• 제목/요약/키워드: adjustable stock tray

검색결과 4건 처리시간 0.014초

치과용 스캐닝 시스템의 개발과 가변형 상악용 트레이의 재현성 (Development of Dental Scanning System and Reproduction of Adjustable Upper Dental Impression Tray)

  • 차영엽;엄상호
    • 제어로봇시스템학회논문지
    • /
    • 제16권3호
    • /
    • pp.300-304
    • /
    • 2010
  • This study was performed to development a dental three-dimensional laser scanning system and measure the accuracy of new adjustable upper dental impression tray. The metal stock, individual, and new adjustable stock trays were used for 30 stone casts(10 casts each) duplicated a resin master model of maxilla. The dental stone was poured in a vinyl polysiloxane impressions and allowed to set for on hour. The master model and the duplicated casts were digitized using an dental scanning system. The distance between the reference points were measured and analyzed on the graphic image of 3D graphic software of CATIA. The statistical significance of the differences between the groups was determined by a two-way ANOVA. There were no significant differences between the accuracies of the adjustable stock tray and the master model except only anterior arch width on the upper arch. The adjustable upper stock tray showed clinically acceptable accuracies of the study cast produced by them.

가변형 치과 인상용 트레이로 제작된 모형의 재현성 (Accuracy of Stone Cast Produced by Adjustable Dental Impression Tray)

  • 박광수;동진근;심헌보;오상천
    • 구강회복응용과학지
    • /
    • 제22권4호
    • /
    • pp.317-328
    • /
    • 2006
  • Purpose: This study was performed to measure the accuracy of adjustable dental impression trays by a scanning laser three-dimensional digitizer. Materials and Methods: Metal stock tray and adjustable stock trays were used for 40 stone casts(10 casts each) duplicated a resin master model of mandible and maxilla. The type IV dental stone was poured in a allginate impressions and allowed to set for one hour. The casts were digitized using an optical digitizer. The distance between the reference points were measured and analyzed on the graphic image of 3-D graphic software (CATIA version 5.0). The statistical significance of the differences between the groups was determined by a two-way ANOVA. Results: There were no significant differences between the accuracies of the adjustable stock tray and the master model except anterior arch width of the upper arch and the diagonal arch length and arch length(one side) of the lower arch. Conclusion: The adjustable stock trays showed clinically acceptable accuracies of the study casts produced by them.

가변형 치과 인상용 트레이로 제작된 모형의 재현성에 관한 연구 (ACCURACY OF STONE CAST PRODUCED BY ADJUSTABLE DENTAL IMPRESSION TRAY)

  • 엄상호;오상천
    • 대한치과보철학회지
    • /
    • 제43권4호
    • /
    • pp.453-465
    • /
    • 2005
  • Purpose: This study was performed to measure the accuracy of adjustable dental impression trays by a scanning laser three-dimensional digitizer. Materials and methods: The metal stock, individual, and adjustable stock trays were used for 60 stone casts(10 casts each) duplicated a resin master model of mandible and maxilla. The type IV dental stone was poured in a vinyl polysiloxane impressions and allowed to set for one hour. The master model and the duplicated casts were digitized using an optical digitizer. The distance between the reference points were measured and analyzed on the graphic image of 3-D graphic software(CATIA version 5.0). The statistical significance of the differences between the groups was determined by a two-way ANOVA. Results : There were no significant differences between the accuracies of the adjustable stock tray and the master model except only anterior arch width on the upper arch and the diagonal arch length and arch length on one side of the lower arch. Conclusion: The adjustable stock trays showed clinically acceptable accuracies of the study cast produced by them.

스캐닝 시스템과 하악용 가변형 트레이의 재현성 (Scanning System and Reproduction of Adjustable Lower Dental Impression Tray)

  • 차영엽;엄상호
    • 제어로봇시스템학회논문지
    • /
    • 제17권3호
    • /
    • pp.254-257
    • /
    • 2011
  • This study was performed to development a dental three-dimensional laser scanning system and measure the accuracy of new adjustable lower dental impression trays. Multiple impressions of a resin master model were made with custom, stock and new adjustable trays and vinyl polysiloxane impression material. The lower master model and resulting cast were compared using an dental scanning system. Each 3D image was superimposed onto the lower master model image and analyzed with custom software. Multiple measurements of the lower master model and casts were analyzed to determine the accuracy of tray types.