• Title/Summary/Keyword: aes

Search Result 1,426, Processing Time 0.024 seconds

Personal Data Security in Recruitment Platforms

  • Bajoudah, Alya'a;AlSuwat, Hatim
    • International Journal of Computer Science & Network Security
    • /
    • v.22 no.6
    • /
    • pp.310-318
    • /
    • 2022
  • Job offers have become more widespread and it has become easier and faster to apply for jobs through electronic recruitment platforms. In order to increase the protection of the data that is attached to the recruitment platforms. In this research, a proposed model was created through the use of hybrid encryption, which is used through the following algorithms: AES,Twofish,. This proposed model proved the effectiveness of using hybrid encryption in protecting personal data.

Implementation of AES and ARIA algorithm with Secure Structure for Power Analysis using LFSR Masking

  • Kang, Young-Jin;Kim, Ki-Hwan;Lee, Hoon Jae
    • Journal of the Korea Society of Computer and Information
    • /
    • v.25 no.1
    • /
    • pp.79-86
    • /
    • 2020
  • In this paper, we analyzed the case vulnerable to the power analysis attack of the ARIA algorithm and AES algorithm. Through this, we propose an algorithm with a safe structure for power analysis and prove through experiment. The proposed technique is a masking method using LFSR with a cyclic structure. To verify this, 1000, 2000, and 4000 power traces were collected, and the corresponding results are shown and proved. We used ATmega328 Chip for Arduino Uno for the experiment and mounted each algorithm. In order to measure the power consumption, a resistor was inserted and then proceeded. The analysis results show that the proposed structure has a safe structure for power analysis. In the future, we will study ways to lead to performance enhancement.

Development and Round Robin Test of Pt-Co Alloy Thin Film Standard Materials for the Quantification of Surface Compositional Analysis (표면 조성분석의 정량화를 위한 Pt-Co 합금박막 표준시료의 개발 및 공동분석)

  • 김경중
    • Journal of the Korean Vacuum Society
    • /
    • v.7 no.3
    • /
    • pp.176-186
    • /
    • 1998
  • Pure Pt, Co and their alloy thin films with three different compositions (Pt66-Co34, Pt40-Co60 and Pt18-Co82) were deposited on Si(100) wafers and proposed as a set of certified reference materials (CRM) for the quantification and standardization of surface compositional analysis. The compositions of the binary alloy thin films were controlled by in-situ XPS analyses and the certified compositions of the films have been determined by ICP-AES and RBS analyses after thin film growth. Through comparison of the compositions determined by in-situ XPS with those by ICP, relatively accurate compositions could be obtained with a matrix effect correction. Standard deviations of XPS and AES round robin tests with the Pt-Co alloy thin films were large up to about 4%. On the other hand, the average compositions of the Pt-Co alloy thin films by two methods were in a good agreement within 1%. The formation of a Pt rich surface layer by ion beam sputtering indicates that the surface modification by preferential sputtering must be understood for a better compositional analysis.

  • PDF

Power Analysis Attack of Block Cipher AES Based on Convolutional Neural Network (블록 암호 AES에 대한 CNN 기반의 전력 분석 공격)

  • Kwon, Hong-Pil;Ha, Jae-Cheol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.5
    • /
    • pp.14-21
    • /
    • 2020
  • In order to provide confidential services between two communicating parties, block data encryption using a symmetric secret key is applied. A power analysis attack on a cryptosystem is a side channel-analysis method that can extract a secret key by measuring the power consumption traces of the crypto device. In this paper, we propose an attack model that can recover the secret key using a power analysis attack based on a deep learning convolutional neural network (CNN) algorithm. Considering that the CNN algorithm is suitable for image analysis, we particularly adopt the recurrence plot (RP) signal processing method, which transforms the one-dimensional power trace into two-dimensional data. As a result of executing the proposed CNN attack model on an XMEGA128 experimental board that implemented the AES-128 encryption algorithm, we recovered the secret key with 22.23% accuracy using raw power consumption traces, and obtained 97.93% accuracy using power traces on which we applied the RP processing method.

