• Title/Summary/Keyword: activated carbon fiber

Search Result 239, Processing Time 0.025 seconds

Adsorption/desorption of CO2 on Activated Carbon Fibers Using Electric Swing Adsorption (활성탄소섬유상에서 전기변동법을 이용한 CO2의 흡/탈착)

  • Shim, JaeWoon;Moon, SeungHyun
    • Korean Chemical Engineering Research
    • /
    • v.43 no.3
    • /
    • pp.432-437
    • /
    • 2005
  • An electric swing adsorption (ESA) process for recovering highly pure $CO_2$ from the mixed gases was tested. In this study, activated carbon fibers were used as an adsorbent. The activated carbon fibers showed fast adsorption rate and the high adsorption capacity for $CO_2$ adsorption under the condition of the ambient pressure. Activated carbon fiber with higher specific surface area was suitable to repeated adsorption-desorption cycle process, showing consistent breakthrough curve. Especially, the regeneration method by vacuum combined with ESA improved the performance of desorption process by an additional 17% regeneration efficiency compared to a vacuum only method, and showed the high regeneration efficiency at comparatively low 7-8 Wh energy.

Adsorption Characteristics of Volatile Organic Compounds-BTX on Activated Carbon Fiber (활성탄소섬유를 이용한 휘발성유기화합물 (VOCs-BTX)의 흡착특성)

  • 김한수;박영성
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.15 no.6
    • /
    • pp.805-812
    • /
    • 1999
  • Adsorption characteristics of volatile organic compounds(VOCs) by activated carbon fiber(ACF) were investigated using a continuous system for benzene, toluene, xylene(BTX) generation. Studied characteristics for adsorption were equilibrium capacity, accumulative adsorption, and breakthrough curve. Operating variables were adsorption temperature(25~45$^{\circ}C$) and partial pressure(1.2~12 mmHg) of BTX. The experimental results show that the adsorption equilibrium capacity increases with increasing partial pressure of BTX and decreases with increasing temperature. It was also found that the break point was decreased with increasing partial pressure, temperature and gas flow rate due to an effect of mass transfer of adsorbate.

  • PDF

Equilibria and Dynamics of Toluene and Trichloroethylene onto Activated Carbon Fiber

  • Park, Jee-Won;Lee, Young-Whan;Choi, Dae-Ki;Lee, Sang-Soon
    • Clean Technology
    • /
    • v.8 no.2
    • /
    • pp.93-99
    • /
    • 2002
  • Adsorption dynamics for toluene and trichloroethylene with an isothermal fixed bed of activated carbon fiber were investigated. Equilibrium isotherms were measured by a static method for toluene and trichloroethylene onto activated carbon fiber at temperatures of 298, 323, and 348 K and pressure up to 3 kPa for toluene and 6 kPa for trichloroethylene, respectively. These results were correlated by the Toth equation. And dynamic experiments in an isothermal condition of 298 K were examined. Breakthrough curves reflected the effects of the experimental variables such as partial pressures for adsorbate and interstitial bulk velocities of gas flow. To present the column dynamics, a dynamic model based on the linear driving force (LDF) mass transfer model was applied.

  • PDF

Thermal Characteristics Analysis of Pre-Treated Rayon Fibers for Preparing Activated Carbon Fibers (활성탄소섬유 제조시 전처리된 레이온 섬유의 열특성 분석)

  • Choi, Sang Seun;Lee, Soon Hong
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.4
    • /
    • pp.61-72
    • /
    • 2014
  • The aim of this study is to define the condition of optimal pre-treatment for preferable activated carbon fibers (ACFs), which are based on rayon fibers. This paper shows the ideal path of ACFs preparation process; implies that rayon fibers are pre-treated by various solvents with different times before the heating process. The pre-treated rayon fibers finally turned into desirable rayon fiber-based ACFs through optimal pre-treatment condition by heating processes. The thermal analysis method of pre-treated rayon fibers by thermo-gravimetry analyser (TGA) is an idealized tool, which analyzes the best thermal condition of pre-treatment process. Surface morphologies of resulting rayon fibers based ACFs were examined by scanning electron microscope(SEM). The results of TGA and SEM analyses show that the optimal pre-treatment condition for preparing ACFs was clearly defined, in terms of thermal stability and surface morphology.

