• Title/Summary/Keyword: acupuncture controller

Search Result 5, Processing Time 0.019 seconds

Design of Acupuncture Controller and Dummy for Acupuncture Training System based MR (MR 기반 침술 훈련 시스템을 위한 침술 컨트롤러 및 인체모형 설계)

  • Ryu, Chang Ju;Lee, Sang Duck;Han, Seung Jo
    • Smart Media Journal
    • /
    • v.9 no.2
    • /
    • pp.86-91
    • /
    • 2020
  • The current trend of the education market is the development of the fourth industrial revolution and the development of ICT, and various technologies are developing into edu-tech technology that is integrated into the education system. In particular, the market for edu-tech systems capable of lifelike immersive learning effects in virtual space is expanding. However, education in Korean medicine is not objective because of the absence of educational simulators and systems to train and evaluate acupuncture. In this paper, we propose an acupuncture controller and a human body model to increase the effectiveness of acupuncture point training as a follow-up study of "Design of Acupuncture Contents and Dummy for Acupuncture Point Training System". Through the proposed acupuncture controller and Dummy, the accuracy of acupuncture points for the acupuncture point data matching and content motion recognition rate is presented. In addition, the results of temperature and humidity and temperature change tests for evaluating the environmental reliability of the controller are presented.

Development of a Microcurrent acupuncture point treatment equipment (미세전류 경혈치료기의 개발)

  • Jung, Won-Ki;Kim, Young-Suk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.8
    • /
    • pp.2958-2962
    • /
    • 2010
  • We developed a Microcurrent acupuncture point treatment equipment using micro-controller AVR. This equipment can generate a sine wave, triangle wave, square wave and DC. The frequency range of waves like the sine wave and the triangle wave is 1 - 320 Hz and the output range of DC is $40-200\;{\mu}A$. The duration is controllable between a minute to 30 minutes.

A Study on the Acupuncture Point Resistance Characteristics(II) (경혈 저항특성에 관한 연구(II))

  • Kim, E.S.;Han, S.C.;Choi, T.J.;Kim, J.K.;Hur, Woong;Park, Y.B.
    • Proceedings of the IEEK Conference
    • /
    • 2001.06e
    • /
    • pp.69-72
    • /
    • 2001
  • In this paper, we study about a acupuncture point and a non-acupuncture point resistance characteristics for acupuncture research. For this study, we devised resistance variation measurement system. This system is consist of 4-channel skin resistance measuring parts, filters, 12bit A/D convertor, 8051 micro-controller, and personal computer The developed system insert a low current to skin and obtains voltages from standard resistor that is convected to measurement circuit in series. The obtained voltage is converted to 12bit digital signal. Therefore the converted signal is changed to skin resistance by calculation in the personal computer. As the results of experiment, the resistance of acupuncture point and non-acupuncture point are different from each other. The acupuncture point has very fast current flows than the other non- acupuncture point.

  • PDF

A Development of Multi-Channel Acupuncture Point Balance Measurement System (다채널 경혈평형 계측 시스템 구현에 관한 연구)

  • Kim, Chang-Mo;Kim, Eung-Soo;Han, Soon-Chen;Kim, Jung-Kuk;Huh, Woong
    • Proceedings of the IEEK Conference
    • /
    • 2003.07c
    • /
    • pp.2903-2906
    • /
    • 2003
  • In this paper, we developed a multichannel acupuncture point balance measurement system that measures skin resistances at various acupuncture points to evaluate the balancing state of the meridian. The system consists of 16 channel resistance-voltage converter, signal processing part for signal amplification and filtering, A/D conversion part, micro-controller part, and data processing part. Compared to the previously developed 1 channel or 4 channel systems, it is found that the 16 channel system can measure the skin resistances of 16 acupuncture points, simultaneously, providing various clinical information such as balance and variation of the resistance value.

  • PDF

Self-controller of Saam Acupuncture Viewed from the Aspect of the Five Viscera Interaction (오장상섭(五臟相涉)의 측면에서 살펴본 사암침법(舍岩鍼法)의 억관(抑官)과 보관(補官))

  • Oh, Jun-Ho
    • Korean Journal of Acupuncture
    • /
    • v.28 no.3
    • /
    • pp.127-140
    • /
    • 2011
  • Objectives : The aim of this study is to regulate the medical meaning about Kwan [self-denial] which is used by Jeongkyeok [reinforcing the weak body part] and Seungkyeok [consolidating the weak body part while inducing cathartic action of comparatively stronger body part] of Saam Acupuncture in common. Methods : This study generalized the method of understanding 'The Five Viscera Interaction' in Oriental Medicine from the perspective of literature and considering human organs in the medical context. Results and Conclusions : 1. There existed 'The Five Viscera Interaction' theory regulating the correlation between the five viscera headed by "Nankyeong" in the traditional Oriental medicine. The five viscera interaction theory was used as the standard of judging the symptom and the prognosis of a disease in the history of Oriental medicine and further used even as the method of preventing and treating diseases. 2. The treatment included in "Biyebaekyobang", a medical book in the period of Goryeo, can be rated as the most developmental form of medical theory which applied 'the five viscera interaction theory' to clinical treatment. The author of "Biyebaekyobang" managed to break away from the schematism of the five viscera interaction through the method of treating two internal organs using one organ treatment and applying the individually different relations between organs. "Biyebaekyobang" shows close similarities to Saam Acupuncture. 3. The organs handled in Saam Acupuncture has a significance in that it put forward the part which had not been aggressively dealt with in medical history up until then.