• 제목/요약/키워드: active power filter

검색결과 580건 처리시간 0.022초

새로운 액티브 전압 클램프 ZVS-PWM 공진 고주파 인버터 (The New Active Voltage Clamp ZVS-PWM Resonant High-frequency Inverter)

  • 안용위;김홍신;문상필;우경일;박한석
    • 전기학회논문지P
    • /
    • 제66권4호
    • /
    • pp.188-193
    • /
    • 2017
  • In this paper, a ZVS-PWM high-frequency inverter with a PWM control function is applied to commercial system 220[Vrms], and a resonator type ZVS-PWM high-frequency inverter circuit with a fixed-two methods were proposed. The parameters of the transformer model equivalent circuit of a copier fixing device, which is an essential element in the parameter optimization of the proposed circuit, are obtained by using a high-frequency amplifier and its frequency characteristics are described. The proposed method compared to the existing single-ended ZVS-PFM high frequency inverter can suppress the voltage and current peak value of the power semiconductor switching device and reduce the switching loss. The efficiency of the proposed method itself is 98[%] at rated power output. Also, the efficiency of 96[%] can be obtained even at low output, so that the proposed high frequency inverter is very efficient inverter. The total efficiency from the commercial AC input to the inverter output is 93[%] at rated, which is considered efficient for use in copying machines. In addition, the diode bridge loss accounts for the largest portion of the overall system efficiency distribution. On the other hand, the nonparallel filter has a very low loss.

고조파발생에 따른 영향과 대책 연구 (Effect of Harmonic Generation and Countermeasures)

  • 백동현
    • 한국화재소방학회논문지
    • /
    • 제29권6호
    • /
    • pp.91-97
    • /
    • 2015
  • 초고층건축물이나 대형 사업장과 IT를 추구하는 수용가는 많은 가전기기 사용하여 선형, 비선형부하시의 고조파로인한 Capacitor의 과열 및 소손, 자료 손상, 대지전위 상승, 통신유도장해등을 일으켜 전력설비의 오동작과 과열로 화재의 원인이 될 수 있다. 이를 확인하기 위해 건축물의 7곳을 조사하여 비교한 결과 6곳에서는 적정하였으나 1곳은 고조파관리가 필요하였다. 전류 고조파는 No. 3, 6, 7은 매우 초과하여 정밀 진단이 필요하였으며 No. 2, 3, 5는 5고조파 전류를 고려하여야 한다. R상 전압고조파는 양호하였으나 전류고조파는 No. 1을 제외하고 No. 2, 3, 4, 5, 6, 7은 모두 기준을 초과하였다. 따라서 지그재그변압기나 엑티브필터를 설치하여 고조파 상승을 억제시킬 필요가 있고 설비불평형률, 역률등을 종합 조사하여 효율도 향상시킬 필요가 있다.

개선된 보조전원장치에 의한 고조파 저감대책 (Harmonic Reduction Scheme By the Advanced Auxiliary Voltage Supply)

  • 윤두오;윤경국;김성환
    • 해양환경안전학회지
    • /
    • 제21권6호
    • /
    • pp.759-769
    • /
    • 2015
  • 본 논문에서는 12펄스 정류기의 커패시터 중앙 DC버스에 개선된 보조전원장치를 설치하는 방법을 제안하였다. 11차 및 13차 고조파가 감소하는 이론적인 배경을 다루었으며 부하전류의 크기, 전원전압의 위상 및 크기, 커패시터 전압에 따라 개선된 보조전원의 파형 및 크기가 어떻게 제어되어야 하는지를 제시하였다. 기존의 구형파 보조전원장치를 적용한 경우는 전 영역에서 고조파 왜형률이 6~60[%]로 큰 편차를 보이지만 본 눈문에서 제안하는 개선된 보조전원장치를 적용한 경우 저 부하에서 고 부하에 이르는 전 영역에서 57~71[%] 라는 안정되고 뛰어난 고조파 왜형율 저감 효과를 보인다. 특히 10[%] 부하상태에서 기존방식은 고조파 왜형율 저감 효과가 6[%]로 효과가 거의 없지만 제안된 방식은 71[%]라는 놀라운 저감성능을 보여주고 있다. 소프트웨어 PSIM을 활용하여 컴퓨터 시뮬레이션을 통해 제안된 방식의 유효성을 입증하였다.

