• 제목/요약/키워드: acoustic transducer

검색결과 393건 처리시간 0.023초

전자기 초음파를 이용한 CFRP 복합적층판의 적층배향 특성평가에 관한 연구 (A Study on Characterization for Stacking Fault Evaluation of CFRP Composite Laminates Using an EMAT Ultrasonics)

  • 임광희;나승우;김지훈;이창노;;양인영
    • 한국자동차공학회논문집
    • /
    • 제13권2호
    • /
    • pp.83-92
    • /
    • 2005
  • An electromagnetic acoustic transducer (EMAT) is a unique probe that does not require a couplant or gel and also can usually generate or detect an ultrasonic wave into specimens across a small gap. It, therefore can be applied in a noncontact mode with a high degree of reproducibility. Especially stiffness of composites depends on layup sequence of CFRP(carbon fiber reinforced plastics) laminates. It is very important to evaluate the layup errors in prepreg laminates. A nondestructive technique can therefore serve as a useful measurement for detecting layup errors. This shear wave for detecting the presence of the errors is very sensitive. A decomposition model has been used in the interpretation and prediction of test results. Test results have been com pared with model data. It is found that the high probability shows between tests and the model utilized in characterizing cured layups of the laminates. Also a C-scan method was used for detecting layup of the laminates because of extracting fiber orientation information from the ultrasonic reflection caused by structural imperfections in the laminates. Therefore, it was found that interface C-scan images show the fiber orientation information by using two-dimensional fast Fourier transform (2-D FFT).

엑시며 레이저 펄스에 의해 여기된 광음향신호 분석 (An Analysis of Photoacoustic Signals Excited by Excimer Pulsed Laser)

  • 이종오;전계석
    • 한국음향학회지
    • /
    • 제16권1호
    • /
    • pp.39-46
    • /
    • 1997
  • 본 논문에서 XeF, KrF 엑시머레이저 펄스에 의해 금속에서 여기되는 광음향신호를 PZT 변환기로 검출하여 광음향 변환 메카니즘과 지향성패턴을 분석하였다. 고체에서 레이저펄스에 의한 광음향 변환 매카니즘은 조사되는 레이저의 에너지밀도에 따라 열탄성영역과 플라즈마영역으로 나뉘며 두영역에서 서로 다른 양상을 보인다. 열탄성영역에서는 표면과 수평방향의 변위가 크고 플라즈마영역에서는 반사력으로 인해 수직방향의 변위가 크게 나타나는 것으로 모델링되며 이를 중심파장 480nm의 XeF엑시머레이저와 248nm의 KrFdprtlajfp이저를 사용하여 실험적으로 증명하였다. 또한 열탄성 영역에서 최대종파에너지는 $60^{\circ}$, 최대횡파에너지는 $30^{\circ}$부른에서 나타났고 플라즈마영역에서는 최대 종파와 횡파에너지가 각각 $0^{\circ},\;30^{\circ}$부근에서 나타나는 지향특성을 보였다.

  • PDF

초음파의 매질 투과성을 이용한 시추공 케이싱 배면의 암상 및 절리구조 조사 연구 (Use of Ultrasonic beam transmissivity for investigating the structural features in plastic pipe cased borehole)

  • 김중열;김유성
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.751-758
    • /
    • 2002
  • Boreholes that are drilled in soft or unconsolidated materials such as gravels and coals are prone to collapse. To maintain the hole, some kinds of casing pipes are needed. If thereby a plastic pipe e.g. PVC is used for the casing, Televiewer tool is still capable of detecting structural features such as fractures in the borehole wall behind the pipe, whereas other borehole-imaging logging devices such as BIPS (Borehole Image Processing System) and FMS(Formation Micro Scanner) won't provide any information about that. Televiewer's primary component is a piezoelectric transducer centered in the hole. It acts as both a transmitter and receiver, and sends an ultrasonic beam. That is reflected, in the same manner as the seismic wave propagation, from the both sides(inner and outer surfaces) of the casing pipe, transmits through the pipe and then reflected from the borehole wall. With an appropriate choice of time-windowing, it is possible to capture the returning signals from both the borehole wall and the outer side of casing pipe as well. A suite of laboratory tests were performed on various physical models composed of plastic pipes with different diameters. Although the amplitudes of returning signals were reduced to about half the usual value due to the transmission loss, the dynamic range of Televiewer tool was sufficient to observe the structural features behind the casing pipe. Besides, several representative case studies at various research areas in our country are presented. The results demonstrate the usefulness of the transmissivity of Televiewer acoustic km, which will assist in further structural interpretation.

