• 제목/요약/키워드: activate sludge process

검색결과 7건 처리시간 0.016초

Domestic Sewage Treatment with a Successive System of Activated Sludge Process and Phytoplankton Cultivation

  • Hong, W.H.;Pack, M.Y.
    • 한국미생물생명공학회:학술대회논문집
    • /
    • 한국미생물생명공학회 1978년도 추계학술대회
    • /
    • pp.209.1-209
    • /
    • 1978
  • Treatment of domestic sewage discharged from big cafeteria kitchen, especially rice-washing water, was examined by the use of activated sludge process and phytoplankton cultivation. Only with a activated sludge process COD value decreased from around 1000 mg/ι to 100 mg/ι, but nutrients, such as nitrogen and phosphate could not be removed sufficiently phytoplankton cultivation in combination with a activate sludge process could decrease COD value down to 50 mg/ι and nutrients values were also reduced substantially. However, the initial concentration of 20 mg/ι in the rice-washing water could not be removed completely without addition of activated sludge as a nitrogen source.

  • PDF

혐기-호기 활성슬러지법에 의한 유량변동이 있는 폐수의 N-P 동시 제거에 관한 연구(I) (Simultaneous N-P Removal of Wastewater with Flow Variation by Anaerobic-Aerobic Activated Sludge Process(I))

  • 이민규;서근학
    • 한국환경과학회지
    • /
    • 제4권5호
    • /
    • pp.509-516
    • /
    • 1995
  • The treatment performances of anaerobic-aerobic activated sludge process were investigated under various operation conditions. The treatment system proposed in this study gave a relatively stable performance against hourly change of the flow rate and showed a satisfactory removal of nitrogen and phosphorus compounds under experimental conditions. The recycle ratio of mixed liquor from aerobic to anaerobic region and peak coefficient primarily controlled the extent of nitrogen removal. The recycle ratio had the optimum values which were determined by the microbial activities of nitrification and denitrification. The behavior of the treatment unit could be simulated by using the kinetic equations and reactor models which considered the treatment units as complete mixing tanks.

  • PDF

혐기-호기 활성슬러지법에 의한 유량변동이 있는 폐수의 N-P 동시 제거에 관한 연구(I) (Simultaneous N-P Removal of Wastewater with Flow Variation by Anaerobic-Aerobic Activated Sludge Process(I))

  • 이민규;서근학
    • 한국환경과학회지
    • /
    • 제4권5호
    • /
    • pp.123-123
    • /
    • 1995
  • The treatment performances of anaerobic-aerobic activated sludge process were investigated under various operation conditions. The treatment system proposed in this study gave a relatively stable performance against hourly change of the flow rate and showed a satisfactory removal of nitrogen and phosphorus compounds under experimental conditions. The recycle ratio of mixed liquor from aerobic to anaerobic region and peak coefficient primarily controlled the extent of nitrogen removal. The recycle ratio had the optimum values which were determined by the microbial activities of nitrification and denitrification. The behavior of the treatment unit could be simulated by using the kinetic equations and reactor models which considered the treatment units as complete mixing tanks.

무산소조에서 고농도 미생물을 이용한 하수고도처리공정의 처리특성 (Characteristics of Advanced Wastewater Treatment Process Using High MLSS in Anoxic Tank)

  • 손동훈;임봉수;박혜숙
    • 한국물환경학회지
    • /
    • 제20권1호
    • /
    • pp.42-47
    • /
    • 2004
  • This study was accomplished to develope an advanced wastewater treatment process using high MLSS in anoxic tank aimed to improve nutrient removal and to reduce wasting sludge. It was operated with 4 Modes with varing solid concentration and internal recycle ratios. Mode I, II, III was operated 1.0~1.5% MLSS concentration at anoxic tank with 50% sludge recycle rate, however, each internal recycle rate were 100%, 200%, 300% and Mode IV was operated 1.5~2.0% MLSS concentration at anoxic tank with 50% sludge recycle rate and 100% internal recycle rate. The COD removal efficiency didn't show any big difference from Mode I to IV. The average COD removal rate was over than 90%. The T-N removal rate was 73%, the highest rate in all mode. The 36% of SCOD is used for the denitrification and phosphorus release in the anoxic tank. Specific denitrification rate was 3.5mg $NO_3{^-}-N/g$ Mv/hr and denitrification time was 0.7hr. As MLSS concentration is higher in anoxic tank as denitrification time would be shorter. The T-P removal rate was average 70%. The phosphorus release accomplished from the anoxic tank because the anaerobic condition was prevalent in the anoxic due to the prompt completion of denitrification. Sludge production was 0.28 kgVSS/kg $BOD_{removed}$ under the 1.5% MLSS and 17 day SRT. It is prominent result which has 40% sludge reduce comparing with traditional activate sludge system.