Reg. Guide 1.52(Rev.3)를 적용한 원전 ESF 공기정화계통 성능시험법 개선 연구 (A Study on Improvement of Test Method of Nuclear Power Plant ESF ACS by applying Regulatory Guide 1.52 (Rev.3))

  • 이숙경;김광신;손순환;송규민;이계우;박정서;조병호;유병재;홍순준;강선행
    • 방사성폐기물학회지
    • /
    • 제8권4호
    • /
    • pp.311-318
    • /
    • 2010
  • 공학적 안전설비 공기정화계통의 규제지침인 Reg. Guide 1.52(Rev.3)의 변경사항중 성능시험과 관련한 운전가능성 시험시간 단축, HEPA 필터 현장누설시험용 시험물질 변경 및 활성탄 성능시험 Methyl Iodidie 투과허용율 상향 변경을 영광 5,6호기에 적용하고자, 모사실험장치와 현장 설비를 활용하여 기술적 타당성을 확인하는 실험을 수행하였다. 10시간 이상의 장시간 운전가능성 시험을 통해 계통내 습분을 제거하여도 시험후 1~4일만에 회복됨을 확인하여 운전가능성 시험은 기기적 운전가능성 점검에 적합한 매월 15분 이상의 시험을 수행하는 것이 타당함을 확인하였다. HEPA 필터 현장누설시험용 시험물질 변경을 위해 DOP와 PAO의 에어로졸 입자크기, 발생량, 누설인지도를 비교한 결과 PAO는 원전에서도 DOP 대체시험물질로 사용 가능함을 확인하였다. 베드깊이 4 인치 이상의 활성탄여과기에 대한 Methyl Iodide의 투과율 허용치가 0.175 %에서 0.5 %로 상향 변경된 것은, ASTM D3803(1989)으로의 활성탄 성능시험 방법 변경에 따른 것으로서, $30^{\circ}C$ 상대습도 95 %에서의 Methyl Iodide 투과허용율 0.5 %가 사용 중 활성탄의 성능을 시험하기에 충분히 보수적인 시험방법임을 확인하였다. 본 실험 결과를 바탕으로 영광 5,6호기는 인허가변경을 완료하였다.

원자력등급 ESF 공기정화계통 시뮬레이터 제작 및 활용에 관한 연구 (A Study on Construction and Application of Nuclear Grade ESF ACS Simulator)

  • 이숙경;김광신;손순환;송규민;이계우;박정서;홍순준;강선행
    • 방사성폐기물학회지
    • /
    • 제8권4호
    • /
    • pp.319-327
    • /
    • 2010
  • 공학적 안전설비 공기정화계통과 관련된 실험 수행을 위해 원자력등급 ESF 공기정화계통 시뮬레이터를 설계, 제작, 검증하였다. 영광 5,6호기 주제어실 공기정화계통의 공급자 정보, 도면 등을 기준으로 실사를 통해 치수를 확인하여 3D CAD 모델을 작성하였다. 모델과 현장 계통의 실측 유량을 기준으로 CFD 분석을 수행하였다. 공기정화계통으로 유입되는 공기는 $30^{\circ}C$, 유동형태는 균일한 것으로 가정하고, 검사 기록지에 의한 주제어실 ESF 공기정화계통의 유량이 12,986 CFM이고, $610{\times}610mm^2$의 HEPA 필터가 9개 설치되어 있으므로 HEPA 필터 단면를 지나는 유속은 1.83 m/s이다. 주제어실 공기정화계통 모델링시 공기 유동이 흐르지 않는 필터 테두리 지지대를 고려하여 현장과 유사한 유동현상을 모사하였다. 약 8 m/s로 기록된 활성탄 흡착기 하단의 공기유동은 별도의 분석을 통해 7 m/s 이상의 유속이 모사되도록 CFD 분석하였다. 연료건물 비상배기계통 및 비상노심냉각계통 기기실 배기정화계통의 공기정화계통에 대해서도 CFD 분석한 결과, 시뮬레이터의 유속을 조절하면 세가지 ESF 공기정화계통을 모두 모사할 수 있음을 확인하였다. CFD 분석 후 시뮬레이터를 원자력등급으로 제작하였고, 본 실험에 착수하기 전에 공기유동 분포도실험을 통해 시뮬레이터의 신뢰도를 검증하였다. 검증결과 중급 필터를 장착한 상태에서 시뮬레이터의 필터 지지대 부분을 제외한 내부에서 공기유동이 고르게 분포함을 확인하였고, 제작된 시뮬레이터는 Reg. Guide 1.52(Rev.3) 개정 내용 확인을 위한 실험에 사용되었다.

