companies, and employees within the buffers. The percentages of areas for different types of land use compared to total areas were calculated within the buffers. For transportation facilities and physical geography, we computed the distances to the closest public transportation depots and the boundary lines. The vegetation index and altitude were estimated at a given location by using satellite data. The summary statistics of geographic variables in Seoul across monitoring sites showed different patterns between urban background and urban roadside sites. This study provided practical knowledge on the computation process of geographic variables in South Korea, which will improve air pollution prediction models and contribute to subsequent health analyses.

Preliminary Survey for the Design of the Air Pollution Monitoring System in Antarctic Area (남극지역의 대기오염 측정체계 구축을 위한 기초조사)

  • 김선태;홍성민;정의석;김성근
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2000.11a
    • /
    • pp.65-66
    • /
    • 2000
  • 남극은 지리적인 원거리성과 혹독한 자연환경 등으로 문명에 의한 오염이 지구상에서 가장 적은 곳이며, 현재 우리가 거주하고 있는 각 대륙을 이해하는데 많은 기여를 하고 있다고 할 수 있다. 특히, 남극대륙을 대상으로 기상 및 기후학적인 관점에서 많은 연구가 수행되어 지고 있으며, 최근에는 지구온난화와 문제와 관련하여 남극대륙의 배경농도 측정 및 monitoring에 관심이 집중되고 있다. (중략)

  • PDF

Studies on the Variation of the Ozone Precursors using On-Line Air Monitoring System (ON-line System을 이용한 오존 Precursor의 거동에 대한 연구)

  • 조석주;윤중섭;여인학;이민환;김민영;김신도
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2002.04a
    • /
    • pp.251-252
    • /
    • 2002
  • 최근 서울시보건환경연구원에서는 국내 최초로 미국의 PAMS(Photochemical Assessment Monitoring Systems) 측정망을 응용한 VOCs 측정망을 구축하여 대기 중 탄화수소를 포함하는 휘발성유기화합물를 측정 운영 중에 있다. VOCs는 그 종류와 발생원이 복잡 다양할 뿐만 아니라 시료의 채집과 분석방법에 여러 가지 기술적인 어려움이 내재한다. (중략)

  • PDF

Chemiluminescence System with Air Pump as a Sensor for Determination of Metal Levels in Rain

  • Hong, Hyuck-Gi;Lim, H.B.
    • Bulletin of the Korean Chemical Society
    • /
    • v.26 no.12
    • /
    • pp.1937-1940
    • /
    • 2005
  • A lab-made chemiluminescence system with air pump was developed for monitoring of some metal levels in rain. The air pump enabled injection of 17.7 $\mu$g samples into a glass cell filled with luminol-$H_2O_2$ reagent of typically 300 $\mu$L for chemiluminescence measurement. The monitored trend of total metal ions in the rain collected in our campus was compared with analytical results of each metal ion from GFAAS. The system was also demonstrated to determine $Cr^{6+}$ by reduction to $Cr^{3+}$ using $SnCl_2$. The limit of detection for $Cr^{6+}$ obtained by 4 measurements was 85.0 pg $mL^{-1}$ with a relative standard deviation of 3.4%. Although this system doesn’t have selectivity due to the characteristics of chemiluminescence, application of it to environmental monitoring as a sensor for some transition metal ions was demonstrated.

On the Diurnal Variations of CO and $CO_2$ in the Underground Atmospheric Environments (지하대기중의 CO 및 $CO_2$의 일변화 특성에 관한 연구)

  • 이동인;이지연
    • Journal of Environmental Science International
    • /
    • v.3 no.4
    • /
    • pp.381-391
    • /
    • 1994
  • This paper presents the disributions and variations of CO, $CO_2$, number of people and temperature in underground shopping center and subway of Seomyeon and Jagalchi in Pusan, Korea for two times during October and November in 1993, respectively. NDIR analyzer is used for the analysis of CO and $CO_2$. The temperature is obtained from a mercury therometer. The results o( observation and analysis show that the variation of $CO_2$ is strongly related to number of people and temperature. The correlation coefficients between temperature, COB and Number of people are higher than 0. at both of places. The pollution of CO2 of Seomyeon is higher than that of Jagachi in underground shopping center. However, CO is not correlated with the temperature and the Number of people. From the results, we found that the indoor air quality monitoring system is needed for the prevention of the underground air Pollution.

  • PDF

Air Quality Measurements and QC/QA (II) -Current Status and Future Requirements (대기환경측정과 정도관리(II)-국내 현황과 향후 과제)

  • Baek Sung-Ok;Heo Gwi-Suk;Kim Ki-Hyun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.2
    • /
    • pp.251-261
    • /
    • 2004
  • In this article, an in-depth review is presented to explain the present status of QC and QA for air quality monitoring, especially with respect to a few pollutants of which measurement requires high standard such as VOC and heavy metals. Upon reviewing the reported results of various studies conducted previously, we attempted to suggest a future direction of QC and QA for the acquisition of the high quality data in the air quality monitoring.

Development of On-Line Monitoring System for Pumped Storage Generator/Motor (양수발전소 발전-전동기 운전중 감시 시스템의 개발)

  • 김희동;주영호
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.3
    • /
    • pp.168-174
    • /
    • 2004
  • On-line monitoring system(OMS) has been developed for the pumped storage generator/motor The OMS is applied to diagnosis of the PD(partial discharge) activity of stator insulation, the shorted-turn of rotor winding and the variation of the air-gap between stator and rotor. The OMS consists of DAS(data acquisition system), main server system, gateway and display PC. The DAS measures the PD, the shorted-turn and air-gap from three sensors installed on the generator/motor. The gateway controls the data which sent by DAS. The main server system saves the data, analyzes the data and conducts the diagnostic algorithm. The display PC shows the diagnostic results of partial discharge, shorted-turn and air-gap. Field tests were conducted using PDA(partial discharge analyzer). The results of the OMS and PDA measurements can be directly correlated with normalized quantity number(NQN), PD magnitude(Qm) and PD pattern.