• Title/Summary/Keyword: active beam

Search Result 469, Processing Time 0.029 seconds

The study of improving the performance of lower direction finding ability due to the interfered phase difference of circular array Antennas (원형배열안테나의 위상간섭에 의한 방향탐지 성능저하 개선연구)

  • Chung, Jae-Woo;Kim, Young-Kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.05a
    • /
    • pp.535-539
    • /
    • 2010
  • This paper include to study DoA(Direction of Arrival) for radio collection and monitoring system. The direction finding calculated by applying the CVDF (Correlation Vector Direction Finding) algorithm for the five circular dipole antenna over V / UHF band. To improve the accuracy of direction finding by applying CVDF algorithm needs to obtain ideal phase difference each antennas. However, a circular array antenna phase difference pattern may be distorted on a specific frequency band or to particular direction. The effect of installing each array antennas circularly and the effect of the interference of center pole (located in the center of a circular array antenna mount) may make the distortion of phase pattern. If you use an active antenna instead of passive antenna to obtain good sensitivity, you would measure the more distortion. This paper propose how to change combination of antennas to measure the phase in real-time and how to use antenna beam patterns for minimizing the degradation phenomena at applying simple CVDF algorithm and increasing the direction finding capability.

  • PDF

The improvement of electrical properties of InGaZnO (IGZO)4(IGZO) TFT by treating post-annealing process in different temperatures.

  • Kim, Soon-Jae;Lee, Hoo-Jeong;Yoo, Hee-Jun;Park, Gum-Hee;Kim, Tae-Wook;Roh, Yong-Han
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.169-169
    • /
    • 2010
  • As display industry requires various applications for future display technology, which can guarantees high level of flexibility and transparency on display panel, oxide semiconductor materials are regarded as one of the best candidates. $InGaZnO_4$(IGZO) has gathered much attention as a post-transition metal oxide used in active layer in thin-film transistor. Due to its high mobility fabricated at low temperature fabrication process, which is proper for application to display backplanes and use in flexible and/or transparent electronics. Electrical performance of amorphous oxide semiconductors depends on the resistance of the interface between source/drain metal contact and active layer. It is also affected by sheet resistance on IGZO thin film. Controlling contact/sheet resistance has been a hot issue for improving electrical properties of AOS(Amorphous oxide semiconductor). To overcome this problem, post-annealing has been introduced. In other words, through post-annealing process, saturation mobility, on/off ratio, drain current of the device all increase. In this research, we studied on the relation between device's resistance and post-annealing temperature. So far as many post-annealing effects have been reported, this research especially analyzed the change of electrical properties by increasing post-annealing temperature. We fabricated 6 main samples. After a-IGZO deposition, Samples were post-annealed in 5 different temperatures; as-deposited, $100^{\circ}C$, $200^{\circ}C$, $300^{\circ}C$, $400^{\circ}C$ and $500^{\circ}C$. Metal deposition was done on these samples by using Mo through E-beam evaporation. For analysis, three analysis methods were used; IV-characteristics by probe station, surface roughness by AFM, metal oxidation by FE-SEM. Experimental results say that contact resistance increased because of the metal oxidation on metal contact and rough surface of a-IGZO layer. we can suggest some of the possible solutions to overcome resistance effect for the improvement of TFT electrical performances.

  • PDF

High-resolution range and velocity estimation method based on generalized sinusoidal frequency modulation for high-speed underwater vehicle detection (고속 수중운동체 탐지를 위한 일반화된 사인파 주파수 변조 기반 고해상도 거리 및 속도 추정 기법)

