• Title/Summary/Keyword: after-school system

Search Result 4,034, Processing Time 0.045 seconds

A Study on e-Mentoring system Design for Guiding Learning After School (방과 후 학습지도를 위한 전자멘토링 시스템 설계방안)

  • Kim, Sung-Wan
    • Journal of the Korea Society of Computer and Information
    • /
    • v.12 no.5
    • /
    • pp.303-311
    • /
    • 2007
  • The instruction based on mass production system has contributed to the materialistic abundance, but it caused the innate target of education, development of 'holistic human beings' to be lost. Accordingly, the mentoring has been highlighted as an alternative instructional method because it can support learners in the aspect of cognitive and affective domain. On the other hand, as an effort of overcoming time and place constraints of face-to-face mentoring, e-mentoring is being required. This research aims to propose the e-mentoring system design plan for guiding learning after school, which may support face-to-face mentoring. Based on literature reviews, the direction of design was set and the necessary functions were drawn. e-Mentoring system design plan proposed in this article may be helpful to practitioners who are interested in the enhancement of effectiveness and efficiency of mentoring programs. Also it is required that more practical study should be performed for developing the system and testing its effectiveness.

  • PDF

Monitoring and Characterization of Bacterial Contamination in a High-Purity Water System Used for Semiconductor Manufacturing

  • Kim, In -Seop;Lee, Geon-Hyoung;Lee, Kye-Joon
    • Journal of Microbiology
    • /
    • v.38 no.2
    • /
    • pp.99-104
    • /
    • 2000
  • Hydrogen peroxide has been used in cleaning the piping of an advanced high-purity water system that supplies ultra-high purity water (UHPW) for 16 megabyte DRAM semiconductor manufacturing. The level of hydrogen peroxide-resistant bacteria in UHPW water was monitored prior to and after disinfecting the piping with hydrogen peroxide. Most of the bacteria isolated after hydrogen peroxide disinfection were highly resistant to hydrogen peroxide. However, the percentage of resistant bacteria decreased with time. The hydrogen peroxide-resistant bacteria were identified as Micrococcus luteus, Bacillus cereus, Alcaligenes latus, Xanthomonas sp. and Flavobacterium indologenes. The susceptibility of the bacteria to hydrogen peroxide was tested as either planktonic cells or attached cells on glass. Attached bacteria as the biofilm on glass exhibited increased hydrogen peroxide resistnace, with the resistance increasing with respect to the age of the biofilm regrowth on piping after hydrogen peroxide treatment. In order to optimize the cleaning strategy for piping of the high-purity water system, the disinfecting effect of hydrogen preoxide and peracetic acid on the bacteria was evaluated. The combined use of hydrogen peroxide and peracetic acid was very effective in killing attached bacteria as well as planktonic bacteria.

  • PDF

A Prototype of Robotic External Fixation System for Surgery of Bone Deformity Correction

  • Kim, Yoon-Hyuk;Joo, Sang-Min;Lee, Soon-Geul
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.2448-2450
    • /
    • 2005
  • A robotic external fixation system for the surgery of bone deformity correction was developed to simulate the execution process of mal-unioned femur by the adjustment of the joints of the fixation system. An inverse kinematics analysis algorithm was developed to calculate the necessary rotations and translations at each joint of the robotic system. The computer graphic model was developed for validation of the analysis result and visualization of the surgical process. For given rotational and angular deformity case, the surgical execution process using the robotic system was well matched with the pre-operative planning. The final residual rotational deformities were within $1.0^{\circ}{\sim}1.6^{\circ}$ after surgical correction process. The presented robotic system with computer-aided planning can be useful for knowledge-based fracture treatment and bone deformity correction under external fixation.

  • PDF

An Efficient Implementation of Tornado Code for Fault Tolerance

  • Lei, Jian-Jun;Kwon, Gu-In
    • Journal of Korea Spatial Information System Society
    • /
    • v.11 no.2
    • /
    • pp.13-18
    • /
    • 2009
  • This paper presents the implementation procedure of encoding and decoding algorithms for Tornado code that can provide fault tolerance for storage and transmission system. The degree distribution satisfying heavy tail distribution is produced. Based on this distribution, a good random irregular bipartite graph is attained after plenty of trails. Such graph construction is proved to be efficient, and the experiments also demonstrate that the implementation obtains good performance in terms of decoding overhead.

