• Title/Summary/Keyword: active motion

Search Result 921, Processing Time 0.027 seconds

Three cases meniscus injury treated with Shinbaro pharmacopuncture therapy

  • Lee, So Jin;Yoon, Tae Kyung;Shin, Soo Ji;Ahn, Sang Min;Lee, Seong Jin;Won, Jeong Yoon;Jang, Yeo Jin
    • Journal of Acupuncture Research
    • /
    • v.34 no.3
    • /
    • pp.109-119
    • /
    • 2017
  • Objectives : The purpose of this report was to show that oriental therapy, specifically Shinbaro pharmacopuncture is effective for improvement of symptoms and and range of motion (ROM) in patients diagnosed with meniscus tears in the knee. Methods : Three patients were treated with herbal medicine, acupuncture, cupping, Shinbaro pharmacopuncture. The efficacies of the treatments in the three cases were assessed and the progress of the three cases were measured Numerical Rating Scale (NRS), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), European Quality of Life five dimensions dimensions (EQ-5D), and range of motion (ROM) measurements. Results : After all the treatments, NRS, WOMAC, and EQ-5D decreased. Active and passive ROM of the knee increased. Conclusion : These reports show the effect of Shinbaro pharmacopucture on a meniscus tear. Due to the small number of cases in this study, further case reports are needed.

An empirical bracketed duration relation for stable continental regions of North America

  • Lee, Jongwon;Green, Russell A.
    • Earthquakes and Structures
    • /
    • v.3 no.1
    • /
    • pp.1-15
    • /
    • 2012
  • An empirical predictive relationship correlating bracketed duration to earthquake magnitude, site-to-source distance, and local site conditions (i.e. rock vs. stiff soil) for stable continental regions of North America is presented herein. The correlation was developed from data from 620 horizontal motions for central and eastern North America (CENA), consisting of 28 recorded motions and 592 scaled motions. The bracketed duration data was comprised of nonzero and zero durations. The non-linear mixed-effects regression technique was used to fit a predictive model to the nonzero duration data. To account for the zero duration data, logistic regression was conducted to model the probability of zero duration occurrences. Then, the probability models were applied as weighting functions to the NLME regression results. Comparing the bracketed durations for CENA motions with those from active shallow crustal regions (e.g. western North America: WNA), the motions in CENA have longer bracketed durations than those in the WNA. Especially for larger magnitudes at far distances, the bracketed durations in CENA tend to be significantly longer than those in WNA.

Concurrent Validity, Inter-Tester and Intra-Tester Reliability of Goniometric Measurement of Active Elbow Range of Motion Using 4 Different Types of Measuring Instruments (주관절 가동범위 측정법에 대한 동시타당도와 신뢰도)

  • Current, Marion E.;Yi, Chung-Hwi
    • Physical Therapy Korea
    • /
    • v.2 no.2
    • /
    • pp.46-55
    • /
    • 1995
  • The purpose of this study was to assess the concurrent validity and reliability of goniometric measurement of joint motion. Subjects were 40 healthy university students. Measurements were performed by 4 inexperienced physical therapy students. Four different instruments were used and three readings were taken with each instrument in random order making a total of 12 readings for flexion of the right elbow of each subject. Goniometers used were 1. universal 2. fluid-based goniometer/inclinometer 3. digital LCD goniometer 4. electronic goniometer/torsiometer. The results were as follows: Concurrent validity was highest (r= .94) with the universal and digital LCD tools. Interrater reliability (Pearson Product Moment Correlation) was good for each tool. Interrater reliability calculated by ICC(2,1) was highest (.96) with the tensiometer and lowest (.78) with the digital LCD goniometer. Intrarater reliability calculated by ICC was excellent (${\geq}.90$) for all instruments. These results show that concurrent validity, intrarater and interrater reliability are very good in the used of all four types of goniometers/inclinometer/tensiometer, even with inexperienced raters. These results confirm the almost universal reliance on hand held goniometers for joint measurement by physical therapists as being a reliable practice. Further research should be done clinically with actual patients.

