• Title/Summary/Keyword: addition tests

Search Result 3,852, Processing Time 0.039 seconds

Study on the frictional heat between wheel tread and brake shoe of EMU (도시철도 차량의 차륜답면-제륜자간 제동 마찰열에 관한 연구)

  • Yoon Cheon-Joo;Kim Seong-Keol;Goo Byeong-Choon
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.88-93
    • /
    • 2005
  • Frictional heat generates when the brake shoes are in contact with wheel tread under high pressure for EMU's speed control, stopping, and deceleration. Such a frictional heat has a significant effect on the wheel tread. In order to analyze the characteristics of frictional heat and measure the amount of the generated heat, tests by using a brake dynamometer and for running vehicles are carried out. In addition, finite element analysis is performed to simulate the temperature distribution and thermal analysis of the brake shoes. Through the tests and the simulations, it is found that the problems by temperature increase at tread braking are verified.

  • PDF

Effective test of lacquer in marine diesel engines

  • Hong, Sung-Ho;Ju, Seung-Hwan
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.9 no.2
    • /
    • pp.199-208
    • /
    • 2017
  • We perform an experiment on lacquer formation with simple test device. The anti-lacquer is one of important issues to increase durability, and to improve performance in the engines because the lacquer formation cause sticking of fuel injection pump, scuffing of cylinder liners, and increase of lubricant oil consumption in the marine diesel engines. We suggest this simple test in order to save enormous experimental cost in marine diesel engines, and in order to have ease in performing the various tests. The influences of the Base Number (BN) of lubricant oils and the sulfur content of fuel oils in the formation of lacquer are investigated. In order to investigate physical and chemical properties of lacquer, we perform a variety of tests such as, visual inspection, EDS. In addition, we investigate adhesion of lacquer by pull-off test quantitatively, and perform dissolution test with dilute sulfuric acid.

MODEL TESTS ON LEVEES REINFORCED WITH SHEET PILES UNDER HIGH WATER CONDITIONS WITH/WITHOUT SEISMIC LOADING HISTORY

  • Koseki, Junichi;Tanaka, Hiroyuki;Otsushi, Kazutaka;Nagao, Naoya;Kaneko, Masaru
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09c
    • /
    • pp.49-54
    • /
    • 2010
  • In order to study the performance of levees reinforced with steel sheet piles under high water condition, a series of model tests was conducted by simulating the high water condition before and after applying severe seismic loading history. As a result, the seepage behavior through the subsoil layers underlying the levee was not significantly affected by the seismic loading history. It was also verified that, irrespective of the seismic loading history, the sheet piles installed at the levee crest or shoulder are effective in preventing the breakage of levees caused by overflow. In addition, applicability of drainage works at the foot of the levee in preventing the seepage failure was confirmed.

  • PDF

Similitude in Flexural Bond Behavior of Small-Scale Reinforced Concrete Beams (축소모델 철근콘크리트 보의 휨부착거동에 있어서의 상사성)

  • 이한선;고동우
    • Journal of the Korea Concrete Institute
    • /
    • v.11 no.3
    • /
    • pp.47-57
    • /
    • 1999
  • The small-scale models have been utilized for the prediction of inelastic behavior of reinforced concrete structures for several decades. The parameters that affect the similitude between the model and prototype are various. Among them, the effect of bond between the model reinforcement and the model concrete is one of the most important factors. The study reported herein is addressed to verifying this similitude in bond behavior. The simple beams which have the lap splice at the midspan were made and flexural tests were performed under two-point loading. The length of lap splice are varied from 0.4ld through 0.7ld and up to 1.0ld where ld is the development length of the reinforcement. The selected scales are 1/1, 1/5, 1/10 and 1/12. Two prototype specimens and three models were tested in addition to the associated material tests and the test results are compared from the viewpoint of similitude.

A Study on Crack Behavior of Chemically Prestressed Steel Fiber Reinforced Concrete (화학적 프리스트레스가 도입된 강섬유 보강 콘크리트의 균열거동에 대한 연구)

  • Shim, Byul;Kim, Young-Kyun;Song, Ha-Won
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.121-124
    • /
    • 2004
  • In this paper, a series of fracture tests are performed for the chemically prestressed steel fiber reinforced concrete (SFRC) manufactured with addition of expansive additives for the study of fracture behavior and characteristics. Cracking loads of the chemically prestressed SFRC are greater than that of normal concrete and those are also increased by increasing of steel fiber volume. Thus, it is necessary to obtain optimum steel fiber volume to induce chemically prestressing effectively to concrete members. The result of three-points bending tests shows that early-cracking resistance of the chemically prestressed SFRC is increased without increase of fracture energy. From the test, the tension softening curves are also obtained by poly-linear approximation method and simulated behaviors by using the determined tension softening curves agree with experimental results. And it is confirmed that cracking and ultimate behaviors of chemically prestressed SFRC can be predicted by using obtained fracture characteristics.

