• 제목/요약/키워드: active power filter function

검색결과 71건 처리시간 0.027초

직.병렬 능동 전력필터 시스템을 이용한 불평형 전원전압 보상 (The Compensating Unbalanced Source Voltages for Unified Active Power Filter System)

  • 김영석;강민형
    • 전기학회논문지
    • /
    • 제56권4호
    • /
    • pp.716-723
    • /
    • 2007
  • This paper suggests of a 3-phase 3-wire unified active power filter. The system is composed of a series active power filter and a parallel active power filter. The proposed series active power filter compensating unbalance source voltage and current harmonics of the parallel active power filter improves power factor. The proposed algorithm which improves for power factor and harmonic reduction are calculated by the performance function, and which compensates for the unbalanced source voltage is calculated based on the symmetrical component analysis. We composed a combined system of the series active power filter and parallel active power filter to confirm a validity of the proposed control methods. The effectiveness of the proposed algorithm is confirmed by the experiments.

성능함수제어 알고리즘을 이용한 3상 4선식 하이브리드형 직렬능동전력필터 (Hybrid Series Active Power filter Based on Performance Function Theory for 3-Phase 4-wire System)

  • 김진선;신재화;김영석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.1096-1098
    • /
    • 2003
  • In this paper, the control algorithm and control methods for a combined system of shunt passive filter and series active filter in 3-phase 4-wire system are discussed. Moreover, the 3-phase 4-wire system is widely employed in distributing electric energy to several office building and manufacturing plants. In such systems, the third harmonic and odd multiples of $3^{rd}$($9^{th}$, $15^{th}$, etc.) are termed as triple and zero sequence components that do not cancel each other in the system neutral. As a result, the triple harmonics add together creating a primary source of excessive neutral current. Regarding this concern, this paper presents a new control scheme for a series hybrid active system. This series active power filter acts not only as a harmonic compensator but also as a harmonic isolator. Hence the required rating of the series active filter is much smaller than that of a conventional shunt active filter. However, the performance of the combined system is greatly influenced by the filtering algorithm employed in the active power filter. This paper proposes a series active power filter scheme based on performance function. Some experiments was executed and experimental results from a prototype active power filter confirm the suitability of the proposed approach.

  • PDF

직접 보상전압 추출기법을 이용한 새로운 직렬형 능동전력필터 (A Novel Series Active Power Filter Using Direct Compensating Voltage Extraction Method)

  • 우원명;한윤석;김영석;원충연;최세완
    • 전력전자학회논문지
    • /
    • 제6권3호
    • /
    • pp.258-264
    • /
    • 2001
  • 본 논문에서는 직접 보상전압 추출기법을 이용한 새로운 직렬형 능동전력필터의 제어법을 제안한다. 제안된 직렬형 능동전력필터는 비선형 부하를 갖는 3상 3선식 전력계통에 병렬 수동필터와 함께 사용되어 병렬 수동필터의 단점을 보완하고, 전원측 고조파 저감 효과를 극대화시키는데 기여한다. 제안된 제어법은 직렬형 능동전력필터의 보상전압을 성능함수에 의해 상변환 없이 직접 추출할 수 있다. 따라서 기존의 방법에 비해 연산시간이 짧고, 제어가 보다 간단하다. 실험결과는 제안된 제어법을 이용한 시스템이 고조파 저감에 우수한 성능을 나타냄을 입증한다.

  • PDF

A Novel Photovoltaic Power Generation System including the Function of Shunt Active Filter

  • Park, Minwon;Seong, Nak-Gueon;Yu, In-Keun
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제3B권2호
    • /
    • pp.103-110
    • /
    • 2003
  • With significant development of power electronics technology, the proliferation of nonlinear loads such as static power converters has deteriorated power quality in power transmission and distribution systems. Notably, voltage harmonics resulting from current harmonics produced by the nonlinear loads have become a serious problem in many countries. Many photovoltaic power generation systems installed in building systems have harmonics that are the worst object for distribution systems as a utility interactive system, and it tends to spread out continuously. Proposed and implemented in this paper is a multi-function inverter control strategy that allows a shunt active filter function to the power inverter of the photovoltaic power generation system established on a building system. The effectiveness of the proposed system is demonstrated through the simulation of a hypothetical power system using PSCAD/EMTDC.

태양광발전시스템이 설치된 대전력 수용가의 Active Filter기능 적용의 필요성 (Application Necessity of the Active Filter Function to Photovoltaic Power Generation System installed in Building Systems)

  • 성낙권;박민원;유인근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.277-280
    • /
    • 2002
  • With significant development of power electronics technology, the proliferation of nonlinear loads such as static power converters has deteriorated power quality in power transmission and distribution systems. Notably, voltage harmonics resulting from current harmonics produced by the nonlinear loads have become a serious problem in many countries. There are already a lot of PV power generation systems installed in building systems whose harmonics are the worst object for distribution systems as a utility interactive system and also it tends to spread out continuously. In this paper, the authors propose a multy-function inverter control strategy which puts a shunt active filter function to the power inverter of the PV power generation system established on a building system. The effectiveness of the proposed system is demonstrated through the simulation of hypothetical power system using PSCAD/EMTDC.

