• Title/Summary/Keyword: adsorption rate constant

Search Result 146, Processing Time 0.029 seconds

Biosorption and Desorption of Heavy Metals using Undaria sp. (미역 폐기물의 중금속 흡탈착 특성)

  • Cho, Ju-Sik;Park, Il-Nam;Heo, Jong-Soo;Lee, Young-Seak
    • Korean Journal of Environmental Agriculture
    • /
    • v.23 no.2
    • /
    • pp.92-98
    • /
    • 2004
  • The adsorption and desorption of Pb, Cd, Co, Zn, Cr, Co, Ni, and Mo on the waste Undaria sp. were studied. Except for Pb. the mono adsorption rate for all heavy metals were lower than that of the heavy metals mixed. However, the adsorption capacity of the heavy metals by 1g of biosorption, in mixed heavy metals increased According to FT-IR analysis of the biosorbent after heavy metal biosorption, the replacement of the functional group by the heavy metals ions could be confirmed and the inverted peaks became larger after heavy metals adsorption. The adsorption equilibrium of heavy metals was reached in about 1 hour. The equilibrium parameters were determined based on Langmuir and Freundlich isotherms. The affinity of metals on the biosorbent decreased in the following order: Pb>Cu>Cr>Cd>Co. The desorption rate decreased in the following sequence: NTA>$H_2SO_4$>HCl>EDTA. The desorption rate of heavy metals by NTA increased with increase in the concentration from 0.1 to 0.3% but the desorption rate became constant beyond 0.3%. Therefore, it represented that desorption rate of heavy metals was suitable under optimized condition ($30^{\circ}C$, pH 2 and 0.3% NTA solution) and was fast with 80% or more the uptake occurring within 10 min of contact time.

Flocculation Characteristics of Kaoline Suspensions in Water by Cationic Polyelectrolytes

  • Kam, Sang-Kyu;Kim, Dae-kyoung;Ko, Byung-Churl;Moon, Chang-Seong;Lee, Min-Gyu
    • Journal of Environmental Science International
    • /
    • v.11 no.2
    • /
    • pp.93-102
    • /
    • 2002
  • Using a simple continuous optical technique, coupled with measurements of zeta potential, the flocculation characteristics of kaoline suspensions of different content(15, 35 and 55 NTU) by several cationic polyelectrolytes, has been examined. The optimum mixing is obtained under a constant stirring of 200 rpm, differently from a general flocculation test. The charge density of a polyelectrolyte is important in determining the optimum dosage and in the removal of kaoline particles. The optimum dosage is less for the polyelectrolyte of higher charge density and is the same regardless of kaoline content. At the dosage, the removal of kaoline particles is higher for the polyelectrolyte of higher charge density and zeta potential of kaoline particles reaches to near zero. The rate of adsorption and flocculation rate have been found to be affected by charge density and molecular weight of a polyelelctrolyte and the content of kaoline particles.

A Study on Hydrogen Impurity Effect in Anode of Proton Exchange Membrane Fuel Cell on Various Concentration of CO and H2S (고분자전해질 연료전지 연료극의 일산화탄소 및 황화수소 농도에 따른 불순물영향에 관한 연구)

  • LEE, EUN-KYUNG;BAEK, JAE-HOON;LEE, JUNG-WOON;LEE, SEUNG-KUK;LEE, YEON-JAE
    • Journal of Hydrogen and New Energy
    • /
    • v.27 no.6
    • /
    • pp.670-676
    • /
    • 2016
  • Hydrogen town in Republic of Korea was established in 2013. Hydrogen as a byproduct produced by various processes of factories is used in hydrogen town facilities. As cell performance is affected by contaminations in fuel gas, various standards about impurities of fuel have been determined by many countries. This study shows performance degradation of single cell with impurities concentrations. Traces of carbon monoxide (CO) and hydrogen sulfide ($H_2S$)can cause considerable cell performance losses. For comparing the performances by poisoning of CO, acceleration test, I-V curve, constant current are performed. Both the CO and $H_2S$ poisoning rate are a function of their concentration. With the higher concentrations the higher poisoning rates are observed. And, it was confirmed that, oxidation behavior and side reaction generation are not affected. Under the lower $H_2S$ concentration condition, the poisoning rate is much higher than that of CO because of its different adsorption intensity. It can be possible that the result of this study can be used for enacting regulation as a baseline data.

