• 제목/요약/키워드: air conditioning

검색결과 8,503건 처리시간 0.037초

Urban Forest Monitoring in Korea since 1991: Case Study on Daegu Metropolitan City

  • Kwon, Jino;Cho, HyunJe;Choi, MyoungSnb;Park, Chan-Ryul;Sung, Joo-Han;Cho, Jae-Hyoung;Kim, Sunhee;Park, Jonggyun;Oh, Jeong-Hak
    • 한국산림과학회지
    • /
    • 제95권5호
    • /
    • pp.591-594
    • /
    • 2006
  • To have better urban forests in future we are focusing on two major issues like other countries. How we could have more urban forest-quantitative approach-against the expanding of urbanization, and how we could produce better urban forest-qualitative approach-to give a chance in contact with better nature for urban people. Prime surveys on urban forests have been carried out in 6 major cities since 1991, and the city of Daegu which is located on the east southern area of Korea have been case studied for qualitative approaches during last 3 years. Major species of the remnant forests were Pinus densiflora, Pinus rigida, Pinus thunbergii and Robinia pseudoacacia. Approximately 20% of the surveyed forests were lost their structure as forests caused by illegal farming, facilities and as the bare ground by excessive visitors. Generally speaking the condition of forests for biotope was very poor in overall. From two years data of monitoring of birds, we found that wooded parkways and woodland squares had more species than street tree areas. Nests were found mainly on the branch of Zelkova serrata, Pinus densiflora and Quercus myrsinaefolia. The size of urban forests mainly determined the species richness of birds. According to the oxygen output and carbon input by photosynthesis measurement, the capability was in order of Platanus occidentalis, Zelkova serrata and Ginko biloba. Air conditioning effects of trees through transpiration measurement was found and the quality of forests also related to the reducing of urban heat-island.

건축 공간적 가변성에 대응하는 설비 시스템에 관한 연구 (Research and study on facility system good enough to address the changing aspects of building space)

  • 이재용;윤해동;김석완
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.554-559
    • /
    • 2006
  • The currently common housing is obviously going to be under the reconstruction in just $20{\sim}30$ years, with the failure to satisfy the improvement of national income, diversification and advance of national demand. But, reckless and random reconstruction Induce the serious problem of environmental pollution involving the loss of national treasury and excess materials of constructions. In order to address such problem, the common housing of longevity, which can adequately cope with the changes of times and tastes of inhabiters, in the future, is arising as an alternative. Recently, the groundbreaking phase of common housing is also being considered as another alternative to resolve such problem. The common housing of longevity has an advantage to create a free and comfortable space in accordance with the tastes of inhabiters, as well as expanding the durability of building. But, the current facility system has an inability to deal with the sort of housing. Thus, the research paper is designed to make an analysis on problems of common housing in South Korea, which has made it difficult to handle a changing space, and based on the analysis, the paper is intended to make a review on the future-oriented facility service appropriate enough to deal with the changing aspects of space.

  • PDF

Numerical Analysis on the Flow Characteristics in Steam Ejector

  • Shin, You-Sik;Jin, Zhen-Hua;Chun, You-Sin;Lee, Sang-Chul;Jeong, Hyo-Min;Chung, Han-Shik
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.749-754
    • /
    • 2006
  • This study performed of a water cooling system by using a steam ejector and jet condenser to drop the temperature of the water in aquafarm by about $5^{\circ}C$ from $25^{\circ}C$ or higher in this research, to replace the present water cooling system, Ive focused on a water cooling system operated by latent heat of evaporation, thus this system needs a vacuum pressure to evaporate the water in enclosed tank. The water cooling effects are dependent on the vacuum pressure in the enclosed tank, and the cooling water is generated by evaporation. As the experimental results, the absolute vacuum pressure obtained was about $5{\sim}8mmHg$ using a steam driven ejector with jet condenser in experiments. The obtained results are respectively ${\Delta}T=7^{\circ}C$, ${\Delta}T=5^{\circ}C$ and ${\Delta}T=5.5^{\circ}C$ at heat exchanger flow rate 4L/M. The obtained results are respectively ${\Delta}T=5.5^{\circ}C$, ${\Delta}T=5.5^{\circ}C$ and ${\Delta}T=5.5^{\circ}C$ at heat exchanger flow rate 4.5L/M.

