• Title/Summary/Keyword: air mass factor

Search Result 205, Processing Time 0.024 seconds

Mass Transfer and Hydraulic Kinematic Character Using Lattices Packings by Countercurrent Flow of Gas-Liquid Phase in Packing Column (격자형 충진물을 이용한 충진탑내 기액상의 역류에 의한 물질전달과 수력학적 동특성)

  • Kim, Jang-Ho;Ha, Sang-An
    • Journal of Ocean Engineering and Technology
    • /
    • v.2 no.2
    • /
    • pp.130-137
    • /
    • 1988
  • This thesis introduced that character of a treatment technique for a mading synthetic resin Hifiow-Ring. The material system of packings make an experiment air$NH_{3}$/air$H_{2}SO_{4}$, $SO_{2}$-air/NaOH, $NH_{3}$-air/$/H_{2}SO_{4}$ under general conditions. Lattices packing compared with conventional packings was proved low pressure loss and high separation efficiency for high loading per trans unit. And an inflow materal tested for absorption and rectification, it made an experiment under a range regular temperature, low energy and small amount of money. That made possible in simple equation, volume material tranfer coefficient$\beta_{L}$ . a by absorption or $\beta_{V}$ .a calculated in all range loading. The peculiarity pressure loss $\Delta\;P/NUT_{ov}$ for Hiflow-ring contributed to a fall cost of energy, a grade number of a vacuum rectification and absorption calculation.

  • PDF

Flexural Vibration of Stiffened Plates in Contact with Water (보강판(補剛板)의 접수진동(接水振動))

  • K.C.,Kim;K.P.,Rhee;H.Y.,Lee
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.17 no.2
    • /
    • pp.11-16
    • /
    • 1980
  • For vibration analysis of stiffened plates the orthotropic plate analogy is commonly accepted. As to stiffened plates in contact with water, however, there is still much uncertainty in estimation of the added mass because of the lack of direct methods. The authors, considering that for added mass of plates there are many reliable data derived theoretically or experimentally available, suggest a method to estimate the added mass of a stiffened plate by combining the mass increase factor, $\beta$, of an equivalent orthotropic plate and the correction factor, $\kappa$, for the effects of stiffeners. The latter is to be derived from systematic experimental investigations. Then, the natural frequency in water, f', can be calculated from that in air, f, by the equation $f'=f/\sqrt{1+\kappa\beta}$. To investigate practical applicability of this method, a systematic experiment was carried out with five uniaxially stiffened plates. Each of them had a plate of same size, $600mm{\times}600mm{\times}3.2mm$, but stiffeners of different size in the web-depth, 41.6mm, 51.2mm or 66.8mm and of different spacing 75mm, 100mm, or 150mm. Natural frequencies were measured under simply supported-edge conditions in both air and water, and corresponding $\kappa$ values derived. In spite of wide variations of web-depth and spcae of stiffeners, the experimental results show that the diversity of $\kappa$ values is not remarkable; mean values of $\kappa$ are 1.31 with standard deviation of 0.025 for the first modes and 1.27 with that 0.077 for the second modes. Hence, the authors concluded that the above $\kappa$ values can be used generally for the cases of uniaxially stiffened plates both sides of which contact with water, and that $\kappa$ values of general use for the cases of cross-stiffened plates may also be obtainable from similar experiments.

  • PDF

Application of chemical Mass Balance Model for the Source Apportionment of Polynuclear Aromatic Hydrocarbons in Urban Atmosphere (도시 대기오염물중 다환방향족 탄화수소의 배출원 규명을 위한 화학물질 수지모델의 적용)

  • 구자공;서영화
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.8 no.4
    • /
    • pp.229-239
    • /
    • 1992
  • A receptor model application was performed by using a chemical mass balance (CMB) model to identify and apportion the specific source of airborne organic pollutants, particularly polynuclear aromatic hydrocarbons (PAHs). Source profiles of PAHs produced from the combustion of fossil fuels for CMB modeling were prepared by measuring them in emission gases. The emission sources which were examineed for the development of PAH source profiles are a coal-fired furnace using Yontan, a bunker-C iol heating boiler, and gasoline-and diesel engine automobiles. The ambient concentrations of PAHs were determined at four sites in Daejon city in 1991 with a seasonal variation. Wintertime air samples contained more extractable organic matter than summertime samples. The results of CMB modeling were various depending on the sampling sites and seasons, but the emission from bunker-C oil heating boliers was the predominant factor to affect local air quality throughout the year.

