• Title/Summary/Keyword: addition tests

Search Result 3,852, Processing Time 0.029 seconds

CQI Activity for the reduction of inaquate testing sample (부적합 검체 감소를 위한 CQI 활동)

  • Cha, Sang-Yeol;Yun, Eun-Hui;Lee, In-Suk;Bae, Seong-Hun;Gang, Ju-Seok;Baek, Yeo-Hyeon
    • Journal of Korea Association of Health Promotion
    • /
    • v.4 no.1
    • /
    • pp.125-131
    • /
    • 2006
  • Background: Inadequate samples make laboratory tests delay cause errors, which will deteriorate the quality of the tests. Therefore, adequate samples are essential for reliable test result. To reduce the inadequate samples, they should to analyze problems and seek a way of improvement through CQI (Continuous Quality Improvement) activity. This will minimize errors during the test and produce a fast and accurate result. Eventrally, the qualily of entire test may be improved, and as a result, a good quality of medical care service may be provided. Methods: At first, inappropriate testing items were collected. Then, generating fctors and problems were investigated and analyzed in each case, In addition, the category with higher frequency wes primarily supervised. In consegalnce, a reduction of are dustion of improper testing sample was oxpected through continuous education and CQI activity. Conclusion : At the beginning of CQI activitv, the number of inadequate testing sample was of 8,591 total samples, which gives the frequency of 0.72%. As CQI activity was carried out the number of improper testing sample reduced to 58 out of 11,415 cases, which yields the frequency of 0,51%. One may notice the difference 0.2%. Among the inadequate sample(blood), there was a high frequency of hemolysis; thus, more of CQI activity is required for this specific matter. Because the occurrence of inadequate testing affects the clinical outcomes, it is extremely important that one manages each step of the procedure in collecting samples and mamtaines the quality of entire tests.

  • PDF

A Study on the Design Specification for Characteristics of Grout Materials - Focus on LW method and MSG method - (국내 그라우팅 재료별 특성에 따른 설계사양에 관한 연구 - LW 공법 및 MSG 공법을 중심으로 -)

  • Chun, Byung-Sik;Kim, Jin-Chun;Nam, Soon-Sung;Ha, Kwang-Hyun
    • Journal of the Korean GEO-environmental Society
    • /
    • v.3 no.4
    • /
    • pp.67-79
    • /
    • 2002
  • The purpose of this study is to present criteria of selection of optimum grout materials through analyzing the limitation of permeability of each materials(MSG-N, OPC), in various ground conditions by comparing presentation of strength and permeability of MSG method and LW method(or SGR method). To do that, physical and chemical characteristics of grout materials were analyzed and compressive tests of homogel, mixed coagulation materials and hardening materials in certain mixing ratio, and of milk paste. In addition, permeability tests for each ground soil, each injection pressure, and each materials in combined stratum were performed with massive chamber. The results of tests showed that ultra fine grout materials like grout of MSG is necessary to construct effective grouting in sand and silty sand ground. Also, it is expected to become chemical grouting guide data to layout construction engineers because presented proper injection pressure by kind of object ground in case using ultra-fine grout material.

  • PDF

Development of Electrical Resistivity Survey System for Geotechnical Centrifuge Modeling (원심모형실험을 위한 전기비저항 탐사 시스템 구축)

  • Cho, Hyung-Ik;Bang, Eun-Seok;Yi, Myeong-Jong;Choo, Yun-Wook;Kim, Dong-Soo
    • Journal of the Korean Geotechnical Society
    • /
    • v.30 no.10
    • /
    • pp.19-31
    • /
    • 2014
  • In order to investigate ground state change visually in physical model during centrifuge testing, electrical resistivity survey was adopted. Commercial resistivity survey equipment verified at various in-situ sites was utilized. The resistivity survey equipment installed in centrifuge facility was remotely controlled through intranet and electrical resistivity images obtained while centrifuge testing was being checked by real-time inversion. To verify the stable operation of the developed resistivity survey system, preliminary tests were conducted. Model ground was uniformly constructed using unsaturated soil and saline water was dropped on the ground surface to simulate contaminant flow situation. During the 10 g centrifuge tests, electrical resistivity was continuously detected and the testing results were compared with those of identically carried out 1 g centrifuge tests. In addition, the electrical resistivity was directly measured immediately after the centrifuge test by open cutting the model. Finally, reliability of electrical resistivity survey in the centrifuge test was verified by comparing those testing results.

