• 제목/요약/키워드: air heater

검색결과 485건 처리시간 0.026초

내부 압력변화에 대한 사용후핵연료 분말화장치 가열로의 열 응력 해석 (Thermal Stress Analysis of Spent Fuel Vol-oxidizer Furnace on the Internal Pressure)

  • 김영환;정재후;홍동희;박병석;이종광;윤지섭
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.136-140
    • /
    • 2006
  • We are developing a vol-oxidizer which transforms the spent $UO_2$ pellets into the $U_3O_8$ power through oxidizing process. The vol-oxidizer consists of furnace, filter, heater and valve etc. When the filter is blocked by the powder, the internal pressure of the furnace is increased owing to the air flow restriction. Then, the furnace vessel is swelled and deformed by it. In this paper, we proposed a procedure of the thermal analysis for furnace vessel design of spent fuel vol-oxidizer. In this work, we determined the thickness of the furnace through analyzing the internal pressure and the thermal stress of the furnace with respect to various pressure and temperature. To analyze the thermal stress, we used ANSYS 8.0 for constructing a FEM model of the furnace, and then analyzed it based on the ASME code. We also surveyed the material property and yield stress of SUS304 with various temperature. Analysis results are compared with the yield stress of the material. We manufactured the furnace and conduct the verification experiments.

  • PDF

하수처리수 이용 열원시스템의 경제성 평가 (Economic Evaluation on Energy System Using Treated Sewage Water)

  • 이철구
    • 한국지열·수열에너지학회논문집
    • /
    • 제13권3호
    • /
    • pp.16-22
    • /
    • 2017
  • It has become important for unutilized energy to be used for air conditioning of building. Economic evaluation on energy system by using treated sewage water as heat source, which is one of unutilized energy, was performed. The floor area of the subject building and the distance between heat source equipment and sewage treatment plant was assumed $30,000m^2$ and 200m. Absorption chiller-heater system was used for comparing to the energy efficient system, and payback period method was applied to carry out economic evaluation. Although the operating cost of this system is reduced compared to general heat source system, the ratio is not meaningful compared to the initial investment cost increase, and payback period was calculated to be about 36.1 years. However, when calculated based on the 2014 rate of electricity and city gas, it will be greatly reduced to 3.1 years. International commodity prices are constantly changing, and therefore national policy on the spread of unutilized energy should be maintained.

헬리컬 흡수기의 열ㆍ물질전달 특성에 관한 실험적 연구 (An Experimental Study on Beat and Mass Transfer Characteristics of Helical Absorber)

  • 권오경;윤재호;윤정인
    • 대한기계학회논문집B
    • /
    • 제28권1호
    • /
    • pp.81-88
    • /
    • 2004
  • In this study, heat and mass transfer characteristics of five components solution (LiBr+Lil+LiNO$_3$+LiCl+$H_2O$) which could be substituted for commonly used LiBr solution are tested using a helical absorber. The arrangement of helical-typed heat exchangers allows to make the system more compact as compared to conventional one. The effects of experimental parameters, such as the solution flow rate, cooling water, solution temperature, solution concentration and surfactant have been investigated in view of the heat and mass transfer. The results of the experiment of heat and mass transfer performance show that five components solution should have 2% higher concentration fur equal absorption capacity of LiBr solution. But considering that five components solution have higher solubility than LiBr solution about 4% high concentration, five components solution could be applied to a small sized water cooled or air cooled absorption chiller/heater. The increase of heat and mass transfer coefficient by surfactant addition is about 25∼30% and 23∼40% respectively.

물/PG-기반 $Al_2O_3$ 나노유체를 적용한 수냉식 CPU 쿨러의 냉각성능 (Cooling Performance of Liquid CPU Cooler using Water/PG-based $Al_2O_3$ Nanofluids)

  • 박용준;김규한;이승현;장석필
    • 한국분무공학회지
    • /
    • 제19권1호
    • /
    • pp.19-24
    • /
    • 2014
  • In this study, the cooling performance of a liquid CPU cooler using the water/propylene glycol(PG)-based $Al_2O_3$ nanofluids is experimentally investigated. Water/PG-based $Al_2O_3$ nanofluids are manufactured by two-step method with ultrasonic energy for 10 hours. The volume fractions of the nanofluids are 0.25% and 0.35%. Thermal conductivity and viscosity of the nanofluids are measured to theoretically predict the thermal performance of the liquid CPU cooler using performance factor. Performance factor results indicate that the cooling performance of the liquid CPU cooler can be improved using the manufactured nanofluids. To evaluate the cooling performance of the liquid CPU cooler experimentally, temperature differences between ambient air and heater are measured for base fluid and nanofluids respectively. Based on the results, it is shown that performance of the liquid CPU cooler using $Al_2O_3$ nanofluids is improved maximum up to 8.6% at 0.25 Vol.%.

유기 랜킨 사이클을 이용한 선박 주기관 폐열회수 시스템의 적용성과 최적화 (Feasibility Study and Optimization of Organic Rankine Cycle to Recover Waste Heat of Marine Diesel Engine)

  • 이호기;이동길;박건일
    • 대한조선학회 특별논문집
    • /
    • 대한조선학회 2013년도 특별논문집
    • /
    • pp.103-109
    • /
    • 2013
  • The Present work focuses on application of Organic Rankine Cycle - Waste heat Recovery System (ORC-WHRS) for marine diesel engine. ORC and its combined cycle with the engine were simulated and its performance was estimated theoretically under the various engine operation conditions and cooling water conditions. The working fluid, R245fa, was selected for the consideration of the heat source temperature, system efficiency and safety issues. According to the thermodynamic analysis, ~13.1% of system efficiency of the cycle was performed and it is about 4% of the mechanical power output of the considering Marine Diesel Engine. Also, addition of evaporator and pre-heater were studied to maximize output power of Organic Rankine Cycle as a waste heat recovery system of the marine diesel engine.