  • Jinuk Park;Geunhwan Kim;Jongwon Seok;Jungpyo Hong
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.4
    • /
    • pp.320-328
    • /
    • 2023
  • Underwater active target detection is vital for defense systems, requiring accurate detection and estimation of distance and velocity. Sequential transmission is necessary at each beam angle, but divided pulse length leads to range ambiguity. Multi-frequency transmission results in time-bandwidth product losses when bandwidth is divided. To overcome these problem, we propose a novel method using Generalized Sinusoidal Frequency Modulation (GSFM) for rapid target detection, enabling low-correlation pulses between subpulses without bandwidth division. The proposed method allows for rapid updates of the distance and velocity of target by employing GSFM with minimized pulse length. To evaluate our method, we simulated an underwater environment with reverberation. In the simulation, a linear frequency modulation of 0.05 s caused an average distance estimation error of 50 % and a velocity estimation error of 103 % due to limited frequency band. In contrast, GSFM accurately and quickly tracked targets with distance and velocity estimation errors of 10 % and 14 %, respectively, even with pulses of the same length. Furthermore, GSFM provided approximate azimuth information by transmitting highly orthogonal subpulses for each azimuth.

Development of $14"{\times}8.5"$ active matrix flat-panel digital x-ray detector system and Imaging performance (평판 디지털 X-ray 검출기의 개발과 성능 평가에 관한 연구)

  • Park, Ji-Koon;Choi, Jang-Yong;Kang, Sang-Sik;Lee, Dong-Gil;Seok, Dae-Woo;Nam, Sang Hee
    • Journal of radiological science and technology
    • /
    • v.26 no.4
    • /
    • pp.39-46
    • /
    • 2003
  • Digital radiographic systems based on solid-state detectors, commonly referred to as flat-panel detectors, are gaining popularity in clinical practice. Large area, flat panel solid state detectors are being investigated for digital radiography. The purpose of this work was to evaluate the active matrix flat panel digital x-ray detectors in terms of their modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE). In this paper, development and evaluation of a selenium-based flat-panel digital x-ray detector are described. The prototype detector has a pixel pitch of $139\;{\mu}m$ and a total active imaging area of $14{\times}8.5\;inch^2$, giving a total 3.9 million pixels. This detector include a x-ray imaging layer of amorphous selenium as a photoconductor which is evaporated in vacuum state on a TFT flat panel, to make signals in proportion to incident x-ray. The film thickness was about $500\;{\mu}m$. To evaluate the imaging performance of the digital radiography(DR) system developed in our group, sensitivity, linearity, the modulation transfer function(MTF), noise power spectrum (NPS) and detective quantum efficiency(DQE) of detector was measured. The measured sensitivity was $4.16{\times}10^6\;ehp/pixel{\cdot}mR$ at the bias field of $10\;V/{\mu}m$ : The beam condition was 41.9\;KeV. Measured MTF at 2.5\;lp/mm was 52%, and the DQE at 1.5\;lp/mm was 75%. And the excellent linearity was showed where the coefficient of determination ($r^2$) is 0.9693.

  • PDF

Nano-fabrication of Superconducting Electrodes for New Type of LEDs

  • Huh, Jae-Hoon;Endoh, Michiaki;Sato, Hiroyasu;Ito, Saki;Idutsu, Yasuhiro;Suemune, Ikuo
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2009.02a
    • /
    • pp.133-134
    • /
    • 2009
  • Cold temperature development (CTD) of electron beam (EB) patterned resists and subsequent dry etching were investigated for fabrication of nano-patterned Niobium (Nb). Bulky Nb fims on GaAs substrates were deposited with EB evaporation. Line patterns on Nb cathode were fabricated by EB patterning and reactive ion etching (RIE). Size deviations of nano-sized line patterns from CAD designed patterns are dependent on the EB total exposure, but it can be improved by CTD of EB-exposed resist. Line patterns of 10 to 300 nm widths of EB-exposed resist patterns were drawn under various exposure conditions of $0.2{\mu}s$/dot (total 240,000 dot) with a constant current (50 pA). Compared with room temperature development (RTD), the CTD improves pattern resolution due to the suppression of backscattering effect. RIE with $CF_4$ was performed for formation of several nano-sized line patterns on Nb. Each EB-resist patterned samples with RTDs and CTDs were etched with two different $CF_4$ gas pressures of 5 Pa. Nb etching rate increases while GaAs (or ZEP) etching rate decreases as the chamber pressure increases. This different dependent of the etching rate on the $CF_4$ pressure between Nb and GaAs (or ZEP) has a significant meaning because selective etching of nano-sized Nb line patterns is possible without etching of the underlying active layer.

