• 제목/요약/키워드: acryl

검색결과 385건 처리시간 0.035초

상전이 마이크로캡슐 재료의 축열특성 (The characteristics of microencapsulated phase-change materials)

  • 임대우
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2003년도 춘계학술발표대회 논문집
    • /
    • pp.53-56
    • /
    • 2003
  • The objective of this research is to investigate the thermal behavior of microencapsulated phase-change materials(MEPCM), and a shell of melamine-formaldehyde. These PCM materials were tested using DSC and thermal data station. Fabrics with enhanced thermal properties were prepared by padding the fabrics with the microcapsules containing PCM and acryl binder. The rate of temperature increase was significantly decreased as the amount of MEPCM added on the surface of the fabrics increased.

  • PDF

고로슬래그 미분말의 치환율 변화에 따른 제치장 콘크리트의 표면광택 특성 (Properties of Surface Grossing of Exposed Concrete with the Contents of Blast Furnace Slag)

  • 전충근;김효구;김정진;김기철;한천구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 가을 학술발표회 논문집(II)
    • /
    • pp.911-914
    • /
    • 2000
  • Surface glossing and physical properties of exposed concrete varied with blast furnace slag content are dsicussed in this paper. According to experimental results, as the content of blast furnace slag increases, concrete gains high strength moderately at later stage and surface glossing increase. It shows that glossing decrease with age. Surface glossing shows high as W/B decreases and surface coating is applied. Concrete according to form type shows good results in surface glossing in order for acryl form, fancy form and steel form.

Flexible OTFT-Backplane for Active Matrix Electrophoretic Display Panel

  • Lee, Myung-Won;Song, Chung-Kun
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2007년도 7th International Meeting on Information Display 제7권1호
    • /
    • pp.159-161
    • /
    • 2007
  • We fabricated flexible OTFT-backplanes for the electrophoretic display(EPD). The OTFTs employed bottom contact structure on PEN substrate and used the cross-linked polyvinylphenol for gate insulator, pentacene for active layer. Especially, we used PVA/Acryl double layers for passivation of backplane as well as for pixel dielectric layer between backplane and EPD panel. The OTFT-EPD panel worked successfully anddemonstrated to display some patterns.

  • PDF

사지(四肢) 단순촬영조건(單純撮影條件)의 관전압(管電壓)에 대(對)한 연구(硏究) (A Study on Kilovoltage in Radiographic Technique Factors of the Extremities)

  • 최종학;전만진;김영일
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제3권1호
    • /
    • pp.29-35
    • /
    • 1980
  • The tube voltage in radiographic technique factors of the extremities was studied to use the acryl phantom and aluminum step wedge. It was the proper tube voltage that was over 55-60kV in the finger, over 65kV in the forearm and over 75kV in the knee joint.

  • PDF

Structural Properties of polyaniline blended with PNIPAM

  • Neupane, Kosh-Prasad;Ha, Jin-Wook
    • 한국산학기술학회:학술대회논문집
    • /
    • 한국산학기술학회 2003년도 춘계학술발표논문집
    • /
    • pp.334-336
    • /
    • 2003
  • Polyaniline(PANi) composite panicles were synthesized by chemical oxidation polymerization of aniline in presence of Poly-N-Isopropyl acryl amide(PNIPAM). The PANi panicles are formed in the reaction medium deposited onto non-conducting PNIPAM template to produce PANi-coated composite panicles. The formation of composite was confirmed by FT-IR spectroscopy, and UV-VIS spectroscopy, and their morphological structures were examined by scanning electron microscopy(SEM). From the experimental results, it was determined that PANi was successfully coated onto non-conducting PANIPAM.

  • PDF

투시 조영 검사 시 환자 선량 관리를 위한 진단참고선량 구축에 관한 연구 (UGI, Esophagography 기준) (Fluoroscopy examinations for the management of patient dose study on the establishment of diagnostic reference level (UGI, Esophagography standards))

  • 홍선숙;박은성;조준영;성민숙;양한준
    • 대한디지털의료영상학회논문지
    • /
    • 제14권1호
    • /
    • pp.1-6
    • /
    • 2012
  • This round of tests in patients with UGI and Esophagography data collected by national and international reference levels based on the original set of guidelines and fluoroscopy, through the provision of medical radiation exposure reduction and further optimization of Defense to realize that is intended. 359 names in our hospital underwent Esophagography 302 patients who underwent UGI average fluoroscopy time and number of images to calculate the average 21 cm Acryl phantom dose for 10 seconds and 20 seconds, average area dose and the area dose of 1 spot image, 5 spot consecutive images by measuring the patient dose and third quartile of the mean area dose was set seonryangin reference dose. Esophagography average patient dose was set to 30.05 $Gy{\cdot}cm^2$, DRL was set at a 25.37 $Gy{\cdot}cm^2$. Average dose of UGI patients were selected as 45.33 $Gy{\cdot}cm^2$, DRL was set at a 34 $Gy{\cdot}cm^2$. UGI patients with established average dose recommended in the 2008 national recommendation from the UGI examination with a dose of less than 49.7 $Gy{\cdot}cm^2$ seonryangin is evaluated. This Note examines the dose of self-aware through education recognizes the importance of dose reduction and examine if their efforts and further reduce patient dose could achieve optimization of the medical exposure is considered.