  • PDF

Transpedal lymphatic embolization for lymphorrhea at the graft harvest site after coronary artery bypass grafting

  • Cha, Jung Guen;Lee, Sang Yub;Hong, Jihoon;Ryeom, Hun Kyu;Kim, Gab Chul;Do, Young Woo
    • Journal of Yeungnam Medical Science
    • /
    • v.38 no.1
    • /
    • pp.74-77
    • /
    • 2021
  • Lymphorrhea is a rare but potentially severe complication that occurs after various surgical procedures. Untreated lymphorrhea may lead to wound dehiscence, infection, and prolonged hospital stay. Currently, there is no standard effective treatment. Early management usually includes leg elevation, drainage, and pressure dressing. However, these methods are associated with prolonged recovery and high recurrence rates. We report a case of lymphorrhea from a calf wound after endoscopic great saphenous vein (GSV) harvesting for coronary artery bypass grafting (CABG). The patient presented with intractable oozing from the postoperative wound on the right calf. Lymphorrhea persisted for 6 weeks despite negative-pressure wound therapy with a long-acting somatostatin. We performed unilateral pedal lymphangiography that confirmed wound lymphorrhea, followed by glue embolization. No recurrence was observed after 8 months of follow-up. This case report demonstrates the successful use of lymphangiography with glue embolization in the control of lymphorrhea after GSV harvesting for CABG.

Cerebral Vasospasm with Delayed Ischemic Neurologic Deficit after Unruptured Aneurysm Surgery : Report of Two Cases and Review of the Literature

  • Kim, Myungsoo;Son, Wonsoo;Kang, Dong-Hun;Park, Jaechan
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.4
    • /
    • pp.665-670
    • /
    • 2021
  • Symptomatic cerebral vasospasm (CVS) and delayed ischemic neurologic deficit (DIND) after unruptured aneurysm surgery are extremely rare. Its onset timing is variable, and its mechanisms are unclear. We report two cases of CVS with DIND after unruptured aneurysm surgery and review the literature regarding potential mechanisms. The first case is a 51-year-old woman with non-hemorrhagic vasospasm after unruptured left anterior communicating artery aneurysm surgery. She presented with delayed vasospasm on postoperative day 14. The second case is a 45-year-old woman who suffered from oculomotor nerve palsy caused by an unruptured posterior communicatig artery (PCoA) aneurysm. DIND with non-hemorrhagic vasospasm developed on postoperative day 12. To our knowledge, this is the first report of symptomatic CVS with oculomotor nerve palsy following unruptured PCoA aneurysm surgery. CVS with DIND after unruptured aneurysm surgery is very rare and can be triggered by multiple mechanisms, such as hemorrhage, mechanical stress to the arterial wall, or the trigemino-cerebrovascular system. For unruptured aneurysm surgery, although it is rare, careful observation and treatments can be needed for postoperative CVS with DIND.

Influence of porcelain veneering on the marginal fit of Digident and Lava CAD/CAM zirconia ceramic crowns

  • Pak, Hyun-Soon;Han, Jung-Suk;Lee, Jai-Bong;Kim, Sung-Hun;Yang, Jae-Ho
    • The Journal of Advanced Prosthodontics
    • /
    • v.2 no.2
    • /
    • pp.33-38
    • /
    • 2010
  • PURPOSE. Marginal fit is a very important factor considering the restoration's long-term success. However, adding porcelain to copings can cause distortion and lead to an inadequate fit which exposes more luting material to the oral environment and causes secondary caries. The purpose of this study was to compare the marginal fit of 2 different all-ceramic crown systems before and after porcelain veneering. This study was also intended to verify the marginal fit of crowns originated from green machining of partially sintered blocks of zirconia (Lava CAD/CAM system) and that of crowns obtained through machining of fully sintered blocks of zirconia (Digident CAD/CAM system). MATERIALS AND METHODS. 20 crowns were made per each system and the marginal fit was evaluated through a light microscope with image processing (Accura 2000) at 50 points that were randomly selected. Each crown was measured twice: the first measurement was done after obtaining a 0.5 mm coping and the second measurement was done after porcelain veneering. The means and standard deviations were calculated and statistical inferences among the 2 groups were made using independent t-test and within the same group through paired t-test. RESULTS. The means and standard deviations of the marginal fit were $61.52{\pm}2.88{\mu}m$ for the Digident CAD/CAM zirconia ceramic crowns before porcelain veneering and $83.15{\pm}3.51{\mu}m$ after porcelain veneering. Lava CAD/CAM zirconia ceramic crowns showed means and standard deviations of $62.22{\pm}1.78{\mu}m$ before porcelain veneering and $82.03{\pm}1.85{\mu}m$ after porcelain veneering. Both groups showed significant differences when analyzing the marginal gaps before and after porcelain veneering within each group. However, no significant differences were found when comparing the marginal gaps of each group before porcelain veneering and after porcelain veneering as well. CONCLUSION. The 2 all-ceramic crown systems showed marginal gaps that were within a reported clinically acceptable range of marginal discrepancy.