Properties and Photocatalytic Activity of Pitch-binded ACF/TiO2Composites

  • Oh, Won-Chun;Jung, Ah-Reum
    • Journal of the Korean Ceramic Society
    • /
    • v.45 no.3
    • /
    • pp.150-156
    • /
    • 2008
  • Pitch-binded activated carbon fiber(ACF)/$TiO_2$ composite photocatalysts were prepared by Carbon Tetra Chloride (CTC) solvent mixing method with different mixing ratios of anatase to ACF. The result of the textural surface properties demonstrated that there is a slight increase in the Brunauer, Emmett and Teller (BET) surface area of composites with an increase of the amount of ACF. The surfaces structure morphologies of the composites were observed using an Scanning Electron Microscope (SEM). In the XRD patterns for all ACF/$TiO_2$ composites, the diffraction peaks showed the formation of anatase crystallites. The EDX spectra showed the presence of C, O and Si with strong Ti peaks. Most of these samples were richer in carbon and major Ti metal than any other elements. From the photo-decomposition results, the excellent activity of the ACF/$TiO_2$ composites between c/$c_0$ for methylene blue and UV irradiation time could be attributed to both the effects of the photocatalysis of the supported $TiO_2$ and adsorptivity of activated carbon fiber and another carbon derived from pitch.

Preparation and properties of antibacterial activated carbon fiber (항균성 탄소섬유의 제조와 특성)

  • 오원춘;김범수;임창성;장원철
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.12 no.4
    • /
    • pp.165-171
    • /
    • 2002
  • The study on the adsorption, the surface properties and the antibacterial effects of the metal-treated pitch based activated carbon fibers was carried out. From the adsorption studies on the series of metal-treated activated carbon fiber, the specific surface areas of the metal treated activated carbon fiber obtained from BET equation were in the range of 113.2~1574 $m^2$/g for the Ag-ACFs. And that of Cu treated ACF are distributed to 688.2-887.8 $\m^2$/g. And, the specific surface areas of the Ni-treated pitch based ACFs were in the range of 692.6~895.2 $\m^2$/g. From the ${\alpha}_s$- method, 0.06~1.1 cm^3/g of the micropore volumes were obtained from Ag-ACFs. And, 0.1~0.2 cm^3/ and 0.2~0.6 cm^3/g of the micropore volumes were obtained from Cu and Ni-ACFs, respectively. And, from the SEM morphology results, it was observed that the surface of activated carbon fiber are partially blocked and coated by metal after the treatment. Finally, from the antibacterial effects of metal-treated activated carbon fiber against E. coli, the areas of antibacterial effect become larger with the increase in mole ratio of metal treated. And, from the antibacterial effects using Shake flask method against E. coli, the percentage of the effects was 92.5~100 % and the antibacterial effect was increased with the increase in mole concentration of metal treated.

Adsorption Characteristics of a Respirator Cartridge for Organic Vapor Packed with Activated Carbon Fiber (활성탄소섬유가 충전된 유기가스용 방독마스크 정화통의 흡착특성)

  • Shin, Chang-Sub;Kim, Ki-Hwan;Kang, Young-Goo
    • Journal of the Korean Society of Safety
    • /
    • v.15 no.2
    • /
    • pp.84-91
    • /
    • 2000
  • The adsorption characteristics of a respirator cartridge is affected by the kind of adsorbent, concentration of organic vapor, humidity and packing density of cartridge. In this study, activated carbon fiber(ACF) instead of activated carbon is used as a adsorbent of cartridges for the removement of organic vapor and the adsorption characteristics were examined. ACF made of cellulose showes high efficiency for the removal of carbon tetrachloride and the adsorption capacity was 0.569g/g ACF at 450 ppm. The relative humidity dose not affected to the adsorbed amount and Langmuir Isotherm was more adequate than Freundlich Isotherm for this adsorption phenomena.

  • PDF

Carbon dioxide (CO2) concentrations and activated carbon fiber filters in passenger vehicles in urban areas of Jeonju, Korea

  • Kim, Hong Gun;Yu, Yunhua;Yang, Xiaoping;Ryu, Seung Kon
    • Carbon letters
    • /
    • v.26
    • /
    • pp.74-80
    • /
    • 2018
  • The South Korean Ministry of the Environment has revised the laws relating to the management of interior air quality for multiple use facilities, and recommends maintaining carbon dioxide ($CO_2$) concentration in passenger vehicles below 1000 ppm during operation in urban areas of large cities. However, the interior $CO_2$ concentration of passenger vehicles can rapidly increase and exceed 5000 ppm within 30 min, as observed when two passengers are traveling in urban areas of the South Korean city of Jeonju with the air conditioner blower turned off and the actuator mode set to internal circulation mode. With four passengers, $CO_2$ concentration can reach up to 6000 ppm within 10 min. To counter this, when the actuator is set to external mode, $CO_2$ concentration can be maintained below 1000 ppm, even after a long period of running time. As part of the air conditioning system, alkali-treated activated carbon fiber filters are considered to be far superior to the commercial non-woven filters or combination filters currently commonly in use.