• Title/Summary/Keyword: aerated biofilter

Search Result 12, Processing Time 0.028 seconds

간접포기식 침지여상에 의한 제지페수처리 (Papermill Wastewater Treatment by Indirect aerated Sebmerged Biofilter)

  • 원찬희
    • 한국환경과학회지
    • /
    • 제2권2호
    • /
    • pp.135-144
    • /
    • 1993
  • The purpose of this experimental research was focused to improve the quality of the effluent and the yielded sludge when the papermill wastewater was treated by the indirect aerated submerged biofilter as a second treatment method of papermill wastewater. Changing the various experimental factors (Nutrient additions or not, HRT, Fh ratio, recirculation ratio, etc) with indirect aerated submerged biofilter, the results are as follows. 1) because of the microbes concentration could be sustained to 9, oho man in submerged biofilter and then the volumetric organic loads could be increased to 2.7 kg-BOD/$m^3$<\TEX>/day, the reactor volume can be reduced. 2) Because of the yield coefficient(Y) and the endogenous decay coefficient(kd) were revealed 0.4 and 0.07/d, the yielded sludge volume was reduced. 3) The concentration of the sloughed sludge in the reactor was 2.62~4.01 %, so the thickener could be omited in the papermill wastewater sludge treatment process. 4) When the operating was conducted at HRT of 4hrs, the treatment efficiencies of BOD and COD were obtained 80% and 70%. 5) The range of the theoretical recirculation ratios of this reactor was 14~26. According to those ratios, at the low loads ( BOD volumetric loads is less than 0.79 kg-BOD/$m^3$<\TEX>/day, FM ratio is less than 2.0/d) the results were fitted to the theoretical recirculation ratios (14 ~26) and at the high loads the efficiency were increased to the rise of recirculation ratios.

  • PDF

호기성 침지여상에 의한 제지폐수처리 (Papermill Wastewater Treatment by Indirect Aerated Submerged Biofilter)

  • 원찬희;권영호
    • 상하수도학회지
    • /
    • 제8권1호
    • /
    • pp.44-52
    • /
    • 1994
  • The purpose of this experimental research was focused to improve the quality of the effluent and the yielded sludge when the papermill wastewater was treated by the indirect aerated submerged biofilter as a second treatment method of papermill wastewater. Changing the various experimental factors(Nutrient additions or not, HRT, F/M ratio, recirculation ratio, etc) with indirect aerated biofilter, the results obtained are as follows. 1. Because of the microbes concentration could be sustained to $9,000mg/l$ in submerged biofilter and then the volumetric organic loads could be increased to $2.7kg-BOD/m^3/day$(that of activated sludge is $0.8kg-BOD/m^3/day$), the reactor volume can be reduced to one third of the activated sludge treatment. 2. Because of the yield coefficient(Y) and the endogenous decay coefficient(kd) were revealed 0.4 and 0.07/d, the yielded sludge volume was reduced by for compared with that of the activated sludgg process. 3. The concentration of the sloughed sludge in the reactor was 2.62~4.01%, so the thickener could be omitted in the papermill wastewater sludge treatment process. 4. When the operating was conducted at HRT of 4hrs, the treatment efficiencies of BOD and COD were obtained 80% and 70%, Therefore operating time can be reduced to one half of the activated sludge treatment.

  • PDF

Removal of Organic Load from Olive Washing Water by an Aerated Submerged Biofilter and Profiling of the Bacterial Community Involved in the Process