알루미늄 부식을 조합한 간헐폭기 활성슬러지 공정에서 질소와 인의 동시 제거 (Simultaneous Removal of Phosphorus and Nitrogen by Intermittently Aerated Activate Sludge combined with Aluminum Corrosion)

  • 정경훈;최형일;정오진;박상일;김우항
    • 한국환경과학회지
    • /
    • 제14권7호
    • /
    • pp.675-681
    • /
    • 2005
  • A laboratory experiment was performed to investigate phosphorus and nitrogen removal from synthetic wastewater by intermittently aerated activated sludge process packed with aluminum and silver plate. Three continuous experi­mental processes, i. e. an intermittently aerated activated sludge process(Run A), an intermittently aerated activated sludge process with an aluminum and silver plate packed into the reactor(Run B), and a reactor post stage(Run C) were compared. In the batch experiments, the phosphorus removal time in the reactor packed with aluminum and silver plate simultaneously was faster than that of the reactor packed with only an aluminum plate. More phos­phorus was removed with an increase of NaCl concentration. The pitting corrosion of aluminum does not affect the performance of the biological treatment. The total nitrogen removal efficiency in Run B was $57\%\;and\;43.6\%$ at the HRT of 12 and 6 hours respectively. The effluent $PO_{4-}P$ concentration as low as 1.0 mg/L could be ob­tainable through the continuous experiment in Run B at HRT of 6 hours.

접촉담화공정에 의한 폐수처이에 있어서의 제한요권에 관한 연구 (A Study on the Limiting Factors in Wastewater Treatment by Contact Oxidation Process)

  • 황상용;손종열;우완기
    • 환경위생공학
    • /
    • 제5권2호
    • /
    • pp.45-52
    • /
    • 1990
  • This study is to discuss limiting factors influenced on the removal efficiency of organic materials investigated using the polypropyrene biofilter which appropriate to attach micro-organism in order to apply the contact oxidation proce,:5. The results obtained in the experiment were as follows : 1. In the range o: pH 4.0~ 12.0 was obtained the removal efficiency of COD higher than 85% It was proved that variation of pH(4.0 ~ 12.0) was nothing to do with the removal efficiency of substrate in continuous reactor. 2. Temperature to obtain removal efficiency of COD higher than 85% was $10^{\circ}$ ~$40^{\circ}$. Removal efficiency of COD was no less than those at high temperature if MLVSS concentration was maintained 8,000~ 15,000 m/1. 3. In the continuous reactor, the volumetric loading of COD for removal efficiency higher than 95% had to be 0.5~1.5 kg COD/.d below. And then the HRT was Bhrs. 4. In comparison with the conventional activate sludge process, the contact oxidation process was excellent in removal efficiency, sludge production rate and maintenance.

  • PDF

가변형 간벽을 이용한 SBR 공정의 실증 Pilot 연구 (Positive Pilot Research of SBR Process with Flexible Vertical)

  • 김만수;박종운;박철휘
    • 대한환경공학회지
    • /
    • 제27권4호
    • /
    • pp.438-444
    • /
    • 2005
  • 본 연구에서는 가변형 간벽을 설치하고 이 가변형 간벽의 열고 닫음에 따라 하나의 SBR 반응조를 시간적으로 뿐만 아니라 공간적으로도 분리시킴으로써 aerobic, anaerobic 또는 anoxic 상태의 구분을 명확히 하여 탈질 및 탈인 효율을 증대시켰다. 본 연구 결과 $COD_{Cr}$/N ratio 10($BOD_5$/N ratio 5) 정도의 실 플랜트 조건에서 T-N 및 T-P 제거효율은 90.9%와 75%를 나타내었다. 또한 잉여슬러지내 인 함유량 조사결과 기존 처리장에서 발생된 잉여슬러지의 인 함량비율을 100%라 할 때 pilot plant에서 발생된 잉여슬러지의 인 함유율은 생 슬러지의 경우 133.6%, 건조 슬러지의 경우 124.3%로서 기존 처리장의 슬러지내 인 함유율보다 $25{\sim}30%$ 정도 높은 것으로 조사되었다. 따라서 SBR반응조 내에 가변형 간벽을 설치함으로서 명확한 탈질 탈인을 위한 반응조건을 제시해 줄 수 있는 것으로 나타났다.