• 제목/요약/키워드: air duct

검색결과 538건 처리시간 0.025초

복합 덕트시스템의 유량분배에 관한 1차원 해석의 적합성 (Adaptability of one-dimensional analysis for the flow distribution of a complex duct system)

  • 이승철;이재헌
    • 설비공학논문집
    • /
    • 제11권5호
    • /
    • pp.579-587
    • /
    • 1999
  • The flow distribution characteristics in a complex duct system have been investigated in this paper by three means, namely experimental measurement, numerical simulation and the Extended T-method analysis. While the exit flow rates predicted by the three-dimensional CFD calculation and those given by the experiment show a close agreement, the results from the one-dimensional Extended T-method are found to differ from the experiment by -22.2% to 26.3% for the various exits. These discrepancies may be attributed to the underlying limitation concerning the fitting loss coefficients, which assume that the flow in front of the fittings is fully developed. It is proposed that, in order to analyse the three-dimensional flow distributions in a complex duct system by one-dimensional analysis such as the Extended T-method, further Improvements to the fitting loss coefficients should be made.

  • PDF

초고층 공동주택의 입상덕트 환기시스템에서 외기조건과 작동조건에 따른 환기성능평가 (Ventilation Performance According to Outdoor and Operating Conditions of the Vertical Exhaust Duct System in High Riser Public Houses)

  • 김영배;김재홍;성재용;이명호
    • 설비공학논문집
    • /
    • 제23권2호
    • /
    • pp.139-146
    • /
    • 2011
  • The ventilation performance of a vertical exhaust duct system in the high riser public house has been evaluated by a commercial software, Fluid Flow, which solves pressure losses through the duct system including bathroom fans and a hybrid roof fan. During the numerical simulations, outdoor wind condition and stack effects in summer and winter were considered as well as the operating conditions of a basement damper and the roof fan. The results show that the bathroom ventilation in summer is the most unsatisfactory. The opening of the basement damper has a problem that the polluted air in the lower floors is exhausted to the underground parking lot, not to the rooftop. If the basement damper is closed, the exhaust flow rate in the lower floors is not sufficient due to the strong flow resistance in the long vertical duct even though the roof fan is under operating.

밀폐된 컨베이어 벨트 내부의 분진 제거를 위한 환기 시스템의 수치해석적 분석 (Numerical Analysis of Ventilation System for Dust Removal Inside the Enclosed Conveyor Belt)

  • 이예승;정기진;김종민;노정훈
    • 한국입자에어로졸학회지
    • /
    • 제19권2호
    • /
    • pp.43-53
    • /
    • 2023
  • In this study, the ventilation system of the enclosed conveyor belt for coal transportation was evaluated, and the particle removal efficiency according to the ventilation conditions was identified using computational fluid dynamics and particle behavior analysis. The most effective way to remove dust generated inside the closed conveyor belt is to adjust the position of the exhaust port of the duct so that the air is exhausted around the rear of the conveyor belt. And this method seems to work for another narrow and long spaces where air enters in one direction. In addition, when the air flow rate of the each duct was less than 300 CMM, it was efficient to increase the flow rate of the duct located at the rear of the conveyor belt, and when the flow rate of the each duct was higher than 300 CMM, it was efficient to increase the flow rate of the duct located at the front of the conveyor belt.

강제동요시 OWC형 파력발전 공기챔버의 공기반력 실험연구 (A Study of Pneumatic Reaction Force of Air Chamber for an OWC Type Wave Energy Device by Forced Heave Experiments)

  • 홍석원;최학선;류재문;김진하
    • 한국해양공학회지
    • /
    • 제19권3호
    • /
    • pp.11-17
    • /
    • 2005
  • The effect of frequency and amplitude of the OWC (Oscillating Water Column) motion on the nonlinear reaction forces in an air duct are studied experimentally. Experimental owe model is idealized as a simple circular cylinder with an orifice type air duct located at the middle oj the top rid. Reaction forces due to forced heave oscillation are measured and analyzed. By subtracting the effect of inertia forces and restoring forces, pneumatic damping force and added spring force are deduced. The effects of the frequency and amplitude of the heave motion are discussed. Also, the effects of solidity of the duct on the reaction forces are discussed.

강제동용시 OWC형 파력발전 공기챔버의 공기반력 실험연구 (A Study of Pneumatic Reaction Force of Air Chamber for an OWC type Wave Energy Device by Forced Heave Experiments)

  • 최학선;류재문;홍석원;김진하
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2004년도 학술대회지
    • /
    • pp.212-219
    • /
    • 2004
  • The effect of frequency and amplitude of the OWC (Oscillating Water Column) motion on the nonlinear reaction forces in an air duct arc studied experimentally. Experimental OWC model is idealized as a simple circular cylinder with an orifice type air duct located at the middle of the top rid. Reaction forces due to forced heave oscillation are measured and analyzed. By subtracting the effect of inertia forces and restoring forces, pneumatic damping force and added spring force are deduced. The effects of the frequency and amplitude of the heave motion are discussed. Also, the effects of solidity of the duct on the reaction forces are discussed.

