• 제목/요약/키워드: adhesive area

검색결과 232건 처리시간 0.023초

카복실레이트계 시멘트의 접착력에 관한 비교 연구 (COMPARATIVE STUDIES OF THE ADHESIVE QUALITIES OF POLYCARBOXYLATE CEMENTS)

  • 이한무
    • 대한치과보철학회지
    • /
    • 제17권1호
    • /
    • pp.23-34
    • /
    • 1979
  • In this study, the adhesive strength of three commercial polycarboxylate cements to ten types of dental casting alloys, such as gold, palladium, silver, indium, copper, nickel, chromium, and human enamel and dentine were measured and compared with that of a conventional zinc phosphate cement. The $8.0mm{\times}3.0mm$ cylindrical alloy specimens were made by casting. The enamel specimens were prepared from the labial surface of human upper incisor, and the dentine specimens were prepared from the occulusal surface of the human molar respectively. Sound extracted human teeth, which had been kept in a fresh condition since, extraction, were mounted in a wax box with a cold-curing acrylic resin to expose the flattened area. The mounted teeth were then placed in a Specimen Cutter (Technicut) and were cut down under a water spray, and then the flat area on the all specimens were ground by hand with 400 and 600 grit wet silicone carbide paper. Two such specimens were then cemented together face-to-face with freshly mixed cement, and moderate finger pressure was applied to squeeze the cement to a thin and uniform film. All cemented specimens were then kept in a thermostatic humidor cabinet regulated at $23{\pm}2^{\circ}C.$ and more than 95 per cent relative humidity and tested after 24 hours and 1 week. Link chain was attached to each alloy specimen to reduce the rigidity of the jig assembly, and then all the specimens were mounted in the grips of the Instron Universal Testing Machine, and a tensile load was delivered to the adhering surface at a cross head speed of 0.20 mm/min. The loads to which the specimens were subjected were recorded on a chart moving at 0.50 mm/min. The adhesive strength was determined by measuring the load when the specimen separated from the cement block and by dividing the load by the area. The test was performed in a room at $23{\pm}2^{\circ}C.$ and $50{\pm}10$ per cent relative humidity. A minimum of five specimens were tested each material and those which deviated more than 15 per cent from the mean were discarded and new specimens prepared. From the experiments, the following results were obtained. 1) It was found that the adhesive strength of the polycarboxylate cement to all alloys tested was considerably greater than that of the zinc phosphate cement. 2) The adhesive strength of the polycarboxylate cements was superior to the non precious alloys, such as the copper, indium, nickel and chromium alloys, but it was inferior to the precious gold, silver and palladium alloys. 3) Surface treatment of the alloy was found to be an important factor in achieving adhesion. It appears that a polycarboxylate cement will adhere better to a smooth surface than to a rough one. This contrasts with zinc phosphate cements, where a rough helps mechanical interlocking. 4) The adhesion of the polycarboxylate cement with enamel was found superior to its adhesion with dentine.