  • Pozo, Clementina;Rodelas, Belen;Martinez-Toledo, M. Victoria;Vilchez, Ramiro;Gonzalez-Lopez, Jesus
    • Journal of Microbiology and Biotechnology
    • /
    • 제17권5호
    • /
    • pp.784-791
    • /
    • 2007
  • The present work aims to use a biofilter technology(aerated submerged filters) for the aerobic transformation at laboratory-scale of olive washing water(OWW) generated in the first steps of olive oil processing, as well as the genetic profiling and identification to the species level of the bacteria involved in the formation of the biofilm, by means of TGGE. Chemical parameters, such as biological oxygen demand at five days($BOD_5$) and chemical oxygen demand(COD), decreased markedly(up to 90 and 85%, respectively) by the biological treatment, and the efficiency of the process was significantly affected by aeration and inlet flow rates. The total polyphenol content of inlet OWW was only moderately reduced(around 50% decrease of the inlet content) after the biofilter treatment, under the conditions tested. Partial 16S rRNA genes were amplified using total DNA extracted from the biofilm and separated by TGGE. Sequences of isolated bands were mostly affiliated to the $\alpha-subclass$ of Proteobacteria, and often branched in the periphery of bacteria] genera commonly present in soil(Rhizobium, Reichenowia, Agrobacterium, and Sphingomonas). The data obtained by the experimentation at laboratory scale provided results that support the suitability of the submerged filter technology for the treatment of olive washing waters with the purpose of its reutilization.

간접폭기형 침적생물여과장치(INSUB)를 이용한 오수처리 특성 (Characteristics of sewage Treatment by using Indirectly Aerated Submerged Biofilter(INSUB))

  • 허목;강진영;김광진
    • 유기물자원화
    • /
    • 제11권2호
    • /
    • pp.125-131
    • /
    • 2003
  • 본 연구는 오수중의 유기물 및 질소 인의 동시제거를 위한 오 폐수 고도처리장치인 간접폭기형 침적생물막여과장치(Indirected Aerated Submerged Biofilter : INSUB)를 개발하기 위하여 실험실적 모형실험을 수행하였다. INSUB에서 오수를 처리함에 있어서, HRT 18시간, 공탑속도 42.5m/hr, 충전율 40%인 경우가 실제로 경제적인 효율을 고려하였을 때, 가장 효율이 좋았다. 각각의 제거효율을 살펴보면, $COD_{cr}$, 90.6%, $COD_{Mn}$ 85.3%, $BOD_5$ 95.0%, T-N 52.3% 그리고 T-P 56.8%로 나타났다. 질소 인의 고효율처리를 위해서는 전탈질공정에 의한 산화질소의 제거를 위해 무산소, 호기조의 조합 등에 의한 system의 일부 다단화가 필요함을 확인할 수 있었다.

  • PDF

호기 생물막법에 의한 저농도 기질제거법에 관한 고찰 (A Study on Low Concentration Substrate Removal by Using the Aerated Submerged Biofilter)

  • 홍성철;정문식
    • 한국환경보건학회지
    • /
    • 제15권2호
    • /
    • pp.59-68
    • /
    • 1989
  • This study was performed employing the two stage aerated submerged biofilter of media pore size 1.5cm and 2cm, and infiuent substrate concentrations were 30.25mg COD/l, 50.1mg COD/l respectively. The purpose was to determine the treatment efficiency at the low concentration infiuent, reaction order and substrate flux with application of variable-order model that was presented by Rittmann and McCarty. . The results are as follows. 1. Treatment efficiency of 1st reactor was about BOD 82% and COD 76%, when effluent concentration was BOD 3.9 ~ 6.8, COD 7.1 ~ 12.5 mg/l, and this effluent concentration didn't satisfy the water quality grade I, II of river and lake. But as treated effluent of 1st reactor with 2nd reactor, we could achieve appropriate water quality, since instillation of 2nd reactor was needed. 2. Difference of media pore size between 1.5cm and 2cm didn't effect significantly to treatment efficiency and since this of 2nd reactor was about BOD 60%, COD 50%, an consideration of economic point of view should be carried out in field application. 3. Reaction order and substrate flux was varied 0.9851~0.9956 and 0.0028~0.0405 mg/$cm^{2} \cdot day$, and the substrate flux was increased as infiuent substrate concentration increased.

