• Title/Summary/Keyword: air humidity

Search Result 1,847, Processing Time 0.036 seconds

Studies on the Prevention of Excessive Drying Leaves during Burley Tobacco Curing I. Effect of Temperature and Relative Humidity on the Production of Excessive Drying Leaves (버어리종 담배건조시 급건엽 발생방지에 관한 연구 I. 온습도의 영향)

  • 배성국;임해건;추홍구
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.31 no.4
    • /
    • pp.420-425
    • /
    • 1986
  • This study was conducted to investigate the influence of air temperature and relative humidity on excessive drying rate of burley tobacco. In experiment I, 4 temperatures and I humidity by day and air curing by night were treated from initial curing stage. In experiment II, 15 combinations of 3 temperatures and 5 humidities were applied from the yellow stage of cure. Yellowish cured leaves resulted from overdrying at high temperature and especially, at low humidity. How- ever, these were not produced at 75-80% RH and under 35$^{\circ}C$ by day with air curing b y night. The proper range of temperature and humidity for desirable color of cured leaf were the combinations of 30$^{\circ}C$, 75-80% RH or 35$^{\circ}C$, 80-85% RH. As excessive drying leaves increased, physical properties of cured leaves were poorer and chemical contents were less decomposed.

  • PDF

Drying Characteristics and Drying Model of Red Pepper (고추의 건조특성(乾燥特性)과 건조모델에 관(關)한 연구(硏究))

  • Cho, Y.J.;Koh, H.K.
    • Journal of Biosystems Engineering
    • /
    • v.11 no.1
    • /
    • pp.52-63
    • /
    • 1986
  • This study was performed to find out drying characteristics and develop drying model for the design of an efficient dryer or drying system of red peper. The basic model which describes drying phenomenon of red pepper was firstly established, and drying tests were conducted at 14-different drying conditions. In this test, the effects of drying air temperature and relative humidity on the rate of drying were undertaken. Finally, a new drying model based on these experimental results was developed to describe the drying characteristics of red pepper. The results from this study may be summarized as follows. 1. Drying constant of the basic model established from Lewis' experimental model and diffusion equation was theoretically deduced as a function of moisture content and inner-temperature of red pepper. 2. From the results of drying tests, drying air temperature was found to have the greatest effect on the rate of drying. However, the effect of temperature was small for the condition of high relative humidity, and for low temperature, the effect of relative humidity was found to be large even though the range of relative humidity was low. 3. Modified Henderson equation was found to be better than Chung equation as the EMC model for the estimation of the equilibrium moisture content of red Pepper. 4. Constant-rate drying period did not exist in the red pepper drying test. And falling-rate drying period was divided into three distinct phases. Drying rate was dependent on the moisture content, the inner-temperature of red pepper and the change of physical property due to drying. 5. Drying constant increased with decrease of free moisture content, but it decreased at the end of the drying period. Also, drying constant was dependent on the drying air temperature and relative humidity. 6. The new drying model developed in this study was found to be most suitable in describing the drying characteristics of red pepper. Therefore, it may be concluded that drying time could be accurately estimated by the new drying model.

  • PDF

On-Site Measurement of the Inlet Air Evaporative Cooling Performance for a Centrifugal Turbo Compressor (CDA 인입공기 증발냉각을 통한 압축기 성능 개선장치 개발 연구)

  • Kim, Gyu Wan;Park, Jin Ouk;Kim, Heuy Dong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.11
    • /
    • pp.873-879
    • /
    • 2014
  • In the present study, water vapor is injected at various positions in a Clean Dry Air (CDA) system such as a system inlet duct, compressor inlet, and compressor outlet by humidified air turbines. The application of evaporative cooling reduces the compression work and enhances the Energy Consumption Index (ECI) per unit volume. The main purpose of this study is to investigate the compressor power performance with different inlet air temperatures and humidity conditions. It is found that the actual power consumption and discharge flow are significantly influenced by the inlet air temperature as well as relative humidity. The results obtained during this study are compared both numerically and experimentally and are found to be in very good agreement.

