• 제목/요약/키워드: activated carbon removal efficiency

검색결과 318건 처리시간 0.024초

은나노 활성탄에 의한 하수 2차 처리수 중의 오염물질 제거 특성에 관한 연구 (A Study on the Characteristics of Pollutant Removal in Secondary Effluent from Wastewater Treatment Plant Using Silver Nanoparticles on Activated Carbon)

  • 선용호
    • KSBB Journal
    • /
    • 제29권5호
    • /
    • pp.353-360
    • /
    • 2014
  • This study targets the pollutant removal of secondary effluent from final clarifiers in wastewater treatment plant using silver nanoparticles on activated carbon. The removal efficiency and treatment characteristics of pollutant are anlayzed by perfoming experiments using granular activated carbon with silver nanoparticles and ordinary granular activated carbon. The specific surface area of granular activated carbon with silver nanoparticles is smaller than that of ordinary granular activated carbon. However, the removal efficiency of $COD_{Mn}$, T-N and T-P in experiments using activated carbon with silver nanoparticles are higher than that in experiment using ordinary granular activated carbon. That means the case of activated carbon with silver nanoparticles is much better at treatment activity. In addition, activated carbon with silver nanoparticles has antimicrobial activity because there is no microbe on the surface of it after experiments.

코코넛 기반 활성탄 필터의 라돈 제거 효율 (Radon Removal Efficiency of Activated Carbon Filter from Coconut)

  • 안윤진;김기섭;김태환;김상록
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제46권2호
    • /
    • pp.141-149
    • /
    • 2023
  • The Korea Institute of Radiological and Medical Sciences plans to produce 225Ac, a therapeutic radio-pharmaceutical for precision oncology, such as prostate cancer. Radon, a radioactive gas, is generated by radium, the target material for producing 225Ac. The radon concentration is expected to be about 2000 Bq·m-3. High-concentration radon-generating facilities must meet radioactive isotope emission standards by lowering the radon concentration. However, most existing studies concerning radon removal using activated carbon filters measured radon levels at concentrations lower than 1000 Bq·m-3. This study measured 222Rn removal of coconut-based activated carbon filter under a high radon concentration of about 2000 Bq·m-3. The 222Rn removal efficiency of activated carbon impregnated with triethylenediamine was also measured. As a result, the 222Rn removal amount of the activated carbon filter showed sufficient removal efficiency in a 222Rn concentration environment of about 2000 Bq·m-3. In addition, despite an expectation of low radon reduction efficiency of Triethylenediamine-impregnated activated carbon, it was difficult to confirm a significant difference in the results. Therefore, it is considered that activated carbon can be used as a radioisotope exhaust filter regardless of whether or not Triethylenediamine is impregnated. The results of this study are expected to be used as primary data when building an air purification system for radiation safety management in facilities with radon concentrations of about 2000 Bq·m-3.

RESEARCH PAPERS : REMOVAL EFFICIENCY OF THE POLLUTANTS BY MULTILAYERED METAL TREATED CARBON FILTER

  • Oh, Won-Chun;Lee, Ho-Jin;Bae, Jang-Soon
    • Environmental Engineering Research
    • /
    • 제9권5호
    • /
    • pp.193-200
    • /
    • 2004
  • A study of the treatment of piggery wastes using a multilayered metal-activated carbon system followed by carbon bed filtration was carried out at bench scale. From the physicochemical properties obtained from samples treated with aqueous solutions containing metallic ions such as Ag$^+$, Cu$^{2+}$, Na$^{-}$, K$^+$ and Mn$^{2+}$, main inspections are subjected to isothem shape, pore distribution with micropore, SEM and EDX. Multilayered metal-activated carbons were contacted to waste water to inwestigate the simultaneous catalytic effect for the COD, BOD, T-N and T-P removal. From these removal performance was achieved. The high efficiency of the multilayered metal-activated carbon bed, satisfactory removal performance was achieved. The high efficiency of the multilayered metal-activated carbon bed was derermined by the properties of this material for trapping, catalytic effect and adsorption of organic solid particles.

