• 제목/요약/키워드: active operation

검색결과 1,484건 처리시간 0.026초

균일 혼합기를 이용한 이론 공연비 직접분사 가솔린 엔진 개발에 관한 실험적 연구 (A Study on the Development of Stoichiometric Direct Injection Gasoline Engine by Homogeneous Charge)

  • 이내현;유철호;최규훈
    • 한국자동차공학회논문집
    • /
    • 제6권2호
    • /
    • pp.32-42
    • /
    • 1998
  • Lean burn gasoline engine is recognized as a promising way to meet better fuel economy. Lean burn engine is classified into port injection and direct injection(DI), DI is more active technique for improving fuel economy with ultra-lean operation, Nowadays, port injected lean burn engine has been produced by many Japan maker. Also, DI engine is also possible for production owing to improvement in control technique of spray, flow air fuel ratio. DI engine uses either homogeneous stoichiometric mixture or stratified mixture by controlling injection timing to be early or late respectively. HM(homogeneous mixture) is worse than SM(stratified mixture) in view of ultra-lean operation in partical load and Nox reducion by using EGR control. But, HM has advanteges in cold starting and emission reduction during transient operation, This paper describes experimental variables and bench test results of HM GDI engine.

  • PDF

풍력발전 계통연계 평가기준 연구 (Study of Power System Impact Assessment Standard for Large-scale Wind Farms)

  • 최영도;전영수;박영신;전동훈;윤기갑;박상호;신정훈;이재걸
    • 신재생에너지
    • /
    • 제6권1호
    • /
    • pp.12-19
    • /
    • 2010
  • In Korea, experiences in wind farm operation are limited and the foundation for setting standards in electrical system connection is still weak in comparison to the operation experience in connection of wind power to the electrical system of other countries around the world. Therefore, standards that are being applied in various countries for connection and optimal operation in wind farms need to be examined, and in addition, procedures for the assessment of the effects on the system are needed for setting connection standards and optimal operation plans in accordance with Korean electrical system characteristics. In this study, procedures for the assessment of effects of wind power connection to the electrical system are presented.

동력 분기 하이브리드 전기 자동차의 운행 모드 시뮬레이션 (Operation Modes of a Power Split Hybrid Electric Vehicle)

  • 안국현;조성태;임원식;박영일;이장무
    • 신재생에너지
    • /
    • 제2권2호
    • /
    • pp.23-27
    • /
    • 2006
  • The power split hybrid powertrain is considered to be one of the most prospective configuration for the hybrid electric vehicle (HEV). Toyota Prius, representing this type of vehicle, showed outstanding performances in fuel efficiency, emission reduction and acceleration. The excellence is largely due to the fact that it utilizes almost all operation modes of HEV. Those modes include ZEV (Zero Emission Vehicle) driving, idle stop, fuel cut-off, power assist, active charging, regenerative braking and so forth. In this paper, a few of the mode operations were simulated using AVL Cruise. Also, control logics to operate the powertrain in each mode were developed. The states of powertrain components were displayed and analyzed. By controlling the three components (engine, motor and generator), it was possible to run the powertrain in several hybrid operation modes.

  • PDF

활동기 자가판 심내막염의 판막치환술: 7례 경험 (Early Valve Replacement in Patient with Native Valve Endocarditis - Report of Seven Cases -)

  • 허동명
    • Journal of Chest Surgery
    • /
    • 제24권10호
    • /
    • pp.979-986
    • /
    • 1991
  • From October 1988 to November 1989, seven patients underwent valve replacement during the active phase of native valve endocarditis. There were 4 males and 3 females whose mean age was 41 years[range, 16 to 68 years]. Preoperative two-dimensional and Doppler echocardiography showed vegetations and severe valvular regurgitation in all patients. Blood cultures were positive in 4, and negative in 3 patients Organisms were alpha-hemolytic Streptococcus in 2, Staphylococcus epidermidis in 1, Erysipelothrix rhusiopathiae in 1 patient Valve tissue cultures were negative in all patients. Intravenous antibiotic therapy had been done for 3 to 18 days in 5 patients pre-operatively and was not done in 2 patients, Indications for operation were heart failure in h, and systemic emboli in 1 patient. The aortic valve was involved in 3, mitral in 1, and both aortic and mitral in 3 patients, One operative death[14.4%] occurred in patient with cardiogenic shock before operation. Late death occurred in one on 14 months after operation. The remaining 5 patients were followed up over a two year period in good condition. In conclusion, native valve endocarditis with severe heart failure must be considered for early operation.

  • PDF

Control Strategy against Undesirable Zone 3 Relay Operation in Voltage Instability

  • Lee Byong-Jun;Song Hwa-Chang
    • KIEE International Transactions on Power Engineering
    • /
    • 제5A권2호
    • /
    • pp.144-151
    • /
    • 2005
  • This paper presents a framework for determining control strategies against unwanted tripping actions during relay operation that plays a very important role in cascading events leading to voltage collapse. The framework includes an algorithm for quick identification of possible zone 3 relay operation during voltage instability. Furthermore, it comes up with the control strategy of load shedding at the selected location with active power and relay margin criteria. In addition, Quasi Steady-State (QSS) simulation is employed to obtain time-related information that is valuable in the determination of control strategy. As a case study, an example applying the framework is shown with the modified New England 39-bus system.

