• 제목/요약/키워드: air meter method

검색결과 70건 처리시간 0.026초

가솔린 엔진의 비정상 상태에 대한 Map 구성과 공기 및 연료 모델 개선 (Construction of Map for Transient Condition of a Sl Engine and Refinement of Intake Air Model & Fuel Model)

  • 심연섭;강태성;강승표;고상근
    • 한국자동차공학회논문집
    • /
    • 제10권5호
    • /
    • pp.1-8
    • /
    • 2002
  • For gasoline engines, a three-way catalytic converter that has the maximum efficiency at stoichiometric air/fuel ratio is used to clean up the exhaust gas. So a precise air/fuel ratio control is necessary to maximize the catalytic conversion efficiency, For a transient condition, a fred-forward air/fuel ratio control method that estimates the air mass inducted into a cylinder is being used. In this study, a fuel injection map that makes an accurate air/fuel ratio control possible was constructed for the very same transient condition. For the same condition above, intake air model and fuel model were refined so that fuel injection values based on air mass through a throttle valve and intake manifold pressure are equal to the map values.

교통체계개선에 의한 화물교통 대기오염영향 저감방안 - 시흥시 시화국가산업단지를 중심으로 - (Comparative Study of Truck Traffic System Management for Reducing Air Pollution Impact - Forcusing on Sihwa National Industrail Complex, Siheung City -)

  • 이희관;김형철;권우택
    • 환경영향평가
    • /
    • 제15권1호
    • /
    • pp.23-33
    • /
    • 2006
  • The factor of air pollution in a large industrial city is not only manufactories but also, activities related to trucks. Sihwa National Industrial Complex is located in Siheung City; due to the industries, more diverse activities related to trucks occur in Siheung City than other cities. In particular, the new residential area in Siheung City is close to the industrial complex; so, the damage of this residential area is expected that it would be more serious and vulnerable than other areas. The aim of this study is to analyze influence of the air pollution by a truck in Siheung City. ISCST3 Model and Arc View program were used for this study and Siheung City was divided into 1,000 meter by 1,000 meter grid to analyze. Furthermore, this study suggested two reduction controls of air pollution in Siheung City, and analyzed the results from these reduction managements. The results of the present condition showed that residences located in north of Sihwa Industrial Complex are influenced by air pollution material. Furthermore, air pollution by trucks has affected on the residents which is near the road in Siheung City. Therefore, this study suggested two reduction controls by the Traffic System Management. The first alternative plan is setting the truck traffic limitation zone in the road that is located in south of resident areas and many trucks traffic. Next, the second alternative plan is setting freight truck way on the most traffic road to enter the industrial complex. The reduction effect of the first alternative is good on the residential area. And, the second alternate about freight truck way is divided passenger cars into trucks. Therefore, there are increase of average speed and decrease of average concentration, and spatial reduction effects found in wide areas.

흉수의 pH 측정에서 혈액가스분석기계, pH meter, pH Strip 방법의 비교 (Comparision of Blood Gas Analyser, pH Meter and pH Strip Methods in the Measurement of Pleural Fluid pH)