A study on the deposition characteristics of the hi thin films deposited ionized cluster beam deposition (ICBD법으로 증착된 Al 박막의 증착특성 연구)

  • 안성덕;김동원;천성순;강상원
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.7 no.2
    • /
    • pp.207-215
    • /
    • 1997
  • Aluminum (Al) thin films were deposited on the Si(100) and TiN(60 nm)/Si (100) substrate by the ionized cluster beam deposition (ICBD) method. The characteristics of thin films were examined by the $\alpha$-step, four-point-probe, Scanning Electron Spectroscopy (SEM), Auger Electron Spectroscopy (AES). The growth rate of the Al thin film increased and the resistivity decreased as the crucible temperature increased. At the crucible temperature $1800^{\circ}C$, the microstructure of Al thin film deposited was smooth and continuous the resistivity decreased as the acceleration voltage increased. Also, the minimum resistivity in Si(100) substrate and TiN(60 nm)/Si(100) substrate were 3.4 $\mu \Omega \textrm {cm}$, 3.6 $\mu \Omega \textrm {cm}$ at the acceleration voltage 4 kV and 2 kV respectively. From the AES spectrumt 14 wasn't detected any impurities In the Al thin film. Therefore the resistivity of Al thin film was affected by the microstructure of film.

  • PDF

A Study of Kirkendall Void Formation and Impact Reliability at the Electroplated Cu/Sn-3.5Ag Solder Joint (전해도금 Cu와 Sn-3.5Ag 솔더 접합부의 Kirkendall void 형성과 충격 신뢰성에 관한 연구)

  • Kim, Jong-Yeon;Yu, Jin
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.15 no.1
    • /
    • pp.33-37
    • /
    • 2008
  • A noticeable amount of Kirkendall voids formed at the Sn-3.5Ag solder joint with electroplated Cu, and that became even more significant when an additive was added to Cu electroplating bath. With SPS, a large amount of voids formed at the $Cu/Cu_3Sn$ interface of the solder joint during thermal aging at $150^{\circ}C$. The in-situ AES analysis of fractured joints revealed S segregation on the void surface. Only Cu, Sn, and S peaks were detected at the fractured $Cu/Cu_3Sn$ interfaces, and the S peak decreased rapidly with AES depth profiling. The segregation of S at the $Cu/Cu_3Sn$ interface lowered interface energy and thereby reduced the free energy barrier for the Kirkendall void nucleation. The drop impact test revealed that the electrodeposited Cu film with SPS degraded drastically with aging time. Fracture occurred at the $Cu/Cu_3Sn$ interface where a lot of voids existed. Therefore, voids occupied at the $Cu/Cu_3Sn$ interface are shown to seriously degrade drop reliability of solder joints.

  • PDF

Determination of Chromium Content in Carbon Steel Pipe of NPP using ICP-AES

  • Choi, Kwang-Soon;Lee, Chang-Heon;Han, Sun-Ho;Park, Yong-Joon;Song, Kyu-Seok
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.12
    • /
    • pp.4270-4274
    • /
    • 2011
  • A method is proposed for determining chromium content in the carbon steel pipes of a nuclear power plant (NPP) to evaluate wall thinning caused by flow-accelerated corrosion (FAC). A flat file was used to obtain filings samples. To assess sampling quality, a disk form of SRM 1227 was ground with the flat file, and the amount of Cr in the filings was determined by ICP-AES. The content of chromium in the filings of SRM 1227 was estimated as six times higher than the certified value due to the contamination of chromium in the file. To eliminate chromium contamination from the file, it was coated with WC-12Co using high-velocity oxygen-fuel (HVOF) spraying systems. After obtaining filings samples using the coated file, Cr content in four types of disk-form SRMs was determined by ICP-AES. The recoveries of Cr in the disk-form SRMs were in the range of 95.4-102.6%, with relative standard deviations from 0.43 to 3.0%. The Cr contents in the filings collected from the used outlet headers of the nuclear power plants using the flat file coated were in the range of 0.11-0.19%.

