• Title/Summary/Keyword: air filter media

Search Result 90, Processing Time 0.026 seconds

A Study on the Filter Media and Performance of Intake Air Filter for Vehicular Engine (자동차 흡기 에어필터의 여재 및 성능에 관한 연구)

  • 안병찬;오명도
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.1
    • /
    • pp.8-15
    • /
    • 2004
  • Since the vehicle is regarded as the third living space, the comfortable conditions are required in the passenger compartment. For this reason, customers are concerned about the filtering performances and the importance of filter media has been greatly placed. Therefore the dust holding capacity, the efficiency of these filter media (dry paper, wet paper, non-woven) and the configuration of air filter for vehicle were measured in this study. The following results were obtained on the basis of air filter test. It shows that the thickness and poresize of filter media should be lower for the higher efficiency. The measurement result shows that the performance of round shape filters are higher than the square shape filters. The dust holding capacity of the wet paper and the non-woven paper is higher than the dry paper. As a result, this research can provide an important design parameter and product guidance of the intake air filter for vehicular engine.

Characterization of depth filter media for gas turbine intake air cleaning

  • Park, Young Ok;Hasolli, Naim;Choi, Ho Kyung;Rhee, Young Woo
    • Particle and aerosol research
    • /
    • v.5 no.4
    • /
    • pp.159-170
    • /
    • 2009
  • A depth filter medium was newly designed in order to achieve high collection of dust and low pressure drop in this work. Multilayer depth filter media consist of an upstream layer of highly porous structure which allows particles to pass through and to follow by one or more downstream layers to hold the particles inside the media. For each filter media, flat sheet and pleated module were made of newly developed depth filter media and filter media of commercial products. Commercial depth filter cartridge for gas turbine air intake cleaning were used as reference for filtration area and pleat geometry of pleated modules. This work attempts to evaluate and compare the newly developed depth filter medium and two commercial filter media in terms of filtration parameters such as air permeability, initial pressure drop, particle retention and pressure drop variation with dust loading. According to the close examination the newly developed depth filter showed better performance compared to the commercial depth filter media.

  • PDF

The development of Air-cleaner with Roll Filter inside railroad passenger car (롤필터를 장착한 객차용공기청정장치 개발)

  • Lee, Young-Seop;NamGoong, Seok
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.1297-1301
    • /
    • 2007
  • The indoor air quality guideline of public transportation means was prepared recently. therefore we consider a countermeasure for the indoor air quality improvement of public transportation means. In this work, air-cleaner with roll filter system which developed alternative of indoor air quality guideline. The develpoed roll filter system is two function. the first function harmoniously circulated to heating and cooling air through HVAC system and secondary function removed PM(particluatie matters) which re-scatting to passenger's movement and suppled from outdoor air. Filter media of roll filter system select optimum electret mesh filter out of many filter media. Selected filter media was performanced tests of pressure drop, collection efficiency and dust holding capacity. Finally developed roll filter system was performanced bench test.

  • PDF

Fine Particle Removal by a Vehicle Air Cleaner (차량용 에어클리너의 미세입자 제거특성)

  • Park, Byung-Hyun;Kim, Sang-Bum;Kim, Gyung-Soo;Lee, Sang-Ryul;Lee, Myong-Hwa
    • Journal of ILASS-Korea
    • /
    • v.12 no.2
    • /
    • pp.86-93
    • /
    • 2007
  • There is a growing interest to develop an eco-friendly air cleaner with high performance through a remanufacturing process. Two kinds of polyurethane filter media, a coarse (Filter-A) and a fine filter media (Filer-B), are used in this study to protect a vehicle engine from airborne particles. In order to improve the collection performance of the filters (Filter-A, Filter-B), an oil coating technology on the filter surface was introduced. As a result, inertial force is a dominant collection mechanism for a dry filter media, so that collection efficiency increases with increasing filtration velocity. However, intra-structure change of an oil-coated filter media influences on the collection mechanism, which shows a non-linear collection efficiency curve in terms of filtration velocity. The result shows that the developed filter media are eco-friendly and effective to protect a vehicle engine from airborne particles especially at low filtration velocity.

  • PDF

Performance Test of Air Filter Media (필터여재의 성능평가)

  • Ahn, K.H.;Bae, G.N.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.4
    • /
    • pp.417-426
    • /
    • 1994
  • Filter media performance was evaluated using monodisperse NaCl particles with Differential Mobility Analyzer and Ultrafine Condensation Particle Counter. Low or medium performance filters show that the most penetrating particles size(MPPS) is around $0.3{\mu}m$ in diameter and is shifted to smaller sizes as the filter face velocity increases. However, HEPA and ULPA filters show MPPS is around $0.15{\mu}m$ in diameter and is also shifted to $0.1{\mu}m$ in diameter as the face velocity increases. In case of electret filter, the MPPS is found around $0.04{\mu}m$ region for Boltzmann charge equilibrium particles. There is a tendency of strong collection efficiency decrease for large particles as the face velocity increases on the contrary to the other filters. One of the medium performance filter efficiency was compared with filtration theory and the good agreetment was found in the experimental range.

