• Title/Summary/Keyword: addition factor

Search Result 7,781, Processing Time 0.043 seconds

Determinants of susceptibility to global consumer culture (글로벌 소비자 문화 수용성의 결정변수)

  • Park, Hye-Jung
    • The Research Journal of the Costume Culture
    • /
    • v.22 no.2
    • /
    • pp.273-289
    • /
    • 2014
  • The purpose of this study is to identify the determinants of the susceptibility of global consumer culture. As determinants, materialism and self monitoring as psychological variables and fashion clothing product knowledge as clothing-related variable were included. It was hypothesized that both psychological variables and clothing-related variable influence susceptibility of global consumer culture. Data were gathered by surveying university students in Seoul metropolitan area, using convenience sampling, and 311 questionnaires were used in the statistical analysis. In analyzing data, exploratory factor analysis using SPSS and confirmatory factor analysis and path analysis using AMOS were conducted. Factor analysis of susceptibility of global consumer culture revealed four dimensions, 'social prestige' factor, 'quality perception' factor, 'conformity to others' factor, and 'conformity to consumption trend' factor. In addition, factor analysis of self monitoring revealed three dimensions, 'center-oriented attention' factor, 'situation-appropriate self-presentation' factor, and 'strategic displays of self-presentation' factor. The results showed that all the fit indices for the variable measures were quite acceptable. In addition, the overall fit of the model suggests that the model fits the data well. Tests of the hypothesized path show that all variables except for the one factor of self monitoring, 'center-oriented attention', and materialism influence all the factors of susceptibility of global consumer culture. The implications of these findings and suggestions for future study are also discussed.

Piezoelectric Properties of (K,Na)$NbO_3$ ceramics with the amount of KCN addition (KCN 첨가에 따른 (K,Na)$NbO_3$ 세라믹스의 압전특성)

  • Seo, Byeong-Ho;Sung, Kum-Hyun;Lee, Sang-Ho;Yoo, Ju-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.188-189
    • /
    • 2009
  • In this study, in order to develop excellent lead-free composition ceramics for piezoelectric transformer, $(K_4CuNb_8O_{23})$ added $(K_{0.5}Na_{0.5})(Nb_{0.96}Sb_{0.04})O_3$ ceramics were fabricated using conventional mixed oxide method and their piezoelectric and dielectric properties were investigated as a function of the amount of KCN addition. With increasing the amount of KCN addition, density and mechanical quality factor(Qm), electromechanical coupling factor (Kp) were increased up to 1.2mol% and then decreased. At the 1.2mol% KCN added specimen, mechanical quality factor (Qm), electromechanical coupling factor (Kp), density and dielectric constant (${\varepsilon}r$) showed the optimal values of 781, 0.445, $4.42g/cm^3$ and 443, respectively, for piezoelectric transformer application.

  • PDF

Dielectric and Piezoelectric Properties of (K,Na)NbO3 Ceramics with the amount of K4CuNb8O23 Addition (K4CuNb8O23 첨가에 따른 (K,Na)NbO3 세라믹스의 유전 및 압전특성)

  • Seo, Byeong-Ho;Yoo, Ju-Hyun;Mah, Suk-Burm;Jeong, Yeong-Ho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.11
    • /
    • pp.930-934
    • /
    • 2009
  • In this study, in order to develop excellent lead-free composition ceramics for piezoelectric transformer, ($K_4CuNb_8O_{23}$) added $(K_{0.5}Na_{0.5})(Nb_{0.96}Sb_{0.04})O_3$ ceramics were fabricated using conventional mixed oxide method and their piezoelectric and dielectric properties were investigated as a fu+EY50nction of the amount of KCN addition. With increasing the amount of KCN addition, density and mechanical quality factor(Qm), electromechanical coupling factor (Kp) were increased up to 1.2 mol% and then decreased. At the 1.2 mol% KCN added specimen, mechanical quality factor (Qm), electromechanical coupling factor (Kp), density and dielectric constant (${\varepsilon}r$) showed the optimal values of 781, 0.445, $4.42\;g/cm^3$ and 443, respectively, for piezoelectric transformer application.

