• Title/Summary/Keyword: active noise barrier

Search Result 24, Processing Time 0.023 seconds

Visualization and classification of hidden defects in triplex composites used in LNG carriers by active thermography

  • Hwang, Soonkyu;Jeon, Ikgeun;Han, Gayoung;Sohn, Hoon;Yun, Wonjun
    • Smart Structures and Systems
    • /
    • v.24 no.6
    • /
    • pp.803-812
    • /
    • 2019
  • Triplex composite is an epoxy-bonded joint structure, which constitutes the secondary barrier in a liquefied natural gas (LNG) carrier. Defects in the triplex composite weaken its shear strength and may cause leakage of the LNG, thus compromising the structural integrity of the LNG carrier. This paper proposes an autonomous triplex composite inspection (ATCI) system for visualizing and classifying hidden defects in the triplex composite installed inside an LNG carrier. First, heat energy is generated on the surface of the triplex composite using halogen lamps, and the corresponding heat response is measured by an infrared (IR) camera. Next, the region of interest (ROI) is traced and noise components are removed to minimize false indications of defects. After a defect is identified, it is classified as internal void or uncured adhesive and its size and shape are quantified and visualized, respectively. The proposed ATCI system allows the fully automated and contactless detection, classification, and quantification of hidden defects inside the triplex composite. The effectiveness of the proposed ATCI system is validated using the data obtained from actual triplex composite installed in an LNG carrier membrane system.

Improved performance of PEDOT:PSS/pentacene Schottky diode on EAPap (셀룰로우스 기반의 EAPap 작동기의 PEDOT_PSS/Pentacene를 이용한 Schottky diode 성능 개선)

  • Lim, Hyun-Kyu;Cho, Ki-Youn;Kang, Kwang-Sun;Kim, Jae-Hwan
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.77-81
    • /
    • 2007
  • Pentacene was dissolved in N-methyspyrrolidone (NMP) and mixed with poly(3,4-ethylenedioxythiophene), poly(styrenesulfonate) (PEDOT:PSS). The solution color changed from deep purple to intense yellow. As the dissolution time increased, visible absorption decreased and ultraviolet (UV) absorption increased. PEDOT:PSS or Pentacene-PEDOT:PSS was spin-coated to control the layer thickness. Three-layered Schottky diodes consisting of Al, PEDOT:PSS or PEDOT:PSS-pentacene, and Au with thickness of 300nm, respectively, were fabricated. The current densities of $4.8{\mu}A/cm^2$ at 2.5MV/m and $660{\mu}A/cm^2$ at 1.9MV/m were obtained for the Au/PEDOT:PSS/Al and Au/Pentacene-PEDOT:PSS/Al Schottky diodes, respectively. The current density of the Schottky diode was enhanced by about two orders of magnitude by doping pentacene to PEDOT:PSS.

  • PDF

A Study of Sound Pressure Characteristics of Error Sensors by Position in Active Noise Barrier Development (능동형 방음벽 개발을 위한 에러센서 위치 연구)

  • Cha, Sang-Gon;Kim, Dong-Hwan;Troshinun, Andrey;Choi, Jang-Cheol;Shin, Eun-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1756-1757
    • /
    • 2011
  • 본 논문에서는 FXLMS 알고리즘을 이용하여 3차원 폐공간(반무향실)에서의 순음(125Hz)을 이용하여 부 음원과 에러센서의 위치 변화에 따른 소음저감 정도를 분석하였으며, 이 결과를 바탕으로 능동형 방음벽의 구현의 기초자료로 활용하고자 하였다. 부음원(제어스피커, 이하 부음원)과 에러센서간 거리차는 0.5m, 1.5m, 2.5m를 대상으로 실험을 실시하였으며 그 중 거리차가 1.5m 지점의 경우, 125Hz부근에서는 최대 18.3dB, Overall(80Hz~200Hz)값은 18.2dB(A)의 소음저감 효과가 있는 것으로 나타나, 가장 효과적인 부음원과 에러센서간의 거리차인 것으로 평가되었다.

  • PDF

Explanation of Foaming Mechanism and Experimental Application of Foam Reduction Techniques in the Treated Wastewater Outlet of Wastewater Treatment Plant Connected to a Tidal River, Korea (감조하천에 연결된 하수처리장 방류구의 거품 형성기작 해석 및 거품발생 저감기술의 실험적 현장적용)

  • Shin, Jae-Ki;Cho, Youngsoo;Kim, Youngsung;Kang, Bok-Gyoo;Hwang, Soon-Jin
    • Korean Journal of Ecology and Environment
    • /
    • v.49 no.3
    • /
    • pp.187-196
    • /
    • 2016
  • This study was performed to improve the foaming generated in the effluent of wastewater treatment plant from March 2015 to July 2016. The main cause of foaming was air entrainment by an impinging jet and the internal accumulation by the diffusion barrier. Particularly, the foam growth was most active when there is low tide and larger discharge. To solve this problem, we experimented after installing fine mesh screen and the artificial channel device with underwater discharging outlet in the treated wastewater discharge channel and the outlet, respectively. As a result, the effects of foam reduction by devices ranged 85.0~92.0% and 70.7~85.6%, respectively. In addition, the foam and the noise were easily solved, first of all look to contribute to the prevention of complaints. Our device studies were applied to a single wastewater treatment plant. However, it is considered to be able to apply in other similar cases of domestic sewage treatment plants.