  • PDF

Feasibility Study on the Utilization of EMAT Technology for In-line Inspection of Gas Pipeline

  • Cho, Sung-Ho;Yoo, Hui-Ryong;Rho, Yong-Woo;Kim, Hak-Joon;Kim, Dae-Kwang;Song, Sung-Jin;Park, Gwan-Soo
    • Journal of Magnetics
    • /
    • 제16권1호
    • /
    • pp.36-41
    • /
    • 2011
  • If gas is leaking out of gas pipelines, it could cause a huge explosion. Accordingly, it is important to ensure the integrity of gas pipelines. Traditionally, over the years, gas-operating companies have used the ILI system, which is based on axial magnetic flux leakage (MFL), to inspect the gas pipelines. Relatively, there is a low probability of detection (POD) for the axial defects with the axial MFL-based ILI. To prevent the buried pipeline from corrosion, it requires a protective coating. In addition to the potential damage to the coating by environmental factors and external forces, there could be defects on the damaged coating area. Thus, it is essential that nondestructive evaluation methods for detecting axial defects (axial cracks, axial groove) and damaged coating be developed. In this study, an electromagnetic acoustic transducer (EMAT) sensor was designed and fabricated for detecting axial defects and coating disbondment. In order to validate the performances of the developed EMAT sensor, experiments were performed with specimens from axial cracks, axial grooves, and coating disbondment. The experimental results showed that the developed EMAT sensor could detect not only the axial cracks (minimum 5% depth of wall thickness) and axial grooves (minimum 10% depth of wall thickness), but also the coating disbondment.

Photoacoustic imaging of occlusal incipient caries in the visible and near-infrared range

  • da Silva, Evair Josino;de Miranda, Erica Muniz;de Oliveira Mota, Claudia Cristina Brainer;Das, Avishek;Gomes, Anderson Stevens Leonidas
    • Imaging Science in Dentistry
    • /
    • 제51권2호
    • /
    • pp.107-115
    • /
    • 2021
  • Purpose: This study aimed to demonstrate the presence of dental caries through a photoacoustic imaging system with visible and near-infrared wavelengths, highlighting the differences between the 2 spectral regions. The depth at which carious tissue could be detected was also verified. Materials and Methods: Fifteen permanent molars were selected and classified as being sound or having incipient or advanced caries by visual inspection, radiography, and optical coherence tomography analysis prior to photoacoustic scanning. A photoacoustic imaging system operating with a nanosecond pulsed laser as the light excitation source at either 532 nm or 1064 nm and an acoustic transducer at 5 MHz was developed, characterized, and used. En-face and lateral(depth) photoacoustic signals were detected. Results: The results confirmed the potential of the photoacoustic method to detect caries. At both wavelengths, photoacoustic imaging effectively detected incipient and advanced caries. The reconstructed photoacoustic images confirmed that a higher intensity of the photoacoustic signal could be observed in regions with lesions, while sound surfaces showed much less photoacoustic signal. Photoacoustic signals at depths up to 4 mm at both 532 nm and 1064 nm were measured. Conclusion: The results presented here are promising and corroborate that photoacoustic imaging can be applied as a diagnostic tool in caries research. New studies should focus on developing a clinical model of photoacoustic imaging applications in dentistry, including soft tissues. The use of inexpensive light-emitting diodes together with a miniaturized detector will make photoacoustic imaging systems more flexible, user-friendly, and technologically viable.