동력 분기 하이브리드 전기 자동차의 운행 모드 시뮬레이션 (Operation Modes of a Power Split Hybrid Electric Vehicle)

  • 안국현;조성태;임원식;박영일;이장무
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 춘계학술대회
    • /
    • pp.547-550
    • /
    • 2006
  • The power split hybrid power train is considered to be one of the most prospective configuration for the hybrid electric vehicle (HEV). Toyota Prius, representing this type of vehicle, showed outstanding performances in fuel efficiency, emission reduction and acceleration. The excellence is largely due to the fact that it utilizes almost all operation modes of HEV. Those modes include ZEV (Zero Emission Vehicle) driving, idle stop, fuel cut-off, power assist, active charging, regenerative braking and so forth. In this paper, a few of the mode operations were simulated using AVL Cruise. Also, control logics to operate the powertrain in each mode were developed. The states of powertrain components were displayed and analyzed. By controlling the three components (engine, motor and generator), it was possible to run the powertrain in several hybrid operation modes.

  • PDF

영국 화물철도운영자(EWS)와 코레일(한국철도공사) 교번근무제도 비교연구 (Comparison study for train crews and pilots operation system between EWS of UK and KORAIL of Korea)

  • 채일권;황선경;박찬홍;전영석
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집
    • /
    • pp.1871-1877
    • /
    • 2009
  • KORAIL has been established by 1st January 2005. From organization change to KORAIL(Korea railroad Corporation), labour union and company management team has been argument for their train crews and drivers operation system. For example, train crew and driver working conditions; working hours per week, off day and duty day time, over night time working payment, current position payment, preparation time, company own lodge operation and so on. I assure that this comparison study for train crew and driver operation between KORAIL and EWS will helps to improve other korean railway companies management efficiency. In conclusion, EWS has 4$\sim$6 times more efficient employee for active operation than KORAIL per 1 freight brock-train operation. EWS has very resonable train crews and driver operation system, and self-control regulation for employee and management team with trusty. This thesis propose that korean railway companies and their own labour unions need joint research and benchmarking other oversea railway companies as like EWS.

  • PDF

새로운 액티브 스너버 셀을 적용한 ZVT PWM DC-DC 컨버터 (Zero-Voltage-Transition PWM DC-DC Converter Using A New Active-Snubber-Cell)

  • 하이 뜨란;아디스티라;김선주;최세완
    • 전력전자학회논문지
    • /
    • 제23권4호
    • /
    • pp.273-280
    • /
    • 2018
  • This paper proposes a zero-voltage-transition pulse-width modulation (PWM) DC-DC converter that uses a new active-snubber-cell. The converter main switch can be turned on and off with ZVS, while the snubber switch is turned on with ZCS and turned off with ZVS. Other semiconductor devices are operated under the soft-switching condition. Normal PWM control can be used, the proposed active-snubber-cell does not impose any additional voltage and current stresses. The active-snubber-cell is suitable for high-power applications due to its easy integration into interleaved converters. This paper discusses the operation of the converter, presents some design guidelines, and provides the results of an experiment with a 100 kHz and 1 kW prototype. A peak efficiency of 97.8% is recorded.

전류 고조파와 불평형 전원 전압을 보상하는 직렬형 능동전력 필터와 병렬형 수동전력필터 병용시스템의 새로운 제어법 (A Novel Control Method of Combined System consists of Series Active Power Filter and Parallel Passive Power Filter to Compensate Current Harmonics and Unbalanced Source Voltages)

  • 오재훈;한윤석;김영석;원충연;최세완
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제50권12호
    • /
    • pp.615-623
    • /
    • 2001
  • In this paper, we study a series active power filter to compensate current harmonics and unbalanced source voltages. Conventional control methods for compensating unbalanced source voltages use source voltages to calculate compensation voltages, and in addition use load voltages to regulate load voltages. But the proposed control method uses load voltage to compensate unbalanced source voltages and regulate load voltages. And we propose a control method to reduce current harmonics which can calculate compensation voltages directly from source currents and load voltages. By well-matched operation of two control methods, the series active power filter can compensate current harmonics, unbalanced source voltages, and regulate load voltages. We compose a combined system of the series active power filter and parallel passive filters to confirm a validity of proposed control methods. The results from experiments are presented to demonstrate effectiveness of the proposed method.

  • PDF

무부하 압축기에 의한 냉장고 기계실 소음의 능동제어 (Active Control of Noise Transmitted through Ventilation Openings of the Machinery Room of Refrigerator)

  • 구정모;정의봉;김태훈;홍진숙
    • 한국소음진동공학회논문집
    • /
    • 제26권4호
    • /
    • pp.475-482
    • /
    • 2016
  • The active control of noise generated by the compressor and transmitted out of the machine room through the windows is implemented based on the FIR filter. The machine room contains most of noise sources of electric home appliances, air-conditioners and refrigerators, for example. To actively reduce the noise from the machinery room. In this paper, the transfer function of the controller for minimization of the acoustic power transmitted through the windows is mathematically formulated. The transfer functions required for implementation of the active controller are the measured. The measurements are conducted in this initial stage under the operation of the compressor with no load. For improvement of the reliability of the transfer function of the compressor to the acoustic power, additional operational measurements are performed. The real time controller is implemented based on the FIR filter using the measured transfer functions and the performance of the active controller is estimated. Control performance is measured about 3 dB ~ 10 dB in reduction of the sound power at the peaks of the compressor noise.