Analysis of an Immobilized β-Galactosidase Reactor with Competitive Product Inhibition Kinetics (경쟁적 저해를 갖는 고정화 β-galactosidase 반응기의 해석)

  • Kang, Byung Chul
    • Journal of Life Science
    • /
    • v.23 no.12
    • /
    • pp.1471-1476
    • /
    • 2013
  • The present study deals with the immobilization of Kluyveromyces lactis ${\beta}$-galactosidase on a weak ionic exchange resin (Duolite A568) as polymer support. ${\beta}$-Galactosidase was immobilized using the adsorption method. A kinetic study of the immobilized enzyme was performed in a packed-bed reactor. The adsorption of the enzyme followed a typical Freundlich adsorption isotherm. The adsorption parameters of k and n were 14.6 and 1.74, respectively. The initial rates method was used to characterize the kinetic parameters of the free and immobilized enzymes. The Michaelis-Menten constant ($K_m$) for the immobilized enzyme (120 mM) was higher than it was for the free enzyme (79 mM). The effect of competitive inhibition kinetics was studied by changing the concentration of galactose in a recycling packed-bed reactor. The kinetic model with competitive inhibition by galactose was best fitted to the experimental results with $V_m$, $K_m$, and $K_I$ values of 46.3 $mmolmin^{-1}mg^{-1}$, 120 mM, and 24.4 mM, respectively. In a continuous packed-bed reactor, increasing the flow rate of the lactose solution decreased the conversion efficiency of lactose at different input lactose concentrations. Continuous operation of 11 days was conducted to investigate the stability of a long-term operation. The retained activity of the immobilized enzymes was 63% and the half-life of the immobilized enzyme was found to be 15 days.

A Mathematical Model for Prediction of the Fats of Polycyclic Aromatic Hydrocarbons in Activated Sludge Processes : Steady State and Dynamic Simulation (활성슬러지 하수처리장에 유입된 Polycyclic Aromatic Hydrocarbons의 농도분포를 예측하기 위한 수학적 모형의 개발)

  • Ko, Kwang Baik;Berthouex, Paul Mac
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.10 no.4
    • /
    • pp.173-184
    • /
    • 1990
  • A mathematical model was proposed to predict the predominant reactions and transport pathways of anthracene in a conventional activated sludge wastewater treatment system. The model consists of five differential equations with seven kinetic parameters and eighteen input variables. Volatilization, biodegradation, adsorption/desorption as well as the convective inputs and outputs are included in the model. The steady state calculations showed that volatilization (61%) in aeration tank and the withdrawal of primary sludge (33%) were two major pathways for removal of anthracene from the system. The overall removal was about 97%. The system reached a practical steady state at about 160 hours via dynamic modeling. The proposed model can give plausible predictions of the fate of priority organic pollutants in activated sludge processes.

  • PDF

Kinetics of In-situ Degradation of Nerve Agent Simulants and Sarin on Carbon with and without Impregnants

  • Saxena, Amit;Sharma, Abha;Singh, Beer;Suryanarayana, Malladi Venkata Satya;Mahato, Timir Haran;Sharma, Mamta;Semwal, Rajendra Prasad;Gupta, Arvind Kumar;Sekhar, Krishnamurthy
    • Carbon letters
    • /
    • v.6 no.3
    • /
    • pp.158-165
    • /
    • 2005
  • Room temperature kinetics of degradation of nerve agent simulants and sarin, an actual nerve agent at the surface of different carbon based adsorbent materials such as active carbon grade 80 CTC, modified whetlerite containing 2.0 and 4.0 % NaOH, active carbon with 4.0 % NaOH, active carbon with 10.0 % Cu (II) ethylenediamine and active carbon with 10.0 % Cu (II) 1,1,1,5,5,5-hexafluoroacetylacetonate were studied. The used adsorbent materials were characterized for surface area and micropore volume by $N_2$ BET. For degradation studies solution of simulants of nerve agent such as dimethyl methylphosphonate (DMMP), diethyl chlorophosphate (DEClP), diethyl cyanophosphate (DECnP) and nerve agent, i.e., sarin in chloroform were prepared and used for the uniform adsorption on the adsorbent systems using their incipient volume at room temperature. Degradation kinetics was monitored by GC/FID and was found to be following pseudo first order reaction. Kinetics parameters such as rate constant and half life were calculated. Half life of degradation with modified whetlerite (MWh/NaOH) system having 4.0 % NaOH was found to be 1.5, 7.9, 1206 and 20 minutes for DECnP, DEClP, DMMP and sarin respectively. MWh/NaOH system showed maximum degradation of simulants of nerve agents and sarin to their hydrolysis products. The reaction products were characterized using NMR technique. MWh/NaOH adsorbent was also found to be active against sulphur mustard.

  • PDF

BIOFILTRATION OF GASEOUS TOLUENE USING ADSORBENT CONTAINING POLYURETHANE FOAM MEDIA

  • Amarsanaa, Altangerel;Shin, Won-Sik;Choi, Jeong-Hak;Choi, Sang-June
    • Environmental Engineering Research
    • /
    • v.11 no.1
    • /
    • pp.1-13
    • /
    • 2006
  • In this study, conventional biofilters packed with flexible synthetic polyurethane (PU) foam carriers were operated to remove toluene from a contaminated air stream. PU foams containing various adsorbents (e.g., zeolite, sepiolite, dolomite and barite) were synthesized for the biofilter media and their adsorption characteristics of toluene were determined. Adsorption capacity of PU-adsorbent foam was in the order of PU-dolomite ${\approx}$ PU-zeolite > PU-sepiolite > PU-barite. During the biofiltration experiment, influent toluene concentration was in the range of 0-160 ppm and EBRT (i.e., empty bed residence time) was 45 seconds. Pressure drop of the biofilter bed was 4-5 mm $H_2O/m$ column height. The maximum removal capacity was in the order of PU-dolomite > PU-zeolite > PU-sepiolite > PU-barite, while the complete removal capacity was in the order of PU-dolomite > PU-sepiolite > PU-zeolite > PU-barite. The better biofiltration performance in PU-dolomite foam was because PU-dolomite foam had lower density and higher porosity than the others providing favorable conditions for microbial growth. The results of biodegradation kinetic analysis showed that PU-dolomite foam had higher maximum removal rate ($V_m\;=\;11.04\;g$ toluene/kg dry material/day) and saturation constant ($K_s\;=\;26.57\;ppm$) than the other PU foams. This supports that PU-dolomite foam was better than the others for biofilteration of toluene.