파라메트릭 어레이를 이용한 공기 중 디지털 통신 연구 (A Study on Digital Communication in Air Using Parametric Array)

  • 제엽;이재일;이종현;문원규
    • 한국음향학회지
    • /
    • 제28권8호
    • /
    • pp.768-773
    • /
    • 2009
  • 본 논문에서는 파라메트릭 어레이를 이용한 공기 중 디지털 통신의 특성을 측정해 보았다. 2차 오더의 비선형 현상인 파라메트릭 어레이를 구현하기 위하여, 고출력, 고효율의 음파 발생이 가능한 요철 트랜스듀서가 사용되었다. 1차 음파 (primary wave)의 주파수는 트랜스듀서 공진 주파수에 맞추어 83 kHz, 122 kHz 로 결정하였고, 이를 통해 발생되는 39 kHz의 차음 (difference frequency wave)을 통신 신호로 이용하였다. 통신 변조방법으로 On-Off Keying 방식을 이용하였다. 실험은 파라메트릭 어레이를 이용한 디지털 통신의 특성을 측정하기 위하여 파형 분석을 하였고, 거리, 각도에 따른 SNR을 측정해 보았다. 실험 결과 파라메트릭 어레이를 이용한 디지털 통신은 3m이내의 근거리 영역에서 적합함을 알 수 있었고, 빔폭 (-3 dB)은 $14^{\circ}$로 측정되어 고지향성 통신이 가능함을 확인하였다. 위의 실험 결과를 통해 파라메트릭 어레이를 이용한 공기 중 음향 통신에 대한 가능성을 확인하였고, 고지향성 통신 특성은 다중경로 문제나 보안 문제에 강점이 있을 것으로 판단된다.

N-365 다목적팬텀에서 초음파진단장치의 음속변화 효과 (The Effect of Acoustic Velocity of Ultrasonographic Equipment Using an N-365 Multipurpose Phantom)

  • 김연민;심재구;김상현
    • 한국방사선학회논문지
    • /
    • 제11권4호
    • /
    • pp.221-225
    • /
    • 2017
  • 초음파영상 진단장치의 성능을 평가할 때, 초음파장비에서 제공하는 음속변화 파라메타를 변화시킴에 따른 공간분해능의 변화를 알아보고자 하였다. 익산 소재 A기관에서 사용중인 초음파 진단장치에서 3.0 ~ 5.0 MHz 볼록형 탐촉자를 이용하여 초음파팬텀영상를 얻었다. N-365 다목적 초음파팬텀으로 종거리 측정정확도, 종 횡 해상도를 측정하였다. 같은 방법으로 초음파장치의 음속을1580 m/sec부터 1400 m/sec 까지 6단계로 변화시켜 측정 값의 차이가 있는지 image J 프로그램을 이용하여 반치폭을 측정하였다. 측정 결과, 횡측해상도는 속도변화에 따라 1.91 mm ~ 5.3 mm까지 측정되었으며, 음속 1420 m/sec 일 때 반치폭 1.91 mm로 가장 작게 측정되었다. 종측해상도는 1.03 mm ~ 1.14 mm까지 측정되었으며, 음속 1400 m/sec 일 때 반치폭 1.03 mm 로 가장 작게 측정되었다. 초음파장치의 음속이 느려질수록 종측정 길이가 짧아지는 상관관계를 보였다.

정재초음파를 이용한 유동중 미세 입자 위치 제어 (Position Control of Micro Particles in a Fluid Flow Using Ultrasonic Standing Wave)