A Study on the Collision Behavior of Fairy Cycle to Vehicle (어린이용 자전거의 차량 충돌거동에 관한 연구)

  • Kang, Dae-Min;Ahn, Seung-Mo
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.20 no.1
    • /
    • pp.106-111
    • /
    • 2012
  • Recently the usage of bicycle has increased steeply in Korea owing to traffic culture of well- being. In a car to bicycle accident investigation, the throw distance of bicycle is very important factor for reconstructing of the accident. The variables that influence on the throw distance of bicycle can be classified into the factors of vehicle and bicycle. Simulations and collision tests in actual car to bicycle accident were executed for obtaining throw distance of bicycle. The simulations were done by PC-$CRASH^{TM}$ and for actual crash tests sand bags were used for the behavior of bicyclist instead of dummy. Factors considered were vehicle velocity and the moving angles of bicycle, also the types of bicycle and vehicle were fairy cycle and automobile, respectively. From the results, the throw distances of a head-on tire collision of $0^{\circ}$ direction was longer than that of tire crash test of $45^{\circ}$ direction, and the throw distances of a head -on frame crash test of $90^{\circ}$ direction was longer than that of frame crash test of $45^{\circ}$ direction. In addition restitution coefficient between vehicle and bicycle was estimated as about 0.1 with based on actual crash tests. Finally the increaser vehicle velocity the longer the throw distances of bicycle, and the results of simulation were relatively good agreement to the experimental results.

Static and Dynamic Behavior of Disk Bearings under Railway Vehicle Loading (철도차량하중에 의한 디스크받침의 정·동적 거동특성)

  • Oh, Saeh Wan;Choi, Eun Soo;Jung, Hie Young;Kim, Hak Soo
    • Journal of Korean Society of Steel Construction
    • /
    • v.18 no.4
    • /
    • pp.469-480
    • /
    • 2006
  • The goal of this study is to ases the static and dynamic behavior of disk bearings under railway vehicle loadings. Several static tests were conducted in a laboratory t bearings, all having the same kind of polyurethane disk as used in the static tests, were installed under a full-sized railway bridge and tested with a running locomotive, the tests results, the static and dynamic stiffness of the disk bearings were estimated and compared. the deformation of the disk bearings under the bridge was measured at varying disk bearing was almost half of that under dynamic loading. In addition, the dynamic stiffness of the fixed disk bearing was 80% higher than that of an expansion disk bearing, since the PTFE in the expansion bearing is displaced. The deformation of the disk bearing did not vary significantly with changes in locomotive's speed. The results of this study can contribute to fast-tracking the formulation of a design technique for disk bearings for railway bridges.

Appropriateness Evaluation of Preoperative Hospitalization: A Case Study of A Tertiary Care Hospital (수술전 재원기간의 적절성 평가)