Properties of $\beta$-1,3-glucan Synthase System in Saccharomyces cerevisiae (Saccharomyces cerevisiae의 베타-1,3-글루칸 합성효소 체계의 특성)

  • Park, Hee-Moon;Kim, Jeong-Yoon;Kim, Sung-Uk;Bok, Song-Hae
    • Microbiology and Biotechnology Letters
    • /
    • v.23 no.3
    • /
    • pp.316-321
    • /
    • 1995
  • Some properties of $\beta$-1, 3-glucan synthase system in Saccharamyces cerevisiae were investigated. By extraction with detergent and salt, the membrane preparations could be dissociated into two components, one soluble, the other still membrane bound. Both components, in addition to GTP, were necessary for the activity of $\beta$-1, 3-glucan synthase like other fungi. The protective effect of guanosine nucleotides on the soluble factor pointed to the possibility that this fraction contained a GTP-binding protein. Addition of increasing amounts of soluble factor to a constant amount of insoluble catalytic factor, vice versa, gave rise to a saturation curve. These results, including different types of evidence, indicate that the soluble factor and the catalytic factor form a complex.

  • PDF

A stability factor for structure-dependent time integration methods

  • Shuenn-Yih Chang;Chiu-Li Huang
    • Structural Engineering and Mechanics
    • /
    • v.87 no.4
    • /
    • pp.363-373
    • /
    • 2023
  • Since the first family of structure-dependent methods can simultaneously integrate unconditional stability and explicit formulation in addition to second order accuracy, it is very computationally efficient for solving inertial problems except for adopting auto time-stepping techniques due to no nonlinear iterations. However, an unusual stability property is first found herein since its unconditional stability interval is drastically different for zero and nonzero damping. In fact, instability might occur for solving a damped stiffness hardening system while an accurate result can be obtained for the corresponding undamped stiffness hardening system. A technique of using a stability factor is applied to overcome this difficulty. It can be applied to magnify an unconditional stability interval. After introducing this stability factor, the formulation of this family of structure-dependent methods is changed accordingly and thus its numerical properties must be re-evaluated. In summary, a large stability factor can result in a large unconditional stability interval but also lead to a large relative period error. As a consequence, a stability factor must be appropriately chosen to have a desired unconditional stability interval in addition to an acceptable period distortion.

Piezoelectric Properties of Pb-free Bi(Na,K)$TiO_3-SrTiO_3$ Ceramics with the Amount of $CeO_2$ Addition ($CeO_2$첨가에 따른 무연 Bi(Na,K)$TiO_3-SrTiO_3$ 세라믹스의 압전특성)

  • Lee, Hyun-Seok;Yoo, Ju-Hyun;Park, Chang-Yub;Jeong, Yeong-Ho;Hong, Jae-Il;Im, In-Ho;Yoon, Hyun-Sang
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.590-594
    • /
    • 2004
  • In this study, lead-free piezoelectric ceramics were investigated for pressure sensor applications as a function of the amount of $CeO_2$ addition at Bi(Na,K)$TiO_3-SrTiO_3$ system. With increasing the amount of $CeO_2$ addition, the density and dielectric constant increased. Electromechanical coupling factor($k_p$) showed the maximum value(kp, 0.39) at 0.1wt% $CeO_2$ addition and decreased above 0.1wt% $CeO_2$ addition., Density, dielectric constant(${\varepsilon}_r$) increased but mechanical quality factor(Qm), piezoelectric constant(d33) decreased in $CeO_2$ addition, respectively.

  • PDF

Piezoelectric Properties of (Na,K)NbO3 Ceramics as a Function of K5.4Cu1.3Ta10O29 Addition (K5.4Cu1.3Ta10O29 첨가에 따른 (Na,K)NbO3계 세라믹스의 압전특성)