  • PDF

Correlation between Radiographic Findings, Clinical Findings and Joint Sounds of Temporomandibular Joint Osteoarthritis Patients

  • Shin, Jung-Youn;Ahn, Jong-Mo
    • Journal of Oral Medicine and Pain
    • /
    • v.42 no.2
    • /
    • pp.35-43
    • /
    • 2017
  • Purpose: This study aims to evaluate the correlation between joint sounds and radiographic bone change patterns along with clinical symptoms of temporomandibular joint osteoarthritis (TMJ OA) patients. Methods: The patients for this study were over 19 years of age, diagnosed tentatively with TMJ OA. The patients were examined with temporomandibular disorders analysis test and all three radiographs, including panoramic radiography, transcranial radiography, and cone beam computed tomography (CBCT). Information of the patients' age, pain status, joint sound and mouth opening range were collected. And bone change pattern was examined by reviewing panoramic radiography, transcranial radiography and CBCT images. Results: The patients with crepitus had a higher average active mouth opening (AMO) range than patients without crepitus, and the group with bilateral crepitus had a higher average AMO range than the group with unilateral crepitus (p<0.001). And the patient with pain during mastication was increased in the group with clicking than the group without clicking, and the group with bilateral clicking showed a statistically significant increase in the patient with pain during mastication than the group with unilateral clicking (p<0.05). The analytical results of the relevance of crepitus showed a high correlation with bone change observed from each of the three radiographs. And the agreement in bone change findings from 3 groups of paired radiographs showed high agreement (p<0.001). Meanwhile, 77.2% of CBCT findings showed bone change of condyle without crepitus (p<0.001). Conclusions: This study presented significant results in the evaluation of the correlation with crepitus and bone change of TMJ OA patients from panoramic radiography or transcranial projection. However, the accurate assessment is required through CBCT for the patient with complains of persistent pain, limitation of mouth opening, and occlusal change even if the crepitus does not exist.

Micromachinng and Fabrication of Thin Filmes for MEMS-infrarad Detectors

  • Hoang, Geun-Chang;Yom, Snag-Seop;Park, Heung-Woo;Park, Yun-Kwon;Ju, Byeong-Kwon;Oh, Young-Jei;Lee, Jong-Hoon;Moonkyo Chung;Suh, Sang-Hee
    • The Korean Journal of Ceramics
    • /
    • v.7 no.1
    • /
    • pp.36-40
    • /
    • 2001
  • In order to fabricate uncooled IR sensors for pyroelectric applications, multilayered thin films of Pt/PbTiO$_3$/Pt/Ti/Si$_3$N$_4$/SiO$_2$/Si and thermally isolating membrane structures of square-shaped/cantilevers-shaped microstructures were prepared. Cavity was also fabricated via direct silicon wafer bonding and etching technique. Metallic Pt layer was deposited by ion beam sputtering while PbTiO$_3$ thin films were prepared by sol-gel technique. Micromachining technology was used to fabricate microstructured-membrane detectors. In order to avoid a difficulty of etching active layers, silicon-nitride membrane structure was fabricated through the direct bonding and etching of the silicon wafer. Although multilayered thin film deposition and device fabrications were processed independently, these could b integrated to make IR micro-sensor devices.

