• Title/Summary/Keyword: additional pressure

Search Result 790, Processing Time 0.023 seconds

Wind Engineering Study on the Surface-Pressure Characteristic of a Triangular Prism Located Behind a Porous Fence (다공성 방풍펜스 후방에 놓인 삼각프리즘의 표면압력특성에 관한 풍공학적 연구)

  • Park, Cheol-U;Lee, Sang-Jun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.11
    • /
    • pp.1496-1508
    • /
    • 1997
  • The effects of porous wind fence on the pressure characteristics around a 2-dimensional prism model of triangular cross-section were investigated experimentally. The fence and prism model were embedded in a neutral atmospheric surface boundary layer over the city suburb. In this study, various fences of different porosity, back fence, inclination angle of prism and location of additional back prisms were tested to investigate their effects on the pressure and wall shear stress of the prism surface. The fence and prism had the same height of 40 mm and Reynolds number based on the model height was Re=3.9*10$^{4}$. The porous fence with porosity 40% was found to be the best wind fence for decreasing the mean and pressure fluctuations on the prism surface. By installing the fence of porosity 40%, the wall shear stress on the windward surface of prism was largely decreased up to 1/3 of that without the fence. This indicates that the porous fence is most effective to abate the wind erosion. Pressure fluctuations on the model surface were decreased more than half when a back fence was located behind the prism in addition to the front fence. With locating several back prisms and decreasing the inclination angle of triangular prism, the pressure fluctuations on the model surface were increased on the contrary.

Sandwich-structured High-sensitivity Resistive Pressure Sensor based on Silver Nanowire (샌드위치 구조를 갖는 은 나노와이어 기반 고감도 저항성 압력 센서)

  • Lee, Jinyoung;Kim, Gieun;Shin, Dongkyun;Park, Jongwoon
    • Journal of the Semiconductor & Display Technology
    • /
    • v.17 no.2
    • /
    • pp.1-5
    • /
    • 2018
  • Elastic resistive pressure sensor is fabricated by a direct spray coating of silver nanowires (AgNWs) on uncured polydimethylsiloxane (PDMS) and an additional coating of a conductive polymer, poly(3,4-ethylenedioxythiophene): poly (styrene sulfonate) (PEDOT:PSS). To improve the sensitive and stability, we have fabricated sandwich-structured AgNW/polymer sensor where two AgNW/polymer-coated PDMS films are laminated with the conducting surfaces contacted by pressure lamination. It shows a resistance decrease upon loading due to the formation of dense network of AgNWs. It is demonstrated that the sandwich-structured AgNW/polymer sensor exhibits very high sensitivity ($2.59kPa^{-1}$) and gauge factor (37.8) in the low pressure regime. It can also detect a subtle placement and removal of a weight as low as 3.4 mg, the corresponding pressure of which is about 5.4 Pa. It is shown that the protrusion of AgNWs from PDMS is suppressed substantially by the over-coated PEDOT:PSS layer, thereby reducing hysteresis and rendering the sensor more stable.

A study on the working mechanism of internal pressure of super-large cooling towers based on two-way coupling between wind and rain

  • Ke, Shitang;Yu, Wenlin;Ge, Yaojun
    • Structural Engineering and Mechanics
    • /
    • v.70 no.4
    • /
    • pp.479-497
    • /
    • 2019
  • In the current code design, the use of a uniform internal pressure coefficient of cooling towers as internal suction cannot reflect the 3D characteristics of flow field inside the tower body with different ventilation rate of shutters. Moreover, extreme weather such as heavy rain also has a direct impact on aerodynamic force on the internal surface and changes the turbulence effect of pulsating wind. In this study, the world's tallest cooling tower under construction, which stands 210m, is taken as the research object. The algorithm for two-way coupling between wind and rain is adopted. Simulation of wind field and raindrops is performed iteratively using continuous phase and discrete phase models, respectively, under the general principles of computational fluid dynamics (CFD). Firstly, the rule of influence of 9 combinations of wind speed and rainfall intensity on the volume of wind-driven rain, additional action force of raindrops and equivalent internal pressure coefficient of the tower body is analyzed. The combination of wind velocity and rainfall intensity that is most unfavorable to the cooling tower in terms of distribution of internal pressure coefficient is identified. On this basis, the wind/rain loads, distribution of aerodynamic force and working mechanism of internal pressures of the cooling tower under the most unfavorable working condition are compared between the four ventilation rates of shutters (0%, 15%, 30% and 100%). The results show that the amount of raindrops captured by the internal surface of the tower decreases as the wind velocity increases, and increases along with the rainfall intensity and ventilation rate of the shutters. The maximum value of rain-induced pressure coefficient is 0.013. The research findings lay the basis for determining the precise values of internal surface loads of cooling tower under extreme weather conditions.