  • PDF

세관을 이용한 Tube-in-Tube 열교환기내 R-22, R-407C 및 R-410A 응축열전달 특성 (Condensation Heat Transfer Characteristics of Tube-in-Tube Heat Exchanger using Small Diameter Tubes with R-22, R-407C and R-410A)

  • 박우종;최광일;박기원;오종택
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.657-662
    • /
    • 2006
  • The present paper dealt with an experimental study of condensation heat transfer coefficients with refrigerant R-22, R-407C and R-410A, and was focused on pressure gradient and heat transfer coefficient in horizontal tube-in-tube heat exchangers using inner diameter of 4 mm, 3 mm and 2 mm in a 16.91 mm tube and length of 3,000 mm. Experiments were performed at inlet saturation temperature of 35 to $45^{\circ}C$ and mass flux ranges from 200 to $600 kg/m^2s$. The pressure gradient with inner tube diameter of 4.0 mm is higher 2.5 times than that of 8.0 mm. In tube-in-tube HEX, the pressure gradient of R-410A were lower than those of R-22 and R-407C. The condensation heat transfer coefficients increased with mass flux increase, but they decreased with saturation temperature increased. Condensation heat transfer coefficients of R-410A were a little higher than those of R-22 and R-407C. The condensation heat transfer coefficients of tube-in-tube HEX were about 40% higher than those of double tube HEX.

  • PDF

나노 윤활유를 이용한 스크롤 압축기 스러스트 베어링의 윤활특성 평가 (Performance Evaluation of Nano-Lubricants at Thrust Slide-Bearing of Scroll Compressors)

  • 조상원;김홍석;안영철;이정언;이재관;이형국;이병철;김동한;박진성
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.1219-1224
    • /
    • 2006
  • This paper presents the friction and anti-wear characteristics of nano-oil with n mixture of a refrigerant oil and carbon nano-particles in the thrust slide-bearing of scroll compressors. Frictional loss in the thrust slide-bearing occupies a large part of total mechanical loss in scroll compressors. The characteristics of friction and anti-wear Lising nano-oil is evaluated using the thrust bearing tester for measuring friction surface temperature and the coefficient of friction at the thrust slide-bearing as a function of normal loads up to 4,000 N and orbiting speed up to 3,200 rpm. It is found that the coefficient of friction increases with decreasing orbiting speed and normal force. The friction coefficient of carbon nano-oil is 0.015, while that of pure oil is 0.023 under the conditions of refrigerant gas R-22 at the pressure of 5 bars. It is believed that carbon nano-particles can be coated on the friction surfaces and the interaction of nano-particles between surfaces can be improved the lubrication in the friction surfaces. Carbon nano-oilenhances the characteristics of the anti-wear and friction at the thrust slide-bearing of scroll compressors.

  • PDF

증기압력 변화에 따른 증기 이젝터의 성능에 관한 연구 (A Study on the Performance of Steam Ejector by Variation of Steam Pressure)

  • 전유신;신유식;;정효민;정한식
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.761-766
    • /
    • 2006
  • This paper describes a study on the performance of steam ejector by variation of steam pressure. Water temperature is especially important for good qualify of fish in an inland aquafam. In summer season, the water temperature increases above $25^{\circ}C$, but for good quality breeding or fish is the maintenance of optimum aquafam temperature by about $20^{\circ}C$. Therefore it is needed to drop the water temperature to provide suitable conditions of fish growth. There are many kinds of cooling system, in this study using steam ejector. After cooling the water in vacuum tank with the steam ejector then circulate this water to inland aquafam. In this way to minimizes fish stress that it is caused by water temperature. The objective of research confirms the difference of the case which there is no water in the vacuum tank and has water in the vacuum tank. The purpose of this paper is to examine the effects on the performance of steam ejector by variation of steam pressure.

