• Title/Summary/Keyword: adjusting coefficient

Search Result 144, Processing Time 0.02 seconds

The effects of chromium exposure on sister chromatid exchange and concentration of 8-hydroxydeoxyguanosine (크롬 폭로가 자매염색분체교환 빈도 및 8-hydroxydeoxyguanosine 농도에 미치는 영향)

  • Han, Sang-Hwan;Cho, Soo-Hun;Kim, Heon;Ha, Mi-Na;Joo, Young-Soo;Park, Soo-Min;Kwon, Ho-Jang;Kim, Yong-Dae;Chung, Myung-Hee
    • Journal of Preventive Medicine and Public Health
    • /
    • v.28 no.2 s.50
    • /
    • pp.511-525
    • /
    • 1995
  • To elucidate some DNA adducts as a biological marker for workers of chromate pigment, the effects of chromium exposure on the formation of 8-hydroxydeoxyguanosine(8-OH-dG) and sister chromatid exchanges(SCEs) frequency in 38 workers of a pigment plant in Bucheon which utilized lead chromates, were examined. The chromium contents of venous blood and urine were measured as working environmental exposure level. The concentrations of 8-OH-dG in DNA isolated from lymphocytes were determined with high performance liquid chromatography and electrochemical detector and denoted as a molar ratio of 8-OH-dG to deoxyguanosine(dG). The SCEs frequency were analyzed in DNA isolated from lymphocytes. A significant correlation was found between creatinine adjusted urine chromium concentration and the molar ratio of 8-OH-dG to dG(r=0.47, p<0.01). After adjusting the current smoking habit, the correlation coefficient was increased(r=0.62, p<0.05). However, there was no significant correlation between the SCE frequency and chromium exposure. This significant results between molar ratio of 8-OH-dG to dG and chromium exposure are in good agreement with in vitro studies that support the importance of DNA adduct formation for the carcinogenic effect of chromium.

  • PDF

Improved AR-FGS Coding Scheme for Scalable Video Coding (확장형 비디오 부호화(SVC)의 AR-FGS 기법에 대한 부호화 성능 개선 기법)

  • Seo, Kwang-Deok;Jung, Soon-Heung;Kim, Jin-Soo;Kim, Jae-Gon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.12C
    • /
    • pp.1173-1183
    • /
    • 2006
  • In this paper, we propose an efficient method for improving visual quality of AR-FGS (Adaptive Reference FGS) which is adopted as a key scheme for SVC (Scalable Video Coding) or H.264 scalable extension. The standard FGS (Fine Granularity Scalability) adopts AR-FGS that introduces temporal prediction into FGS layer by using a high quality reference signal which is constructed by the weighted average between the base layer reconstructed imageand enhancement reference to improve the coding efficiency in the FGS layer. However, when the enhancement stream is truncated at certain bitstream position in transmission, the rest of the data of the FGS layer will not be available at the FGS decoder. Thus the most noticeable problem of using the enhancement layer in prediction is the degraded visual quality caused by drifting because of the mismatch between the reference frame used by the FGS encoder and that by the decoder. To solve this problem, we exploit the principle of cyclical block coding that is used to encode quantized transform coefficients in a cyclical manner in the FGS layer. Encoding block coefficients in a cyclical manner places 'higher-value' bits earlier in the bitstream. The quantized transform coefficients included in the ealry coding cycle of cyclical block coding have higher probability to be correctly received and decoded than the others included in the later cycle of the cyclical block coding. Therefore, we can minimize visual quality degradation caused by bitstream truncation by adjusting weighting factor to control the contribution of the bitstream produced in each coding cycle of cyclical block coding when constructing the enhancement layer reference frame. It is shown by simulations that the improved AR-FGS scheme outperforms the standard AR-FGS by about 1 dB in maximum in the reconstructed visual quality.

Optimal Monetary Policy System for Both Macroeconomics and Financial Stability (거시경제와 금융안정을 종합 고려한 최적 통화정책체계 연구)