  • PDF

A STUDY ON THE ADHESION OF A SOFT LINER CONTAINING 4-META TO THE BASE METAL ALLOY AND ITS VISCOELASTIC PROPERTY

  • Park Hyun-Joo;Kim Chang-Whe;Kim Yung-Soo
    • 대한치과보철학회지
    • /
    • 제41권6호
    • /
    • pp.732-746
    • /
    • 2003
  • Statement of problem. Soft lining materials, also referred to as tissue conditioning materials, tissue heating materials, relining materials, soft liners or tissue conditioners, were first introduced to dentistry by a plastic manufacturer in 1959. Since the introduction of the materials to the dental field, their material properties have been continually improved through the effort of many researchers. Soft lining materials have become widely accepted, particularly by prosthodontists, because of their numerous clinical advantages and ease of manipulation. Unfortunately, few reports have been issued upon the topic of increasing the bond strength between the base metal alloy used in cast denture bases and PMMA soft liner modified with 4-META, nor upon the pattern of debonding and material change in wet environment like a intra oral situation. Purpose. The purposes of this study were comparing the bond strength between base metal alloy used for the cast denture bases and PMMA soft liner modified with 4-META, and describing the pattern of debonding and material property change in wet environment like the intraoral situation. Material and Methods. This study consisted of four experiments: 1. The in vitro measurement of shear bond strength of the adhesive soft liner. 2. The in vitro measurement of shear bond strength of the adhesive soft liner after 2 weeks of aging. 3. A comparison of debonding patterns. 4. An evaluation the Relation time of modified soft liner. The soft liner used in this study was commercially available as Coe-soft (GC America.IL.,USA), which is provided in forms of powder and liquid. This is a PMMA soft liner commonly used in dental clinics. The metal primer used in this study was 4-META containing primer packed in Meta fast denture base resin (Sun Medical Co., Osaka, Japan). The specimens were formed in a single lap joint desist which is useful for evaluating the apparent shear bond strength of adhesively bonded metal plate by tensile loading. Using the $20{\times}20mm$ transparent grid, percent area of adhesive soft liner remaining on the shear area was calculated to classify the debonding patterns. To evaluate the change of the initial flow of the modified adhesive soft liner, the gelation time was measured with an oscillating rheometer (Haake RS150W/ TC50, Haake Co., Germany). It was a stress control and parallel plate type with the diameter of 35mm. Conclusion. Within the conditions and limitations of this study, the following conclusions were drawn as follows. 1. There was significant increase of bond strength in the 5% 4-META, 10% 4-META containing groups and in the primer coated groups versus the control group(P<0.05). 2. After 2 weeks of aging, no significant increase in bond strength was found except for the group containing 10% 4-META (P<0.05). 3. The gelation times of the modified soft liner were 9.3 minutes for the 5% 4-META containing liner and 11.5 minutes for the 10% 4-META liner. 4. The debonding patterns of the 4-META containing group after 2 weeks of aging were similar to those of immediaely after preparation, but the debonding pattern of the primer group showed more adhesive failure after 2 weeks of aging.

치과용 접착제가 복합레진 인레이와 레진시멘트의 결합력에 미치는 영향 (INFLUENCE OF ADHESIVE APPLICATION ON SHEAR BOND STRENGTH OF THE RESIN CEMENT TO INDIRECT RESIN COMPOSITE)

  • 송미혜;박수정;조현구;황윤찬;오원만;황인남
    • Restorative Dentistry and Endodontics
    • /
    • 제33권5호
    • /
    • pp.419-427
    • /
    • 2008
  • 본 연구는 레진시멘트의 레진인레이에 대한 접착 시 접착제 혹은 primer의 사용이 결합력에 영향을 미치는지 평가하기 위해 시행하였다. 직경 5mm,높이 4.5mm의 원기둥 형태로 제작한 레진인레이 (Tescera, Bisco, USA)의 표면을 1000번, 1500번 그리고 2000번 사포로 주수 하에서 연마하여 평편한 면을 형성한 후 레진인레이의 표면에 sandblasting을 시행한 후 표면에 1분 동안 silane을 도포하였다. 2군으로 나누어 한 군은 대조군으로, 다른 한 군은 표면에 동일한 제조사의 접착제나 프라이머를 도포한 후 중합하였다. 레진인레이 상에 3mm 직경의 구멍이 형성된 아크릴판을 고정하고, 구멍에 레진 시멘트를 주입하여 경화시켰다. 레진 시멘트는 Panavia-F (Kurary), Varolink-II(Ivoclar-Vivadent), RelyX Unicem(3M ESPE), Duolink(Bisco)와 자가중합형인 Multilink (Ivoclar-Vivadent)를 사용하였다. 제작된 시편을 만능물성시험기에 위치시고 전단결합강도를 측정하였다. 측정 결과 접착제나 프라이머를 도포한 군은 대조군에 비해 전단결합강도가 증가하였다 (p<0.05). 하지만 Variolink-II와 Panavia-F는 전단결합강도의 차이를 보이지 않았다. 대조군에서는 각 레진 시멘트간에 전단결합강도의 유의한 차이를 보였으며 (p<0.01) Variolink-II가 가장 높은 결합강도를 보인 반면, 자가중합형인 Multilink가 가장 낮은 결합강도를 보였다. 하지만, 접착제나 프라이머를 도포한 군에서는 각 제품간에 전단결합강토의 차이를 보이지 않았다. 이상의 결과 이원중합형이나 자가중합형 레진시멘을 이용하여 레진인레이 부착 시 silane 처리 후 접착제나 프라이머의 도포가 결합 강도의 증가를 위해 필요하리라 사료된다.