  • Noh, Jung-Rae;Yoo, Ju-Hyun;Jeong, Yeong-Ho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.5
    • /
    • pp.379-382
    • /
    • 2010
  • In this study, in order to develop the lead-free piezoelectric ceramics with high piezoelectric and dielectric properties, $(K_{0.5}Na_{0.5})(Nb_{0.97}Sb_{0.03})O_3$ ceramics were fabricated using a conventional mixed oxide process and their piezoelectric and dielectric characteristics were investigated according to the $K_{5.4}Cu_{1.3}Ta_{10}O_{29}$ addition. $K_{5.4}Cu_{1.3}Ta_{10}O_{29}$ addition enhanced density, electromechanical coupling factor($k_p$) piezoelectric constant $d_{33}$ and mechanical quality factor($Q_m$). At the 0.9 mol% $K_{5.4}Cu_{1.3}Ta_{10}O_{29}$ addition, density, electromechanical coupling factor($k_p$), dielectric constant(${\varepsilon}_r$) and piezoelectric constant($d_{33}$) of specimen showed the optimum values of 0.46, 471, and 148 pC/N, respectively.

The Effect of the Determinants on the Intention-to-Use of Big Data System in Manufacturing Industry (제조업 종사자들의 빅데이터시스템 사용의도에 대한 결정요인의 영향)

  • Son, Dal Ho
    • The Journal of Information Systems
    • /
    • v.30 no.3
    • /
    • pp.159-175
    • /
    • 2021
  • Purpose The purpose of this study was to find the effect of the determinants on the Big data utilization in industry. The determinants of Big data utilization were deduced by reviewing theoretical background and discussions on Big data related researches. Research model and proposed hypothesis were constructed from TOE framework and UTAUT model. Design/methodology/approach The research was conducted to collect a sample data from the experts involved in the Big data projects in industry. In addition, interviews and online survey were performed to get sample data. Exploratory factor analysis was conducted to verify the grouping of these questionnaire items and confirmatory factor analysis was done to verify the validity and reliability of the measurement model. Finally, research hypothesis was verified and theoretical and practical implications were proposed for further studies. Findings The results show that the technical factor have a significant effect on the expectancy factor and the behavioral factor. The organizational factor have a significant effect on the behavioral factor. In addition, the expectancy factor was significant on the behavioral factor and the intention-to-use of Big data system.

Ihe Electrical and Piezoelectric Characteristics of PZT-PSN ceramics added $MnO_2$ ($MnO_2$가 첨가된 PZT-PSN압전세라믹의 압전 및 전기적특성 분석)

  • 김성곤;김철수;박정호;이상렬
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.161-164
    • /
    • 2001
  • In this paper, we investigated the dielectric and piezoelectric properties of Pb(Sb, Nb)O$_3$-Pb(Zr, Ti)O$_3$ ceramic(PSN) for piezoelectric transformer and actuator etc. Effect of MnO$_2$ addition on the PSN ceramic was investigated. Anisotropic properties of electromechanical coupling factor and piezoelectric properties proved to be varied with amount of MnO$_2$ impurity and sintering temperature. The electromechanical coupling factor k$_{p}$ of 0.38 and the mechanical quality factor Q$_{m}$ of 1944 were obtained from the specimen with 0.4 wt% MnO$_2$ sintered at 115$0^{\circ}C$ addition. Experimental results indicated that the PSN ceramic with MnO$_2$ impurity can be effectively used for piezoelectric transformer and actuator.tor.

  • PDF

A Study on the introduction of the outpatient and inpatient conversion factors in the 2020 Physician Fee Contract (외래⦁입원 환산지수에 기초한 2020년도 환산지수 산출 연구)

  • O, Dongil
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.4
    • /
    • pp.183-194
    • /
    • 2021
  • In this study, the conversion factor for 2020 is estimated based on an outpatient and inpatient conversion factor separation model developed from SGR and AR by using actual medical expense data. In addition, a policy plan is proposed to calculate the values of single and multiple conversion factors for each type of medical expense, and to effectively use the conversion factor separation model as one of the means to establish a medical delivery system. The major results are as follows. First, at r=0.1, the rate of adjustment in the hospital single conversion index in 2020 was 2.0%, and the outpatient and hospitalization conversion rates for hospitals were 2.2% and 2.3%, respectively. In addition, a combination of outpatient and inpatient conversion factors can be used for the adjustment. Second, as a measure to establish a medical delivery system, instead of adjusting the addition rate, a method of interlocking the addition rate and the conversion factor is proposed. Third, it is necessary to develop a model that enables target management of volumes, in addition to the outpatient conversion factor, the inpatient conversion factor, and the adjustment coefficient.