• Title/Summary/Keyword: active machinery

Search Result 180, Processing Time 0.021 seconds

The Introduction of Shaft Alignment Calculation for very Large Container Vessel (초대형 콘테이너선의 축계정렬 계산 사례 소개)

  • Kang Dong Chun;Park Kun Woo;Kim Kyoung Ho
    • Special Issue of the Society of Naval Architects of Korea
    • /
    • 2005.06a
    • /
    • pp.138-143
    • /
    • 2005
  • Recently, it is much more required to approach the accurate shaft alignment analysis according to the tendency of active showing in large container vessel and that of the heavy weight of propeller in connection with it. Shaft alignment calculation lies upon how the pressure apply on bearings properly in operation of main engine and how the stress of shaft puts within that of limit of bearing material and how the movement of shaft is prospected owing to propeller forces and moments. Therefore, we have conducted the shaft alignment calculation of very large container vessel considering the deformation of hull structure and the propeller forces and moments and the static and dynamic condition of shaft. The calculation results show the pressure distribution of aft bush and the movement of shaft in bearing. The shaft alignment calculation helps the stable application of shaft alignment, which was proved in sea trial.

  • PDF

Numerical Simulation of the Odor Spreading in a Factory (공장에서 퍼지는 냄새에 관한 수치계산적 연구)

  • Vincent, Lijo;Song, Eun-Hwa;Nam, Hyun-Kyu;Shin, Choon-Sik;Kim, Heuy-Dong
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2540-2543
    • /
    • 2008
  • Liquid crystal displays (LCD's) are continuously coated with some chemicals in the clean room of a factory. Spreading of these chemicals is causing serious problems both in controlling clean room quality as well as to the workers inside the factory. It is required to alleviate or properly control the offensive odor which is mainly composed of propylene glycol mono ethyl acetate, novolak resin and photo active compound. The control strategy employed is to bleed the offensive odor gas out the clean room. A full scale 3D CFD model was created with anisotropic porous media, chemical species transport with no volumetric reaction, and thermal diffusion with propane gas (tracer gas) to simulate the odor spreading. A segregated implicit solver with standard k-$\varepsilon$ model is employed. The detailed CFD analysis made it possible to develop an effective method of ventilating the coater room and optimizing their capacities.

  • PDF

Active Control of Propagated Noise through Opening of Enclosures Surrounding a Noise Source (음원을 둘러싼 인클로저 개구부를 통해 전파되는 소음의 능동 제어)

  • Lee, Hanwool;Hong, Chinsuk;Jeong, Weuibong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.25 no.4
    • /
    • pp.223-231
    • /
    • 2015
  • Enclosures are widely used to alleviate the contribution of machinery noise. It has been long concerned with the noise transmission through the access openings of the enclosures. In this study, we investigate active noise control technology for reduction of the transmission. A numerical model based on the acoustic boundary element method is first established. Using the numerical model, the acoustic transfer functions of the field points over the opening to the primary source at arbitrary locations are estimated. The feedforward control to minimize the acoustic power through the opening is then numerically implemented. The controller drives the secondary source to destructively interfere the noise transmission through the opening. Finally, a parametric study is conducted to evaluate the effects of the location and the number of the microphones on the control performance. Furthermore, the effects of the location of the secondary source on the performance of active noise control are investigated. It is followed that the control system implemented in this study leads to a significant reduction of about 31.5 dB in the sound power through the opening using only one secondary source located at the optimized position.

Three-Phase Current Source Type ZVS-PWM Controlled PFC Rectifier with Single Active Auxiliary Resonant Snubber and Its Feasible Evaluations

  • Masayoshi Yamamoto;Shinji Sato;Tarek Ahmed;Eiji Hiraki;Lee, Hyun-Woo;Mutsuo Nakaoka
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.4B no.3
    • /
    • pp.127-133
    • /
    • 2004
  • This paper presents a prototype of three-phase current source zero voltage soft-switching PWM controlled PFC rectifier with Single Active Auxiliary Resonant Commutated Snubber (ARCS) circuit topology. The proposed three-phase PFC rectifier with sinewave current shaping and unity power factor scheme can operate under a condition of Zero Voltage Soft Switching (ZVS) in the main three phase rectifier circuit and zero current soft switching (ZCS) in auxiliary snubber circuits. The operating principle and steady-state performances of the proposed three-phase current source soft-switching PWM controlled PFC rectifier controlled by the DSP control implementation are evaluated and discussed on the basis of the experimental results of this active rectifier setup.

Active Vibration Control of Three-Stage Mast of Reach Truck (리치트럭의 3단 마스트 흔들림 능동 제어)

  • Moon, Hyeon Mo;Yoo, Kwang-Seon;Ahn, Young-Chul;Mah, Pyeong-Ho;Lee, Chul-Hee
    • Journal of Drive and Control
    • /
    • v.16 no.3
    • /
    • pp.1-7
    • /
    • 2019
  • The reach truck, which is mainly used in warehouses, is required to have high-mast to improve its working efficiency and space utilization. The high-mast takes advantage of more vertical space but severe vibrations are easily generated at the end of the high-mast. These vibrations may cause a collision or misplacement of loading location at work. In this study, the vibration characteristics of a three-stage high-mast of a reach truck are analyzed, and an active vibration controller verified through a similar experiment is designed to reduce this vibration. A similar experiment for reach truck mast verifies the performance of the active vibration controller. By applying an active vibration controller designed for a real reach truck, the operations of the reach truck are made more efficient through the reduction of the vibration amplitude.