  • PDF

수평미세관내 R-290의 비등열전달 특성 (Boiling Heat Transfer Characteristics of R-290 in Horizontal Minichannel)

  • 최광일;;오종택
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.68-73
    • /
    • 2006
  • The present paper deals with an experimental study of boiling heat transfer characteristics of R-290, and is focused on pressure gradient and heat transfer coefficient of the refrigerant flow inside horizontal smooth minichannel with inner diameter of 3.0 mm and length of 2000 mm. The direct heating method applied for supplying heat to the refrigerant where the test tube was uniformly heated by electric current which was applied to the tube wall. The experiments were conducted with R-290 with purity of 99.99% at saturation temperature of 0 to $10^{\circ}C$. The range of mass flux is $50{\sim}250kg/m^2s$ and heat flux is $5{\sim}20kW/m^2$. The heat transfer coefficients of R-290 increases with increasing mass flux and saturation temperature, wherein the effect of mass flux is higher than that of the saturation temperature, whereas the heat flux has a low effect on increasing heat transfer coefficient. The significant effect of mass flux on heat transfer coefficient is shown at high quality, the effect of heat flux on heat transfer coefficient at low quality shows a domination of nucleate boiling contribution. The heat transfer coefficient of the experimental result was compared with six existing heat transfer coefficient correlation. Zang et al.'s correlation(2004) gave the best prediction of heat transfer coefficient.

  • PDF

Zeta-potential을 이용한 이성분 나노유체의 분산안정도 측정 (Measurement of distribution stability of binary nanofluids by zeta-potential)

  • 이강일;정청우;김현준;정진희;강용태
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.52-57
    • /
    • 2006
  • This study investigates the distribution stability of binary nanofluids where binary mixtures such as $NH_3/H_2O$ and $H_2O/LiBr$ solution are used as a base fluid. When a little amount of certain nanosized particles is added into a basefluid, the thermal conductivity of that mixture increases greatly. Such mixtures are named 'nanofluids' where nano-particles should be distributed stably and uniformly so the distribution stability of nanoparticles in nanofluids is one of the most important factors for nanofluid application. Therefore, binary nanofluids in which binary mixtures are applied as the basefluids are considered as working fluids. The kind and the concentration of nanoparticles, and the concentration of ammonia are considered as the key parameters. The objectives of this paper are to visualize the dispersed status of particles in binary nanofluids and to find the effect of key parameters on the distribution stability in the ammonia absorption system.

  • PDF

지역난방 열사용시설 자동제어시스템 개선을 통한 회수온도 저감 연구 (The Decrease of Return Temperature by Improvement of the Consumer's Control System in District Heating)

  • 하승규;김연홍;이훈
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.245-251
    • /
    • 2006
  • The main idea of this study is to turn attention on the question of good cooling ability of customer substations in large district heating networks. The main reason for that is based on our experience that the optimization of district heating very often is directed toward production, whereas questions of optimal distribution are neglected if only the necessary load can be supplied and the customer's request for comfort is met. Our view is that low return temperature(operational temperature differences, ${\Delta}T$) in district heating systems is an Important feature for efficient net operation and gives both economic and operational benefits to the district heating supplier Furthermore, it is as well a prerequisite for meeting the customers demand for reliable supply of the heat load. However, in many practical cases we have seen that district heating return temperatures are higher than necessary. Hence, the aim of the study is to propose and verify a method for detection of the most critical consumers of the net and to identify the reasons for resulting high return temperature. From the results, temperature control system is presented as one of the most important reason of high return temperature in DH networks.

  • PDF

지열히트펌프시스템의 설치 및 운영이 토양.지하수에 미치는 영향에 대한 고찰 (A Review on Potential Effects of Installation and Operation of Ground Source Heat Pumps on Soil and Groundwater Environment)

  • 조윤주;이진용;임수영;홍경표
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제14권3호
    • /
    • pp.22-31
    • /
    • 2009
  • 최근 에너지 위기와 지구 온난화의 영향으로 국내에서 건물의 냉난방에 지열에너지를 비롯한 재생에너지의 사용이 증가하고 있다. 지열히트펌프시스템은 지금까지 지구상에서 가장 환경친화적인 냉난방 공조설비의 하나로 알려져 있다. 그러나 지열히트펌프시스템의 설치 및 운영이 토양 지하수환경에 미칠 수 있는 몇 가지 영향들에 대한 보고가 있다. 이들 영향으로는 주로 지열히트펌프시스템의 부적절한 설치, 운영 및 폐쇄와 관련된다. 본 논문에서는 지열히트 펌프시스템이 토양 지하수환경에 미칠 수 있는 영향에 관하여 고찰하였다.