Preparation of Composite Adsorbents by Activation of Water Plant Sludge and Phenolic Resin Mixtures

  • Myung, Heung-Sik;Kim, Dong-Pyo
    • Carbon letters
    • /
    • 제1권3_4호
    • /
    • pp.154-157
    • /
    • 2001
  • Composite adsorbents were prepared by mixing water plant sludge with phenolic resin having the ratio of 1 : 1, 1 : 2, and 1 : 3 respectively, curing from $100^{\circ}C$ to $170^{\circ}C$ under $N_2$ atmosphere, and then activating with $N_2$ at $700^{\circ}C$. Thermal property, specific surface area and morphology of the composite adsorbents as well as their precursors were measured by TGA, BET and SEM respectively. Removal efficiency of the composite adsorbents to ${NH_4}^+$ and TOC was compared with those of commercial zeolite and activated carbon. The adsorbents presented very promising TOC removal efficiency of 98%, which was identical level to that of commercial activated carbon while they displayed removal efficiency, only 32%, of ${NH_4}^+$. Therefore, this composite adsorbent considered as the alternative material of commercial activated carbon, used as an expensive removal agent of organic substances and THM in water treatment plant and it also suggested a possibility of practical application in other processes.

  • PDF

염화철 처리 활성탄에 의한 질산염 제거 (Nitrate Removal by $FeCl_3$-Treated Activated Carbon)

  • 정경훈;최형일;정오진
    • 한국환경보건학회지
    • /
    • 제27권1호
    • /
    • pp.63-68
    • /
    • 2001
  • A laboratory experiment was performed to invstigate the nitrate removal using FeCl$_3$ -treated activated carbon. Iron chloride(III) was coated onto the surface of activated carbon. The removal efficiency of nitrate was increased with increasing of FeCl$_3$ was used for coating material. About 22~26mg of Fe per unit g of activated carbon was adsorbed. The nitrate removal was not affected by the pH under the experiment range of pH, but the pH value in solution decrease to 3.5~4.0 after reaction. The removal efficiency of nitrate was increased with increasing of dosage of adsorbents. Ammonia was not detected and the Fe concentration as low as 0.22mg/$\ell$ was desorbed from the adsorbents. The adsorbents was regenerated using KCl solution, and recovery was 76.6% at 1 M of KCl. The adsorption of nitrate by FeCl$_3$-treated activated carbon followed the Freundlich isotherm equation and the Freundlich constant, 1/n, was 0.346. These results showed that the FeCl$_3$-treated activated carbon could serve as the basis of a useful nitrate removal.

  • PDF

Removal Efficiency of the Pollutants from Piggery Wastes with Activated Carbon Treated with Metal and Their Pilot Scale Design

  • Oh, Won-Chun;Park, Chong-Sung;Bae, Jang-Soon;Ko, Young-Shin
    • Carbon letters
    • /
    • 제7권3호
    • /
    • pp.180-187
    • /
    • 2006
  • The treatment of piggery wastes was carried out at pilot scale using a multilayered metal-activated carbon system followed by carbon bed filtration. The physicochemical properties were obtained from treated samples with aqueous solutions containing metallic ions such as $Ag^+$, $Cu^{2+}$, $Na^+$, $K^+$ and $Mn^{2+}$, which main obsevations are subjected to inspect surface properties, color removal properties by Uv/Vis and EDX. Multilayered metal-activated carbons were contacted with waste water to investigation of the simultaneous catalytic effect for the COD, BOD, T-N and T-P removal. The removal results for the piggery waste using multilayered metal-activated carbon bed was achieved the satisfactory removal performance under permitted values of Ministry of Environment of Korea. The high efficiency of the multilayered metal-activated carbon bed was determined by the performance of this material for trapping, catalytic effect and adsorption of organic solid particles.

  • PDF

Effect of Two-step Surface Modification of Activated Carbon on the Adsorption Characteristics of Metal Ions in Wastewater II. Dynamic Adsorption

  • Lee, Jae-Kwang;Park, Geun-Il;Ryu, Seung-Kon;Ki, Joon-Hyung
    • Carbon letters
    • /
    • 제4권1호
    • /
    • pp.14-20
    • /
    • 2003
  • Based on the previous results of the equilibrium and batch adsorptions, the removal efficiency of the two-step surface-modified activated carbon ($2^{nd}AC$) for heavy metal ions such as Pb, Cd, and Cr in fixed column was evaluated by comparing with that of the as-received activated carbon (AC) and the first surface-modified activated carbon ($1^{st}AC$). The order of metal removal efficiency was found as $2^{nd}AC$ > $1^{st}AC$ $\gg$ AC, and the efficiency of the $2^{nd}AC$ maintained over 98% from the each metal solution. Increase of the removal efficiency by the second surface modification was contributed to maintain favorable pH condition of bulk solution during adsorption process. The removal of the heavy metals on the $2^{nd}AC$ was selective with Pb being removed in preference to Cr and Cd in multicomponent solutions and slightly influenced by phenol as the organic material.