수중 보관이 접착용 레진의 물리적 성질에 미치는 영향 (The Influence of Water Storage on Mechanical Properties of Adhesive Resin)

  • 김원찬;이광원;이정;유미경;김정희
    • 구강회복응용과학지
    • /
    • 제22권2호
    • /
    • pp.193-202
    • /
    • 2006
  • Objective To evaluate the influence of water storage on the mechanical properties of dental adhesives over 1 and 3 months. Materials and Methods Adhesive resin sheets were prepared by pouring either All-bond 2(AB), Clearfil SE Bond(SE) into a mold measuring $15{\times}15{\times}0.9mm$. After solvent in primer evaporation, the adhesives were light-cured and removed from the mold and divided in two pieces, trimmed to hourglass shape that were used to determine the micro-tensile strength(MTS). Another hourglass shaped metal mold measuring $2.0{\times}1.5mm$ in cross-section area was made to determine the Young's modulus(E). Adhesive specimens for Young's modulus(E) were prepared in the same method. Specimens were stored at $37^{\circ}C$ in distilled water and tested after 1 and 3 months. The data were analyzed by one-way ANOVA and Tukey's test. Results Water storage significantly decreased the micro-tensile strength(MTS) of AB and SE specimens after 1 and 3 months(P<0.05). The Young's modulus(E) were also decreased after water storage for 1 and 3 months, but statistically not significant in each group of AB and SE group respectively. Conclusions Long-term exposure of adhesive resin to water can cause reduction of mechanical properties. It may compromise resin/dentin bonds and affect longevity of restorations.

Impact of composite patch on the J-integral in adhesive layer for repaired aluminum plate

  • Kaci, D. Ait;Madani, K.;Mokhtari, M.;Feaugas, X.;Touzain, S.
    • Advances in aircraft and spacecraft science
    • /
    • 제4권6호
    • /
    • pp.679-699
    • /
    • 2017
  • The aim of this study is to perform a finite element analysis of the Von Mises stresses distribution in the adhesive layer and of the J-Integral for a damaged plate repaired by a composite patch. Firstly, we study the effect of the fiber orientation, especially the position of the layers that have orientation angle different of $0^{\circ}$ from the first layer which is in all cases of our study oriented at ($0^{\circ}$) on the J-Integral. Secondly, we evaluate the effects of the mechanical properties of the patch and the use of a hybrid patch on the reduction of stresses distribution and J-Integral. The results show clearly that the stacking sequence for the composite patch must be selected to absorb optimally the stresses from the damaged area and to position the various layers of the composite under the first layer whose fibers orientation will remain in all cases equal to $0^{\circ}$. The use of a hybrid composite reduces significantly the J-Integral and the stresses in both damaged plate and the adhesive layer.

PDMS와 고분자 전해질 표면을 이용한 간편한 세포 패터닝 방법 (Facile Cell Patterning Based on Selectively Patterned Polydimethylsiloxane (PDMS) and Polyelectrolyte Surface)

  • 정헌호;송환문;황예진;황택성;이창수
    • KSBB Journal
    • /
    • 제24권6호
    • /
    • pp.515-520
    • /
    • 2009
  • This study presented facile method of cell patterning using fabricated PDMS patterns on polyelectrolyte coated surface. This basic principle is the fabrication of functional surface presenting two orthogonal surfaces such as cell adhesive and repellent properties. Cell adhesive surface was firstly fabricated with simple coating of polyelectrolyte multilayer. And then, the desired patterns of PDMS for the prevention of nonspecific binding of cells were transferred onto the previously formed thin film of polyelectrolyte multilayer. Thus, we could prepare novel functional surface simultaneously containing PDMS and polyelectrolyte region. As expected, the PDMS regions showed effective prevention of nonspecific binding of cell and the other region, exposed polyelectrolyte area, provided cell adhesive environment. The height of formed PDMS structure was about 100 nm. Based on this method, cell patterning can be successfully obtained with various pattern shapes and sizes. Therefore, we expect that this simple method will be useful platform technology for the development of cell chip, cell based assay system, and biochip.