  • PDF

A Study on Backwashing of Granular Fiters Used in Water Treatment (정수처리를 위한 여과지의 역세척에 관한 연구)

  • Lee, Jung Taek;Ahn, Jong Ho;Choi, Keun Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.13 no.3
    • /
    • pp.61-72
    • /
    • 1999
  • To obtain the experimental data for design and operation of actual filtration processes, a sand filter and three kinds of dual media filters in pilot-plant scale were operated in this study. We analyzed the effect of filter medium composition on the filter performance and the effects of backwash water flow rates, length of stream line and air flow rate on the filter backwash efficiency. We also compared the efficiencies of the combined air-water backwashing and the water backwashing in dual media filters. As the backwash water flow rates or the length of stream line increased, the final turbidity of backwash water was decreased and the filtration duration time after backwash was increased. In the case of the combined air-water backwashing, the backwash water quantity needed for backwashing the dual media filters could be decreased. The total volume of filtered water for the dual media filters during filter run was over three times larger than that for the sand filter. The dual media filters could be operated at a high filtration rate of 360 m/day.

  • PDF

A Study on Antibacterial Assesment of High Efficiency Antibacterial Air Filter (고효율 항균 필터의 항균력 평가에 관한 연구)

  • 권혁구;정진도;류해열;정우성;박덕신
    • Proceedings of the KSR Conference
    • /
    • 2002.05a
    • /
    • pp.549-554
    • /
    • 2002
  • Recently, interest in hygiene has been arouse in the health care field. Consequently, Filters with antibacterial agent applied to improve air quality by sterilizing bacteria, fungi, etc. We actually installed antibacterial air filter containing 2.5wt%Ag zeolite on the air intake route to air-conditioner in passenger cu, and evaluated filter's performance on antibacterial effect. By the microbe liquid spattering method, we found that the antibacterial air filter has notably sufficient antibacterial efficiency against standard strains and wild type strains. Antibacterial effect was observed at whole area of filter media by zone of inhibition test. The evaluation of microbe quantity was conducted through mixing dilution plate culture method. In comparison with ordinary filter, the amount of germs attached on antibacterial air filters was larger. The amount of germs attached on ordinary filters was very small since ordinary filters contained less dust. In comparison in antibacterial air filter with thickness, the amount of germs attached on 9mm filter was smaller than that of on 6mm filter. i.e. thicker filter, superior efficiency.

  • PDF

Comparison of Antibacterial Ability of Air Filter Media Treated with a Natural Antibacterial Agent by Three Treatment Methods (항균성 천연물질의 도포방법에 따른 에어필터 여재의 항균 특성 비교)

  • Park, Sun Young;Jung, Jae Hee;Hwang, Gi Byung;Bae, Gwi-Nam;Kim, Yong Pyo;Nho, Chu Won
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.29 no.2
    • /
    • pp.125-134
    • /
    • 2013
  • Various antimicrobial technologies have been developed to inactivate bioaerosols in indoor environments. In this study, air filter media were treated with a natural antibacterial agent of Sophora flavescens in order to inactivate the bacteria collected on the air filter. Three treatment methods were applied to manufacture the test antibacterial air filter media: electrospray, nebulization and dip-coating methods. In case of electrospray and nebulization processes, the size distribution of aerosolized natural antibacterial agent was measured using a scanning mobility particle sizer. Staphylococcus epidermidis bacteria were aerosolized to test inactivation of the filter media treated with a natural antibacterial agent. The pressure drop and the antibacterial efficiency of the filter media increased with increasing the mass loading of natural antibacterial agent in each treatment method. The antibacterial efficiency per loaded antibacterial agent mass by the electrospray method was the highest and the filter treated by the dip-coating method was the lowest among three treatment methods.

A Study of high Efficiency anti-Bacteria Filters for Passenger Car (객차용 고효율 항균 기능성 필터에 관한 연구)

  • 정우성;박덕신;정진도;류해열
    • Proceedings of the KSR Conference
    • /
    • 2002.10b
    • /
    • pp.975-980
    • /
    • 2002
  • We actually installed antibacterial air filter on the air intake route to air conditioner in passenger car and evaluated filters performance on antibacterial effect. And also, antibacterial effect was observed at whole are of filter media by zone of inhibition test. In the evaluation of antibacterial test, it was shown that the air filter has notably sufficient antibacterial efficiency against ordinary filter.

  • PDF

Test Method for Particle Removal Characteristic of Equipment Fan Filter Unit (EFFU) (Equipment Fan Filter Unit (EFFU)의 Particle 제거 성능평가 방법)

  • Lee, Yang-Woo;Ahn, Kang-Ho
    • Journal of the Semiconductor & Display Technology
    • /
    • v.11 no.2
    • /
    • pp.59-62
    • /
    • 2012
  • This test method covers a procedure for measuring particle removal characteristic of equipment fan filter unit(EFFU) installed inside of semiconductor process equipments, FPD manufacturing equipments and so on. Since EFFU is a combination of air filter and the assembly of fan, motor and frame, the integrity of these parts is very important for the performance of EFFU. So a conventional particle removal test method for air filters is not suitable for EFFU particle removal performance. This test method defines an evaluation method for EFFU which is installed inside an enclosed space to remove particles that are generated inside process equipment. The particle removal performance of EFFUs is usually depending on the performance of filter media and air flow rate. To understand a performance of an EFFU, the filter media characteristic, air flow rate and the integrity of EFFU parts should be considered simultaneously. This test method is intended to demonstrate the system performance of an EFFU and successfully evaluated EFFU performance characteristics.