• 제목/요약/키워드: air curing

검색결과 366건 처리시간 0.026초

탄소중립 확보를 위한 친환경 동절기 대체 열원 성능 검증 (Performance Verification of Curing Method in Cold-Weather with Using Energy Saving Electronic Heater for achieving Korean Carbon Neutra)

  • 조만기;김상균;홍성민;박종훈
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 가을 학술논문 발표대회
    • /
    • pp.192-193
    • /
    • 2021
  • Recently, the need to strengthen the Air Environment Conservation Act and secure alternative heat sources during the winter by carbon neutrality policies has been raised. Accordingly, winter construction, which has safety and quality measures, is emerging as an essential factor. It is believed that eco-friendly tropical type electric hot air heaters will be able to solve most of the problems of winter construction at construction sites, especially prevention of suffocation and fire accidents. In addition, as a result of on-site performance verification, it has secured more than the same performance as the existing curing method, and the curing technology can create an eco-friendly and pleasant working environment while considering safety and construction.

  • PDF

Oven형 건조 및 열풍건조에 대한 전도성 잉크의 건조 특성에 관한 연구 (A study on the drying characteristics of conductive ink by oven drying system and the hot-air drying system)

  • 홍승찬;이재효;정길용
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1429-1434
    • /
    • 2009
  • Recently electronic circuit pattern printing technologies like antennas of RFID process are paid attention. oven drying system is being used since drying and curing time of RFID Tag Gravure printing normally takes from 5 minutes and up to 30 minutes long. In this case the parental material which is of a sheet shape is possible, however, for a massive and a continuous production drying and curing process must be done on-line. This research compared and analyzed the an oven type drying device and a traditional hot-air drying device. Considering the experiment result, the cell depth that shows low resistivity, which doesn't consider the pattern difference, is $31{\sim}33{\mu}m$. Also, oven drying system showed some resistivity after around 120 seconds of drying time, and showed much better performance in minimum resistivity compared to the hot-air drying system.

  • PDF

원적외선에 의한 EPDM의 가교 특성 연구 (A Study on Vulcanization of EPDM by Far-infrared)

  • 배종우;김정수;이진혁;정우선;박희창;강동필
    • Elastomers and Composites
    • /
    • 제43권1호
    • /
    • pp.1-7
    • /
    • 2008
  • DSC 및 컴파운드 온도 측정을 통해 원적외선에 의한 EPDM의 가교 반응을 연구하였으며, 특히 동일 조건에서의 열풍에 의한 가교 시험을 통해 원적외선 가교시의 효율성을 평가하였다. 원적외선 및 열풍에 의한 EPDM 컴파운드의 가교도를 분석한 결과, 동일 조건에서 원적외선가교 시료의 가교도가 열풍가교에 비해 높게 나타남을 확인할 수 있었으며, 특히 3 mm 두께 시편의 경우 약 2배가량 높은 가교도를 나타내었다. EPDM 컴파운드의 열전도도의 증가는 원적외선에 의한 가교도를 크게 증가시켰으나, 열풍에 의한 가교도의 변화에는 거의 영향을 주지 못하였다.

Influence of curing condition and carbonation on electrical resistivity of concrete

  • Yoon, In-Seok;Hong, Seongwon;Kang, Thomas H.K.
    • Computers and Concrete
    • /
    • 제15권6호
    • /
    • pp.973-987
    • /
    • 2015
  • The electrical resistivity of air-dried, saturated, and carbonated concretes with different mixture proportions was monitored to evaluate and quantify the influence of the age of the specimen, carbonation, and curing condition. After 28 days of curing, four prepared specimens were stored in a vacuum chamber with 5% $CO_2$ for 330 days to make carbonated specimens. Four of the specimens were placed in water, and four specimens were cured in air until the end of the experiments. It was observed that the electrical resistivity of the carbonated specimens increased as carbonation progressed due to the decrease of porosity and the increase of hydrated products. Therefore, in order to estimate the durability of concrete, its carbonation depth was used as the measurement of electrical resistivity. Moreover, an increase of electrical resistivity for air-dried and saturated concretes was observed as a function of age of the specimen. From the relationship between chloride diffusivity provided by Yoon et al. (2007) and the measurements of electrical resistivity, it is expected that the results well be of significant use in calibrating chloride diffusivity based on regular measurements of electrical resistivity during concrete construction.

양생조건에 따른 플라이애쉬 콘크리트 균열특성에 미치는 영향 (The effect of curing conditions on the cracking properties of flyash concrete)

  • 박종화;이만익;남재현
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.825-828
    • /
    • 2006
  • In this paper, experimental studies are performed to find out properties of crack according to the change of curing conditions of flyash concrete. To study the effect of curing conditions on flyash concrete, slump, bleeding, air content and hydration temperature of fresh concrete are measured according to various curing conditions. In addition, the effect of caring conditions on compressive strength, tensile strength and Plastic drying shrinkage cracking of hardened concrete is also considered.