Research on Durability Assessment of Asbestos Stabilizer for Asbestos-containing Ceiling Materials (석면 함유 천장재에 대한 석면 안정화제 내구성 평가 연구)

  • Ha, Joo-Yeon;Shin, Hyun-Gyoo
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.30 no.1
    • /
    • pp.18-27
    • /
    • 2020
  • Objectives: For testing asbestos stabilizer products which are used for the maintenance and management of asbestos-containing materials, durability assessment should accompany the evaluation of basic properties and performance. Therefore, in this study we designed a testing method and constructed a database of durability performance, thereby providing basic data for reliability studies of asbestos stabilizer. Methods: Since the ceiling materials targeted in this study are interior materials, test conditions of 95% relative humidity and 60℃ temperature were designed in consideration of the effect of high relative humidity in summer and seasonal indoor temperatures. Plate-shaped specimens treated with asbestos stabilizers were maintained in a thermo-hygrostat for 5, 10, and 20 days, and then the asbestos scattering prevention rate was measured by air erosion testing. Results: The scattering concentration tended to increase with time under the single humidity condition, and exceeded the indoor air quality standard of 0.01 f/cc, during the 20 days of maintenance. On the other hand, there was little change according to the temperature condition. In the case of a complex condition with temperature and humidity, the results were similar to the humidity test, but the scattering concentration increased more sharply at 20 days. Conclusions: The main deterioration factor that affects the durability of asbestos stabilizer is humidity, and the deterioration is caused by a mechanism in which the stabilizer coated on the surface is re-dissolved by moisture and evaporates or the coating layer is peeled off, which is accelerated by high temperatures.

Analysis of the Effect of Particle Size and Humidity on Reaction Characteristics of $CaCO_3$ Sorbent Particle under Air and $O_2/CO_2$ Atmospheric Conditions (공기연소 분위기와 순산소 연소 분위기에서 입자 크기와 습도가 $CaCO_3$ 흡착제 입자의 반응특성에 미치는 영향 분석)

  • Jeong, Seongha;Lee, Kang Soo;Keel, Sangin;Yun, Jin Han;Kim, Sang Soo
    • Particle and aerosol research
    • /
    • v.10 no.2
    • /
    • pp.75-82
    • /
    • 2014
  • It is necessary to find out the reaction characteristics of $CaCO_3$ sorbent particles in air and $O_2/CO_2$ atmospheric conditions in order that an in-furnace desulfurization technique can be applied to oxy-fuel combustion system. In this study, rate of change of GMD(geometric mean diameter) and specific surface area of $CaCO_3$ sorbent particles reacted in DTF(drop tube furnace) experimental setup were analyzed to investigate the effect of particle size and humidity on the reaction characteristics of them. In air atmospheric condition, calcination process occurs actively within shorter residence times as the particle size increases. On the contrary, in $O_2/CO_2$ atmospheric condition, a calcination process is delayed as particle size increases. The increment of humidity accelerates calcination process in an air atmospheric condition and increase rate of calcination in an $O_2/CO_2$ atmospheric condition.

A Study on the Sanitary Condition of Kitchens in Food Court/Cafeterias - An Observation on Seasonal Variations (휴게음식점 주방의 환경위생상태에 관한 조사연구 - 계절별 변화를 중심으로 -)

  • Kim, Jong-Gyu;Park, Jeong-Yeong;Kim, Joong-Soon
    • Journal of Environmental Health Sciences
    • /
    • v.38 no.2
    • /
    • pp.118-127
    • /
    • 2012
  • Objectives: This study was undertaken to assess the sanitary conditions in the kitchens of food court/cafeterias and determine seasonal variations. Methods: We measured environmental factors (air temperature, relative humidity, illumination intensity, noise level), and dropping airborne microbes (bacteria and fungi) in the kitchens of eight food court/cafeterias in four seasons (January, April, July, and October). Air temperature and relative humidity were measured with in/out thermo-hygrometers at 1.2-1.5 m above floor level. Illuminance measurement was performed through the multiple point method of Korean Standards (KS). Noise level was measured by the standard methods for the examination of environmental pollution (noise and vibration) of Korea. The estimation of dropping airborne bacteria and fungi was performed through use of Koch's method. Results: The highest kitchen air temperature was in July, and the lowest in January. The average temperature surpassed $21^{\circ}C$ throughout the seasons, suggesting a higher temperature than required for the safe handling of food. Humidity in all the kitchens was measured in the range of 50-60%. Half of the kitchens showed illumination intensities below 300 Lux in April. It was found that the sound pressure level of noise in almost all of the kitchens was higher than 85 dB (A). The highest levels of dropping airborne bacteria and fungi were noted in July. The numbers of airborne bacteria were higher than those of fungi. The levels of dropping airborne bacteria and fungi were affected by air temperature, relative humidity, season, and place. Conclusions: This study indicates that the kitchen environments were unqualified to supply safe food. The hygiene level of the kitchens should be improved.

