• 제목/요약/키워드: active shield method

검색결과 8건 처리시간 0.024초

능동 차폐 MRI 초전도 자석에 대한 최적 설계 방법 (Optimal Design Method for an Actively Shielded MRI Superconducting Magnet)

  • 이광호;조윤현
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권6호
    • /
    • pp.421-430
    • /
    • 2000
  • This paper describes an optimal design method which is applied a weighted least square (WLS) method for Magnetic Resonance Imaging (MRI) system. An optimal design approach is presented for a homogeneity superconducting magnet with the superconducting active shield especially for a magnetic resonance imaging system. The WLS is used to obtain the optimal configurations using the least amount and minimum volume of conductor, exhibiting the smallest level of field inhomogeneity and resulting in the least level of stray field. The proposed model is used to design a multiple-shield configuration for a 1.5 T MRI magnet. The field homogeneity is required less than 5 gauss stray field contour within 4m axially and 3m radially from origin. The designed magnet with the actively magnetic shielding coil out of main coils is analyzed by FEM and theoretical analysis method, investigated the field homogeneity.

  • PDF

용량성 결합 능동 전극의 공통 모드 구동 차폐 (A Study on comnon-mode-driven shield for capacitive coupling active electrode)

  • 임용규
    • 융합신호처리학회논문지
    • /
    • 제13권4호
    • /
    • pp.201-206
    • /
    • 2012
  • 간접접촉 심전도 측정(Indirect-Contact ECG)은 일상생활에서의 무구속 무자각 측정에 적합한 심전도 측정 방법이다. 본 연구는, 간접접촉 심전도 측정에서 크게 관측되는 60Hz 전원선 잡음을 줄이기 위한 새로운 방법으로, 공통모드 구동 차폐 방식을 제안하였다. 공통 모드 구동 차폐 방식은, 간접 접촉 심전도에서 사용되는 용량성 결합 능동 전극(Capacitive coupling active electrode)을 둘러싼 전기적 차폐(electric shield)의 전압을 공통 모드 전압과 동일하게 유지하는 방법이다. 이 방법은 공통모드 전압의 크기는 그대로 유지하지만, 의복 임피던스 차에 의한 공통모드 전압의 차동 모드 전환에 의한 잡음은 효과적으로 줄일 수 있다. 따라서 두 전극 사이의 의복의 임피던스 차이가 커서 공통 모드 전원 잡음이 심각한 간접 접촉 심전도 측정에서, 효과적으로 공통 모드 잡음을 줄일 수 있다. 실제 간접 접촉 심전도 측정에 제안된 방법을 적용한 결과로 이론적 예상보다는 60Hz 잡음 감소비가 적었지만, 60Hz 잡음이 크게 줄어드는 것을 확인할 수 있었다. 특히 의복 임피던스 차가 크게 발생하는 경우, 예상대로 잡음 감소비가 커짐을 볼 수 있었다. 제안된 방법은 접지 특성이 좋지 않은 측정 조건에서 전원 잡음을 줄이는데 유용할 것으로 기대된다.

고균일 자계발생용 초전도 능동차폐 마그네트의 설계에 관한 연구 (A Design Approach for High Homogeneity Superconducting Magnet with Superconducting Active Shield)

  • 이광호;김성도;조윤현;이재복
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.151-153
    • /
    • 1996
  • An optimal design approach is presented for high homogeneity superconducting magnet with superconducting active shield especially for use in magnetic resonance imaging system. This paper is investigated phenomena for the stray magnetic field to get a basic reduction techniques of the unwanted stray magnetic field from the magnet. The present method obtains optimal coil configuration considering constraints for magnetic field homogeneity and leakage field.

  • PDF

Practical Silicon-Surface-Protection Method using Metal Layer

  • Yi, Kyungsuk;Park, Minsu;Kim, Seungjoo
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제16권4호
    • /
    • pp.470-480
    • /
    • 2016
  • The reversal of a silicon chip to find out its security structure is common and possible at the present time. Thanks to reversing, it is possible to use a probing attack to obtain useful information such as personal information or a cryptographic key. For this reason, security-related blocks such as DES (Data Encryption Standard), AES (Advanced Encryption Standard), and RSA (Rivest Shamir Adleman) engines should be located in the lower layer of the chip to guard against a probing attack; in this regard, the addition of a silicon-surface-protection layer onto the chip surface is a crucial protective measure. But, for manufacturers, the implementation of an additional silicon layer is burdensome, because the addition of just one layer to a chip significantly increases the overall production cost; furthermore, the chip size is increased due to the bulk of the secure logic part and routing area of the silicon protection layer. To resolve this issue, this paper proposes a practical silicon-surface-protection method using a metal layer that increases the security level of the chip while minimizing its size and cost. The proposed method uses a shift register for the alternation and variation of the metal-layer data, and the inter-connection area is removed to minimize the size and cost of the chip in a more extensive manner than related methods.

