• Title/Summary/Keyword: air hoist

Search Result 7, Processing Time 0.024 seconds

Weightless Control of Air Hoist using Compressed Air (압축공기를 이용한 에어호이스트의 무중력화 제어)

  • 이강호;배상일;홍대선;정원지
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.144-144
    • /
    • 2000
  • Air balance hoists are widely used in handling of heavy materials in industry. Currently used air balance hoists adopt manual switches for vertical motion, thus the operator has a difficulty in operating of the switches and handling of material simultaneously. To overcome this difficulty, this study develops a weightless air-balance-hoist system using compressed air. This system memorizes the weight of material in terms of pneumatic pressure with a pneumatic circuit. Such memory of the material weight is used for achieving weightless handling of materials. Through a series of experiments, handling forces and the response of the system for various material weights are analyzed. The results show that the developed system can be used for weightless handling o( heavy materials.

  • PDF

Power Control of a Hoist System Using Supercapacitor (수퍼캐패시터를 이용한 권상부하 시스템의 전력 제어)

  • Kim, Sang-Min;Yoo, Hyun-Jae;Sul, Seung-Ki
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.11
    • /
    • pp.561-568
    • /
    • 2005
  • This paper proposes a method that distributes the load power and stores the regenerated energy for a hoist-load system using the supercapacitor, an energy storage device. The crane, which is a representative hoist-load system, operates in two modes. The first is the hoist-up mode in which the load container is lifted up: the maximum power is required at the end of acceleration. The second is the hoist-down mode in which the load container is lifted down; the regenerated energy is wasted by the resistor In this paper, the supercapacitor stores the regenerated energy in the hoist-down operation and supplies the peak power demand in the hoist-up operation. The same structure as the commercially available three-phase inverter is proposed as a bidirectional do-dc converter to charge and discharge the supercapacitor. A power control algorithm is proposed to optimize the load sharing between the generator and the supercapacitor. Using the proposed method, it is effected that the generator size can be cut down to one third of the original one; it leads to the reduction of the fuel consumption, noise and air pollution. Simulation and experimental results verify the effectiveness of the Proposed method.

Branch-and-Bound Based Heuristic Scheduling for the Single-Hoist and Multiple-Products Production System (단일 호이스트 생산시스템에서 다양한 주문을 처리하기 위한 분지한계 기반의 휴리스틱 일정계획)

  • Lee, Jungkoo;Kim, Jeongbae;Koh, Shiegheun
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.42 no.3
    • /
    • pp.173-181
    • /
    • 2016
  • This paper deals with the single-hoist and multiple-products scheduling problem. Although a mixed integer linear programming model for the problem was developed earlier, a branch-and-bound based heuristic algorithm is proposed in this paper to solve the big-size problems in real situation. The algorithm is capable of handling problems incorporating different product types, jobs in the process, and tank capacities. Using a small example problem the procedure of the heuristic algorithm is explained. To assess the performance of the heuristic we generate a bigger example problem and compare the results of the algorithm proposed in this paper with the optimal solutions derived from the mathematical model of earlier research. The comparison shows that the heuristic has very good performance and the computation time is sufficiently short to use the algorithm in real situation.

Development of Pneumatic Control System with Anti-leakage (누기 보상기능을 보유한 공압제어장치의 개발)

  • 엄태진;김태형;정원지
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.725-728
    • /
    • 2000
  • Air hoist system has been using in the industry. In gradually, the system of function was developing, but system was not enough compensation for leakage. In this paper, developed the anti-leakage system with stability and convenience of operate.

  • PDF

A Study n the Simulation-based Design Approach for Pneumatic Control System with Anti-leakage (시뮬레이션을 기초로한 누기보상 공압제어밸브시스템의 Design Approach에 관한 연구)

  • 김태형;정원지;최은재
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.488-491
    • /
    • 1997
  • In this paper, a ncw control 'ialvc which can misc air-iraksge pneumatically and compensate pressure drop for an alrho~ st system uas proposed A new control valve called "Pneuniatic C70ntro1 Valve (PCV)" functions as a control valve to compcns;ltc prcssure in thc casc of air-leakage. by using the pure pneummatic control ofpilot pressure. Based on the sirnulation of the proposed PCY, thc experimental system was fabricaied su as to illustrate the efficient pcrformance of the proposed PCV with anti-leakage. Such good perfo~manccs of PCV in the air-hoist system are shown by the simulation. In addition, the simulation bascd design approach presented in this paper can be applied to any hydraulic or pneumatic-hydraulic system.

  • PDF

The Optimized Design of a NPC Three-Level Inverter Forced-Air Cooling System Based on Dynamic Power-loss Calculations of the Maximum Power-Loss Range

  • Xu, Shi-Zhou;He, Feng-You
    • Journal of Power Electronics
    • /
    • v.16 no.4
    • /
    • pp.1598-1611
    • /
    • 2016
  • In some special occasions with strict size requirements, such as mine hoists, improving the design accuracy of the forced-air cooling systems of NPC three-level inverters is a key technology for improving the power density and decreasing the volume. First, a fast power-loss calculation method was brought. Its calculation principle introduced in detail, and the computation formulas were deduced. Secondly, the average and dynamic power losses of a 1MW mine hoist acting as the research target were analyzed, and a forced-air cooling system model based on a series of theoretical analyses was designed with the average power loss as a heat source. The simulation analyses proves the accuracy and effectiveness of this cooling system during the unit lifting period. Finally, according to an analysis of the periodic working condition, the maximum power-loss range of a NPC three-level inverter under multi cycle operation was obtained and its dynamic power loss was taken into the optimized cooling system model as a heat source to solve the power device damage caused by instantaneous heat accumulation. The effectiveness and feasibility of the optimization design based on the dynamic power loss calculation of the maximum power-loss range was proved by simulation and experimental results.

Analysis of queuing mine-cars affecting shaft station radon concentrations in Quzhou uranium mine, eastern China

  • Hong, Changshou;Zhao, Guoyan;Li, Xiangyang
    • Nuclear Engineering and Technology
    • /
    • v.50 no.3
    • /
    • pp.453-461
    • /
    • 2018
  • Shaft stations of underground uranium mines in China are not only utilized as waiting space for loaded mine-cars queuing to be hoisted but also as the principal channel for fresh air taken to working places. Therefore, assessment of how mine-car queuing processes affect shaft station radon concentration was carried out. Queuing network of mine-cars has been analyzed in an underground uranium mine, located in Quzhou, Zhejiang province of Eastern China. On the basis of mathematical analysis of the queue network, a MATLAB-based quasi-random number generating program utilizing Monte-Carlo methods was worked out. Extensive simulations were then implemented via MATALB operating on a DELL PC. Thereafter, theoretical calculations and field measurements of shaft station radon concentrations for several working conditions were performed. The queuing performance measures of interest, like average queuing length and waiting time, were found to be significantly affected by the utilization rate (positively correlated). However, even with respect to the "worst case", the shaft station radon concentration was always lower than $200Bq/m^3$. The model predictions were compared with the measuring results, and a satisfactory agreement was noted. Under current working conditions, queuing-induced variations of shaft station radon concentration of the study mine are not remarkable.