• Title/Summary/Keyword: adjustable power

Search Result 181, Processing Time 0.023 seconds

Proportional Gas Flow Control Valve Using Piezo Actuator (압전액추에이터를 이용한 비례 가스유량제어밸브)

  • Yun S.N.;Kim C.Y.;Ham Y.B.;Lee K.W.;Kang J.H.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.2 no.3
    • /
    • pp.6-11
    • /
    • 2005
  • A household gas valve is used for flow control of LPG(Liquefied Petroleum Gas) or LNG(Liquefied Natural Gas) of which pressure is about $200mmH_2O(\fallingdotseq\;0.0196[bar])$. Currently, two kinds of valves such as rotary type and button type are widely used in many applications. But, these valves have some problems that they are not controllable and reliable. Piezo actuation combined with modem microelectronics provides a reliable, quiet, low energy, infinitely adjustable gas valve. In this paper, gas valve using piezo actuator which are bimorph and a circle type was studied. Also, Prototype for gas valve was manufactured and characteristics of the prototype gas valve were analyzed.

  • PDF

Cost-effective Design of an Inverter Output Reactor in ASD application (전동기 과전압 억제용 OUTPUT REACTOR의 최적 설계)

  • 김한종;이근호;장철호;이제필
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.65-70
    • /
    • 1999
  • In this paper, the cost-effective design of output reactor which is used to suppress the over-voltage at the motor terminal in the Adjustable Speed Drives(ASD) application is proposed. In the elevator drive system, the power cable length is relatively shorter than other ASD applications and then the over-voltage at the motor terminal depends on the frequency characteristics of the output reactor at the over-voltage operating frequency. The over-voltage suppression mechanism of output reactor in ASD application is analyzed and the dominant parameters of output reactor for the over-voltage suppression are extracted. Using these parameters as the design values and considering the high frequency characteristics of iron core in the reactor, a new cost-effective structure of output reactor is proposed. Experimental results of the conventional reactor and the proposed reactor with a 15kW induction motor are given to verify the proposed scheme.

  • PDF

Fault Diagnosis of a Electrolytic Capacitor for Inverter DC-Link Voltage Smoothing (인버터 직류링크 전압 평활용 전해 커패시터의 고장 진단)

  • Lee, Kwang-Woon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.12 no.5
    • /
    • pp.372-377
    • /
    • 2007
  • This paper proposes a novel fault diagnosis method of a electrolytic capacitor used for DC-link voltage smoothing in adjustable speed drives. The equivalent series resistance (ESR) of the electrolytic capacitor is directly estimated from DC-link voltage and load currents and the status of the electrolytic capacitor is determined from the estimated ESR. To compensate the variation of the ESR owing to temperature variation, diodes are located on the same PCB near the capacitor and the temperature of the capacitor is sensed indirectly from the voltage drop of diodes. Simulation and experimental studies show the effectiveness of the proposed method.

A Measurement of Switching Surge Voltage Using Inverter devices (인버터의 스위칭 서지전압 측정)

  • Kim, Jong-Gyeum;Jeong, Jong-Ho;Lee, Eun-Woong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.53 no.1
    • /
    • pp.14-21
    • /
    • 2004
  • Most adjustable-speed drives (ASDs) designed to operate low voltage induction motors incorporate voltage-source inverters (VSIs), which create motor voltages at high switching frequencies. The motor leads used to connect an ASD to a motor can behave like transmission lines for voltage pulses, which can be reflected at the motor terminals. The resulting oscillatory transient, known as the long-lead effect, can stress and consequently degrade the stator insulation system of a motor. This paper describes the results of tests to 1) determine the correlation between peak motor voltage and the length of motor leads and 2) determine the correlation between peak motor voltage and the switching frequency of the ASD Insulation failures like this usually are caused by voltage surges. Voltage surges are often the result of switching power circuits, lightning strikes, capacitor discharges and solid-state power devices.

Design of SRM for Low Noise Drive of EV (소음저감을 위한 EV용 SRM 구동 시스템의 설계)

  • Song H.S.;Park S.J.;Ahn J.W.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.840-843
    • /
    • 2003
  • The switched reluctance motor(SRM) drive system provides a good adjustable speed and torque characteristics. SRM has the possibility of maintaining full power over a wide speed range. So, many attempts are being done from home appliances to industrial machinery and tools. Especially, a traction drive of an SRM is one of a good application for it's DC-series characteristic. However, because of the switching mechanism, it has some disadvantage of noise and vibration. It is difficult to adopt to an appliance demanding silency. A noise simulation and design of 6/4 and 12/8 SRM was done in order to compare each other was done.