A Dual-Mode 2.4-GHz CMOS Transceiver for High-Rate Bluetooth Systems

  • Hyun, Seok-Bong;Tak, Geum-Young;Kim, Sun-Hee;Kim, Byung-Jo;Ko, Jin-Ho;Park, Seong-Su
    • ETRI Journal
    • /
    • 제26권3호
    • /
    • pp.229-240
    • /
    • 2004
  • This paper reports on our development of a dual-mode transceiver for a CMOS high-rate Bluetooth system-onchip solution. The transceiver includes most of the radio building blocks such as an active complex filter, a Gaussian frequency shift keying (GFSK) demodulator, a variable gain amplifier (VGA), a dc offset cancellation circuit, a quadrature local oscillator (LO) generator, and an RF front-end. It is designed for both the normal-rate Bluetooth with an instantaneous bit rate of 1 Mb/s and the high-rate Bluetooth of up to 12 Mb/s. The receiver employs a dualconversion combined with a baseband dual-path architecture for resolving many problems such as flicker noise, dc offset, and power consumption of the dual-mode system. The transceiver requires none of the external image-rejection and intermediate frequency (IF) channel filters by using an LO of 1.6 GHz and the fifth order onchip filters. The chip is fabricated on a $6.5-mm^{2}$ die using a standard $0.25-{\mu}m$ CMOS technology. Experimental results show an in-band image-rejection ratio of 40 dB, an IIP3 of -5 dBm, and a sensitivity of -77 dBm for the Bluetooth mode when the losses from the external components are compensated. It consumes 42 mA in receive ${\pi}/4-diffrential$ quadrature phase-shift keying $({\pi}/4-DQPSK)$ mode of 8 Mb/s, 35 mA in receive GFSK mode of 1 Mb/s, and 32 mA in transmit mode from a 2.5-V supply. These results indicate that the architecture and circuits are adaptable to the implementation of a low-cost, multi-mode, high-speed wireless personal area network.

  • PDF

임피던스 직접 정합 방법에 의한 Rectenna 시스템 소형화 설계 (Compact Rectenna System Design Using a Direct Impedance Matching Method)

  • 최태민;한상민
    • 한국전자파학회논문지
    • /
    • 제24권3호
    • /
    • pp.286-291
    • /
    • 2013
  • 본 논문에서는 고조파 공진 억제 특성을 갖는 원형 섹터 안테나와 임피던스 직접 정합 방법을 이용하여 소형화된 rectenna 시스템을 설계하였다. 원형 섹터 안테나의 고조파 억제 특성을 이용하여 정류 회로의 대역 통과 여파기 기능을 수행하였으며, 임피던스 직접 정합 방법에 의해 다이오드 정합 회로를 생략하는 설계가 이루어졌다. 따라서 제안된 시스템의 정류 회로는 대역 통과 여파기와 정합 회로 없이 구현되었으며, 정밀한 동축 급전 공정을 사용하여 시스템의 성능 열화 없이 급전 위치를 변화하며, 안테나 뒷면에 집적하였다. 최적의 정합 특성으로 2.5 GHz 대역에서 설계된 rectenna 시스템은 실험 결과, 52 % 이상의 변환 효율과 1.5 V 이상의 우수한 변환 전압 특성을 나타내었다.