  • PDF

증기터빈 열병합 시스템에 대한 에너지 및 엑서지 해석 (Energy and Exergy Analysis of a Steam Turbine Cogeneration System)

  • 조성철
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1397-1405
    • /
    • 2009
  • In recent decades, exergy analysis has been holding spotlight as a useful tool in the design, assessment, optimization, and improvement of energy system. This paper presents the results of the energy and exergy analysis of a steam turbine cogeneration system for industrial complex using two efficiency concepts of conventional one and exergetic one. In order to obtain the destroyed exergy of each component, mathematical analysis is conducted by using exergy balance and the second law of thermodynamics, according as the parameters are changed, such as the ratio of returned process steam, process steam supplied, temperature and pressure of boiler and power. The computer program developed in this study can determine the efficiencies and exergy destroyed at each component of cogeneration system. As a result of this study, a component having the largest destroyed exergy was boiler. And closed and opened feedwater heater had the lowest one. The affects to the cogeneration system due to the variation of process steam flow and return rate of condensed water is shown that the total electric power efficiency(${\eta}_E$) is decreased as increasing the return rate of condensed water under constant process steam flow. As the boiler pressure is increased for the more production of electricity, the efficiency of cogeneration system was decreased.

  • PDF

산화주석 나노선을 이용한 VOCs 센서 (VOCs(Volatile Organic Compounds) sensor using SnO2 nanowires)

  • 황인성;김선중;김윤성;주병권;이종흔
    • 센서학회지
    • /
    • 제17권1호
    • /
    • pp.69-74
    • /
    • 2008
  • VOCs (Volatile Organic Compound) sensors were fabricated using $SnO_2$nanowires-based thin films and its gas sensing behaviors were studied. The $SnO_2$ nanowires synthesized from a thermal evaporation process were dispersed in a solution and the sensor film was prepared by dropping the slurry on the substrate with the electrodes and an embedded heater. The gas response (Ra/Rg, Ra: resistance in air, Rg: resistance in gas) to $30{\sim}40$ ppm Benzene, Ethyl Benzene, o-xylene were in the range of $39{\sim}42$, which were significantly higher than those to 50 ppm of CO, $CH_4$ and $C_3H_8$ ($12{\sim}19$).

Fabrication and Characteristics of Micro-Electro-Mechanical-System-Based Gas Flow Sensor

  • Choi, Ju-Chan;Lee, June-Kyoo;Kong, Seong-Ho
    • 센서학회지
    • /
    • 제20권6호
    • /
    • pp.363-367
    • /
    • 2011
  • This paper proposes a highly-sensitive gas flow sensor with a simple structure. The sensor is composed of a micro-heater for heating the gas medium and a pair of temperature sensors for detecting temperature differences due to gas flow in a sealed chamber on one axis. Operation of the gas flow sensor depends on the transfer of heat through the air medium. The proposed gas flow sensor has the capability to measure gas flow rates <5 $cm^3$/min with a resolution of approximately 0.01 $cm^3$/min. Furthermore, this paper reports some additional experiment results, including the sensitivity of the proposed gas flow sensor as a function of operating current and the flow of different types of gas(oxygen, carbon dioxide, and nitrogen). The fabrication process of the proposed sensor is very simple, making it a good candidate for mass production.

하천수 이용 열원시스템의 경제성 평가 (Economic Evaluation on Energy System Using River Water)

  • 이철구;김종대;임태순;최명식;방승기;함흥돈
    • 한국지열·수열에너지학회논문집
    • /
    • 제9권2호
    • /
    • pp.25-31
    • /
    • 2013
  • It has become very important for unused energy to be used for building air conditioning. Economic evaluation on energy system by using river water as a heat source, which is one of the unused energy, was carried out. The floor area of the building and the distance between heat source equipment and river was assumed $50,000m^2$ and 200 m. General heat source system using absorption chiller-heater was used for comparing to the energy saving system, and payback period method using initial cost and running cost of two systems, was used to perform economic evaluation. According to development of high capacity of water source heat pump which is appropriate for using river water, initial cost for the system has been reduced. Payback period was about 3.2 years, and this period might be shortened if nation's economic support enact.

PERFORMANCE AND EXHAUST GAS CHARACTERISTICS ON DIESEL PARTICULATE FILTER TRAP

  • Oh, S.K.;Baik, D.S.;Han, Y.C.
    • International Journal of Automotive Technology
    • /
    • 제3권3호
    • /
    • pp.111-115
    • /
    • 2002
  • Suddenly increasing numbers of automobiles result in making worse air pollution problems. In particular, the emissions from automobiles affect badly on atmosphere. Nowadays, research on catalyst converter and filter trap as a modem technology is very active because PM is designated as a major cancer material and stringent regulations on this are necessary and required. The ceramic filter is very efficient in reducing particular materials up to 80-90% and is evaluated as a very efficient after-treatment technology. However, it comes with decreased engine performance due to increased back-pressure occurred by thermal crack. In order to solve these problems, several methods are proposed such as fuel additive, electric heater and burner types. This experimental study has been conducted with equipped and unequipped a ceramic filter on a displacement 11,000cc diesel engine and compared in terms of engine performance and emission. To measure the emission, D-13 mode is applied and measured quantities of the exhaust gases, particularly in CO, HC, PM, and NOx. Therefore, this research is focused on the basic mechanism and characteristics on harmful materials generated by ceramic filter.