Modeling for Thermoacoustic Instability and Beating Pressure Amplification in Hybrid Rocket Combustion (하이브리드 로켓의 열음향 불안정과 연소압력 맥놀이 발생 모델링)

  • Hyun, Wonjeong;Lee, Changjin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.50 no.11
    • /
    • pp.783-789
    • /
    • 2022
  • In a recent study, it was observed that the combustion gas entering the post chamber of a hybrid rocket contains vortices with very small size and high frequency characteristics. In addition, it was observed that small vortices collided with the nozzle wall to create a counter-flow, resulting in additional combustion with ignition delay. This study investigated the physical relationship between ignition delay induced by the counter-flow and the formation of beating pressure. To do this, a newly modified model was proposed by including ignition delay in the existing energy kicked oscillator model proposed by Culick. Numerical results show that the ignition delay is an important factor in determining the occurrence of the combustion pressure beats through the periodic formation of thermoacoustic coupling. In addition, when the ignition delay was reduced by increasing the post chamber length, the phase difference between the energy kick and the pressure generation was increased, the periodic pressure beats did not occur at all.

Aerodynamic analysis on the step types of a railway tunnel with non-uniform cross-section

  • Li, Wenhui;Liu, Tanghong;Huo, Xiaoshuai;Guo, Zijian;Xia, Yutao
    • Wind and Structures
    • /
    • v.35 no.4
    • /
    • pp.269-285
    • /
    • 2022
  • The pressure-mitigating effects of a high-speed train passing through a tunnel with a partially reduced cross-section are investigated via the numerical approach. A compressible, three-dimensional RNG k-ε turbulence model and a hybrid mesh strategy are adopted to reproduce that event, which is validated by the moving model test. Three step-like tunnel forms and two additional transitions at the tunnel junction are proposed and their aerodynamic performance is compared and scrutinized with a constant cross-sectional tunnel as the benchmark. The results show that the tunnel step is unrelated to the pressure mitigation effects since the case of a double-step tunnel has no advantage in comparison to a single-step tunnel, but the excavated volume is an essential matter. The pressure peaks are reduced at different levels along with the increase of the excavated earth volume and the peaks are either fitted with power or logarithmic function relationships. In addition, the Arc and Oblique-transitions have very limited gaps, and their pressure curves are identical to each other, whereas the Rec-transition leads to relatively lower pressure peaks in CPmax, CPmin, and ΔCP, with 5.2%, 4.0%, and 4.1% relieved compared with Oblique-transition. This study could provide guidance for the design of the novel railway tunnel.

The Impact of Double-Skin Façades on Indoor Airflow in Naturally Ventilated Tall Office Buildings

  • Yohan, Kim;Mahjoub M. Elnimeiri;Raymond J. Clark
    • International Journal of High-Rise Buildings
    • /
    • v.12 no.2
    • /
    • pp.129-136
    • /
    • 2023
  • Natural ventilation has proven to be an effective passive strategy in improving energy efficiency and providing healthy environments. However, such a strategy has not been commonly adopted to tall office buildings that traditionally rely on single-skin façades (SSFs), due to the high wind pressure that creates excessive air velocities and occupant discomfort at upper floors. Double-skin façades (DSFs) can provide an opportunity to facilitate natural ventilation in tall office buildings, as the fundamental components such as the additional skin and openings create a buffer to regulate the direct impact of wind pressure and the airflow around the buildings. This study investigates the impact of modified multi-story type DSFs on indoor airflow in a 60-story, 780-foot (238 m) naturally ventilated tall office building under isothermal conditions. Thus, the performance of wind effect related components was assessed based on the criteria (e.g., air velocity and airflow distribution), particularly with respect to opening size. Computational fluid dynamics (CFD) was utilized to simulate outdoor airflow around the tall office building, and indoor airflow at multiple heights in case of various DSF opening configurations. The simulation results indicate that the outer skin opening is the more influential parameter than the inner skin opening on the indoor airflow behavior. On the other hand, the variations of inner skin opening size help improve the indoor airflow with respect to the desired air velocity and airflow distribution. Despite some vortexes observed in the indoor spaces, cross ventilation can occur as positive pressure on the windward side and negative pressure on the other sides generate productive pressure differential. The results also demonstrate that DSFs with smaller openings suitably reduce not only the impact of wind pressure, but also the concentration of high air velocity near the windows on the windward side, compared to SSFs. Further insight on indoor airflow behaviors depending on DSF opening configurations leads to a better understanding of the DSF design strategies for effective natural ventilation in tall office buildings.