INMARSAT-B형 위성통신용 광대역 수신단 구현 및 성능평가에 관한 연구 (A Study on Implementation and Performance Evaluation of Wideband Receiver for the INMARSAT-B Satellite Communications System)

  • 전중성;임종근;김동일;김기문
    • 한국정보통신학회논문지
    • /
    • 제5권1호
    • /
    • pp.166-172
    • /
    • 2001
  • 본 논문에서는 INMARSAT-B형 위성통신용 광대역 수신단을 저잡음증폭기와 고이득증폭기로 구성하였다. 저잡음증폭기의 입력단 정합회로는 저항 결합회로의 형태로 설계하였으며, 전원회로는 저잡음 특성이 우수한 자기 바이어스 회로를 사용하였다. 수신단 이득을 향상시키기 위해서 고이득증폭기는 양단 정합된 단일 증폭기 형태로 제작하였으며, 바이어스 안정화 저항을 사용하여 회로의 전압강하 및 전력손실을 가능한 줄이고 온도 안정성을 고려하여 능동 바이어스 회로를 사용하였으며, 스퓨리어스를 감쇠시키기 위해서 저잡음증폭기와 고이득증폭기사이에 대역통과 필터를 사용하였다. 1525~1575 MHz 대역에서 60 dB 이상의 이득, 1.8:1 이하의 입.출력 정재파비를 나타내었으며, 특히 1537.5 MHz에서 입력신호의 크기가 -126.7 dBm일 때1.02 kHz 떨어진 점에서의 C/N비가 45.23 dB/hz의 측정결과를 나타냄으로써 설계시 목표로 했던 사양을 모두 만족시켰다.

  • PDF

복수정현파 소음제거를 위한 Filtered-x LMS 알고리듬의 수렴 특성에 관한 연구 (Convergence of the Filtered-x LMS Algorithm for Canceling Multiple Sinusoidal Acoustic Noise)

  • 이강승;이재천;윤대희;강영석
    • 한국음향학회지
    • /
    • 제14권2호
    • /
    • pp.40-49
    • /
    • 1995
  • Filtered-x 최소 평균 제곱(LMS:Least Mean Square) 적응 필터가 능동 소음 제거에 사용될 때 적응 필터 출력과 오차신호 사이의 전달 특성 추정이 요구된다. 본 논문은 소음이 복구 정현파(multiple sinusoids) 신호로 구성될 때 filtered-x 적응 소음 제거 알고리듬을 유도하고 수렴 특성을 이론적으로 분석하였다. 알고리듬의 수렴 분석 결과, 알고리듬에 사용되 파라미터 추정의 부정확성으로 수렴 성능 저하를 가져오는데 위상 추정 오차와 추정 이득에 의하여 특정 지워진다는 사실을 알았다. 특히, filtered-x 최소 평균 제곱 알고리듬의 수렴은 위상 응답 추정의 정확도로부터 많은 영향을 받는다는 것을 보였다. 이 알고리듬에 대한 컴퓨터 모의 실험 결과 이론적인 수렴 분석과 잘 일치함을 보였다.

  • PDF

연성 인쇄 회로 기판을 이용한 초고주파 MEMS 송신기 연구 (A RF MEMS Transmitter Based on Flexible Printed Circuit Boards)

  • 명성식;김선일;정주용;육종관
    • 한국전자파학회논문지
    • /
    • 제19권1호
    • /
    • pp.61-70
    • /
    • 2008
  • 본 논문에서는 멤스 기술의 하나인 연성 인쇄 회로 기판을 이용하여 임의의 형태로 변형이 가능한 초고주파 멤스 송신기를 제안하였다. 연성 인쇄 회로 기판은 그 무게가 가볍고 두께가 얇아 경량 소형화 모듈을 만드는데 유리한 장점이 있다. 또한, 연성 인쇄 회로 기판은 종이와 같이 유연한 특성을 가지고 있어 평면이 아닌 임의의 곡면 등에 실장할 수 있는 장정을 가지고 있다. 본 논문에서는 근거리 센서 네트워크 구성을 위한 직교 주파수 분할 다중 전송 방식을 위한 선형 무선 송신기를 설계 제작하였다. 송신 모듈의 능동 회로는 전력효율이 높고 선형성이 우수하여 전력 증폭기에 많이 사용되고 있는 InGaP/GaAs HBT 공정을 사용하여 설계 및 제작하였으며, 매칭 회로 및 필터 등의 수동 회로는 연성 인쇄 회로 기판에 직접 집적화 하여 제작하였다. 제작된 멤스 송신기는 EVM 특성을 통하여 시스템 성능을 분석하였다.