  • PDF

부상여재반응기에서 ASM3를 이용한 질산화 공정 모사 (Modelling of Nitrogen Oxidation in Aerated Biofilter Process with ASM3)

  • 전병희
    • 한국지반환경공학회 논문집
    • /
    • 제8권4호
    • /
    • pp.19-25
    • /
    • 2007
  • 하폐수의 생물학적 고도처리 공정의 설계와 운전 최적화에 필요한 자료를 제공하기 위하여 ASM3를 이용하여 부상여재반응기(ABF)에 대한 해석을 수행하였다. 대상 반응기로서는 수중의 부유물질 제거와 질산화 반응을 위해 이용되는 호기적 부상여재반응기로 하였다. 본 연구에서는 하폐수 고도처리공정 중 활성슬러지의 생흡착반응을 이용한 전체 시스템 중에 흡착조를 거친 유출수를 부상여재를 이용하여 질산화시키는 공정에 대한 해석을 목적으로 하였다. 민감도 분석과 영향평가를 위해서 상용 수처리 공정해석 프로그램인 GPS-X(V 5.0)을 이용하였다. 민감도 분석을 통해 공정거동에 영향이 큰 매개변수($Y_A$, $k_{sto}$, ${\mu}_A$, $K_{A,HN}$)가 결정되었고, 70일간의 pilot plant 운전자료를 이용한 동적 시뮬레이션을 통해 최적화하였다. 최적화된 매개변수 값들은 $Y_A$가 0.14, $k_{sto}$는 3.5/d, ${\mu}_A$는 2.7/d, $K_{A,HN}$는 1.1mg/L로 결정되었다. 최적화된 매개변수 값들을 이용하여 시뮬레이션을 수행하였고, 부상여재반응기의 수리학적 체류시간(HRT)을 10분에서 4시간으로 변화시키면서 TN, $NH_4{^+}-N$, $NO_3{^-}-N$의 변화를 예측하여 실측값과 비교한 결과 HRT가 10분 정도로 매우 짧은 운전조건에서도 60%에 가까운 질산화율을 보여주고 있었다. 짧은 HRT에서 우수한 질산화 능력을 보인 부상여재의 특성을 이용하여 유량변동이 매우 큰 현장에 부상여재반응기가 효과적으로 적용될 수 있다고 판단되었다.

  • PDF

잔자갈을 충전(充塡)한 간접폭기방식(間接曝氣方式) 침지여상(浸漬濾床)에 의한 합성하수처리(合成下水處理) (Treatment of Synthetic Wastewater by Indirect Aerating Biofilter Submerged Gravel)

  • 양상현;원찬희
    • 대한토목학회논문집
    • /
    • 제8권3호
    • /
    • pp.129-138
    • /
    • 1988
  • 본(本) 연구(硏究)에서는 잔자갈을 충전(充塡)한 간접폭기방식(間接曝氣方式) 침지여상(浸漬濾床)의 설계(設計)나 운전에 합리성(合理性)을 부여하기 위해, 폭기조(曝氣槽)에서 침지여상(浸漬濾床)으로의 산소공급(酸素供給) 특성(特性) 및 잔자갈의 입경(粒徑), 순환수(循環水)의 수량부하(水量負荷), $BOD_5$ 용적부하(容積負荷) 변화에 대한 처리효율(處理效率)을 검토하였다. 실험(實驗)은 $20^{\circ}C$를 유지한 침지여상(浸漬濾床)의 하부(下部)에 합성하수(合成下水)를 상향류(上向流)로 연속주입(注入)하였고, 동시(同時)에 포기조에서 충분히 포기된 물을 침지여상(浸漬濾床)에 상향류(上向流)로 순환(循環)시키면서 수행되었다. 실험결과(實驗結果) 가장 적당한 잔자갈의 입경(粒徑)은 11 mm 정도였으며, 설계(設計) 및 운전을 위해서는 잔자갈의 표면적부하(表面的負荷)보다는 침지여상(浸漬濾床)의 용적(容積)을 기준으로 하는 것이 타당하며, 90% 이상의 $BOD_5$ 제거율을 얻기 위해서는 BOD 용적부하율(容積負荷率)을 $1.0kg-BOD_5/m^3{\cdot}d$ 이하로 운전하여야 하며, 이때 순환수(循環水)($DO7.2mg/{\ell}$)의 수량부하(水量負荷)는 $189m^3/m^3{\cdot}d$ 이상으로 유지시켜야 할 것으로 나타났다. 또 본실험(本實驗) 범위내에서 반응속도계수(反應速度係數) $K_1$은 순환수(循環水)의 수량(水量) 부하(負荷) 및 잔자갈의 입경(粒徑)과 밀접한 관계(關係)가 있음을 알았다.