  • 지현석;박용범;최재철;안창혁;유지훈;김재열;박인원;최병휘
    • Tuberculosis and Respiratory Diseases
    • /
    • 제48권5호
    • /
    • pp.773-780
    • /
    • 2000
  • 연구배경 : 흉수의 pH 측정은 흉막천자시 흉수의 원인 진단을 위해 시행되는 중요한 검사항목이며, 특히 부폐렴흉막염이 농흉화되는지를 확인할 수 있는 지표중 하나이다. 흉수의 pH 측정은 혈액가스분석기계를 이용하는 것이 표준이나, 상황에 따라서는 pH meter나 pH strip을 이용하기도 한다. 본 연구에서는 흉수중 삼출액을 대상으로 위의 세가지 방법으로 pH를 측정하고 측정치들을 비교하여 보았다. 방법 : 1999년 8월부터 2000년 3월까지 중앙대학교 부속 용산의료원에 입원하여 삼출성 흉수로 의심되어 흉막 천자를 시행한 34례 (결핵성 흉막염 16명, 부폐렴성 흉수 9명, 폐암 5명, 농흉 3명, 심부전 1명)의 흉수에서 혈액가스분석기계, pH meter, pH strip의 세 가지 방법으로 pH를 측정하였다. 혈액가스분석기계와 pH meter에 의한 측정은 천자후 $0^{circ}C$로 유지하면서 30분 내에 시행하였으며, pH strip 측정은 흉막천자 직후에 pH strip으로 pH를 측정하고, 상온 상태로 검사실에 내려서 보고되는 결과를 이용하였다. 결과 : 34례 흉수의 pH 값 (평균값$\pm$표준편차)은 혈액가스 분석법 7.34$\pm$0.12, pH meter 법 7.52$\pm$0.25, pH strip 법 중, 흉막천자후 즉시검사의 경우에는 7.37$\pm$0.16 였으며, 검사실에서 측정한 pH strip법은 6.93$\pm$0.20으로, 혈액가스분석법을 기준으로 한 평균치 분석에서 검사실에서 측정한 pH strip 법은 의미있는 차이를 보였다(p<0.05). 혈액가스분석법과 pH meter 방법, 그리고 혈액가스 분석법과 천자직후 pH strip법의 사이에는 의미있는 상관관계가 있었고, 혈액가스분석법과 pH strip 법 사이에는 의미있는 상관관계가 없었다. 결론 : 흉수천자 직후에 측정한 pH strip 법은 비교적 간단하고 정확하게 흉수의 pH를 측정할 수 있을 것으로 판단된다.

  • PDF

적외선 열화상을 이용한 건축외장재의 일사표면온도와 흡수율 추정에 관한 실험적 연구 (An Experimental Study on the Estimation of Sol-air Temperature and Absorptance in Building Exterior Materials by Using the Infrared Image)

  • 박사근;장길수;송민정;신 훈
    • KIEAE Journal
    • /
    • 제6권4호
    • /
    • pp.33-39
    • /
    • 2006
  • This study aims to investigate the method to reduce the surface temperature caused by insolation. To achieve this goal, surface temperature of building is measured and the effects of exterior material's color and brilliance were checked with infrared imaging. And also, exterior material's absorptances due to outdoor surface heat transfer coefficients were measured. After surface temperature measurement of 37 specimen of 5 categories, the temperature is the highest on wood($53.62^{\circ}C$) and panel($52.05^{\circ}C$). Dryvit, stone, brick is the rating of order. For exterior material's absorptances, panel(0.883) and wood(0.868) were high and Dryvit, stone, brick follows wood and panel.

곡물건조저장법 개선을 위한 농가용 Grain Bin에 관한 연구 (Study on the Small Grain Bin for the Improvement of Grain Drying and Storage)