  • PDF

LOS(line-of-sight) Stabilization Control of OTM(on-the-move) Antenna Driven by Geared Flexible Transmission Mechanism (기어와 유연축을 갖는 구동계로 구동되는 OTM 안테나 시선의 안정화 제어)

  • Kang, Min-Sig;Yoon, Wo-Hyun;Lee, Jong-Bee
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.10
    • /
    • pp.951-959
    • /
    • 2011
  • In this study, an OTM(on-the-move) antenna which is mounted on ground vehicles and is used for mobile communication between vehicle and satellite while moving was addressed. Since LOS(line-of-sight) of antenna should direct satellite consistently while vehicle moving to guarantee high satellite communication quality, active antenna LOS stabilization is a core technology for OTM antenna. Stabilization of a satellite tracking antenna which consists of 2-DOF gimbals, an elevation gimbal over an azimuth gimbal, was considered in this study. In consideration of driving mechanism which consists of gear train and flexible driving shafts, a two-mass-system dynamic model coupled with vehicle motion was presented. An internal PI-control loop + outer PI-control loop structure has been suggested in order to damp the torsional vibration and stabilize control system. The classical pole-placement method was applied to design control gains. In addition, a vehicle motion compensation control beside of the feedback control loop has been suggested to improve LOS stabilization performances. The feasibility of the proposed control design was verified along with some experimental results.

Implementation of Excitatory CMOS Neuron Oscillator for Robot Motion Control Unit

  • Lu, Jing;Yang, Jing;Kim, Yong-Bin;Ayers, Joseph;Kim, Kyung Ki
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.14 no.4
    • /
    • pp.383-390
    • /
    • 2014
  • This paper presents an excitatory CMOS neuron oscillator circuit design, which can synchronize two neuron-bursting patterns. The excitatory CMOS neuron oscillator is composed of CMOS neurons and CMOS excitatory synapses. And the neurons and synapses are connected into a close loop. The CMOS neuron is based on the Hindmarsh-Rose (HR) neuron model and excitatory synapse is based on the chemical synapse model. In order to fabricate using a 0.18 um CMOS standard process technology with 1.8V compatible transistors, both time and amplitude scaling of HR neuron model is adopted. This full-chip integration minimizes the power consumption and circuit size, which is ideal for motion control unit of the proposed bio-mimetic micro-robot. The experimental results demonstrate that the proposed excitatory CMOS neuron oscillator performs the expected waveforms with scaled time and amplitude. The active silicon area of the fabricated chip is $1.1mm^2$ including I/O pads.

Stabilization Control of line of sight of OTM(On-The-Move) Antenna (OTM 단말기 안테나 시선 안정화 제어)

  • Kang, Min-Sig;Cho, Yong-Wan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.11
    • /
    • pp.2073-2082
    • /
    • 2010
  • The 4-th generation of mobile communication aims to realize global, fast and mobile communication service. The satellite communication charges a key role in this field. In this study, an OTM(On-The-Move) antenna which is mounted on ground vehicles and is used for mobile communication between vehicle and satellite was addressed. Since vehicles move during communication, active antenna line-of-sight stabilization is a core technology to guarantee high satellite communication quality. Stabilization of a satellite tracking antenna which consists of 2-DOF gimbals, an elevation gimbal over an azimuth gimbal, was considered in this study. Various disturbance torques such as static and dynamic mass imbalance torques, variation of moment of inertia according to elevation angle, friction torque related to vehicle motion, equivalent disturbance torque due to antenna roll motion, etc. were analyzed. As a robust stabilization control, rate feedback with sliding mode control and position feedback with proportional+integral control was suggested. To compensate antenna roll motion, a supplementary roll rate feed forward control was included beside of the feedback control loop. The feasibility of the analysis and the proposed control design were verified along with some simulation results.

New Fixation Method Using Two Crossing Screws and Locking Plate for Cubitus Varus Deformity in Young Adult Elbow: Case Report

  • Kim, Byoung Jin;Seol, Jong Hwan;Kim, Myung Sun
    • Clinics in Shoulder and Elbow
    • /
    • v.19 no.1
    • /
    • pp.43-47
    • /
    • 2016
  • Many types of osteotomy have been proposed for the treatment of cubitus varus deformity of the elbow, and various methods for fixation of the osteotomy site have also been described. However, no method has been perfect. We treated two cases of cubitus varus elbow deformity with step-cut osteotomy using a new fixation method with two crossing screws and an anatomically designed locking plate. Active assisted elbow range of motion (ROM) exercise was permitted at postoperative 3 days, after removal of the drainage. Preoperative and postoperative humerus-elbow-wrist angles and ranges of motion of the two patients were compared. At 3 months followup, each patient had recovered the preoperative elbow ROM, and achieved the complete bony union of the osteotomy site and proper correction of the cubitus varus deformity. In addition, the appropriate remodeling of the lateral bony protrusion was observed. Therefore, we introduce a new fixation method for achievement of stable fixation allowing immediate postoperative elbow motion after corrective osteotomy for cubitus varus deformity in young adults.