Effect of GAC Packing Mass in Hybrid Water Treatment Process of PVdF Nanofibers Spiral Wound Microfiltration and Granular Activated Carbon (PVdF 나노섬유 나권형 정밀여과와 입상 활성탄의 혼성 수처리에서 활성탄 충진량의 영향)

  • Kyung, Kyu Myung;Park, Jin Yong
    • Membrane Journal
    • /
    • v.27 no.1
    • /
    • pp.68-76
    • /
    • 2017
  • Flat membrane with $0.4{\mu}m$ pore size was prepared with PVdF (polyvinylidene fluoride) nanofiber, which has the advantages such as excellent strength, chemical resistance, non-toxicity, and incombustibility. The spiral wound module was manufactured with the flat membrane and a woven paper. Hybrid water treatment process was composed of the PVdF nanofibers spiral wound microfiltration and granular activated carbon (GAC) adsorption column. Effect of GAC packing mass was investigated by comparing the case of recycling or discharging the treated water using the synthetic solution of kaolin and humic acid. After each filtration experiment, water back-washing was performed, and recovery rate and filtration resistances were calculated. Also, effect of GAC adsorption was compared by measuring turbidity and $UV_{254}$ absorbance. As a result, there was no effect of GAC packing mass on turbidity treatment rate; however, the treatment rate of $UV_{254}$ absorbance was 0.7~3.6% for recycling the treated water, and increased to 3.2-5.7% for discharging the treated water. In the case of recycling the treated water, reversible filtration resistance ($R_r$) and irreversible filtration resistance ($R_{ir}$) trended to decrease as increasing GAC packing mass; however, total fitration resistance ($R_t$) was almost constant, and recovery rate of water back-washing trended to increase a little.

Hydrolysis of Cellulose by Immobilized Cellulase in a Packed Bed Reactor (충진층 반응기에서 고정화 cellulase에 의한 셀룰로스 가수 분해)

  • Kang, Byung Chul;Lee, Jong Baek
    • Journal of Life Science
    • /
    • v.23 no.11
    • /
    • pp.1365-1370
    • /
    • 2013
  • Immobilized cellulase on weak ion exchange resin showed a typical Langmuir adsorption isotherm. Immobilized cellulase had better stability with respect to pH and temperature than free cellulase. Kinetics of thermal inactivation on free and immobilized cellulase followed first order rate, and immobilized cellulase had a longer half-life than free cellulase. The initial rate method was used to characterize the kinetic parameters of free and immobilized enzyme. The Michaelis-Menten constant $K_m$ was higher for the immobilized enzyme than it was for the free enzyme. The effect of the recirculation rate on cellulose degradation was studied in a recycling packed-bed reactor. In a continuous packed-bed reactor, the increasing flow rate of cellulose decreased the conversion efficiency of cellulose at different input lactose concentrations. Continuous operation for five days was conducted to investigate the stability of long term operation. The retained activity of the immobilized enzymes was 48% after seven days of operation.

The Effect of Fumed Silica on Nitrate Reduction by Zero-valent Iron (흄드 실리카가 영가철에 의한 질산성질소 환원에 미치는 영향)

  • Cho, Dong-Wan;Jeon, Byong-Hun;Kim, Yong-Je;Song, Ho-Cheol
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.6
    • /
    • pp.599-608
    • /
    • 2010
  • The effect of silica(fumed) on nitrate reduction by zero-valent iron(ZVI) was studied using batch experiment. The reduction of nitrate was tested in three different aqueous media including de-ionized water, artificial groundwater and real groundwater contaminated by nitrate. Kinetics of nitrate reduction in groundwater were faster than those in de-ionized water, and first-order rate constant($k_{obs}$) of ZVI/silica(fumed) process was about 2.5 time greater than that of ZVI process in groundwater. Amendment of Silica(fumed) also decreased ammonium presumably through adsorption on silica surface. The pHs in all processes increased due to oxidation of ZVI, but the increase was lower in groundwater due to buffering capacity of groundwater. The result also showed amount of reduced nitrate increased as initial nitrate concentration increased in groundwater. Separate adsorption isotherm experiments indicated that fumed silica itself had some degree of adsorption capacity for ammonium. The overall results indicated that silica(fumed) might be a promising material for enhancing nitrate reduction by ZVI.