  • 김성래
    • 한국농공학회지
    • /
    • 제16권1호
    • /
    • pp.3263-3291
    • /
    • 1974
  • Experimental work of grain bin was carried out to develop the methods of natural air in-bin drying and storage. The method is considered to be more economical, labour saving, and an effective countermeasure to grain loss. To examine the possibility of farm use of the grain bin and to analyze the related factors concerned with in-bin grain drying and storage, ambient air conditions (especially the change of air temperature and relative humidity) and grain quality during drying and storage periods were investigated. A laboratory model bin was constructed to investigate the effect of different forced air conditions on the drying characteristics of rice. In addition, a grain bin with 2.2m diameter and 1.8m height, considered to be the optimum size for the average Korean farm, was constructed and tested to examine the drying and storing characteristics of rice. The weather data analyzed in this study was the nine-year (from 1964 to 1972) record of air temperature and relative humidity in the Suweon area, and the thirty-year (from 1931 to 1960) record of pentad normal relative humidity and air temperature in the Seoul area. From the results of the weather data analyses, the adequate air delivery hours (which was arbitrary defined as the condition to give less than 75% relative humidity) to dry the rice during October were about nine hours (from approximately 10 A.M. to 7 P.M, ) a day, in which the average air temperature was about 15.9$^{\circ}C$ and average relative humidity was 66%. The occurence of days having three hours of such conditions was 1, 2, and 1-day within the 1st, 2nd add last 10-day periods for the month of October, respectively. Therefore, it may be considered that the weather condition in October was satisfactory for the forced natural air drying. The results of the laboratory model bin test were analyzed to obtain the drying curve and drying rate for different drying stages and grain layers in the bin corresponding to various conditions of forced natural air. A drying experiment with a prototype grain bin showed that an approximate 5 percent grain moisture gradient through a 1.6 meter grain deposit was observed after 80 hours of intermittent drying, giving an over dried zone in the lower grain layers and an extremely high grain moisture zone in the upper layers. This indicates that an effective measure should be taken to reduce this high moisture gradient. In order to investigate the drying characteristics of bulk grain in a layerturning operation a grain bin test was performed. This showed a significant improvement of uniform drying. In this test, approximate 107 hours were required to dry a depth of 1.6 meter of grain from an initial moisture content of 22.2 percent to a moisture content of 16.7 percent using an air delivery rate of 2.8 cubic meter per a minute per every cubic meter of grain. This resulted in a 2 percent moisture gradient from the top to the bottom of the bin. During storage period, till the end of June the average temperature of grain was 2~3$^{\circ}C$ higher than ambient air temperature. But during July when the grain moisture content went up slightly (less than 1 percent), the average temperature of the grain also increased to 3~5$^{\circ}C$ higher than ambient air temperature. It is therefore recommended that for safe grain storage, grain should not be stored in sheet metal bins after mid May. From the above results, in-bin rice drying and storage can be used effectively on Korean farms. It is strongly recommended that the use of grain-bin system should be implemented for farm use to improve farm drying and storage of rice.

  • PDF

AA-GWR Water Retention Meter를 이용한 부동화 농도 측정법

  • 최창학
    • 한국펄프종이공학회:학술대회논문집
    • /
    • 한국펄프종이공학회 2003년도 춘계학술발표논문집
    • /
    • pp.80-92
    • /
    • 2003
  • The water retention of coating colors can be accurately measured by devices such as an AA-GWR water retention meter whose principle of measurement is based on pressure filtration of coatings under an externally applied air pressure over a certain period of time. It was hypothesized that such devices could be also used to determine the immobilization solids(IMS) of coating colors by determining a sudden drop in the rate of dewatering, that is, a sudden change in the drainage curves. To test this hypothesis, the immobilization solids of coating colors containing various thickeners and water retention additives at different levels were first accurately measured by a modified immobilization tester based on the well-known gloss drop method, and then their values were compared with those obtained by an AA-GWR water retention tester. They agreed very well and showed that the mean of the solids differences is 0.36% in the IMS points between both methods. This good agreement was not surprising because both test methods are based on the same end-point, that is, the immobilization solids point at which menisci begin to form at the coating surface. Theoretical considerations supporting this new method for measuring the immobilization solids of coating colors are presented and some recommendations for the test method are discussed. Also, the effect of various thickeners and water retention additives on the properties and printability of coated papers is discussed.

  • PDF

제주지역 지하공기를 이용한 농업시설용 히트펌프시스템의 난방 성능 분석 - 제주지역을 중심으로 - (The Analysis of heating performance of heat pump system for agricultural facility using underground air in Jeju area - Focused on the Jeju Area -)

