• Title/Summary/Keyword: active shielding

Search Result 38, Processing Time 0.03 seconds

아크 용접에서 구동력에 따른 열 및 물질 유동에 관한 연구

  • 김원훈;나석주
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 1996.11a
    • /
    • pp.27-41
    • /
    • 1996
  • In this study the heat transfer and fluid flow of the molten pool in stationary gas tungsten arc welding using argon shielding gas were investigated. Transporting phenomena from the welding arc to the base material surface, such as current density, heat flux, arc pressure and shear stress acting on the weld pool surface, were taken from the simulation results of the corresponding welding arc. Various driving forces for the weld pool convection were considered, self-induced electromagnetic, surface tension, buoyancy, and impinging plasma arc forces. Furthermore, the effect of surface depression due to the arc pressure acting on the molten pool surface was considered. Because fusion boundary has a curved and unknown shape during welding, a boundary-fitted coordinate system was adopted to precisely describe the boundary for the momentum equation. The numerical model was applied to AISI 304 stainless steel and compared with the experimental results.

  • PDF

3-Dimensional Design of Gradient Coils for Magnetic Resonance Imaging (자기공명영상촬영용 경사자계코일의 3차원설계)

  • Ryu, Yeun-Chul;Hyun, Jung-Ho;Lee, Heung-K.;Oh, Chang-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2006.10c
    • /
    • pp.235-237
    • /
    • 2006
  • In this paper, the previous 2-D gradient coil design method using loop current elements is extended to 3-D or multi-layer structures which is useful for various MRI applications including MR microscopic imaging where relatively large space may be available for the implementation of the gradient coils. Either the power consumption or the stored energy (thus, inductance), or the combination of the two can be minimized with a set of chosen target field constraints. Complete 3-D design equations for the optimization as well as inductance or resistance calculation are derived. An effective coil shape correction method for a curved current pattern is also developed. The design method can also be easily extended to the active shielding structure.

  • PDF

Actively controlled sound field on the top edge of noise barriers for railway noise reduction (철도소음 저감 향상을 위한 방음벽 상단의 능동제어장치)

  • Koh Hyo-In;Cho Joon-Ho;Kim Jae-Chul;Lee Chan-Woo;Han Hwan-Su
    • Proceedings of the KSR Conference
    • /
    • 2005.05a
    • /
    • pp.332-337
    • /
    • 2005
  • In this study the sound field on the surface of the top edge of noise barriers is actively minimized to enhance the shielding effect without increasing the hight of the barrier. First the results of a numerical study are shown; the sound field reduction in the far field due to a cylindrical active headpiece attached to a semi-infinite screen and the related control parameters are investigated. The results of a model experiment in an anechoic chamber and optimal control parameters for noise control on the railway side are shown and discussed.

  • PDF

Study on the quench protective circuit for inductively coupled superconducting magnet systems (자기적으로 결합된 초전도 마그네트의 퀜치보호에 대한 연구)

  • Ko, Rock-Kil;Bae, Joon-Han;Sim, Ki-Deok;Kwon, Young-Kil;Ryu, Kang-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2001.04a
    • /
    • pp.41-43
    • /
    • 2001
  • We studied on effective quench protection method to prevent damage from unexpected quench of the inductively coupled superconducting magnet systems for magnetic resonance imaging. And we suggested quench protection circuit that is combined with several protection techniques. This circuit has the capacity to maintain the symmetric nature of the magnetic field and the active shielding effect and to protect shim coils during a quench.