  • PDF

SR Drive System for LSEV (LSEV용 SR Drive System)

  • Song Hyun-Soo;Ahn Jin-Woo;An Young-Ju;Park Sung-Jun
    • Proceedings of the KIPE Conference
    • /
    • 2003.11a
    • /
    • pp.109-112
    • /
    • 2003
  • SRM(switched reluctance motor) provides a excellent adjustable speed and torque characteristics. SRM has the possibility of maintaining full power over a wide speed range. So, many attempts are being done from home appliances to industrial applications. Especially, a traction drive of an SRM is one of a good application for it's DC-series characteristic. However, because of the switching mechanism and reluctance torque, it has some disadvantage Of noise and Vibration. It is difficult to adopt to an appliance demanding silency. A performance and noise tests with 6/4 and 12/8 SRM were done to compare the characteristics.

  • PDF

Analysis and Measurement of Current Harmonics Due to Non-linear Load in Low Voltage System (저압 시스템에서 비선형 부하의 사용에 따른 전류 고조파 해석 및 측정)

  • Kim, Jong-Gyeom;Lee, Eun-Ung
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.12
    • /
    • pp.601-608
    • /
    • 2001
  • The ever increasing density of adjustable speed drives(ASD) device with non-linear operating characteristics has been to put tremendous harmonic stress on end user's electrical application. All ASD controllers which employ solid state power devices cause harmonic currents in the source side line. This paper describes harmonic problems for use of ASD. In order to investigate the effect of harmonics caused by using of nonlinear load at the low voltage system, we fixed up simple load model and measured the voltage and current waveforms. Measurement results show that additional operation of linear load at the parallel bus with nonlinear load such as ASD is helpful to the reduction of harmonic influence.

  • PDF

Performance Analysis for the Modified Excitation System of Synchronous Machine Connected to HVDC System

  • Kim, Chan-Ki
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.2B no.3
    • /
    • pp.109-114
    • /
    • 2002
  • This paper analysis the transient performance of the modified excitation system using 4-quadrant chopper for a synchronous machine connected to HVDC system. Conventionally, capacitors are used to supply reactive power requirement at a strong converter bus. And the installation of a synchronous machine is essential in an isolated weak network to re-start after a shutdown of HVDC and to increase the system strength. However, a conventional static excitation system has some problems which are harmonic instability and the system stress due to overvoltage. To reduce these problems, the new excitation system, which has 4-quadrant chopper, is proposed. As the proposed system provides the capability to allow reverse current and isolate between AC network and excitation power, problems of overvoltage and harmonic instability can be solved. The investigation is performed and confirmed by the time domain digital simulation using PSCAD/EMTDC program.

A New Injection Method of Harmonic Compensation Current by Active AC Power Filter (능동형 교류 전력 필터에 의한 고조파 보상전류의 새로운 주입방식)

  • 박민호;최규하
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.34 no.9
    • /
    • pp.361-367
    • /
    • 1985
  • A new injection method is proposed for active power filters to eliminate AC harmonics in ac input current of nonlinear loads such as rectifiers. By injecting the PWM current determined by the proposed injection method, all the harmonics up to order nn can be eliminated to exactly zero. This PWM injection current can be generated by sampling total harmonic wave at the rate of M and the sampled values are converted into the proposed PWM wave with N pulse-width variables and adjustable current magnitude Im. These variables are deetermined by solving a set of N nonlinear harmonic equations and the harmonic-elimination characteristics of the new injection are investigated through digital computer sinmulation. Also by comparing between the simulated results and the ones synthesized by data stored in EPROM, the possibility of the suggested injection method can be shown.

  • PDF

Research on Development of a dynamic LED lighting system (동적 LED 조명 시스템의 개발에 대한 연구)

  • Choi, Jong-Dae;Kim, Hyo-In;Yun, Geun-Young
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.04a
    • /
    • pp.168-173
    • /
    • 2011
  • Recently, from a saving energy and environmental lighting sources point of view, using LED lighting have been increased rapidly. The colors of light was applied to the control of dimmers that is composed of red, green, blue, and white(RGBW) to improve the quality of visual environment. Moreover this study has been processed to develop adjustable dynamic LED lighting system on SPD and definitize the various spectral power distribution and color temperature of light through the control of the four dimmers. It is possible to combine up to $432^4$ kinds of light. Measurement of illuminance of range on working surface was as 7~l,831 lux. Application of visual environment for occupants can be expected according to control of lighting performance.

  • PDF