• Title/Summary/Keyword: adding zero

Search Result 90, Processing Time 0.069 seconds

Orthogonal Reception Characteristics for the DS/SS Signals with Time-shifted m-Sequences

  • Baek Kyung Hoon;Hyun Kwang Min;Yoon Dong Weon;Park Sang Kyu
    • Proceedings of the IEEK Conference
    • /
    • 2004.08c
    • /
    • pp.658-662
    • /
    • 2004
  • This paper proposes an orthogonal reception structure for OS/SS communication with time-shifted m-sequences, and compares the performances of the proposed and conventional receiver. This structure provides two important characteristics to reference user signal with not only increment of auto-correlation value but also cancel of the cross-correlation value out to zero between the reference user and other user signals. In addition, the structure can be easily implemented with the conventional receiver adding an additional integrator path in parallel and an adder that sums the conventional path output and the new path output signal. Hence, the proposed structure can be applied for channel impulse response measurement, and efficiently used for multi-user interference signal cancellation and channel capacity increment by flexible structural inter-working operation, connection or disconnection, of the new path to conventional receiver structure.

  • PDF

Vortex Shedding Frequency for a 2D Hydrofoil with a Truncated Trailing Edge (뒷날이 잘린 2차원 수중익의 와도 흘림 주파수)

  • Lee, Seung-Jae;Lee, Jun-Hyeok;Suh, Jung-Chun
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.51 no.6
    • /
    • pp.480-488
    • /
    • 2014
  • Vortex shedding which is the dominant feature of body wakes and of direct relevance to practical engineering problems, has been intensively studied for flows past a circular cylinder. In contrast, vortex shedding from a hydrofoil trailing edge has been studied to much less extent despite numerous practical applications. The physics of the problem is still poorly understood. The present study deals with $K{\acute{a}}rm{\acute{a}}n$ vortex shedding from a truncated trailing-edge hydrofoil in relatively high Reynolds number flows. The objectives of this paper are twofold. First, we aim to simulate unsteady turbulent flows past a two dimensional hydrofoil through a hybrid particle-mesh method and penalization method. The vortex-in-cell (VIC) method offers a highly efficient particle-mesh algorithm that combines Lagrangian and Eulerian schemes, and the penalization method enables to enforce body boundary conditions by adding a penalty term to the momentum equation. The second purpose is to investigate shedding frequencies of vortices behind a NACA 0009 hydrofoil operating at a zero angle of attack.

New ZVZCS PWM Converter For High Power Application (대전력 응용을 위한 새로운 ZVZCS PWM 컨버어터)

  • Ryoo, Hong-J.;Cho, Jung-G.;Yoo, Dong-W.;Rim, Geun-H.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.521-524
    • /
    • 1996
  • A new zero voltage and nero current switching(ZVZCS) full bridge(FB) PWM converter b proposed to improve the performance of the previously presented ZVZCS-FB-PWM converters [7,8]. By adding a secondary active clamp and controlling the clamp switch moderately, ZVS(for leading-leg switches) are ZCS(for lagging-leg switches) are achieved without nay lossy components, the reverie avalanche break down of leading-leg IGBTs[7] or the saturable reactor in the primary[8]. Many advantages including simple circuit topology, high efficiency, and low cost mate the new converter attractive for high voltage and high power(> 10 kW) applications. The principle of operation is explained and analyzed. The features and design considerations of the new converter are also illustrated and verified on an 1.8 kW, 100 kHz IGBT based experimental circuit.

  • PDF

An Analysis for The Ductile Crack Growth (연성 균열성장의 해석)

  • 구인회
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.1
    • /
    • pp.103-111
    • /
    • 1990
  • This paper presents a methodology for predicting stable crack growth and instability of a cracked body under monotonically increasing load. It is based on a model that incremental crack extensions and load increments after fracture initiation occur by turns in sequence and the criterion that the crack grows by an incremebt .delta.a when the opening displacement at the current crack tip increases by a critical value V$_{c}$. It is shown that the value I$_{c}$ = V$_{c}$/ .delta. a is a material constant characterizing ductile crack growth resistance. Along with the fracture initiation toughness value, the constant is used for the calculation of the loads against crack extensions by adding up each increment. The specimen failure is defined to occur when the necessary load increment for crack extension is zero or when the limit load in the current ligament is reached. The predicted failure loads are in good agreement with the avaliable experimental failure loads for the compact and center-cracked tension specimens of 7075-T651, 2024-T351 aluminum alloys and 304 stainless steel.steel.