High-Performing Adhesive Bonding Fastening Technique For Automotive Body Structures

  • Symietz, Detlef;Lutz, Andreas
    • 접착 및 계면
    • /
    • 제7권4호
    • /
    • pp.60-64
    • /
    • 2006
  • In modern vehicle construction the search for means of weight reduction, improving durability, increasing comfort and raising body stiffness are issues of priority to the design engineer. The intelligent usage of many materials such as high strength steel, light-alloys and plastics enables a significant vehicle weight reduction to be achieved. The classical joining techniques used in the automobile industry need to be newly-evaluated since they often do not present workable solutions for such mixed-material connections, for example aluminium/steel. Calculation/simulation methods have made progress as a key factor for broader and more cost-effective implementation of structural bonding. This will lead to reduction of spotwelds and accelerate the car development. A special focus of the paper is the use of high strength steel grades. It will be shown that adhesive bonding is a key tool for yielding the potential of advanced high strength steel for low gauging without compromising the stiffness. The latest status of adhesive development has been described. Improvements with physical strength and glass temperature as well as of process relevant properties are shown. Also the situation regarding occupational hygiene is treated, showing that by further spotweld point reduction the emission around the working area can be even lowered against the current praxis. High performing lightweight design cannot longer do without high performing crash durable adhesives.

  • PDF

Aperture를 이용한 MLA의 효율 개선 (Efficiency Improvement of MLA (Micro Lens Array) using Aperture)

  • 서현우;남민우;오해관;안효찬;김태준;위창현;이기근;양상식;송요탁
    • 반도체디스플레이기술학회지
    • /
    • 제10권1호
    • /
    • pp.91-94
    • /
    • 2011
  • This paper presents light transmission efficiency by optical adhesive thickness between MLA and aperture layer and by aperture hole size. The gap between MLA and Aperture layer is adjusted by the shim. The more optical adhesive thickness increases, the better light transmission efficiency increases up to a point. After that, the light transmission efficiency decreases because stray lights cannot transmit through the aperture layer owing to cut-off by aperture layer. And as a result of light transmission efficiency with changing aperture hole size, the light transmission efficiency is proportional to area of aperture hole. The more specified process is made, the better data and sample will be got.

치경부 마모증 수복시 상아질 접착제가 변연누출에 미치는 영향 (THE EFFECT OF DENTIN BONDING AGENTS ON MARGINAL LEAKAGE FOLLOWING RESTORATION ON THE CERVICAL ABRASION)

  • 구본욱;손호현
    • Restorative Dentistry and Endodontics
    • /
    • 제12권2호
    • /
    • pp.55-63
    • /
    • 1987
  • The purpose of this study is to evaluate the effect of dentin bonding agents on marginal leakage. V-shaped cavities were prepared on the faciocervical area of 140 extracted human teeth. In Groups of twenty cavities, they were restored as follow: Group 1 with enamel bonding resin and Silux, Group 2 Scotchbond and Silux, Group 3 enamel bonding resin and Heliomolar, Group 4 Dentin Adhesit and Heliomolar, Group 5 enamel bonding resin and Durafill, Group 6 Dentin Adhesive and Durafill, Group 7 Chembond. All specimens were thermocycled alternatively at $4^{\circ}C$ and $60^{\circ}C$ of 2% methylene blue dye solution, and sectioned faciolingually with diamond disk under water spray. The sectioned specimens observed with stereo microscope. Following results were obtained: 1. The groups filled with Scotchbond-Silux or Dentin Adhesit-Heliomolar had appeared lesser marginal leakage compared with the groups with enamel bonding resin-Silux or enamel bonding resin-Helimolar. 2. The group filled with Dentin Adhesive-Durafill did not show the reduction of the marginal leakage compared with the group with enamel bonding resin-Durafill. 3. There was significant difference among the four dentin bonding agents. Scotchbond showed the greatest marginal sealing ability, and Dentin Adhesit was the next. The marginal sealing ability of Dentin Adhesive was the worst.