  • PDF

덕트설비의 BIM 기반 자동검토를 위한 규칙개발에 관한 연구 (A Study on the Rule Development for BIM-based Automatic Checking in a Duct System)

  • 송종관;조근하;주기범
    • 설비공학논문집
    • /
    • 제25권11호
    • /
    • pp.631-639
    • /
    • 2013
  • This study derives quality checking items in Building Mechanical Systems Design Criteria, and suggests quality criteria to review BIM models in the duct system of an air conditioning system for rule-based automatic checking. First, components for the duct system of an air conditioning system were reviewed, and the quality checking items were drawn from Building Mechanical Systems Design Criteria, through assessment according to object, attribute and relationship composing the BIM model. Second, quality checking types were derived, by analyzing the quality checking items and Rule set of the Solibri Model Checker. Finally, methods of algorithm functioning for checking the BIM models for mechanical systems in computers were drawn, and Elements to comprise the quality checking criteria (rule) were suggested. This study means that that checking items are derived from domestic criteria, and a way for the development process of determining quality checking criteria (rules) is suggested.

수직 온도구배를 갖는 공기 흡입 덕트의 기계적 격리기법 (Mechanical Isolation Method for an Air Intake Duct with Vertical Temperature Gradient)

  • 정치훈
    • 한국추진공학회지
    • /
    • 제20권4호
    • /
    • pp.87-93
    • /
    • 2016
  • 직접 연결식(DC) 고도모의 엔진시험 수행 시, 공기 흡입 덕트와 항공용 엔진 사이에 래버린스 씰이 설치된다. 래버린스 씰은 이 둘을 기계적으로 격리시킴으로써 주추력 및 측추력을 보다 정확하게 측정할 수 있도록 돕는다. 하지만 덕트 내부 공급공기에 높은 수직 온도구배가 발생할 경우, 래버린스 씰의 격리가 파괴되어버린다. 본 논문에서는 이러한 접촉 문제를 해결하기 위한 노력의 일환으로 래버린스 씰 온도 제어장치를 제작/설치하였다. 본 장치를 실제 항공용 엔진시험에 적용한 결과, 높은 수직 온도구배가 생성되어도 래버린스 씰의 격리가 잘 유지되는 것을 확인할 수 있었다.

화력 발전용 보일러 Duct/Fan 시스템의 진동현상에 대한 연구 : Inlet Vortex에 의한 과대진동 사례 (A Study on the Vibration Phenomena of the Duct-fan Systems in Fossil Fueled Boilers: Inlet Vortex Induced Excessive Vibration)

  • 김철홍;주영호;변형현
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 추계학술대회논문집
    • /
    • pp.82-87
    • /
    • 2000
  • During the operation, fatigue failures and cracks of duct plate due to excessive duct vibration occurred in the fan-duct systems of fossil fueled boilers. We measured static pressure variation(pressure pulsation) in the outlet, and also measured vibration at the outlet duct of a centrifugal fan. It was found that strong pressure pulsation caused by the inlet vortex occurred in inlet vane of centrifugal fan in the middle range of vane opening. Thus, excessive duct vibration is caused by strong pressure pulsation. In this paper, it is shown that the frequency and amplitude of pressure pulsation depend mainly on vane opening and are compared with duct vibration. Also, effective solution for reducing pressure pulsation and vibration are presented.

  • PDF

OWC형 파력발전장치 공기실 형상에 따른 왕복유동장 해석 (Oscillating Flow Field Analysis as Shape of Air Chamber in OWC-type Wave Energy Conversion)

  • 문재승;홍기용;신승호;현범수;유황진;박순종
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2006년도 추계학술대회 논문집(제1권)
    • /
    • pp.39-44
    • /
    • 2006
  • 파력발전장치 중 진동수주 (Oscillating Water Column) 형은 3단계 에너지 변환과정을 거치게 된다. 그 중 파랑에너지를 공기에너지로 변환하는 장치인 공기실의 형상을 바꿔가며 그에 따른 성능을 상용 CFD 코드인 FLUENT를 이용한 수치 해석 기법으로 연구하여 보았다. 통상 OWC형 파력발전 장치 전체 성능에 중요한 영향을 미치므로 공기실내의 압력을 최소화하고 터빈 유입유속의 가속화가 용이한 가장 적합한 형상을 정상 및 비정상 해석을 통하여 찾고자 하였다.

  • PDF

OWC형 파력발전장치 공기실 형상에 따른 왕복유동장 해석 (Oscillating Flow Field Analysis as Shape of Air Chamber in OWC-type Wave Energy Conversion)

  • 홍기용;신승호;현범수;류황진;박순종;문재승
    • 한국항해항만학회지
    • /
    • 제31권1호
    • /
    • pp.29-33
    • /
    • 2007
  • 파력발전장치 중 진동수주(Oscillating Water Column)형은 3단계 에너지 변환과정을 거치게 된다. 그 중 파랑에너지를 공기에너지로 변환하는 장치인 공기실의 형상을 바꿔가며 그에 따른 성능을 상용 CFD 코드인 FLUENT를 이용한 수치 해석 기법으로 연구하여 보았다. 통상 OWC형 파력발전장치는 공기실과, 터빈이 설치되는 덕트 간에 효율적인 이유로 급축소 형태를 취하고 있는데 이 때 공기실과 터빈 연결부의 형상이 파력발전 장치 전체 성능에 중요한 영향을 미치므로 공기실내의 압력을 최소화하고 터빈 유입유속의 가속화가 용이한 가장 적합한 형상을 정상 및 비정상 해석을 통하여 찾고자 하였다.