Spectroscopic Studies on the Oxidation of Catechin in Aqueous Solution

  • Bark, Ki-Min;Yeom, Ji-Eun;Yang, Jeong-Im;Yang, Ik-Jun;Park, Chul-Ho;Park, Hyoung-Ryun
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.9
    • /
    • pp.3443-3447
    • /
    • 2011
  • The spectroscopic behavior of catechin (5,7,3',4'-tetrahydroxyflavan-3-ol), has been studied in the presence and the absence of air using UV-vis absorption spectrophotometry and fluorescence spectroscopy. The UV-vis absorption spectrum of catechin shows a very sharp and strong absorption maximum peak at 275 nm in deaerated water. New absorption maximum peaks appeared in aerated water, as well as in basic aqueous solution, caused by the oxidation of catechin. The absorbances in the UV-vis absorption spectrum of catechin decreased when the solution was left in the dark for a long time. The fluorescence emission spectrum of catechin after a long time period differs markedly from that in freshly prepared solution; the fluorescence maxia shifted as time passes after adding catechin to the solutions. When the deaerated basic catechin solutions were left in the dark for a long time, their fluorescence quantum yields were found to be nearly zero. This suggests that the oxidized catechin molecules were seen to have slowly undergone successive chemical reactions in basic buffer solution.

Liquid-phase Thermal Degradation Properties of Waste Plastic Film (폐플라스틱 필름의 액상 열분해 특성에 관한 연구)

  • Hwang, T.S.;Kim, Y.S.;Kang, T.W.;Hwang, E.H.
    • Proceedings of the Korean Institute of Resources Recycling Conference
    • /
    • 2003.10a
    • /
    • pp.116-121
    • /
    • 2003
  • In this study, the thermal degradation process has been investigated at various reaction temperature$(350{\sim}400^{\circ}C)$ and times$(30{\sim}120\;min)$ in order to recycle waste plastic films as solid state wax. Waste plastic films were easily melted by adding a small amount of waxes. The effects of wax addition and nitrogen flow rate on their thermal degradation properties were investigated. FT-IR, GPC and viscometer were used to analyze properties of the solid wax including the structure, molicular weight distribution and melt viscosity. The average molecular weight of solid wax was decreased with increasing the reaction time, temperature and amount of wax added, Also, the viscosity of solid wax decreased with increasing the stirring speed at a constant reaction temperature and time, and its viscosity got close to zero above $390^{\circ}C$.

  • PDF

Initial Rotor Position Detection of Single-phase Permanent Magnet Synchronous Motor using Offset Voltage (옵셋 전압을 이용한 단상 영구자석 동기 전동기의 초기 회전자 위치 검출)

  • Hwang, Seon-Hwan;Seo, Sung-Woo;Jung, Tae-Uk
    • Journal of IKEEE
    • /
    • v.23 no.2
    • /
    • pp.622-627
    • /
    • 2019
  • This paper propose an initial rotor position detection method for sensorless operation of a single-phase permanent magnet synchronous motor(SP-PMSM) with asymmetric air-gap. In general, the sensorless control based on back-emf estimation is difficult to estimate the back-emf at the zero and low speed regions. For this reason, an open loop start-up technique is indispensable, and it is also necessary to detect the initial position of the rotor in order to rotate in a certain direction. In this paper, we propose a method to detect rotor polarity by adding offset voltage to high frequency voltage signal based on the magnetic characteristics of SP-PMSM. The validity and usefulness of the proposed algorithm are verified through several experimental results.

High-Performance Tracking Controller Design for Rotary Motion Control System (회전운동 제어시스템을 위한 고성능 추적제어기의 설계)

  • Kim, Youngduk;Park, Su Hyeon;Ryu, Seonghyun;Song, Chul Ki;Lee, Ho Seong
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.11
    • /
    • pp.43-51
    • /
    • 2021
  • A robust tracking controller design was developed for a rotary motion control system. The friction force versus the angular velocity was measured and modeled as a combination of linear and nonlinear components. By adding a model-based friction compensator to a nominal proportional-integral-derivative controller, it was possible to build a simulated control system model that agreed well with the experimental results. A zero-phase error tracking controller was selected as the feedforward tracking controller and implemented based on the estimated closed-loop transfer function. To provide robustness against external disturbances and modeling uncertainties, a disturbance observer was added in the position feedback loop. The performance improvement of the overall tracking controller structure was verified through simulations and experiments.