  • PDF

초음파 감쇠가 원형관의 공명 산란에 미치는 영향 (The Effects of Material Attenuation on Acoustic Resonance Scattering from Cylindrical Tubes)

  • 이종포;최명선;주영상;임형택
    • 비파괴검사학회지
    • /
    • 제14권1호
    • /
    • pp.23-31
    • /
    • 1994
  • 재회의 초음파 감쇠가 유체속의 원형관으로부터의 공명 산란 특성에 미치는 영향을 분석하였다. 이를 위하여, 실수 파수 대신에 복소수의 허수부가 초음파 감쇠를 나타내는 복소수 파수(complex wave numbers)를 도입하였다. 유체가 들어있는 원형관에 대해 재료의 감쇠를 고려했을 때, 연속 평면파에 의한 물속에서의 공명 산란 특성을 분석하는 수치 해석 프로그램을 완성하였다. 프로그램의 타당성을 검증하기 위하여 감쇠를 무시한 경우의 수치 해석 결과를 기 보고된 수치 해석 결과와 비교하였다. 알루미늄 및 아크릴 원형관의 감쇠가 이들 원형관의 산란 특성에 미치는 영향을 해석한 결과, 공명피크의 폭이 좁고 예리할수록, 또한 $k_{1{\alpha}}$가 클수록 감쇠의 영향이 뚜렷하였다. 원형관의 공명 산란 특성이 초음파 감쇠에 크게 좌우되었다.

  • PDF

흉부 고관전압 촬영에 있어서의 늑골음영과 폐문리의 시각적 평가 (Visual Evaluation of Rib Shadow and Lung Marking during High-voltage Chest Radiography)

  • 최권규;이창엽;신동식;김창남;최기영;허준
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제15권1호
    • /
    • pp.99-105
    • /
    • 1992
  • Visual evaluation of rib shadow and lung marking during high voltage chest radiography. The Purpose of this study is to improvement of visual discrimination of pulmonary structures on the conventional chest radiogram. The author prepared an artificial lung using an acryl plate, 8 cm in thickness, which is nearly equivalent to human lung, and 0.6 cm thickness of an aluminum plate for an artificial rib, and 0.5 cm of an acryl plate as a pulmonary vessel as well. And they were used as objects for experimental radiograms. This study performed with gradual increasing densities of film bases in the sequences of densities of 0.6, 0.9, 1.1 and 1.3. We made two combinations of images after multiple and regular cuts, with width of 1 cm, of 4 radiograms at the above mentioned densities of film bases. One image consisted of alternative combination of radiograms taken at densities of 0.6 and 1.3, and the other did at 0.9 and 1.1. The latter image provided better visual perception of pulmonary structures than the former. Experimental radiograms were also taken with 60 kV and 120 kV respectively. After careful evaluation and comparison to images taken on varieties of different densities with combinations and kV, the author had a conclusion that it is advisable to use a high kV X-ray which makes rib shadow subtle, for better visual delineation of pulmonary structures behind ribcage, eventhough contrast of pulmonary structures are decreased at high kV radiogram.

  • PDF

지하매설 가스배관의 가스 누출시 지하 확산거동에 관한 연구 (A Study on the Diffusion Behavior of Leak Gas from Underground Gas Pipeline)

  • 최송천;조영도;김교선
    • 한국가스학회지
    • /
    • 제3권2호
    • /
    • pp.43-52
    • /
    • 1999
  • 지하에 매설된 도시가스 배관에서의 누출 가스에 대한 확산 거동을 관찰하기 위하여 지중 확산실험조를 제작하여 실험하였다. 실험조는 도시가스 공급위치와 농도의 측정위치를 변화시킬 수 있도록 acryl로 제작하였으며, MOS 센서를 이용하여 도시가스 농도를 측정하였다. 가스의 지하 확산을 측정하기 위한 토질로서 주문진 표준사와 화강풍화토를 이용하였으며, 가스누출 속도 변화에 따른 도시가스 농도 변화를 시간에 따라 측정하였다. 누출점으로부터 센서의 측정위치가 가까울수록 또는 누출 속도가 증가할수록 가스의 감지시간이 감소하였으며, 누출가스 농도의 빠른 증가로 인하여 정상상태시 높은 농도를 나타내었다. 또한, 주문진 표준사보다 다짐에 의해 밀도가 증가한 화강풍화토에서 초기에 농도가 낮게 측정되었으나, 시간이 지남에 따라 농도가 높게 나타났다.

  • PDF