• Title/Summary/Keyword: active operation

Search Result 1,484, Processing Time 0.029 seconds

Practical Design Methodology of Dual Active Bridge Converter as Isolated Bi-directional DC-DC Converter for Solid State Transformer (Solid State Transformer를 위한 양방향 Dual Active Bridge DC-DC 컨버터의 설계 기법)

  • Choi, Hyun-Jun;Lee, Won-Bin;Jung, Jee-Hoon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.2
    • /
    • pp.102-108
    • /
    • 2017
  • Proper design guides are proposed for a practical dual-active bridge (DAB) converter based on the mathematical model on the steady state. The DAB converter is popular in bidirectional application due to its zero-voltage capability and easy bidirectional operation for seamless control, high efficiency, and performance. Some design considerations are taken to overcome the limitation of the DAB converter. The practical design methodology of power stage is discussed to minimize the conduction and switching losses of the DAB converter. Small-signal model and frequency response are derived and analyzed based on the generalized average method, which considers equivalent series resistance, to improve the dynamics, stability, and reliability with voltage regulation of the practical DAB converter. The design of closed-loop control is discussed by the derived small-signal model to obtain the pertinent gain and phase margin in steady-state operation. Experimental results of a 3.3 kW prototype of DAB converter demonstrate the validity and effectiveness of the proposed methods.

Wide Input Range Active Clamp Forward Converter Design (넓은 입력전압 능동 클램프 포워드 컨버터 설계)

  • Chun, Moon-Il;Kim, Chang-Sun;Ma, Byung-In
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.64-65
    • /
    • 2008
  • The topology of active clamp forward converter provides ZVS characteristic and also the stress of voltage and current is smaller than that of the conventional forward converters. The benefits of this technique include a higher efficiency at a high switching frequency, lower EMI/RFI. In this paper, the active clamp forward converter is designed for operation in wide range voltage and has 19.5V/120W ratings with efficiency more than 90%.

  • PDF

Characteristics of Boost Input Type Active Clamp Forward ZVS Converter (Boost 입력형 능동클램프 Forward ZVS Converter)

  • Oh Yong-Seung;Kim Hee-Jun
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.386-389
    • /
    • 2002
  • This paper proposes the boost input type active clamp forward ZVS(zero voltage switching) DC-DC converter which can provide high efficiency and improved EMI characteristics. Moreover, it has active clamp circuit for reducing the voltage stress and zero voltage switching technique for minimizing switching loss. The detailed operation principles and the simulation results are presented.

  • PDF

Large-Signal Transient Analysis of a Self-Driven Active-Clamp Forward Converter (자기 구동 능동 클램프 포워드 컨버터의 대신호 과도 특성 해석)

  • Bong Sang-Cheol;Kim Hee-Jun
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1235-1238
    • /
    • 2004
  • This paper presents the large-signal transient analysis of a self-driven active-clamp forward converter, eliminating the extra drive circuit for the active clamp switch. The operation principle of the converter was presented and experiential results were used to verify the analyzed results. A 50-W prototype converter built and tested it. From the tested results, input transient response and load transient response of the converter were established.

  • PDF

A New Controllable Active Clamp Algorithm for Switching Loss Reduction in a Module Integrated Converter System

  • Park, Chang-Seok;Jung, Tae-Uk
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.3 no.4
    • /
    • pp.465-471
    • /
    • 2014
  • This paper proposes a new switching algorithm for an active clamp snubber to improve the efficiency of a module integrated converter system. This system uses an active clamp method for the snubber circuit for the efficiency and reliability of the system. However, the active clamp snubber circuit has the disadvantage that system efficiency is decreased by switch operating time because of heat loss in resonance between the snubber capacitor and leakage inductance. To address this, this paper proposes a new switching algorithm. The proposed algorithm is a technique to reduce power consumption by reducing the resonance of the snubber switch operation time. Also, the snubber switch is operated at zero voltage switching by turning on the snubber switch before main switch turn-off. Simulation and experimental results are presented to show the validity of the proposed new active clamp control algorithm.

A study of an Active Stick Controlling System with Friction Observer (Active Stick 제어기 개발에 관한 연구)

  • Kim, Myung-Yul;Nam, Yoon-su
    • Journal of Industrial Technology
    • /
    • v.24 no.B
    • /
    • pp.207-214
    • /
    • 2004
  • An active stick which supplies force feedback to the operator is developed in this study. A mathematical model of the active stick is derived, and compared with the experimental result. It turns out that the frictional torque due to the mechanical contacts of several parts of the stick is one of the major barriers to achieve high precision operation of the stick. The frictional effect of the stick is cancelled out by using a friction observer. The efficacy of the friction observer is verified through the numerical simulation. Because of the observer dynamics, there are some limitations in exact recovering the static friction and Stribeck effect. However, the friction observer follows the real friction on the average. It's anticipated that the application of the friction observer to the closed loop control of the active stick improves the performance of the displacement versus force characteristics, which will be proved experimentally in the further study.