  • PDF

On-line partial discharge measurement techniques of hydro-generator windings (수력 발전기 권선에서의 운전중 부분방전 측정기법)

  • 황동하;김진봉;김용주;박명수;김택수
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.45 no.2
    • /
    • pp.294-300
    • /
    • 1996
  • In hydro-generator, a groundwall insulation of stator windings gradually deteriorates due to mechanical, thermal, electrical and environmental stresses. These stresses combine to result in loose windings, delamination of the stator insulation and/or electrical tracking of the endwinding, all of which can lead to stator insulation failures. Conventionally, off-line tests such as partial discharge measurement, DC/AC current and .DELTA.tan.delta. tests has been used for estimation of winding condition. However, off-line test requires large power supply and generator outage. In addition, major cause of insulation problems such as loose wedges and slot dischages may not be found with off-line diagnoses. This paper introduces the on-line partial discharge measurement techniques using frequency spectrum analyzer(FSA) for the generator stator windings. The experimental results from the UIAM #1 hydro-generator confirms a optimistic application of on-line generator diagnosis method as a reliable tool for evaluation of winding condition.

  • PDF

An Analysis of Performance Testing for Metallic Connection Components of Lightning Protection System (피뢰시스템 구성부품 중 금속접속재의 성능시험 및 결과분석)

  • Lee, Ju-Cheol;Lee, An-Ki;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.7
    • /
    • pp.69-74
    • /
    • 2014
  • Recently, IEC published new standards about the requirements and tests for lightning protection system(LPS) components. If components are used for LPS, they should comply with the IEC standards. This paper, we collected six specimens for the metallic connection components using in domestic, and it tested for withstand lightning current which according to the IEC 62561-1. As a result, only one specimen meet this performance requirement. The specimen is the metallic connection component with four bolts fixed. Therefor, when designing of LPS in domestic, the metallic connection components shall be taken into account for the selection of the withstand lightning current. In addition, we need to develop for LPS components product and the national standards.

Assessment of Korean spring waters using a new mineral water index (맛있는 물 지표 개발을 통한 국내 약수 평가)

  • Lee, Seung-Jae;Lee, Sang-Eun;Kim, Jong-Gon;Park, Hee-Kyung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.1
    • /
    • pp.7-14
    • /
    • 2011
  • This study was motivated by the purpose of improving the O-Index, currently used to quantify water tasty. The authors first develop the M-Index after normalizing Ca, K, and $SiO_{2}$ concentrations in the spring water, in that the concentrations are subject to their log-normal distributions. The M-Index is then compared with the O-Index based on the results of sensory tests, revealing that sensory tests are correlated with the M-Index much more than the O-Index. Furthermore, the developed index is applied to evaluate water sampled from 53 springs in Korea. It is concluded that water, sampled from five most famous springs, has high values in M-Index. In addition, water, collected from springs that are relatively accessible, contains low values, and thus is expected not to tasty good.

Experimental Evaluation for Structural Performance of Hybrid Damper Combining Steel Slit and Rotational Friction Damper (강재 슬릿과 회전 마찰형 감쇠 장치를 결합한 복합 감쇠 장치의 실험적 구조 성능 평가)

  • Kim, Yu-Seong;Kang, Joo-Won;Park, Byung-Tae;Lee, Joon-Ho
    • Journal of Korean Association for Spatial Structures
    • /
    • v.19 no.3
    • /
    • pp.101-109
    • /
    • 2019
  • In order to develop the compatible damping device in various vibration source, a hybrid wall-type damper combining slit and friction damper in parallel was developed. Cyclic loading tests and two-story RC reinforced frame tests were performed for structural performance verification. As a result of the 5-cyclic loading test according to KBC-2016 and low displacement cyclic fatigue test, The hybrid wall type damper increased its strength and the ductility was the same as that of the slit damper. In addition, As a result of the two-layer frame test, the reinforced frame had about twice the strength of the unreinforced frame, and the story drift ratio was satisfied to Life Safety Level.

Numerical simulation of bridge piers with spread footings under earthquake excitation

  • Chiou, Jiunn-Shyang;Jheng, Yi-Wun;Hung, Hsiao-Hui
    • Earthquakes and Structures
    • /
    • v.16 no.6
    • /
    • pp.691-704
    • /
    • 2019
  • This study simulates the responses of large-scale bridge piers under pseudo-dynamic tests to investigate the performance of four types of numerical models that consider the nonlinear behavior of the pier and the rocking behavior of the footing. In the models, beam-column elements with plastic hinges are used for the pier, two types of foundation models (rotational spring and distributed spring models) are adopted for the footing behavior, and two types of viscous damping models (Rayleigh and dashpot models) are applied for energy dissipation. Results show that the nonlinear pier model combined with the distributed spring-dashpot foundation model can reasonably capture the behavior of the piers in the tests. Although the commonly used rotational spring foundation model adopts a nonlinear moment-rotation property that reflects the effect of footing uplift, it cannot suitably simulate the hysteretic moment-rotation response of the footing in the dynamic analysis once the footing uplifts. In addition, the piers are susceptible to cracking damage under strong seismic loading and the induced plastic response can provide contribution to earthquake energy dissipation.