Studies on the Effect of Cation on the Activity at the 5th Instar Larvae of Bombyx mori (5령유충의 배맥관운동에 대한 양이온의 영향에 관한 연구)

  • 윤종관;사기언
    • Journal of Sericultural and Entomological Science
    • /
    • v.18 no.2
    • /
    • pp.89-93
    • /
    • 1976
  • The physiological saline solution for animals is known as Ringer's solution which is used for keeping the function of cold blooded vertebrate animals. Primaily the saline solution is used for the purpose of perfusion experiment in frogs. Later the saline solution is applied in several kinds of animals including human being with satisfactory results. However, this saline solution was introduced to silkworm and it was found that the result was not as successful as in the case of other animals and human being. Normally, in the case of silkworm, the physiological saline solution is prepared in order to maintain the normal function of separated organs and tissues. To this end, the saline solution is adjusted to contain the certain amount and strength of ions, osmosis pressure and hydrogen concentration. The most of cases, the physiological saline solution should be prepared so that the constituent of the solution be the same with the blood selium and body fluid. The hydrogen concentration in the ion element of the saline solution is adjustable by adding Na$\^$+/, K$\^$+/, Ca$\^$++/, Mg$\^$++/ which are followed by adding of buffer solution such as NaHCO$_3$and NaH$_2$PO$_4$. Determination of optimum concentration of cation in the physiological saline solution, and the optimum mixing rate of more than two kinds of cations are based on the movement of dorsal vessel in the silkworm larvae. The optimum concentration of cations in the solution is prepared by adding NaCl solution which is under zero point. However, this solution was further added with the different concentration of KCl and CaCl$_2$. By dropping the prepared solution on the 5th larvae, the effects of solution was measured. The measurement was done by observation of movement' of dorsal vessel and its time length, and the number of pulses. According to the experiment, it was found that when only NaCl solution was applied, the number of pulses is increased for a moment, and the pulse stopped after one hour or so. When KCl solution was added the time of pulse was prolonged and in the contrast, the number of pulses was slow down. If KCl and CaCl$_2$solutions are added the time of pulse was further prolonged. Even though the adding of KCl and CaCl$_2$are found to be effectible, the correlation between the concentration of solution and the movement of dorsal vessel was not observed. However, it was same in the case of adding Ca$\^$++/ or K$\^$+/. It was found that when Mg$\^$++/ was added to dorsal vessel the number of the pulses was not decreased although the prolonged time pulse was observed.

  • PDF

The Release of Albumin from PLGA and PCL Wafers Containing Natural and Synthetic Additives for Protein Delivery (단백질 전달체로서 천연 및 합성재료의 첨가에 따른 PLGA와 PCL웨이퍼로부터 알부민의 방출거동)

  • Hyun Hoon;Lee Jae Ho;Seo Kwang Su;Kim Moon Suk;Rhee Jhon M.;Lee Hai Bang;Khang Gilson
    • Polymer(Korea)
    • /
    • v.29 no.5
    • /
    • pp.468-474
    • /
    • 2005
  • PLGA and PCL copolymers initiated by carbitol as drug carriers were synthesized by ring-opening polymerization of L-lactide (LA), glycolide (GA), and $\varepsilon-caprolactone(\varepsilon-CL)$. Implantable wafers were simply fabricated by direct compression method after physical mixing of copolymers and bovine serum albumin-fluorescein isothiocyanate (BSA-FITC) as a model protein drug. The release amounts of BSA-FITC from wafers were determined by fluorescence intensity using the fluorescence spectrophotometer. Also, the release behavior of BSA-FITC on wafers was controlled by adding the additives such as collagen, small intestinal submucosa (SIS), poly(vinyl pyrrolidone) (PVP), and poly(thylene glycol) (PEG). The wafer prepared by PLGA and PCL exhibited slow release within $10\%$ for 30 days. But, those prepared by a variety of additives exhibited the controlled BSA release patterns with a dependence on the additive contents. furthermore, the wafers containing natural materials such as collagen and SIS showed more zero-order release profile than that with synthetic materials such as PVP and PEG. It was confirmed that the release of BSA from implantable wafers could be easily controlled by adding natural additives.