  • PDF

혐기-호기 상향류 필터 공정에서 양식배출수의 질산화 및 탈질 연구 (Nitrification and Denitrification of Land-based Fish Farm Wastewater using an Anaerobic-Aerobic Upflow Biological Aerated Filter)

  • 박노백;이현영;김성민;이준상
    • 한국수산과학회지
    • /
    • 제47권5호
    • /
    • pp.622-629
    • /
    • 2014
  • This study induced biological denitrification and nitrification via a biofiltration process with the view of removing nitrogen from land-based fish farm effluent. To achieve this, we operated an aquaculture nitrogen-removal system that includes a denitrification and nitrification reactor [working volume 40 L, flow rate 64.8 L, HRT (hydraulic retention time) 14.8 h, HRT considering recycling of NOx 7.4 h]. In the continuous process, the nitrification rate of ammonium nitrogen exceeded 90% at a steady state and the denitrification efficiency exceeded 80% with recycling to a pre-anoxic reactor. In addition, the pH in the final effluent was lower with a low influent water alkalinity averaging 100 mg/L (as $CaCO_3$). For effective denitrification reactions, carbon must be supplied via particulate organic matter (POM) hydrolysis because of the low C/N (carbon/nitrogen) ratio in the water.

BAF 공정을 이용한 제직폐수의 재이용 (Reuse of Weaving Wastewater with BAF Process)

  • 정용준;배종홍;권구호;민경석
    • 한국물환경학회지
    • /
    • 제20권6호
    • /
    • pp.664-669
    • /
    • 2004
  • An upflow BAF(Biological Aerated Filter) equipped with an expanded clay media was applied to reuse weaving wastewater of water jet loom. The performance of lab-scale biofilter was investigated by the adjustment of EBCTs(Empty Bed Contact Time) and the packing ratio of media, which were changed 1.1 to 3.7hr and 38 to 63%, respectively. In most conditions except 1.1hr of EBCT, BOD, CODcr, SS and Turbidity of the effluent were 1~4mg/L, 7~16mg/L, 1~5mg/L and 5~14NTU, where their removal efficiencies were 76~95%, 82~93%, 63~94% and 59~81%, respectively. From the observation of SEM(Scanning Electron Microscope) photographs of porous clay media, it was revealed that this media provided good performance of retaining microbes effectively. In addition, $0.44~0.49kgVSS/kgBOD_{rem}$. of low sludge reduction was expected. The most efficient back washing cycle and procedure were once per 4 to 9 days and air including collapse-pulsing method, respectively. Therefore, this system can be of use as an weaving wastewater treatment for reuse.

낮은 C/N비에서 운영되는 유로변경식 생물여과 공정의 질소 제거 특성 (Nitrogen Removal Characteristics in DynaFlow Biofilter System Using Sewage Wastewater of Low C/N Ratio)

  • 김진식;김규리;강한솔;원인섭;김금용;이상일
    • 대한환경공학회지
    • /
    • 제34권3호
    • /
    • pp.189-194
    • /
    • 2012
  • 본 연구는 유로변경식 3단 BAF를 사용하여, C/N ($TCOD_{cr}$/TKN)비가 낮은 생활하수를 대상으로 질소 처리 효율을 향상시키기 위해 제안되었다. 체류시간 6시간에서의 유로변경 3단 BAF의 효과를 평가하기 위해 실험실 규모로 실시하였다. 유로변경식 3단 BAF 공정이 3단 BAF보다 총 질소 제거효율이 약 7% 높은 것으로 나타났는데, 이것은 유기물을 효율적으로 사용하였기 때문이다. 또한 암모니아성 질소의 제거는 독립적인 호기조에서 질산화만을 수행하였기 때문에 질산화 효율이 안정적이었다. 이것은 본 연구에서 제안한 유로변경식 3단 BAF공정이 유기물 흡착을 이용하여 질소의 제거, 탈질 및 질산화에서 우수한 효율을 보였다.