• Title/Summary/Keyword: active motion

Search Result 921, Processing Time 0.025 seconds

Design of Assistive Wearable System for Walking (보행 보조 웨어러블 시스템 설계)

  • Choi, Seong-Dae;Lee, Sang-Hun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.12
    • /
    • pp.111-116
    • /
    • 2019
  • With the recent acceleration of industrial technologies and active research, wearable robot technologies have been applied to various fields. To study the utility of wearable robots, basic research on kinetic mechanisms of the human body, bio-signal analysis, and system control are essential. In this study, we investigated the basic structure of a wearable system and the operating principles of a driving mechanism. The control system and supporting structure, which comprise the driving mechanism, were designed and manufactured. Motion and load analyses were performed simultaneously for the design of the kinematic drive, and the driving mechanism was constructed by analyzing walking motion. The operating conditions of the cylinder were verified by stride via driving experiments. Further, the accuracy and responsiveness of the system were confirmed by comparison with actual motion, and the system safety was validated by applying loads.

Robust Action Recognition Using Multiple View Image Sequences (다중 시점 영상 시퀀스를 이용한 강인한 행동 인식)

  • Ahmad, Mohiuddin;Lee, Seong-Whan
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2006.10b
    • /
    • pp.509-514
    • /
    • 2006
  • Human action recognition is an active research area in computer vision. In this paper, we present a robust method for human action recognition by using combined information of human body shape and motion information with multiple views image sequence. The principal component analysis is used to extract the shape feature of human body and multiple block motion of the human body is used to extract the motion features of human. This combined information with multiple view sequences enhances the recognition of human action. We represent each action using a set of hidden Markov model and we model each action by multiple views. This characterizes the human action recognition from arbitrary view information. Several daily actions of elderly persons are modeled and tested by using this approach and they are correctly classified, which indicate the robustness of our method.

  • PDF

Development of Reflected Type Photoplethysmorgraph (PPG) Sensor with Motion Artifacts Reduction (생명신호 측정용 반사형 광용적맥파 측정기의 움직임에 의한 신호왜곡 제거)

  • Han, Hyo-Nyoung;Lee, Yun-Joo;Kim, Jung-Sik;Kim, Jung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.12
    • /
    • pp.146-153
    • /
    • 2009
  • One of the most important issues in the wearable healthcare sensors is to minimize the motion artifacts in the vital signals for continuous monitoring. This paper presents a reflected type photoplethysmograph (PPG) sensor for monitoring heart rates at the artery of the wrist. Active noise cancellation algorithm was applied to compensate the distorted signals by motions with Least Mean Square (LMS) adaptive filter algorithms, using acceleration signals from a MEMS accelerometer. Experiments with a watch type PPG sensor were performed to validate the proposed algorithm during typical daily motions such as walking and running. The developed sensor is suitable for ubiquitous healthcare system and monitoring vital arterial signals during surgery.

Bidirectional Motion of the Metal/Ceramic Composit Structure Linear Ultrasonic Motor (금속/세라믹 복합구조 선형 초음파 모터의 양방향 운동)

  • Lee, Jae-Hyung;Park, Tae-Gone;Kim, Myung-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.79-82
    • /
    • 2002
  • In this paper, a single phase driven piezoelectric motor design was presented for linear motion. Two metal/ceramic composite actuators, a piezoelectric ring which was bonded to a metal endcap from one side, were used as the active elements of this motor. The motor was composed of a piezoelectric ceramic, a metal ring which has 4 arms, and a guider. Motors with 30.0[mm] and 35.0[mm] diameter were studied by finite element analysis and experiments. As results, the maximum speed of motor was obtained at resonant frequency. When the applied voltage of the motor increased, the speed was increased. Also, bidirectional motion of the motor was achieved by combining two motors which have different resonant frequency.