DNA Damage in Lymphocytes after Hair Dyeing and Related Factors among Women Volunteers (일부 자원 여성에서 모발염색 후 림프구의 DNA손상과 관련 요인)

  • Cho, Jin-A;Oh, Eun-Ha;Sull, Dong-Geun;Lee, Eun-Il
    • Journal of Preventive Medicine and Public Health
    • /
    • v.35 no.4
    • /
    • pp.275-281
    • /
    • 2002
  • Objectives : To evaluate the DNA damage by hair dyeing in human lymphocytes Methods : Comet assays were carried out to evaluate the DNA damage in lymphocytes by hair dyeing. Twenty subjects were selected from women volunteers whose age ranged from 55 to 67 year old. All subjects had no smoking history. Blood samples were collected before and 6 hours after hair dyeing. DNA damage was evaluated by means of the tail moments, which were quantified by a KOMET 4.0 image analysis system. Results : The tail moments before hair dyeing showed no significant differences among subjects except for the high frequency group. The mean values of the tail moments in subjects with low and high frequencies of hair dyeing were 1.39 and 1.77, respectively (p<0.05). The tail moments after hair dyeing increased significantly, The mean values of tail moments in subjects before and after hair dyeing were 1.45 and 1.79, respectively (p<0.01). However, the difference levels of DNA damage in lymphocytes before and after hair dyeing were found to be slightly lower in both the dietary supplement taking group and high frequency group. Conclusions : The high frequency group appears to have a higher level of DNA damage than the low frequency group before hair dyeing. DNA damage in lymphocytes was found to be significantly higher in the volunteers after hair dyeing. In this study, the related factors such as high frequency and taking dietary supplements appeard to reduce DNA damage in lymphocytes after hair dyeing.

Seismic response of spring-damper-rolling systems with concave friction distribution

  • Wei, Biao;Wang, Peng;He, Xuhui;Jiang, Lizhong
    • Earthquakes and Structures
    • /
    • v.11 no.1
    • /
    • pp.25-43
    • /
    • 2016
  • The uneven distribution of rolling friction coefficient may lead to great uncertainty in the structural seismic isolation performance. This paper attempts to improve the isolation performance of a spring-damper-rolling isolation system by artificially making the uneven friction distribution to be concave. The rolling friction coefficient gradually increases when the isolator rolls away from the original position during an earthquake. After the spring-damper-rolling isolation system under different ground motions was calculated by a numerical analysis method, the system obtained more regular results than that of random uneven friction distributions. Results shows that the concave friction distribution can not only dissipate the earthquake energy, but also change the structural natural period. These functions improve the seismic isolation efficiency of the spring-damper-rolling isolation system in comparison with the random uneven distribution of rolling friction coefficient, and always lead to a relatively acceptable isolation state even if the actual earthquake significantly differs from the design earthquake.

A Study on Drive Characteristic of Photovoltaic to consider temperature compensation account. (온도보정계수를 고려한 태양광발전 운전특성연구)

  • Lee Jeong-il;Yoon Jeong-Phil;Yu Hee-Ok;Yoon Hyung-Sang;Cha In-Su
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.63-66
    • /
    • 2001
  • Photovoltaic System does military exploit that use heliometer light and is clearness source of energy. Photovoltatic System is no noise, shock among is several Substitute energy and after establishment maintenance having simple special quality, is applied in many fields. However, while Photovoltatic System is having these advantage, but react sensitively in effect of Photovoltaic scanning Quantity, temperature change etc.. surrounding environment, when did not satisfy condition, express indefinite output price. Consider voltage$\cdot$current output measurement value and temperature revision calculation by temperature change of existing photovoltaic system and change of output price of when did Simulation analyzed comparison.

  • PDF