  • 강연구;임태섭
    • KIEAE Journal
    • /
    • 제16권6호
    • /
    • pp.109-114
    • /
    • 2016
  • Purpose: The underground air is the warm air discharged from the porous volcano bedrock 30-50m underground in Jeju, including excessive humidity. The temperature of the underground air is $15-20^{\circ}C$ throughout the year. In Jeju, the underground air was used for heating greenhouses by supplying into greenhouses directly. This heating method by supplying the underground air into greenhouses directly had several problems. The study was conducted to develop the heat pump system using underground air as heat source for resolving excessive humidity problem of the underground air, adopting the underground air as a farm supporting project by Ministry of Agriculture, Food and Rural Affairs(MAFRA) and saving heating cost for agricultural facilities. Method: 35kW scale(10 RT) heat pump system using underground air installed in a greenhouse of area $330m^2$ in Jeju-Special Self-Governing Province Agricultural Research & Extension Services, Seogwipo-si, Jeju. The inlet and outlet water temperature of the condenser, the evaporator and the thermal storage tank and the underground air temperature and the air temperature in the greenhouse were measured by T type thermocouples. The data were collected and saved in a data logger(MV200, Yokogawa, Japan). Flow rates of water flowing in the condenser, the evaporator and the thermal storage tank were measured by an ultrasonic flow meter(PT868, Panametrics, Norway). The total electric power that consumed by the system was measured by a wattmeter(CW240, Yokogawa, Japan). Heating COP, rejection heat of condenser, extraction heat of evaporator and heating cost were analyzed. Result: The underground air in Jeju was adopted as a farm supporting project by Ministry of Agriculture, Food and Rural Affairs(MAFRA) in 2010. From 2011, the heat pump systems using underground air as a heat source were installed in 12 farms(16.3ha) in Jeju.

공기압 구동장치의 에너지효율 평가 (Evaluation of Energy Transfer Efficiency of Pneumatic Driving Apparatus)

  • 장지성;지상원
    • 동력기계공학회지
    • /
    • 제15권6호
    • /
    • pp.95-100
    • /
    • 2011
  • In this study, an evaluation equation of energy efficiency of pneumatic driving apparatus is proposed. The evaluation equation is derived from state equation and energy equation of air in a control volume, and, the equation of motion of a moving part of a pneumatic cylinder. As a result, distribution of consumption energy and energy efficiency of pneumatic driving apparatus can be analyzed quantitatively. The effectiveness of the proposed method is proved by a pneumatic cylinder driving apparatus using a meter-out driving method.

지중 열교환기 보어홀 그라우팅 재료의 열전도도 측정 (Thermal Conductivity Measurement of Grouting Materials for Ground Heat Exchanger Borehole)

  • 손병후;신현준
    • 설비공학논문집
    • /
    • 제18권6호
    • /
    • pp.493-500
    • /
    • 2006
  • This paper concerns the measurement of thermal conductivity of grouting materials for ground loop heat exchanger. A thermal conductivity meter, QTM-500 based on modified transient hot wire method was used to measure the thermal conductivity of neat bentonite and mixtures of bentonite and various additives. Relative to the total mixture mass, as the percent additive was increased the mixture thermal conductivity increased. For the bentonite-silica sand mixtures, the higher density of the sand particles resulted in much higher mixture thermal conductivity. The quartzite and silica sands produced the largest increases in mixture thermal conductivity, while common masonry and limestone sands produced lower thermal conductivity increases.

Survey evaluation of thermal boundary condition in the inside and outside of double skin facade

  • Shin, Hyun-Cheol;Jang, Gun-Eik
    • KIEAE Journal
    • /
    • 제15권4호
    • /
    • pp.29-35
    • /
    • 2015
  • Purpose: Double skin facade is a representative advantageous passive technology of building skin in the aspect of energy saving and environment improvement, reduces heat loss with buffer space in winter season and enhances indoor air and comfort of residents by activating natural ventilation in mid-season. However, in summer season, temperature increase in the intermediate space due to solar energy from exterior transparent skin could be a potential problem; also, relatively weak buoyancy of air caused by low density difference between double-skin facade could increase cooling load as air of intermediate space in high temperature hangs. However, proof data is insufficient to objectify such phenomenon. Method: In this study, researchers surveyed air temperature of intermediate space and airflow and diagnosed its cause targeting on applied multistory facade in the building which gives thermal uncomfort to residents. Also, the researchers produced Solar-air heat transfer coefficient meter, measured thermal boundary condition of double-skin facade, and presented the result of measurement as an objectified verification material regarding overheating phenomenon in the intermediate space of double-skin facade in summer season. Result: Inefficient condition was verified that total heat increases and overheating due to insufficient natural ventilation in multistory facade. In addition, logic behind preceding research was objectified and verified regarding high temperature phenomenon in the intermediate space which could increase cooling load in summer season.