  • PDF

수용성 접착제 경화 공정용 제습 막 건조기 시스템의 효과 (The Effects of the Dehumidifying Membrane Dryer for the Curing Processes of Waterborne Adhesives)

  • 유서윤;임충선;서봉국
    • 접착 및 계면
    • /
    • 제17권2호
    • /
    • pp.62-66
    • /
    • 2016
  • 수용성 접착제의 경화 공정은 일반적으로 열풍건조기를 대부분 사용하고 있다. 열풍건조기는 열에 의해서만 수용성 접착제를 경화시키는 방법으로서, 충분한 경화를 위해 $100^{\circ}C$ 이상의 높은 온도와 최소 20 min 이상의 경화 공정을 요구하는 단점을 가지고 있다. 경화 과정 중에 온도가 너무 높을 경우, 접착제의 점도가 낮아져 접착에 방해가 될 수 있으며, 경화 과정 중에 발생하는 수분에 의해 경화 조건이 일정하게 유지되기 어렵다. 본 연구에서는 제습 막 건조기 시스템을 활용하여, 수용성 접착제의 경화 공정을 일정하게 유지시키고 공정 중의 제습을 통해 건조공기의 공급으로 경화시간을 단축하고자 한다. 제습 막 건조기 시스템을 활용한 최적의 경화 조건을 찾고, 제습 막 건조기 시스템의 효과를 확인하기 위하여, 제습 막 건조기와 강제순환 건조기를 적용한 경화 과정을 통해 접착력(peel strength)을 측정하여 비교 분석해 보았다.

양생조건이 고로슬래그 미분말을 혼입한 시멘트 콘크리트의 염화물이온 확산계수에 미치는 영향 (Effect of Curing Condition on the Chloride ion Diffusion Coefficient in Concrete with GGBFS)

  • 박장현;이한승
    • 한국건축시공학회지
    • /
    • 제19권5호
    • /
    • pp.421-429
    • /
    • 2019
  • 양생조건이 GGBFS를 사용한 시멘트 콘크리트의 염화물이온 확산계수에 미치는 영향에 대한 연구를 진행하였다. 양생조건은 기중양생 ($20{\pm}2^{\circ}C$, RH $60{\pm}5%$)과 수중양생 ($20{\pm}2^{\circ}C$)으로 구분하였으며, GGBFS 치환율은 0%(대조군), 30%, 60%로 구분하여 3가지 배합의 콘크리트를 W/B 40%, 50%, 60%로 구분하여 제작하였다. 시험은 콘크리트 압축강도평가, 염화물이온확산계수 평가를 실시하였다. 콘크리트의 압축강도는 GGBFS 치환율이 증가할수록 수중양생 대비 기중양생 시험체의 압축강도의 발현율이 감소하였다. 염화물이온확산계수 측정결과 GGBFS치환율이 증가할수록 염화물이온 확산계수가 감소하였지만, 수중양생대비 기중양생 시험체의 콘크리트 염화물이온 확산계수는 증가하여 최대 111%까지 증가하는 것을 확인하였다.

UV-LED 경화형 칼라 코팅의 경화특성 연구 (Curing Properties of UV-LED Curable Color Coating)

  • 신찬호;김종구;홍진후;안태정;김현경
    • 접착 및 계면
    • /
    • 제13권1호
    • /
    • pp.31-37
    • /
    • 2012
  • 본 연구는 UV-LED 경화형 칼라코팅에 대한 경화특성에 관한 것으로, 특히 UV-LED 파장(365, 395, 405 nm), 불활성 기체, 증감제 및 Dual curing에 따른 경화성을 평가하였다. 광경화 과정과 코팅 도막의 Film-air (FA) interface와 Film-substrate (FS) interface에서 존재하는 미반응 아크릴레이트에 대한 평가는 Photo-DSC와 FT-IR/ATR을 이용하여 각각 조사하였다. Photo-DSC 측정 결과 발열량과 전환율은 405 nm UV-LED를 이용한 코팅 시스템의 경우가 395 및 365 nm UV-LED를 사용한 경우보다 높게 나타났다. UV-LED 경화형 시스템은 전반적으로 Film-substrate (FS) interface의 경화도가 높은 것으로 나타나 후막경화가 우수함을 알 수 있었으나, Film-air (FA) interface의 표면 경화도는 산소저해 현상으로 인해 매우 낮음을 FT-IR/ATR 결과를 통해 확인하였다. 이러한 낮은 표면 경화도는 불활성 기체인 질소를 사용하거나 Dual curing 방법을 도입함으로써 개선할 수 있었다.

싸이클로헥센 증기 공정에 의한 산소량이 적은 실리콘카바이드 섬유의 개발 (Development of Polymer-derived Silicon Carbide Fiber with Low Oxygen Content Using a Cyclohexene Vapor Process)

  • 윤병일;최우철;김명주;김재성;김정일;강홍구
    • 한국군사과학기술학회지
    • /
    • 제20권5호
    • /
    • pp.620-632
    • /
    • 2017
  • A chemical vapor curing method(CVC) was developed to cure polycarbosilane(PCS) fibers by using cyclohexene vapour as a non-oxygen active reactant, instead of air in oder to prepare the silicon carbide(SiC) fiber with low oxygen content. A cross-linked PCS fibers by cyclohexene vapor showed a completely different variation in IR spectra in comparison to the air-cured PCS fiber. CVC method resulted in less than 3 wt% in oxygen content. In this experiment conditions, The average tensile strength and modulus of SiC fiber obtained by CVC had 1995 MPa and 183 GPa respectively, which is higher than that of SiC fiber prepared by air-curing process.

바텀애시 경량골재 콘크리트 압축강도에 대한 기포 혼입률 및 양생온도의 영향 (Effect of Foam Volume ratio and Curing Temperature on Compressive Strength of Lightweight using Bottom Ash Aggregates)

  • 이광일;양근혁
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 춘계 학술논문 발표대회
    • /
    • pp.168-169
    • /
    • 2019
  • This study examined the effect of foam volume ratio and curing temperature the air dry density and compressive strength of lightweight concrete using bottom ash. Test results showed that the lightweight concrete possessed the compressive strength of 3.4~22.7 MPa at the air dry density of 1,041~1,583 kg/m3.

  • PDF