Effects of Somatosensory Stimulation on Lower-Limb Joint Kinetic of Older Adult During Stair Descent (계단 하강 보행 동안 체성감각 자극이 노인의 하지 관절 역학에 미치는 영향)

  • Kwak, K.Y.;So, H.J.;Kim, S.H.;Yang, Y.S.;Kim, N.G.;Kim, D.W.
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.2
    • /
    • pp.93-104
    • /
    • 2011
  • The purpose of this study was to investigate lower-limb joint torque of the two groups as it changed by somatosensory stimulation during the descent down three stairs of different heights and to describe the difference between the two groups, which are young people group and elderly people group. Subjects of each groups climbed down a stair at four stimulation conditions, which are non-stimulation, tibialis anterior tendon stimulation, achilles tendon stimulation, tibialis anterior - achilles tendon stimulation. Motion capture data were collected using 3D optoelectric motion tracking system that utilizes active infrared LEDs, near infrared sensor and force plate. The obtained motion capture data was used to build 3D computer simulation model. The results show that lower-limb joint torque of the two groups changed with somatosensory stimulation as they descended the stairs and the joint torque of the two groups differed from each other.

Characteristics of the Muscular Activities on the Feedback Control of Elbow Orthosis Using Pneumatic Rubber Artificial Muscle (공압 고무 인공근육을 장착한 주관절 보조기 피드백 제어 시 근력 특성)

  • Hong, Kyung-Ju;Kim, Kyung;Kwon, Tae-Kyu;Kim, Dong-Wook;Kim, Nam-Gyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.4
    • /
    • pp.725-728
    • /
    • 2008
  • An elbow orthosis with a pneumatic rubber actuator has been developed to assist and enhance upper limbs movements and has been examined for the effectiveness. The effectiveness of the elbow orthosis was examined by comparing muscular activities during alternate dumbbell curl motion wearing and not wearing the orthosis. The subjects participated in the experiment were younger adults in their twenties. The subjects were instructed to perform dumbbell curl motion in a sitting position wearing and not wearing orthosis in turn and a dynamometer was used to measure elbow joint torque outputs in an isokinetic mode. Orthosis was controlled using contractile muscle force that is measured from force sensor through cDAQ-9172 board. The air pressure of the pneumatic actuator was 0.3MPa the most suitable air pressure. For the analysis of muscular activities, Electromyography of the subjects was measured during alternate dumbbell curl motion. The experiment results showed that the muscular activities wearing the elbow orthosis were reduced. With this, we confirmed the effectiveness of the developed elbow orthosis.

Ship Motion-Based Prediction of Damage Locations Using Bidirectional Long Short-Term Memory

  • Son, Hye-young;Kim, Gi-yong;Kang, Hee-jin;Choi, Jin;Lee, Dong-kon;Shin, Sung-chul
    • Journal of Ocean Engineering and Technology
    • /
    • v.36 no.5
    • /
    • pp.295-302
    • /
    • 2022
  • The initial response to a marine accident can play a key role to minimize the accident. Therefore, various decision support systems have been developed using sensors, simulations, and active response equipment. In this study, we developed an algorithm to predict damage locations using ship motion data with bidirectional long short-term memory (BiLSTM), a type of recurrent neural network. To reflect the low frequency ship motion characteristics, 200 time-series data collected for 100 s were considered as input values. Heave, roll, and pitch were used as features for the prediction model. The F1-score of the BiLSTM model was 0.92; this was an improvement over the F1-score of 0.90 of a prior model. Furthermore, 53 of 75 locations of damage had an F1-score above 0.90. The model predicted the damage location with high accuracy, allowing for a quick initial response even if the ship did not have flood sensors. The model can be used as input data with high accuracy for a real-time progressive flooding simulator on board.