  • PDF

Voltammetric Analysis on a Disposable Microfluidic Electrochemical Cell

  • Chand, Rohit;Han, Dawoon;Kim, Yong-Sang
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.4
    • /
    • pp.1175-1180
    • /
    • 2013
  • A microfabricated electrochemical cell comprising PDMS-based microchannel and in-channel gold microelectrodes was fabricated as a sensitive and a miniature alternative to the conventional electroanalytical systems. A reproducible fabrication procedure enabled patterning of multiple microelectrodes integrated within a PDMS-based fluidic network. The active area of each electrode was $200{\mu}m{\times}200{\mu}m$ with a gap of $200{\mu}m$ between the electrodes which resulted in a higher signal to noise ratio. Also, the PDMS layer served the purpose of shielding the electrical interferences to the measurements. Analytes such as potassium ferrocyanide; amino acid: cysteine and nucleoside: guanosine were characterized using the fabricated cell. The microchip was comparable to bulk electrochemical systems and its applicability was also demonstrated with flow injection based rapid amperometric detection of DNA samples. The device so developed shall find use as a disposable electrochemical cell for rapid and sensitive analysis of electroactive species in various industrial and research applications.

Graphene field-effect transistor for radio-frequency applications : review

  • Moon, Jeong-Sun
    • Carbon letters
    • /
    • v.13 no.1
    • /
    • pp.17-22
    • /
    • 2012
  • Currently, graphene is a topic of very active research in fields from science to potential applications. For various radio-frequency (RF) circuit applications including low-noise amplifiers, the unique ambipolar nature of graphene field-effect transistors can be utilized for high-performance frequency multipliers, mixers and high-speed radiometers. Potential integration of graphene on Silicon substrates with complementary metal-oxide-semiconductor compatibility would also benefit future RF systems. The future success of the RF circuit applications depends on vertical and lateral scaling of graphene metal-oxide-semiconductor field-effect transistors to minimize parasitics and improve gate modulation efficiency in the channel. In this paper, we highlight recent progress in graphene materials, devices, and circuits for RF applications. For passive RF applications, we show its transparent electromagnetic shielding in Ku-band and transparent antenna, where its success depends on quality of materials. We also attempt to discuss future applications and challenges of graphene.

Noise Characteristics of 64-channel 2nd-order DROS Gradiometer System inside a Poorly Magnetically-shielded Room (저성능 자기차폐실에서 64채널 DROS 2차 미분계 시스템의 잡음 특성)

  • Kim, J.M.;Lee, Y.H.;Yu, K.K.;Kim, K.;Kwon, H.;Park, Y.K.;Sasada, Ichiro
    • Progress in Superconductivity
    • /
    • v.8 no.1
    • /
    • pp.33-39
    • /
    • 2006
  • We have developed a second-order double relaxation oscillation SQUID(DROS) gradiometer with a baseline of 35 mm, and constructed a poorly magnetically-shielded room(MSR) with an aluminum layer and permalloy layers for magnetocardiography(MCG). The 2nd-order DROS gradiometer has a noise level of 20 $fT/{\surd}Hz$ at 1 Hz and 8 $fT/{\surd}Hz$ at 200 Hz inside the heavily-shielded MSR with a shielding factor of $10^3$ at 1 Hz and $10^4-10^5$ at 100 Hz. The poorly-shielded MSR, built of a 12-mm-thick aluminum layer and 4-6 permalloy layers of 0.35 mm thickness, is 2.4mx2.4mx2.4m in size, and has a shielding factor of 40 at 1 Hz, $10^4$ at 100 Hz. Our 64-channel second-order gradiometer MCG system consists of 64 2nd-order DROS gradiometers, flux-locked loop electronics, and analog signal processors. With the 2nd-order DROS gradiometers and flux-locked loop electronics installed inside the poorly-shielded MSR, and with the analog signal processor installed outside it, the noise level was measured to be 20 $fT/{\surd}Hz$ at 1 Hz and 8 $fT/{\surd}Hz$ at 200 Hz on the average even though the MSR door is open. This result leads to a low noise level, low enough to obtain a human MCG at the same level as that measured in the heavily-shielded MSR. However, filters or active shielding is needed fur clear MCG when there is large low-frequency noise from heavy air conditioning or large ac power consumption near the poorly-shielded MSR.