  • Kim, Soo Young;Lee, Key Hyo;Kwon, Young Dae
    • Quality Improvement in Health Care
    • /
    • v.4 no.2
    • /
    • pp.184-195
    • /
    • 1997
  • Background : The purpose of this research was to evaluate the appropriateness of preoperative hospital days in a tertiary care hospital and to examine the reasons of the inappropriateness, so as to provide basic information and policy for enhancing appropriateness of preoperative hospitalization and benefit of patients and hospital. Methods : The subjects of the research were the 344 patients who received operation among discharged patients during January, 1996 in surgical departments including general surgery, neurosurgery, orthopedic surgery, plastic surgery and ophthalmology. Their medical records were reviewed and appropriateness of hospital days was evaluated by the Appropriateness Evaluation Protocol. Result : The results of evaluating the appropriateness of preoperative hospitalization showed that inappropriate hospital days were 80.8%. The reasons of inappropriate hospital stays were the tests or preparation which could be done in outpatient basis' followed by 'possible tests or preparation on the operation day' and 'cancelation of operation'. Conclusion : In order to shorten the inappropriate preoperative length of stay, it is recommended that lengthening of laboratory running time and doing most of tests necessary for operations on the outpatient basis prior to admission should be considered. In addition, the operation at the same day of hospitalization and usage of day surgery should be encouraged. Finally there should be changes in the inpatient management system and attitudes and behaviors of surgeons to shorten unnecessary preoperative and maximize the benefit for patients and hospital.

  • PDF

Soil arching analysis in embankments on soft clays reinforced by stone columns

  • Fattah, Mohammed Y.;Zabar, Bushra S.;Hassan, Hanan A.
    • Structural Engineering and Mechanics
    • /
    • v.56 no.4
    • /
    • pp.507-534
    • /
    • 2015
  • The present work investigates the behavior of the embankment models resting on soft soil reinforced with ordinary and stone columns encased with geogrid. Model tests were performed with different spacing distances between stone columns and two lengths to diameter ratios (L/d) of the stone columns, in addition to different embankment heights. A total number of 42 model tests were carried out on a soil with undrianed shear strength $${\sim_\sim}10kPa$$. The models consist of stone columns embankment at s/d equal to 2.5, 3 and 4 with L/d ratio equal 5 and 8. Three embankment heights; 200 mm, 250 mm and 300 mm were tested for both tests of ordinary (OSC) and geogrid encased stone columns (ESC). Three earth pressure cells were used to measure directly the vertical effective stress on column at the top of the middle stone column under the center line of embankment and on the edge stone column for all models while the third cell was placed at the base of embankment between two columns to measure the vertical effective stress in soft soil directly. The performance of stone columns embankments relies upon the ability of the granular embankment material to arch over the 'gaps' between the stone columns spacing. The results showed that the ratio of the embankment height to the clear spacing between columns (h/s-d) is a key parameter. It is found that (h/s-d)<1.2 and 1.4 for OSC and ESC, respectively; (h is the embankment height, s is the spacing between columns and d is the diameter of stone columns), no effect of arching is pronounced, the settlement at the surface of the embankment is very large, and the stress acting on the subsoil is virtually unmodified from the nominal overburden stress. When $(h/s-d){\geq}2.2$ for OSC and ESC respectively, full arching will occur and minimum stress on subsoil between stone columns will act, so the range of critical embankment height will be 1.2 (h/sd) to 2.2 (h/s-d) for both OSC and ESC models.

Determining minimum analysis conditions of scale ratio change to evaluate modal damping ratio in long-span bridge

  • Oh, Seungtaek;Lee, Hoyeop;Yhim, Sung-Soon;Lee, Hak-Eun;Chun, Nakhyun
    • Smart Structures and Systems
    • /
    • v.22 no.1
    • /
    • pp.41-55
    • /
    • 2018
  • Damping ratio and frequency have influence on dynamic serviceability or instability such as vortex-induced vibration and displacement amplification due to earthquake and critical flutter velocity, and it is thus important to make determination of damping ratio and frequency accurate. As bridges are getting longer, small scale model test considering similitude law must be conducted to evaluate damping ratio and frequency. Analysis conditions modified by similitude law are applied to experimental test considering different scale ratios. Generally, Nyquist frequency condition based on natural frequency modified by similitude law has been used to determine sampling rate for different scale ratios, and total time length has been determined by users arbitrarily or by considering similitude law with respect to time for different scale ratios. However, Nyquist frequency condition is not suitable for multimode system with noisy signals. In addition, there is no specified criteria for determination of total time length. Those analysis conditions severely affect accuracy of damping ratio. The focus of this study is made on the determination of minimum analysis conditions for different scale ratios. Influence of signal to noise ratio is studied according to the level of noise level. Free initial value problem is proposed to resolve the condition that is difficult to know original initial value for free vibration. Ambient and free vibration tests were used to analyze the dynamic properties of a system using data collected from tests with a two degree-of-freedom section model and performed on full bridge 3D models of cable stayed bridges. The free decay is estimated with the stochastic subspace identification method that uses displacement data to measure damping ratios under noisy conditions, and the iterative least squares method that adopts low pass filtering and fourth order central differencing. Reasonable results were yielded in numerical and experimental tests.