  • PDF

Double Tuned Active Filter 기능을 갖는 Single Tuned Active Filter (Single-Tuned Active Filter with Function of Double-Tuned Active Filter)

  • 김찬기;양병모;정길조
    • 전력전자학회논문지
    • /
    • 제9권6호
    • /
    • pp.544-552
    • /
    • 2004
  • 본 논문은 Single Tuned Filter를 사용하여 11차와 13차 고조파를 동시에 제거하는 Hybrid 능동필터를 제안하였다. 제안된 Hybrid 능동필터는 Hybrid 능동필터의 Detuning 보상능력을 이용한 것으로, 하나의 필터를 이용하여 2개 이상의 고조파를 제거할 수 Topology를 보여주고 있다. 본 논문에서 다루는 Hybrid 능동필터는 Detuning 보상능력을 이용한 것이기 때문에 인버터 출력전압을 최적으로 설계하는 것이 필수적이다. 본 논문은 수동필터 부분의 커패시터 용량과 HVDC 시스템에서 발생되는 고조파 전류의 크기 그리고 수동필터의 공진주파수와 제어모드에 따라 인버터 출력전압이 변화함을 확인하였고, 이에 따른 최적의 인버터 전압을 구하였다.

성능함수를 이용한 직렬형 능동전력필터의 제어알고리즘에 관한 연구 (A Study of Control Algorithm For Series Active Power Filter Using Performance Function)

  • 고수현;김진선;김영석
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 추계학술대회 논문집
    • /
    • pp.199-202
    • /
    • 2002
  • This paper suggests the control algorithm of a 3-phase 3-wire series active power filters which have harmonic voltage source and harmonic current source This suggested control algorithm can compensate harmonics which are generated by nonlinear load such as diode or thyristor converter and reactive power in 3-phase 3-wire power distribution system This control algorithm extracts a compensation voltage reference from performance function without phase transformation Therefore this control algorithm is simpler than any other conventional control algorithm. 3-phase 3-wire series active power filter and hybrid active power filter is manufactured and experiments are carried out for harmonic voltage source and harmonic current source to verify the effectiveness of presented control algorithm Experimental results are presented in this Paper, as well.

  • PDF

능동전력필터 기능을 갖는 전기자동차용 10kW급 준급속 배터리 충전기 (The 10kW Rapid Battery Charger for Electric Vehicle with Active Power Filter Function)

  • 최성촌;송상훈;김도윤;김영렬;원충연
    • 조명전기설비학회논문지
    • /
    • 제28권5호
    • /
    • pp.122-133
    • /
    • 2014
  • This paper deals with the rapid charger which is the mid-type between the slow and fast chargers in the aspect of charging time. In its functions, it can perform the Active Power Filter(APF) function without changing the topology besides the charging function. In addition, to perform the charging and APF function, this paper proposes the mode selection algorithm. The operation of the charger that has APF function and the mode selection algorithm are verified by the simulation and experiment.

능동전력필터 기능을 갖는 다기능 준급속 충전기의 병렬운전 기법 (Parallel Operation Method of Multi Function Rapid-Charger with an Active Power Filter)

  • 배성훈;최성촌;신민호;송상훈;원충연
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2014년도 전력전자학술대회 논문집
    • /
    • pp.534-535
    • /
    • 2014
  • This paper proposes parallel operation of multi function rapid-charger with an active power filter. Rapid-charger can be installed in public institutions or mart parking lot. But conventional charger has disadvantage that it can not be used as the active power filter in charging mode with only one charger. So using 3-parallel operation, effective mode transfer between battery charging and APF function can obtain effect of harmonic compensation and improving the utilization of the charger.

  • PDF

고조파 전류와 무효전력보상을 위한 직렬형 능동전력필터 (A Series Active Power Filter For Harmonic Currents And Reactive Power Compensation)

  • 김진선;고수현;김영석
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권5호
    • /
    • pp.221-229
    • /
    • 2003
  • This paper suggests a control algorithm of 3-phase 3-wire series active power filter. This suggested algorithm can compensate source harmonics and reactive power in 3-phase 3-wire power distribution systems. These harmonics are generated by nonlinear loads such as diode rectifiers and thyristor converters. This control algorithm extracts a compensation voltage reference from performance function without phase transformation. Therefore, this control algorithm is simpler than any other conventional control algorithms. 3-phase 3-wire series active power filters which have a harmonic voltage source and a harmonic current source are manufactured and experiments are carried out to verify the effectiveness of suggested control algorithm.