  • PDF

Simulation of Three Dimensional Motion of the Knee Joint in Total Knee Arthroplasty (인공 무릎 관절의 3차원 운동 시뮬레이션)

  • Moon, Byung-Young;Son, Kwon;Kim, Ki-Bum;Seo, Jung-Tak
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.9
    • /
    • pp.188-195
    • /
    • 2004
  • Severe osteoarthrosis of the knee joint often requires total knee arthroplasty(TKA) to yield adequate knee function. The knee joint with TKA is expected ideally to restore the characteristics, however, this is not necessarily 1.ue in the clinical cases. In this study the motion of the intact joint and the joint after. TKA were investigated numerically using computer simulation. For active knee extension from 90 degrees of flexion to full extension, the intact knee joint exhibited anterior tibial translation near the full extension and it showed only rotation at other flexion angles. Physiologic external rotation of the tibia near full extension known as screw home movement was also noted in the analytical model. The analysis of the tibial insert of three different shapes (flat, semicurved, and curved types) demonstrated characteristic rotational and sliding motion as well as different contact forces.

A Study on Motion Graphic about Title Design in Hollywood Movies Trailer (할리우드 영화예고편 타이틀 디자인의 모션그래픽 연구)

  • Kim, Jong-Sung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.3
    • /
    • pp.1021-1026
    • /
    • 2012
  • The active use of motion graphic in the production of digital movies contents is a significant way to deliver the contents' messages clearly and intensely. The analysis of film expression characters of digital movies contents based on the motion effect provides a good tool to present an effective method for the production of films using motion graphic. Motion graphic, which can animate motionless movies and graphic images dynamically, is now used as an excellent tool in the editing of digital movies. So, this study aims to show systematically the expression characters of digital movies contents by using the production of films of motion graphic. It also aims to suggest an efficient production of films by analyzing major contents produced with motion graphic and after that examining their types and skills according to the genres and times.

Assessment of seismic parameters for 6 February 2023 Kahramanmaraş earthquakes

  • Bilal Balun
    • Structural Engineering and Mechanics
    • /
    • v.88 no.2
    • /
    • pp.117-128
    • /
    • 2023
  • On February 6, 2023, Türkiye woke up with a strong ground motion felt in a wide geography. As a result of the Kahramanmaraş, Pazarcık and Elbistan earthquakes, which took place 9 hours apart, there was great destruction and loss of life. The 2023 Kahramanmaraş earthquakes occurred on active faults known to pose a high seismic hazard, but their effects were devastating. Seismic code spectra were investigated in Hatay, Adıyaman and Kahramanmaraş where destruction is high. The study mainly focuses on the investigation of ground motion parameters of 6 February Kahramanmaraş earthquakes and the correlation between ground motion parameters. In addition, earthquakes greater than Mw 5.0 that occurred in Türkiye were compared with certain seismic parameters. As in the strong ground motion studies, seismic energy parameters such as Arias intensity, characteristic intensity, cumulative absolute velocity and specific energy density were determined, especially considering the duration content of the earthquake. Based on the study, it was concluded that the structures were overloaded far beyond their normal design levels. This, coupled with significant vertical seismic components, is a contributing factor to the collapse of many buildings in the area. In the evaluation made on Arias intensity, much more energy (approximately ten times) emerged in Kahramanmaraş earthquakes compared to other Türkiye earthquakes. No good correlation was found between moment magnitude and peak ground accelerations, peak ground velocities, Arias intensities and ground motion durations in Türkiye earthquakes. Both high seismic components and long ground motion durations caused intense energy to be transferred to the structures. No strong correlation was found between ground motion durations and other seismic parameters. There is a strong positive correlation between PGA and seismic energy parameter AI. Kahramanmaraş earthquakes revealed that changes should be made in the Turkish seismic code to predict higher spectral acceleration values, especially in earthquake-prone regions in Türkiye.

Development of an Active Training System for Rehabilitation Exercise of Hemiplegic Patients (편마비 환자의 재활운동치료를 위한 능동형 상지훈련시스템 개발)

  • Lee, M.H.;Son, J.;Kim, J.Y.;Kim, Y.H.
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.1
    • /
    • pp.1-6
    • /
    • 2011
  • An active training system has been developed to assist the upper extremity function in patients with spasticity. We also evaluated the performance of the developed assistive system in five normal subjects and one hemiplegic patient. The maximum voluntary contraction (MVC) tests for biceps brachii and triceps brachii were performed and the relationship between linear enveloped EMG signal and the elbow joint torque was found. In order to implement an active training, our system was designed to allow isokinetic movement only when the subject generates elbow joint motion larger than the pre-fixed threshold level. The proposed EMG-feedback control method could provide active exercises, resulting in better rehabilitation protocol for spastic patients.