Characterization of railway substructure using a hybrid cone penetrometer

  • Byun, Yong-Hoon;Hong, Won-Taek;Lee, Jong-Sub
    • Smart Structures and Systems
    • /
    • v.15 no.4
    • /
    • pp.1085-1101
    • /
    • 2015
  • Changes in substructure conditions, such as ballast fouling and subgrade settlement may cause the railway quality deterioration, including the differential geometry of the rails. The objective of this study is to develop and apply a hybrid cone penetrometer (HCP) to characterize the railway substructure. The HCP consists of an outer rod and an inner mini cone, which can dynamically and statically penetrate the ballast and the subgrade, respectively. An accelerometer and four strain gauges are installed at the head of the outer rod and four strain gauges are attached at the tip of the inner mini cone. In the ballast, the outer rod provides a dynamic cone penetration index (DCPI) and the corrected DCPI (CDCPI) with the energy transferred into the rod head. Then, the inner mini cone is pushed to estimate the strength of the subgrade from the cone tip resistance. Laboratory application tests are performed on the specimen, which is prepared with gravel and sandy soil. In addition, the HCP is applied in the field and compared with the standard dynamic cone penetration test. The results from the laboratory and the field tests show that the cone tip resistance is inversely proportional to the CDCPI. Furthermore, in the subgrade, the HCP produces a high-resolution profile of the cone tip resistance and a profile of the CDCPI in the ballast. This study suggests that the dynamic and static penetration tests using the HCP may be useful for characterizing the railway substructure.

Static behaviour of lying multi-stud connectors in cable-pylon anchorage zone

  • Lin, Zhaofei;Liu, Yuqing;He, Jun
    • Steel and Composite Structures
    • /
    • v.18 no.6
    • /
    • pp.1369-1389
    • /
    • 2015
  • In order to investigate the behaviour of lying multi-stud connectors in cable-pylon anchorage zone, twenty-four push-out tests are carried out with different stud numbers and diameters. The effect of concrete block width and tensile force on shear strength is investigated using the developed and verified finite element model. The results show that the shear strength of the lying multi-stud connectors is reduced in comparison with the lying single-stud connector. The reduction increases with the increasing of the number of studs in the vertical direction. The influence of the stud number on the strength reduction of the lying multi-stud connectors is decreased under combined shear and tension loads compared with under pure shear. Yet, due to multi-stud effect, they still can't be ignored. The concrete block width has a non-negligible effect on the shear strength of the lying multi-stud connectors and therefore should be chosen properly when designing push-out specimens. No obvious difference is observed between the strength reductions of the studs with 22 mm and 25 mm diameters. The shear strengths obtained from the tests are compared with those predicted by AASHTO LRFD and Eurocode 4. Eurocode 4 generally gives conservative predictions of the shear strength, while AASHTO LRFD overestimates the shear strength. In addition, the lying multi-stud connectors with the diameters of 22 m and 25 mm both exhibit adequate ductility according to Eurocode 4. An expression of load-slip curve is proposed for the lying multi-stud connectors and shows good agreement with the test results.