Analysis of Receiving Strength according to the Attachment Location of RFID tag in Palletized Unit-load of Agricultural Products

  • Jong Min Park;Eon Uck Kang;Hyun Mo Jung
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.29 no.3
    • /
    • pp.211-221
    • /
    • 2023
  • This study was conducted as a basic study for the selection of tags suitable for logistics management in the palletized unit-load unit and the development of various technologies to activate the palletized unit-load shipment of agricultural products through local APCs. Three types of passive RFID tags of UHF 900 MHz and one type of active RFID tag of 2.4 GHz band designed and manufactured through this study were used to analyze the receiving strength according to the tag's attachment location and distance of the palletized unit-load of agricultural products. In the passive RFID tag, there was a large difference in receiving strength by the tag's attachment location and a large amount of data loss depending on the distance within 30 m, whereas, in the active RFID tag, it was superior to the passive tags in terms of both receiving strength and data loss. Therefore, active tags are desirable from the perspective of multiple identification of warehouses with large spaces in relation to the application of RFID tags for palletized unit-loads of agricultural products, but the development of low-power technologies such as software wakeup power management as well as hardware to minimize battery power consumption is necessary.

REPONSE OF POLYMERIC MEMBRANES AS SENSING ELEMENTS FOR ELECTRONIC TOUGUE

  • Bae, Y.M.;Cho, S.I.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2000.11b
    • /
    • pp.219-226
    • /
    • 2000
  • The study was executed for development of sensing elements of electronic tongue which could discriminate taste of liquid and semi-liquid foods. Five polymeric membranes which were composed of polymer, plasticizer, electro-active materials were prepared. After each polymeric membranes were mounted in an electrode body, membrane potentials due to electrochemical reaction with taste stimuli were measured. The experimental results were interpreted in view of the membrane's non-selective responses to stimuli.

  • PDF

Surface Treatment of Steel by Plasma Boronizing

  • Lee, G.H.;Na, K.S.m;Kwon, S.C.;Kim, S.K.
    • Journal of the Korean Vacuum Society
    • /
    • v.4 no.S2
    • /
    • pp.49-57
    • /
    • 1995
  • At present the processes of boronizing have been mostly studied in a plasma from gaseous compounds containing the impregnating element and are in an industrial use. These have been investigated by a variety of works in a glow discharge with different mixture ratios of $B_2H_6$ and $H_2$ as well as $BCl_3$ and $H_2$. The active atomosphere has been diluted by Ar or some other inert gas in order to enhance control of boron potential and to reduce the ignition voltage of the glow discharge. The Control of gaseous atomosphere is essential to a boride layer in plamsa boronizing treatment. The boride formation is required to make the workpiece surface saturated with boron content. The present study considers the efficiency of plasma boronizing reactions and the morphology of boride layer under various plasma conditions

  • PDF

A Performance Analysis of Active Mount with Moving-Coil type Electromagnetic Actuator Installed on the Elastic Foundation (탄성지지된 가동코일형 능동마운트의 성능 분석)

  • Jung, Woo-Jin;Bae, Soo-Ryong;Jeon, Jae-Jin
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.227-231
    • /
    • 2014
  • Underwater radiated noise is one of the vital factors in underwater weapon systems like submarine. A passive elastic mount is an effective reduction method for the vibration from a ship-board machinery transmitted to the hull which is radiated as noise outside the hull. A passive elastic mount shows the limitation on the vibration reduction and needs multi stage mounting system including double stage one to meet the required underwater radiated noise criteria. It is necessary for the multi stage mounting system to consider the large displacement in the underwater shock explosion. So it is difficult to apply the multi stage mounting system in submarine because of space limitation. Also recent navy sonar system are trying to have the capability to detect the ship-borne acoustic signals in the low frequency range. An alternative to the passive mount is an active mount with moving-coil type electromagnetic actuator based on a conventional rubber mount in the low frequency range. In the previous paper, 4 active mounts with moving-coil type electromagnetic actuator based on the rubber mount were installed on the hard floor of the facility, which means no consideration on the elastic foundation effect for the control of the active mounts was taken into account. In this study, an experimental performance analysis on the active mount was carried out using 4 active mounts installed on the cylindrical structure to investigate the elastic foundation effect.

  • PDF

Active Vibration Control of 1/4 Vehicle Model using Electro-magnetic Actuator (전자기 액튜에이터를 이용한 1/4차량 모델의 능동 진동 제어에 관한 연구)

  • Heo, Sin;Choe, Gang-Yun;Kim, Yu-Il
    • 연구논문집
    • /
    • s.23
    • /
    • pp.81-92
    • /
    • 1993
  • In this study, quarter vehicle model is used to analyse vibration control effects for ride comfort and handling safety according to this three kinds of control methods, which are the modal control, the sky-hook control and the linear viscous damping control. We performed theoretical analysis and experiments and compared two results. In experiments, electro-magnetic actuator was employed as a force actuator. It is shown that all three methods can effectively control the vehicle model. The modal control method gives similar control results using gain less than the viscous damping control.

  • PDF