  • PDF

Experiments on Condensation Heat Transfer Characteristics and Flow Regime Inside Microfin Tubes (마이크로핀관내 유동 양식과 응축 열전달 특성 연구)

  • 한동혁;이규정
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.7
    • /
    • pp.602-611
    • /
    • 2001
  • Experiments on the condensation heat transfer characteristics inside a smooth and a microfin tube with R410A/R22 are performed in this study. The test tubes 7/9.52 mm in outside diameters and 3m in length are used. Varying the mass flux of the refrigerant and the condensation temperatures, the average heat transfer coefficients and pressure drop are investigated. Most flows in this study are in the annular and/or wavy flow regime. It is shown that the heat transfer is enhanced and the pressure drops are larger in the microfin tube than the smooth tube. From the heat transfer enhancement coefficients and the pressure drops, it is found that the high heat transfer enhancement factors are obtained in the range of small mass flux while the penalty factors are almost equal. Experiments results show that average heat transfer coefficients of R410A is larger than that of R22 and pressure drop of R410A is less than R22.

  • PDF

Evaluation of Heat Balance for Cooling System of an Armored Installation in Small Space (좁은 공간 내의 밀폐형 장치 냉각시스템에 대한 열평형 평가)

  • Kim, Sung-Kwang;Ahn, Seok-Hwan;Nam, Ki-Woo
    • Journal of Ocean Engineering and Technology
    • /
    • v.21 no.3 s.76
    • /
    • pp.1-7
    • /
    • 2007
  • In this study, the heat balance test of an engine was conducted, and the heat released to coolant is measured and corrected using a power adjustment factor for high fuel temperature to simulate heat rejection of the engine. An engine-converter matching simulation program which can compute the engine speed, transmission output speed, transmission input and output power is developed from the vehicle, transmission and engine performance curve. With this information and the engine heat rejection characteristics, the engine and transmission heat rejection rates can be determined at given condition. In analyzing the air mass flow, a sub program computing the air mass flow rate from the equation of the pressure balance between cooling fan static pressure rise and pressure losses of cooling components is developed.

Evaluation of Air-side Friction Characteristics on Design Conditions of Slit Fin and Tube Heat Exchanger (슬릿휜-관 열교환기의 설계조건에서 공기측 압력강하 산출)

  • Cho, Sung-Chul;Kim, Chang-Duk;Kim, Chang-Eob;Kwon, Jeong-Tae;Lim, Hyo-Jae
    • Journal of Energy Engineering
    • /
    • v.16 no.3
    • /
    • pp.149-154
    • /
    • 2007
  • An experimental study on the air-side pressure drop of slit fin-tube heat exchanger has been carried out. The data reduction methodology for air-side pressure drop in the literature is not based on a consistent approach. This paper focuses on method of data reduction to obtain the air-side performance of fin-tube heat exchanger using R22 and recommends standard procedures for dry and wet surface pressure drop estimation in fin-tube heat exchanger. A comparison was made between the predictions of previously proposed empirical correlations and experimental data for the air-side pressure drop on design conditions of condenser and evaporator. Results are pre-sented as plots of friction f-factor against Reynolds number based on the fin collar outside diameter and compared with previous studies. The data covers a range of refrigerant mass fluxes of $150{\sim}250\;kg/m^2s$ with air flows at velocity ranges from 0.38 m/s to 1.6 m/s.

Development of the Dynamic Simulation Program for the Multi-Inverter Heat Pump Air-Conditioner (멀티 인버터 히트펌프의 동특성 해석 프로그램의 개발)

  • ;;小山繁
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.11
    • /
    • pp.1079-1088
    • /
    • 2001
  • A dynamic simulation model was developed to analyse the transient characteristics of a multi-inverter heat pump. The programs included a basic air conditioning system such as a evaporator, condenser, compressor, linear electronic expansion valve (LEV) and by-pass circuit. The theoretical model was derived from mass conservation and energy conservation equations to predict the performance of the multi-inverter heat pump at various operating conditions. Calculated results were compared with the values obtained from the experiments at different operation frequencies of compressor, area of the LEV and configuration of indoor units operation. The results of the simulation model showed a good agreement with the experimental ones, so that the model could be used as an efficient tool for thermodynamic design and control factor design of air-conditioners.