  • PDF

착생에 따른 담쟁이덩굴 흡착근 표피조직의 변화 (Epidermal Changes of the Adhesive Disks During Wall Attachment in Parthenocissus tricuspidata)

  • 김정하;김인선
    • Applied Microscopy
    • /
    • 제37권2호
    • /
    • pp.83-91
    • /
    • 2007
  • 식물체는 기관에 따라 조직 및 세포의 종류와 배열이 분화 초기단계에 이미 정해져 특징적인 형태를 갖게 되나 여러 요인에 의해 변형되기도 한다. 줄기에 덩굴손이 변형되어 부정근인 흡착근을 형성하는 담쟁이덩굴은 벽면 등의 피착면에 착생하는 식물로 이들의 흡착근은 특징적인 구조를 지닌다. 본 연구에서는 착생에 따른 담쟁이덩굴의 흡착근 표피조직의 분화양상을 전자현미경적으로 추적하여 연구하였다. 흡착근은 분화 초기에 경정단 분열조직으로부터 포에 둘러싸여 발달한다. 초기의 어린 흡착근은 곤봉형으로 상 하피 구별이 되지 않으나 활발히 생장하는 흡착근은 구형으로 상 하피가 뚜렷이 분화된다. 최외층의 표피는 장방형의 세포로 구성되며 이들 표피세포는 세포벽에 얇은 각피층을 지닌다. 착생 전 흡착근은 볼록한 평철형이 되고 표피세포내 액포에는 전자밀도가 매우 높은 물질이 다량 축적된다. 착생 직전 및 직후 흡착근의 상 하피조직은 빠르게 변형되어 액포에 축적된 물질이 분비되면서 피착면에 더욱 밀착되고 수분이 소실된 흡착근은 세포사멸의 과정을 거친다. 이 시기 하피조직에서의 변화는 상피조직에 비해 급격히 일어나며, 분비물질은 벽면에 강력히 흡착되어 착생의 기능을 수행하게 된다. 특히 착생을 전후로 급격한 하피조직의 변화가 일어나 흡착근 하피조직의 외곽면이 먼저 피착면에 접촉하고 전자밀도가 높은 물질이 분비되어 오목한 상태를 유지하던 중앙부위도 물질이 분비되면서 흡착근 전체가 부착되게 된다. 즉, 전자밀도가 높은 물질의 분비와 수분소실에 의한 흡착근의 피착면으로의 밀착 등이 담쟁이덩굴 흡착근의 착생에 매우 중요한 역할을 하는 것으로 추정된다. 매년 이와 같은 방법으로 흡착근은 분화 초기단계에서부터 노화에 이르기까지 여러 단계를 거치며 신속한 형태적, 구조적 변화를 수반하면서 강력한 착생기능을 수행하게 된다.토끼 면역항체를 선모충유충 조직항원에 반응시켰을 때 충체의 표피와 기저층 그리고 EIM 및 stichocyte의 ${\alpha}_0\;{\alpha}_1$ 과립에 황금입자가 표지되었다. 따라서 1일 동안 배설되는 분비배설항원은 선모충 유충의 표피와 stichocyte의 ${\alpha}_0\;{\alpha}_1$ 과립에서 유도되는 반면에 3일 동안 배설되는 분비배설항원은 표피와 stichocyte의 ${\alpha}_0$ 과립에서 유도되고, 선모충유충 감염후 1주, 4주에 실험쥐에서 형성되는 감염항체는 선모충의 표피와 기저층 그리고 EIM에서 분비되는 항원에 의하여 생성된다. 이상의 결과로 선모충의 분비배설항원과 감염항원은 선모충 유충의 표피와 EIM및 stichocyte의 ${\alpha}_0\;{\alpha}_1$ 과립에서 유도되며 이들은 45 kDa 단백을 포함하고 있는 것으로 생각된다.성하고 있는 세포들에는 세포질이 어두운 세포와 밝은 세포가 있었으며, 세포질내에는 전자밀도가 높은 분비과립이 관찰되었다. 전체적인 특징은 눈물샘분비세포 중 장액세포의 것과 비슷하였으나, 과립의 크기는 작았다. 분비관을 구성하는 세포들 사이에도 연접복합체가 매우 잘 발달되어 있었다. 샘포에서 사이관으로 이행되는 곳에서도 샘포세포와 사이관세포 사이에서도 연접복합체가 관찰되었다. 분비관세포의 분비과립 가운데는 중심부분에 전자밀도가 더 높은 중심을 가진 다른 모양의 과립이 관찰되기도 하였다. 의해 사망한 환자는 없었다. 결 론: 자궁경부암 환자에 항암화학요법과 동시에 외부 방사선조사와 고선량률의 강내조사를 시행한 결과 독성이 심하지 않고 국소제어율과 단기 생존율이 양호하여 안전하고 효율적인 치료방법으로 생각된다. 그러나 장기 생존율과