A Systematic Review on Drug Safety for Molsidomine, Nicorandil and Trimetazidine (Molsidomine, Nicorandil, Trimetazidine의 안전성 관련 체계적 고찰)

  • Jeong, Kyeong Hye;Lee, Euni
    • Korean Journal of Clinical Pharmacy
    • /
    • v.26 no.2
    • /
    • pp.172-180
    • /
    • 2016
  • Background: Ischemic heart disease is the most common type of heart disease and an important cause of death in Korea. Among marketed anti-anginal medications, molsidomine, nicorandil, and trimetazidine are approved in Korea with unique mechanism of actions. As these drugs are not approved by the US Food and Drug Administration, the access to the up-to-dated and comprehensive safety-related information has been less than optimal from drug information resources used by Korean pharmacists. Methods: A systematic review was conducted using Embase and Korean manuscripts to compile safety updates for these medications. Out of 418 articles from keyword searches, 52 studies were reviewed in full to compare adverse effects (AEs) with the approved package inserts (PI). Results: Molsidomine related adverse effects were mostly mild or moderate, but anxiety, palpitation, epigastric pain, and sexual potency reduction were additional AEs found from the review not listed in PI. Although PI has included ulceration in oral cavity and gastrointestinal tracts including anus by nicorandil, the Korea FDA recently recommended adding corneal, genital, and skin ulcers to the approved PI. Trimetazidine induced Parkinsonism, worsening of the symptoms for patients diagnosed with Parkinson's disease, gastrointestinal burning, and muscle cramps were additionally identified AEs not listed in PI for trimetazidine. Conclusion: Continuous evaluations of the safety profile of these agents are needed to balance the risks and benefits to provide evidence-based safety counseling to the patients. In addition, more focused efforts on spontaneous reporting are warranted by healthcare professionals to safeguard patients against AEs.

Simultaneuous Determination of As(III) and As(V) in Disused Mine Tailing Samples by Hydride Generation-Inductively Coupled Plasma-Atomic Emission Spectrometry (수소화물 발생-유도결합 플라스마 원자 방출 분광법을 이용한 폐광산 광미 시료 중의 As(III)와 As(V)의 동시 정량)

  • Kim, Sun-Tae;Lim, Yoo-Ree;Park, Kyung-Su;Chung, Jin-Ho
    • Analytical Science and Technology
    • /
    • v.13 no.2
    • /
    • pp.189-193
    • /
    • 2000
  • Arsenic (III) and arsenic (V) in disused mine tailing samples have been determined simutaneuously by hydride generation inductively coupled plasma atomic emission spectrometry (HG-ICP-AES). Total arsenic was determined using 2% $NaBH_4$ and 6 M HCl after prereduction of As(V) to As(III) with) 1M KI. Arsenic (III) was determined selectively using citrate/citric acid buffer with range of pH 5-6, it was determined by HG-ICP-AES. Arsenic (V) can be evaluated by the differences. According to the results, arsenic (V) was over 90% among the total arsenic extracted from disused mine tailing samples.

  • PDF

Analytical Performance Evaluation of Pneumatic Nebulizers and Comparison of Their Characteristics (가압분무기의 성능 평가와 특성 비교)

  • Park, Chang Joon;Han, Myung Sub;Song, Sun Jin;Lee, Dong Soo
    • Analytical Science and Technology
    • /
    • v.15 no.2
    • /
    • pp.120-126
    • /
    • 2002
  • The analytical performance of four commercially-available pneumatic nebulizers(Meinhard, Cross-flow, Babington, ESI PFA) was evaluated using inductively coupled plasma-atomic emission spectrometry (ICP-AES) and ICP-mass spectrometry (ICP-MS) instruments. The performance of an inert concentric nebulizer and a modified conespray nebulizer, made in Korea Research Institute of Standards and Science (KRISS), is compared with that of the four commercial nebulizers. Variation of sample introduction efficiency was investigated as carrier argon pressure and sample uptake rate were changed. Variation of sensitivity, signal stability, blank intensity and oxide/hydride ratios were also studied when the nebulizers were connected to the ICP-MS and ICP-AES instruments. It was found that good analytical result such as high sensitivity, low blank, stable signal and so on can be obtained with judicious selection of the nebulizer depending on the type of sample, sample amount, type of analytical instrument and analyte.