  • PDF

Design of Semi-Active suspension system for Railway Vehicle with narrow gauge (협궤 차량용 준능동형 현가 시스템 설계)

  • Lee Nam-Jin;Kim Chul-Gun;Nam Hak-Gi
    • Proceedings of the KSR Conference
    • /
    • 2005.05a
    • /
    • pp.473-478
    • /
    • 2005
  • Active suspension system improves ride quality with optimized suspension force, generated by electric, hydrolic or pneumatic power and controlled by micro-processor under various operation condition of train, while Semi-Active susepsion system provides optimized and controlled characteristics of suspensions such as damping coefficient without external energy. The benefits fo Semi-Active suspension are no required power source and to be made compact with lower cost. Train with narrow gauge could be more unstable than one for normal or wide gauge, and it could be more vibrated than others one by external force such as aerodynamic force and track irregularity. So, the reduced ride quality could be improved with appling with Semi-active suspension system. In this report, the Semi-Active suspension system for narrow gauge train shall be proposed and to prepare the Roller Rig test of this train, integration of system, development of control algorithm and confirmation of its performance with simulation tool would be taken.

  • PDF

A Three-Phase Parallel Active Power Filter Operating with PCC Voltage Compensation by Controlling Reactive Power (무효전력 제어에 의한 PCC전압 보상을 갖는 삼상 병렬형 능동전력필터)

  • Lee, U-Cheol;Hyeon, Dong-Seok;Lee, Taek-Gi
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.3
    • /
    • pp.211-218
    • /
    • 2000
  • The performance and dynamic characteristics of three-phase active power filter with PCC voltage compensation is presented and analyzed in this paper. The characteristics of parallel active filter are discussed when they are applied to nonlinear loads with current source and voltage source type, the characteristics of voltage compensator and comparison of two functions are discussed. The proposed scheme in this paper employs a PWM voltage-source inverter and has two operation modes. First, it operates as a conventional active filter with reactive power compensation while PCC voltage is in a certain range. Second, is operates as a voltage compensator while PCC voltage is out of range. Finally, the validity of this scheme is investigated through analysis of simulation and experimental results for a prototype active power filter system rated at 10KVA.

  • PDF

A Study on the Optimum Operational Control of Power System (전렬계통의 합리적 운용제어에 관한 연구)

  • 정재길;박영문
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.33 no.10
    • /
    • pp.410-422
    • /
    • 1984
  • This paper presents a new practical method for optimal active and reactive power control for the economic operation in electrical power system, and the programs are developed for digital computer solution. The major features and techniques of this paper are as follows: 1) The method is presented for finding the equivalent active power balance equation applying the sparse Jacobian matrix of power flow equation instead of using B constant as active power balance equation considering transmission loss, and thus for determining directly optimal active power allocation berween generator unitw satisfying the equality and inequality constraints. 2) The method is proposed for solving directly the optimum economim dispatch problem without using gradient method and penalty function for both active and reactive power control. As a result, the computing time are reduced and convergence characteristic is remarkably improved. 3) Unlike most of conventional methods which adopt the transmission loss as a objective function for reactive power control, the total fuel cost of themal power plant is adopted as objective function for both active and reactive power control. consequently, more reasonable and economic profit can be achieved.

A Study on a Boost-Input Self-Driven Active Clamp ZVS Converter (자기구동 능동 클램프를 이용한 부스트 입력형 ZVS 컨버터에 관한 연구)

  • Jin, Ho-Sang;Kim, Hee-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.4
    • /
    • pp.781-788
    • /
    • 2011
  • This paper proposes a boost-input self-driven active clamp ZVS converter eliminating the extra dirve circuit for the active clamp switch. The converter used the auxiliary winding of the transformer to drive the active clamp switch and to achieve asymmetrical duty control. This paper presents the operation principle and the analyzed results of dynamic characteristics including steady state characteristics of the converter proposed. The experimental results were used to verify the theoretical predictions. A 300W (15V/20A) prototype converter that only exhibited 2-turn winding number in the auxiliary winding was sufficient to drive the active clamp switch on the input voltage of 80V. Finally, the maximum efficiency of 91.2% was achieved for the prototype converter and the proposed converter had stable closed loop characteristic with phase margin $55^{\circ}$.