Phase-Resolved CARS Temperature Measurement in a Lean Premixed Gas Turbine Combustor (I) -Effect of Equivalence Ratio on Phase-Resolved Gas Temperature- (CARS를 이용한 희박 예혼합 가스터빈 연소기내 온도 측정 (I) -연료/공기 혼합정도가 위상별 온도에 미치는 영향-)

  • Lee Jong Ho;Jeon Chung Hwan;Park Chul Woong;Hahn Jae Won;Chang Young June
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.10
    • /
    • pp.1184-1192
    • /
    • 2004
  • Experimental investigations were carried out in an atmospheric pressure, optically accessible and laboratory-scale dump combustor operating on methane gas. The objective of this study was to obtain the phase-resolved gas temperatures at different phases of the oscillating pressure cycle during unstable combustion. CARS temperature measurements were made at several spatial locations under lean premixed conditions to get the information on temperature field within the combustor. Also the effect of incomplete fuel-air mixing on phase-resolved temperature fluctuation was investigated. Results including phase-resolved averaged temperature, normalized standard deviation and temperature probability distribution functions (PDFs) were provided in this paper. Temperature PDFs gave an insight on the flame behavior. And strong correlation between phase-resolved temperature profile and pressure cycle was observed. Results of the phase-resolved high temperature gave an additional information on the perturbation of equivalence ratio at flame as well as the effect of mixing quality on NOx emission characteristics.

Effects of Aroma inhalation on Blood Pressure, Pulse Rate, Sleep, Stress, and Anxiety in Patients with Essential Hypertension (아로마 흡입이 본태성고혈압 환자의 혈압, 맥박, 수면, 스트레스, 불안에 미치는 효과)

  • Choi, Eun-Mi;Lee, Kyung-Sook
    • Journal of Korean Biological Nursing Science
    • /
    • v.14 no.1
    • /
    • pp.41-48
    • /
    • 2012
  • Purpose: This experimental research explored the effects of aroma inhalation on blood pressure, pulse, sleep, stress, and anxiety in patients with essential hypertension who are taking antihypertensive medication. Methods: A pilot survey, pre-test and post-test were conducted. The data were collected from August to October, 2009. The participants were 44 patients randomly assigned to an experimental group (22 people) and a control group (22 people). The experimental group received individual instruction for aroma inhalation, which lasted for 3 minutes. They inhaled blended oils of Lavender, Majoram and Ylang Ylang (The mixed ratio was 4:3:3), three times a day, for two weeks. Data from 36 patients were used for the final analysis (20 from the experimental group, 16 from the control group). Data were analyzed using SPSS version 13.0. Results: Sleep disturbance decreased in the experimental group (t=-2.258, $p$=.030). Blood pressure, pulse, stress, and anxiety were not significantly different between the two groups ($p$ >.05). Additional analysis of the experimental group showed that physical stress and psychological stress were significantly lowered. Conclusion: Aroma inhalation is an effective paramedical intervention for patients with essential hypertension.

An Experimental Study on Active Regeneration Timing for the Minimization of Fuel Penalty in Active Regeneration DPF System Using Diesel Injection (경유분사를 이용한 강제재생방식 DPF 시스템 연비 손실 최소화를 위한 재생시점 고찰)

  • Rah, Seung-Woo;Choung, Youn-Kyoo;Oh, Kwang-Chul
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.17 no.5
    • /
    • pp.91-96
    • /
    • 2009
  • The number of vehicles applied diesel engine are rapidly rising for fuel economy. Accompanying this trend, application of an after-treatment system is strictly required as a result of reinforced emission regulation. The Diesel Particulate Filter (DPF) system is considered as the most efficient method to reduce particulate matter by car makers but also in retrofit market. In this paper we discussed the optimization of active regeneration timing by comparing the fuel consumption from back pressure caused by PM loading and from active regeneration. The effects of back pressure of DPFs during PM loading, active regeneration condition and engine emission(PM) on additional fuel consumption are experimentally investigated and the proper regeneration timings according to DPF systems and fuel loss for 160,000km are determined.

Countermeasure on High Vibration of Branch Pipe with Pressure Pulsation Transmitted from Main Steam Header (주증기 배관 헤더의 압력맥동에 대한 분기 배관의 고진동 대책)

  • Kim, Yeon-Whan;Bae, Yong-Chae;Lee, Young-Shin
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.8 s.101
    • /
    • pp.988-995
    • /
    • 2005
  • Vibration has been severly increased at the branch pipe of main steam header since the commercial operation of nuclear power plant. Intense broad band disturbance flow at the discontinuous region such as elbow, valve, and header generates the acoustical pulsation which is propagated through the piping system. The pulsation becomes the source of low frequency vibration at piping system. If it coincide with natural frequency of the pipe system, excessive vibration is made. High level vibration due to the pressure pulsation related to high dynamic stress, and ultimately, to failure probability affects fatally the reliability and confidence of plant piping system. This paper discusses vibration effect for the branch pipe system due to acoustical pulsations by broad band disturbance flow at the large main steam header in 700 MW nuclear power plant. The exciting sources and response of the piping system are investigated by using on-site measurements and analytical approaches. It is identified that excessive vibration is caused by acoustical pulsations of 1.3 Hz, 4.4 Hz and 6.6 Hz transmitted from main steam balance header, which are coincided with fundamental natural frequencies of the piping structure. The energy absorbing restraints with additional stiffness and damping factor were installed to reduce excessive vibration.