  • PDF

Influence of Nickel Electroplating on Hydrogen Chloride Removal of Activated Carbon Fibers

  • Park, Soo-Jin;Jin, Sung-Yeol;Ryu, Seung-Kon
    • Carbon letters
    • /
    • 제5권4호
    • /
    • pp.186-190
    • /
    • 2004
  • In this work, a nickel metal (Ni) electroplating on the activated carbon fiber (Ni/ACFs) surfaces was carried out to remove the toxic hydrogen chloride (HCl) gas. The surface properties of the treated ACFs were determined by using nitrogen adsorption isotherms at 77 K, SEM, and X-ray diffraction (XRD) measurements. HCl removal efficiency was confirmed by a gas-detecting tube technique. As a result, the nickel metal contents on the ACF surfaces were increased with increasing the plating time. And, it was found that the specific surface area or the micropore volume of the ACFs studied was slightly decreased as increasing the plating time. Whereas, it was revealed that the HCl removal efficiency containing nickel metal showed higher efficiency values than that of untreated ACFs. These results indicated that the presence of nickel metal on the ACF surfaces played an important role in improving the HCl removal over the Ni/ACFs, due to the catalytic reactions between nickel and chlorine.

  • PDF

유류오염 토양에서 발생되는 VOCs 제거를 위한 분변토의 활용 가능성에 관한 기초연구 (A Fundamental Study on the Application of Cast for Removal of VOCs Produced in the Oil-contaminated Soil)

  • 손희정;천미희;김철
    • 한국환경보건학회지
    • /
    • 제33권5호
    • /
    • pp.456-461
    • /
    • 2007
  • This study was carried out two point view that reuse of sludge and adsorption of benzene, toluene and o-xylene of VOCs in cast, carbonized cast and activated carbon. The cation exchange capacity of cast and carbonized cast were 59.2, 112 meq/100g, respectively. The specific surface were 560, $800m^2/g$, respectively. The average removal rates of benzene by 50g cast of 50% hydrous cast, anhydrous cast, carbonized cast, activated carbon were 15.0, 41.2, 88.2, 99.4% in 60min of retention time. The average removal efficiency of toluene by 50 g cast of 50% hydrous cast, anhydrous cast, carbonized cast, activated carbon were 12.5, 34.2, 88.2, 99.5% in 60 min of retention time. The average removal rates of o-xylene 50 g cast of 50% hydrous cast, anhydrous cast, carbonized cast, activated carbon were 8.8, 28.5, 84.8, 98.1% in 60min of retention time. The adsorption efficiency of test absorbent was in order of Activated Carbon > Carbonized Cast > Cast.

수중 과염소산염(Perchlorate) 제거를 위한 맞춤 분말활성탄 제조 (Manufacturing Tailored Powder Activated Carbon for Removing Perchlorate in Water)

  • 김상구;송미정;최근주;유평종;김신철;이용두
    • 대한환경공학회지
    • /
    • 제30권6호
    • /
    • pp.637-641
    • /
    • 2008
  • 이 연구는 과염소산염 제거를 위하여 정수처리장에서 적용 가능한 맞춤분말활성탄 제조와 활성탄 종류에 따른 제거효율 은 비교하기 위하여 수행하였다. Cetyltrimethylammoniumchloride(CTAC)를 이용하여 활성탄에 흡착 전처리하면 과염소산염을 효과적으로 제거 할 수 있었다. 10,000 mg/L 맞춤분활성탄은 농도 5,000 mg/L CTAC 용액 500 mL에 5 g의 분말활성탄을 혼합하여 제조하였다. 맞춤분말활성탄을 이용하면 일반 분말활성탄에 비해 10 이상 높은 과염소산염 제거가 가능하였다. 맞춤 분말활성탄을 이용하여 과염소산염 제거 시 초기 접촉시간 15분은 접촉시간에 따라 잔류 과염소산염의 농도가 줄어들었으나 15분 이후에는 잔류농도의 변화가 거의 없었다. 맞춤분말활성탄 조제 시 활성탄의 요오드가에 따라서 과염소산염 제거능이 달랐는데 요오드가 1,083 mg/g 활성탄은 요오드가 944 mg/g 활성탄에 비해 4배 이상 높은 과염소산염 제거능을 보였다. 일반적으로 정수장에서 주입 가능한 분말활성탄 농도인 5 mg/L 범위의 맞춤분말활성탄 주입농도에서 50 $\mu$g/L의 과염소산염 농도를 15 $\mu$g/L까지 저감 가능하였다.