  • PDF

Cultural Characteristics and Scale-up for Submerged Cultivation of Hericium erinaceum Through Air-lift and Jar Fermenter System (Air-lift 및 Jar Fermenter에 의한 Hericium erinaceum 심부배양의 배양특성 및 Scale-up)

  • Jung, Jae-Hyun;Lee, Keun-Eok;Lee, Shin-Young
    • KSBB Journal
    • /
    • v.21 no.2
    • /
    • pp.103-109
    • /
    • 2006
  • For the study of Hericium erinaceum as a useful functional foods and materials, liquid cultivation under two different bioreactors(air-lift fermenter and jar fermenter) which was not studied systematically until now, was conducted as a method of mass cultivation for H. erinaceum. A batch cultivation in an air-lift fermenter and a jar fermenter was examined for enhancing the productivity because of small amounts of mycelial weight and slow growth in case of a liquid culture for H. erinaceum. We found that air lift fermenter system was more effective than jar fermenter for mycelial production of H. erinaceum, and mycelial morphology was a critical factor of the growth. By scale-up and cultivation based on morphological analysis, the conditions for mass production with 30 L and 500 L jar fermenter was 200 and 150 rpm of agitation speed at 1 vvm of aeration rate, respectively, and mycelial dry weight under these conditions was enhanced to about $13{\sim}14g/L$.

Estimation of Source Strength and Deposition Constant of Nitrogen Dioxide Using Compartment Model (구획모델을 이용한 주택에서 이산화질소의 발생강도 및 감소상수 동시 추정)

  • Yang Won-Ho;Son Bu-Soon;Sohn Jong-Ryeul
    • Journal of Environmental Health Sciences
    • /
    • v.31 no.4 s.85
    • /
    • pp.260-265
    • /
    • 2005
  • Indoor air quality might be affected by source strength of indoor pollutants, ventilation rate, decay rate, outdoor level, and so on. Although technologies measuring these factors exist directly, direct measurements of all factors are not always practical in most field studies. The purpose of this study was to develop an alternative method to estimate the source strength and deposition constant by application of multiple measurements. For the total duration of 60 days, indoor and outdoor $NO_2$ concentrations every 3 days were measured in 30 houses in Seoul, Asan and Daegu. Using a compartment model by mass balance and linear regression analysis, penetration factor (ventilation divided by sum of air exchange rate and deposition constant) and source strength factor (emission rate divided by sum of air exchange rate and deposition constant) were calculated. Subsequently, the source strength and deposition constant were estimated. Natural ventilation was $1.80{\pm}0.42\;ACH,\;1.11{\pm}0.50\;ACH,\;0.92{\pm}0.26\;ACH$ in Seoul, Asan and Daegu, respectively. Calculated deposition constant(K) and source strength of $NO_2,$ in this study were $0.98{\pm}0.28\;hr^{1}\;and\;16.28{\pm}7.47\;ppb/h,$ respectively.

An Assessment of Friction Factor and Viscosity Models for Predicting the Refrigerant Characteristics in Adiabatic Capillary Tubes (마찰 계수와 점성 계수 모델이 단열 모세관 유동에 미치는 영향 평가)

  • Son, Ki-Dong;Park, Sang-Goo;Jeong, Ji-Hwan;Lee, Sung-Hong;Kim, Lyun-Su
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.3
    • /
    • pp.140-148
    • /
    • 2009
  • Capillary tubes are widely used as expansion device in small refrigeration systems. The refrigerant flowing in the capillary tube experiences frictional and accelerational head losses and flashing simultaneously. In this paper flow characteristics of adiabatic capillary tubes were simulated with various friction factor models, two-phase viscosity models, and two-phase frictional multiplier models. The predicted pressure distribution and mass flow rate are compared with experimental data reported in literature. It is confirmed that the predicting accuracy with homogeneous model can be improved by employing suitable correlations of friction factor, two-phase viscosity and two-phase frictional multiplier.