A Measurement and Evaluation of the Indoor Thermal Conditions in Summer of a Newly-Launched 8,500GT Chemical Carrier (신조 8,500GT 화학물 운반선의 여름철 선실 내 온열환경 실측평가)

  • Hwang, Kwang-Il;Doe, Geun-Young;Cho, Hyo-Jae;Woo, Sang-Woo;Shin, Dong-Keol;Lim, Seong-Taek
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.5
    • /
    • pp.717-723
    • /
    • 2008
  • The purpose of this study is to measure and analyze the indoor thermal conditions of a 8,500GT class chemical carrier which was launched on July 2007. The measurement was operated from 4th June to 4th June 2007, just before handing over to Owner. Followings are the results of this study. (1)The temperature variations of supply air were related to the outdoor temperature variations, but the humidity was stable at $65{\sim}80%$. (2)The temperature variations at the representative position of bridge, restaurant, crew's cabin showed gentle slopes. but that of conference room was very steepy. The humidities of bridge and restaurant were unstable because of outdoor-contact and cooking, respectively. (4)The temperature and humidity of ECR(Engine Control Room) which was designed to supply heating and cooling by PAC(Package Air Conditioner) were directly affected by the operating conditions of PAC. (5)The measured supply air volume from dampers of bridge, crew's cabin and conference room were satisfied with the design supply air volume. (5)For the improvement of the indoor thermal conditions, the temperature of crew's cabin and restaurant and the humidity of conference room, and the temperature and humidity of bridge should be controlled, respectively.

A Study on the Indoor Environment of school classrooms in Seoul area (서울지역 학교 교실의 실내환경 조사연구)

  • 최한영
    • Journal of environmental and Sanitary engineering
    • /
    • v.18 no.2
    • /
    • pp.67-74
    • /
    • 2003
  • In 15 schools where were chosen each location (East, West, South, North, Central) of Seoul area, 9 items were measured such as thermo circumstance(temperature, relative humidity, air current, intensity of illumination) particulate matter, carbon monoxide, sulfur dioxide, and nitrogen dioxide being based on the school indoor environment standard. It was showed that indoor temperature, relative humidity and air movement were suitable in comparison with school indoor environment standard. Intensity of illumination was suitable in comparison with all schools, only exception 2 schools. In all investigated schools were adequate for carbon monoxide, sulfur dioxide and nitrogen dioxide, in which each indoor environment standard (10ppw, 0.25ppm/hr, 0.15ppm/hr), but in 5 schools the carbon dioxide were exceeded for standard limit 1,000ppm of Korea. Indoor concentration of dust(PM-10) induced from respiration dust the standard of Korea ($150{\mu}g/m^3$) at all schools.

Hydrogen Peroxide Concentrations in Air in Seoul (서울시 대기 중 $H_2O_2$의 농도)

  • 강충민;김희강
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.1
    • /
    • pp.61-68
    • /
    • 2000
  • Gas-phase hydrogen peroxide(H2O2) concentrations were measured to investigate it's distribution in the ambient air in downtown Seoul(Kwanghwamum and Mullae-dong). These measurements were made during four season, from April 30, 1998 to January 29, 1999, using Cold Trap and HPLC. Measurements were also made of other photochemical oxidants and trace gases(O3, NO2, CO and SO2) and meteorological parameters(relative humidity, temperature, solar radiation and wind speed). The mean of all observations was 0.10 ppbv and the range measured was below the level of detection(>0.01 ppbv) to 0.47ppbv. The higher seasonal mean concentrations showed during the summer(0.21 ppbv) and concentrations of H2O2 showed a diurnal variation with maximum concentrations in the afternoon(12:30∼14:00). The results from the corrrelation analysis showed that the concentration of gaseous H2O2 is strongly dependent on the other air pollutants(NO2, CO and O3) and meteorological parameters(relative humidity, temperature and solar radiation.)

  • PDF

Performance Characteristics on Environment Change of A/C applied Fin-tube and PF Heat Exchangers (환경변화에 따른 핀-관, PF 열교환기 적용 공조기 성능 특성 실험 연구)

  • Park, K.M.;Um, U.S.;Kwon, Y.C.;Lee, S.J.
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1267-1271
    • /
    • 2009
  • In the present study, performance characteristics on environment change of A/C applied fin-tube and PF heat exchangers were experimentally investigated. Capacity and COP changing an outlet air velocity, an indoor/outdoor temperature and a relative humidity were obtained. Air-enthalpy calorimeter was used. As the air velocity, indoor temperature and relative humidity increase, capacity and COP increase. PF A/C has smaller refrigerant weight than the fin-tube A/C. The performance of PF-2 A/C with the squarer fin was more excellent than that of PF-1 A/C with the triangler fin.

  • PDF