  • PDF

High Efficiency Active Phased Array Antenna Based on Substrate Integrated Waveguide (기판집적 도파관(SIW)을 기반으로 하는 고효율 능동 위상 배열안테나)

  • Lee, Hai-Young
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.3
    • /
    • pp.227-247
    • /
    • 2015
  • An X-band $8{\times}16$ dual-polarized active phased array antenna system has been implemented based on the substrate integrated waveguide(SIW) technology having low propagation loss, complete EM shielding, and high power handling characteristics. Compared with the microstrip case, 1 dB less is the measured insertion loss(0.65 dB) of the 16-way SIW power distribution network and doubled(3 dB improved) is the measured radiation efficiency(73 %) of the SIW sub-array($1{\times}16$) antenna element. These significant improvements of the power division loss and the radiation efficiency using the SIW, save more than 30 % of the total power consumption, in the active phased array antenna systems, through substantial reduction of the maximum output power(P1 dB) of the high power amplifiers. Using the X-band $8{\times}16$ dual-polarized active phased array antenna system fabricated by the SIW technology, the main radiation beam has been steered by 0, 5, 9, and 18 degrees in the accuracy of 2 degree maximum deviation by simply generating the theoretical control vectors. Performing thermal cycle and vacuum tests, we have found that the SIW array antenna system be eligible for the space environment qualification. We expect that the high efficiency SIW array antenna system be very effective for high performance radar systems, massive MIMO for 5G mobile systems, and various millimeter-wave systems(60 GHz WPAN, 77 GHz automotive radars, high speed digital transmission systems).

Minimum-Power Design of Actively-Shielded Transverse Gradient Coils for MRI (MRI용 차폐된 X,Y-경사자계코일의 최소전력설계)

  • Lee, D.R.;Kim, S.K.;Yang, Y.J.;Lee, H.K.;Ahn, C.B.;Oh, C.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.11
    • /
    • pp.307-309
    • /
    • 1996
  • A new design scheme of actively-shielded x,y-gradient coils for Magnetic Resonance Imaging(MRI) is proposed. An actively-shielded x-gradient coil has been designed as an example and the results are presented. In MRI, gradient coils are needed for spatial selection and position coding to obtain the position information of the NMR signal. They are usually switched on and off during imaging and the eddy current induced by the current switching usually degrades the final image quality To reduce or remove this kind of problems, the active shielding has been proposed few years ago. In this paper, a new design scheme for actively-shielded x,y-gradient coils, namely, a minimum-power design scheme using current-loop elements, has been proposed. Its utility in designing MRI gradient coils has been shown by using simulation. The design scheme seems to be useful for actively-shielded transverse gradient coils, even of non-cylindrical or of arbitrary-selected shapes.

  • PDF

The effect of ionizing radiation on robotic trajectory movement and electronic components

  • Sofia Coloma;Paul Espinosa Peralta;Violeta Redondo;Alejandro Morono;Rafael Vila;Manuel Ferre
    • Nuclear Engineering and Technology
    • /
    • v.55 no.11
    • /
    • pp.4191-4203
    • /
    • 2023
  • Robotics applications are greatly needed in hazardous locations, e.g., fusion and fission reactors, where robots must perform delicate and complex tasks under ionizing radiation conditions. The drawback is that some robotic parts, such as active electronics, are susceptible to radiation. It can lead to unexpected failures and early termination of the robotic operation. This paper analyses the ionizing radiation effect from 0.09 to 1.5 Gy/s in robotic components (microcontrollers, servo motors and temperature sensors). The first experiment compares the performance of various microcontroller types and their actuators and sensors, where different mitigation strategies are applied, such as using Radiation-Hardened (Rad-Hard) microcontrollers or shielding. The second and third experiments analyze the performance of a 3-Degrees of Freedom (DoF) robotic arm, evaluating its components' responses and trajectory. This study enhances our understanding and expands our knowledge regarding radiation's impact on robotic arms and components, which is useful for defining the best strategies for extending the robots' operational lifespan, especially when performing maintenance or inspection tasks in radiation environments.