  • Joonyoung Hur;Hyoung Seok Oh
    • KDI Journal of Economic Policy
    • /
    • v.46 no.1
    • /
    • pp.91-129
    • /
    • 2024
  • The Bank of Korea, through a legal amendment in 2011 following the financial crisis, was entrusted with the additional responsibility of financial stability beyond its existing mandate of price stability. Since then, concerns have been raised about the prolonged increase in household debt compared to income conditions, which could constrain consumption and growth and increase the possibility of a crisis in the event of negative economic shocks. The current accumulation of financial imbalances suggests a critical period for the government and central bank to be more vigilant, ensuring it does not impede the stable flow of our financial and economic systems. This study examines the applicability of the Integrated Inflation Targeting (IIT) framework proposed by the Bank for International Settlements (BIS) for macro-financial stability in promoting long-term economic stability. Using VAR models, the study reveals a clear increase in risk appetite following interest rate cuts after the financial crisis, leading to a rise in household debt. Additionally, analyzing the central bank's conduct of monetary policy from 2000 to 2021 through DSGE models indicates that the Bank of Korea has operated with a form of IIT, considering both inflation and growth in its policy decisions, with some responsiveness to the increase in household debt. However, the estimation of a high interest rate smoothing coefficient suggests a cautious approach to interest rate adjustments. Furthermore, estimating the optimal interest rate rule to minimize the central bank's loss function reveals that a policy considering inflation, growth, and being mindful of household credit conditions is superior. It suggests that the policy of actively adjusting the benchmark interest rate in response to changes in economic conditions and being attentive to household credit situations when household debt is increasing rapidly compared to income conditions has been analyzed as a desirable policy approach. Based on these findings, we conclude that the integrated inflation targeting framework proposed by the BIS could be considered as an alternative policy system that supports the stable growth of the economy in the medium to long term.

The Usefulness of Pressure-regulated Volume Control(PRVC) Mode in Mechanically Ventilated Patients with Unstable Respiratory Mechanics (기계 호흡 중 불안정한 호흡역학을 보인 환자에서 압력조절용적조정양식(Pressure-regulated Volume Control Mode)의 효용)

  • Sohn, Jang-Won;Koh, Youn-Suck;Lim, Chae-Man;Shim, Tae-Sun;Lee, Jong-Deog;Lee, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.6
    • /
    • pp.1318-1325
    • /
    • 1997
  • Background : Since the late 1960s, mechanical ventilation has been accomplished primarily using volume controlled ventilation(VCV). While VCV allows a set tidal volume to be guaranteed, VCV could bring about excessive airway pressures that may be lead to barotrauma in the patients with acute lung injury. With the increment of knowledge related to ventilator-induced lung injury, pressure controlled ventilation(PCV) has been frequently applied to these patients. But, PCV has a disadvantage of variable tidal volume delivery as pulmonary impedance changes. Since the concept of combining the positive attributes of VCV and PCV(dual control ventilation, DCV) was described firstly in 1992, a few DCV modes were introduced. Pressure-regulated volume control(PRVC) mode, a kind of DCV, is pressure-limited, time-cycled ventilation that uses tidal volume as a feedback control for continuously adjusting the pressure limit However, no clinical studies were published on the efficacy of PRVC until now. 'This investigation studied the efficacy of PRVC in the patients with unstable respiratory mechanics. Methods : The subjects were 8 mechanically ventilated patients(M : F=6 : 2, $56{\pm}26$ years) who showed unstable respiratory mechanics, which was defined by the coefficients of variation of peak inspiratory pressure for 15 minutes greater than 10% under VCV, or the coefficients of variation of tidal volume greater than 10% under PCV. The study was consisited of 3 modes application with VCV, PCV and PRVC for 15 minutes by random order. To obtain same tidal volume, inspiratory pressure setting was adjusted in PCV. Respiratory parameters were measured by pulmonary monitor(CP-100 pulmonary monitor, Bicore, Irvine, CA, USA). Results : 1) Mean tidal volumes($V_T$) in each mode were not different(VCV, $431{\pm}102ml$ ; PCV, $417{\pm}99ml$ ; PRVC, $414{\pm}97ml$) 2) The coefficient of variation(CV) of $V_T$ were $5.2{\pm}3.9%$ in VCV, $15.2{\pm}7.5%$ in PCV and $19.3{\pm}10.0%$ in PRVC. The CV of $V_T$ in PCV and PRVC were significantly greater than that in VCV(p<0.01). 3) Mean peak inspiratory pressure(PIP) in VCV($31.0{\pm}6.9cm$ $H_2O$) was higher than PIP in PCV($26.0{\pm}6.5cm$ $H_2O$) or PRVC($27.0{\pm}6.4cm$ $H_2O$)(p<0.05). 4) The CV of PIP were $13.9{\pm}3.7%$ in VCV, $4.9{\pm}2.6%$ in PVC and $12.2{\pm}7.0%$ in PRVC. The CV of PIP in VCV and PRVC were greater than that in PCV(p<0.01). Conclusions : Because of wide fluctuations of VT and PIP, PRVC mode did not seem to have advantages compared to VCV or PCV in the patients with unstable respiratory mechanics.

  • PDF