  • PDF

Calibration of TEPC for CubeSat Experiment to Measure Space Radiation

  • Nam, Uk-Won;Park, Won-Kee;Lee, Jaejin;Pyo, Jeonghyun;Moon, Bong-Kon;Lee, Dae-Hee;Kim, Sunghwan;Jin, Ho;Lee, Seongwhan;Kim, Jungho;Kitamura, Hisashi;Uchihori, Yukio
    • Journal of Astronomy and Space Sciences
    • /
    • v.32 no.2
    • /
    • pp.145-149
    • /
    • 2015
  • A newly designed Tissue Equivalent Proportional Counter (TEPC) has been developed for the CubeSat mission, SIGMA (Scientific cubesat with Instruments for Global Magnetic field and rAdiation) to investigate space radiation. In order to test the performance of the TEPC, we have performed heavy ion beam experiments with the Heavy Ion Medical Accelerator in Chiba (HIMAC), Japan. In space, human cells can be exposed to complex radiation sources, such as X-ray, Gamma ray, energetic electrons, protons, neutrons and heavy charged particles in a huge range of energies. These generate much a larger range of Linear Energy Transfer (LET) than on the ground and cause unexpected effects on human cells. In order to measure a large range of LET, from 0.3 to $1,000keV/{\mu}m$, we developed a compact TEPC which measures ionized particles produced by collisions between radiation sources and tissue equivalent materials in the detector. By measuring LET spectra, we can easily derive the equivalent dose from the complicated space radiation field. In this HIMAC experiment, we successfully obtained the linearity response for the TEPC with Fe 500 MeV/u and C 290 MeV/u beams and demonstrated the performance of the active radiation detector.

An Antibiotic against Bacillus amyloliquefaciens from Streptomyces sp. KM-48 (Streptomyces 속 KM-48 균주가 생성하는 Bacillus amyloliquefaciens 에 대한 항생물질)

  • Lee, Sang-Man;Song, Bang-Ho
    • Microbiology and Biotechnology Letters
    • /
    • v.11 no.1
    • /
    • pp.39-45
    • /
    • 1983
  • One of Streptomyces sp. was screened as an antibiotic producing strain against Gram positive bacteria specifically from about one hundred Actinomycetes collections. The isolated KM-48 strain, indexed in our collection, was secreted an anbitiotic in nutrient broth culture. The active principle was extracted with acetone from the lyophilized solid of cultured filtrate. The nonadsorbed elute in aluminium oxide was isolated as a purified homogeneity which revealed a sing1e spot under ultra-violet beam on avicel thin layer chromatography. The isolated antibiotic was sensitive specifically against the Gram positive bacteria and fungi. About fifty percent inhibition of the control growth on Bacillus amyloliquefaciens was 18$\mu\textrm{g}$/$m\ell$. The antibiotic was lavile against thermotreatment and stabled in acidic condition remarkably. The KM-48 was identified as a similar strain to Streptomyces tsusimaensis on its morphological and cultural characteristics.

  • PDF

An Experimental Performance Evaluation with Xenomai for WSN (WSN을 위한 Xenomai의 실험적 성능평가)

  • Son, Tae-Yeong;Rim, Seong-Rak
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.1
    • /
    • pp.709-714
    • /
    • 2017
  • Structures like bridges or buildings need to be checked continuously to diagnose their safety. However, it is extremely difficult for the people who access such structures to check all areas directly. To overcome this problem, there is a lot of active research into structural health monitoring (SHM) with wireless sensor nodes (WSNs). In this paper, for more accurate checking of SHM with WSNs, we experimentally compare and evaluate the performance of Xenomai, which provides real-time processing under the traditional Linux kernel. For this purpose, we patch Xenomai into the traditional Linux kernel of a commercial embedded board, Raspberry Pi, and implement a task that periodically reads vibration data of the z-axis from an accelerometer in order to analyze the natural frequency of cantilever beams. Reading the data from the traditional Linux kernel with the same method, we analyze the natural frequency of the cantilever beams using Smart Office Analyzer. Finally, to review the validity of Xenomai for WSNs, we obtain vibration data on the z-axis from the accelerometer via wired network and compared and analyzed them the same way.