능동 차폐형 초전도 MRI 마그네트의 형상 최적화 (Shape Optimization of Active Shield Superconducting MRI Magnet)

  • 진홍범;오봉환;류강식;송준태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.210-212
    • /
    • 1996
  • A nonlinear optimization method for the shape optimization of actively shielded superconducting MRI magnet is presented. The presented design method can optimize both main coil and shielding coil simultaneously by setting constraints on stray field intensity at a specified distance from the magnet center. A 1 Tesla actively shielded superconducting MRI magnet, with 30cm bore diameter, is designed using the presented method.

  • PDF

The Attenuation Structure of the South Korea: A review

  • Chung, T. W.;Noh, M. H.;Matsumoto, S.
    • 지구물리
    • /
    • 제9권3호
    • /
    • pp.199-207
    • /
    • 2006
  • Fukuoka earthquake on March 20, 2005 showed the potential hazard of large events out of S. Korea. From the viewpoint of seismic hazard, seismic amplitude decrease Q-1 is very important. Related to the crustal cracks induced by the earthquakes, the value of Q-1- high Q-1 regions are more attenuating than low Q-1 regions - shows a correlation with seismic activity; relatively higher values of Q-1 have been observed in seismically active areas than in stable areas. For the southeastern and central S. Korea, we first simultaneously estimated QP-1 and QS-1 by applying the extended coda-normalization method to KIGAM and KNUE network data. Estimated QP-1 and QS-1 values are 0.009 f-1.05 and 0.004 f-0.70 for southeastern S. Korea and 0.003 f -0.54 and 0.003 f -0.42 for central S. Korea, respectively. These values agree with those of seismically inactive regions such as shield. The low QLg-1 value, 0.0018f -0.54 was also obtained by the coda normalization method. In addition, we studied QLg-1 by applying the source pair/receiver pair (SPRP) method to both domestic and far-regional events. The obtained QLg-1 for all Fc is less than 0.002, which is reasonable value for a seismically inactive region.

  • PDF

HPLC Chromatographic Methods for Simultaneous Determination of Pholcodine and Ephedrine HCI with Other Active Ingredients in Antitussive-Antihistamine Oral Liquid Formulations

  • Abdallah, Rokia M.
    • Natural Product Sciences
    • /
    • 제12권1호
    • /
    • pp.55-61
    • /
    • 2006
  • A description of simple, isocratic and precise reversed phase HPLC methods is given for simultaneous quantification of pholcodine and ephedrine hydrochloride together with either carbinoxamine maleate or terfenadine in antitussive-antihistaminic oral pharmaceutical formulations. Separations were carried out on X-Terra and symmetry shield C18 column $(250\;{\times}\;4.6\;mm,\;5\;{\mu}m)$. The used isocratic elution systems were either $0.02\;M\;KH_2PO_4-acetonitrile$ in the ratio of 75 : 25 and pH adjusted to 7.70 with orthophosphoric acid or sodium hydroxide, for syrup (method A), or 0.02 octanesulphonic acid sodium salt solution-acetonitrile-acetic acid in the ratio of 75 : 25 : 0.5 for suspension (method B). The elution of both mixtures was achieved with a flow rate of 1 ml/min. Detection was carried out by UV absorbance at wavelengths of 220 and 250 nm for syrup and suspension, respectively. The quantification of the components in synthetic mixtures and actual syrup and suspension were calculated using the internal standard technique with metoclopramide HCl and codeine phosphate as internal standards (IS), respectively. The methods, for both mixtures, were validated and met all the requirements for the quality control analysis recommended by FDA and ICH.

Development of Anticosmic Shielded Ultra Low Background Gamma Spectrometer for Precise Measurement of Environmental Radioactivity

  • Byun, Jong-In;Park, Yun-Ho;Kwak, Seung-Im;Hwang, Han-Yull;Chung, Kun-Ho;Park, Gun-Sik;Park, Doo-Won;Lee, Chnag-Woo
    • Nuclear Engineering and Technology
    • /
    • 제34권6호
    • /
    • pp.545-552
    • /
    • 2002
  • We developed an ultra low background gamma ray spectrometer particularly suitable for experiment which require lower detection limit. The background of a germanium spectrometer is suppressed by applying active and passive shielding technique at the same time. The active shielding devices consist of plastic scintillating plates of 50 mm thick and anti-coincidence electronic system. The shielding is made of 150 mm thick walls of very low activity lead,20 mm with activity of <10 Bq/kg and 130 mm with activity of <50 Bq/kg. The observed background count rates are 1.2 $s^{-1}$ and 0.36 $s^{-1}$ without and with the active shielding, respectively, overall the energy regions from 30 keV to 3 MeV The cosmic ray induced background is suppressed by a rate of 0.8 $s^{-1}$ at the present work. The detection efficiency curve necessary to obtain the radioactivity of environmental samples has been precisely determined on the energy regions from 80 to 2000 keV with a 10$^3$ ml marinelli beaker sample, consisting of the calibrated radionuclides $^{109}$ Cd, $^{57}$ CO, $^{139}$ Ce, $^{203}$ Hg, $^{113}$ Sn, $^{85}$Sr, $^{137}$ Cs, $^{60}$ Co and $^{88}$ Y. Virtues Of the method are demonstrated by measuring the activity of $^{137}$ Cs contained in the powdered milk.