  • 조승현;서대철;안봉영;김기복;김용일
    • 비파괴검사학회지
    • /
    • 제28권2호
    • /
    • pp.131-136
    • /
    • 2008
  • 정재초음파를 이용하면 유체에 잠겨 있거나 유체를 따라서 흐르는 미세 입자의 조작이 가능하다. 정재초음파 장이 입자에 힘을 작용하여 입자를 음압마디 또는 반음압마디로 이동시킨다. 본 연구에서는 정재초음파의 주파수를 조정함으로써 유동 중 미세 입자의 위치를 제어하는 방법을 제안하고자 한다. 이를 위해 먼저 수침형 초음파 트랜스듀서를 이용하여 폭 수 밀리미터의 미세 채널을 가지는 정재초음파 발생시스템을 구성하였다. 제안한 발생시스템을 이용하여 주파수 2 MHz부터 2.5 MHz까지 영역에서 정재초음파 장을 발생시키고, 물을 따라 흐르는 수 마이크로미터 내외의 탄화규소 입자가 음압 마디로 잘 이동함을 확인하였다. 이때, 미세 채널의 폭과 주파수가 입자의 거동에 미치는 영향을 관찰하였으며, 주파수가 미세입자의 이동 위치를 결정하는 중요한 파라미터임을 확인하였다. 결과적으로, 초음파의 주파수를 조정함으로써 입자의 이동 위치를 제어할 수 있음을 실험을 통해 확인하였으며 최대 범위는 약 261 마이크로미터이다. 본 연구로부터 유체내의 입자 조작에 있어서 정재초음파의 다양한 응용 가능성을 확인할 수 있었다.

강내온열 치료를 위한 원통형 초음파 치료기 개발 (Development of a cylindrical ultrasound applicator for Intracavitary Hyperthermia)

  • Lee, Rena J.;Hyunsuk Suh
    • 한국의학물리학회지:의학물리
    • /
    • 제13권2호
    • /
    • pp.79-84
    • /
    • 2002
  • 항문암 및 자궁경부암 치료시 사용되는 고선량률 강내 근접치료기와 병행하여 사용할 원통형 초음파 온열치료가 개발되었다. 온열치료를 위한 에너지원으로 원통형 트랜스듀서가(PZT-8 물질, 길이=1.5 cm 두께=1.5 mm 외경= 2.5cm) 사용되었다. PZT-8 물질의 특성을 측정하기위해 세 개의 단일 엘리멘트 어플리케이터가 제작되었다. PZT 물질을 작동하기 위한 주파수를 결정하기 위하여 벡터 임피던스가 측정되었다. 선택된 물질이 온열치료에 사용될 수 있는지 가능성을 타진하기위해 방사능력을 측정하는 방법으로 각 엘리맨트의 초음파발생 효율을 입력한 전기량과 발생한 초음파량의 비로 계산하였다. 마지막으로 질암의 온열치료에 사용할 수 있는 다채널 초음파 치료기가 디자인 되었다. 임피던스 실험결과 각 엘리맨트 1, 2, 그리고 3에 대해 1.78, 1.77, 그리고 1.77 MHz의 주파수에서 최대 임피더스 값을 얻었다. 방사능력 측정 실험결과 본 연구에서 사용된 에너지 소스는 40와트 이상의 초음파량이 방출되었다. 또한 각 엘리맨트 1, 2, 그리고 3의 평균 효율은 61.4, 65.2, 그리고 54.0% 이다. 본 연구에서 디자인되어진 원통형 초음파 치료기는 질 또는 항문 치료 시 고선량 강내근접치료와 더불어 사용할 수 있음이 증명되었다. 따라서 본 연구에서 개발된 온열 치료기구가 고 선량 강내 근접치료와 함께 사용하여 병변조직의 방사능 민감도를 증가시켜 암 치료효율을 높일수 있다.

  • PDF

신질환(腎疾患) 132례(例)의 초음파진단(超音波診斷) (Ultrasonographic Findings in 132 Cases of Renal Disease)

  • 한혜진;김강석
    • 보험의학회지
    • /
    • 제3권1호
    • /
    • pp.187-208
    • /
    • 1986
  • The conclusions which was acquired one renal cell carcinoma and renal disease 132 cases that was tested renal echogram among 4,499 cases for recent 16 months at medical department, Dae Han Kyoyuk Insurance company from August, 1984 to November, 1985 are as follows: 1. On bur ultrasonography, the echo of tumor was demonstrated with echogenicity as compared with renal parenchyme. 2. The case was stage I by Robson's modification method for pathologic histology. 3. There is no fever, typical triad of renal cell carcinoma and the result of serum biochemical test was within normal limit. 4. The frequency with disease was renal cell carcinoma(0.76%), ureteral stone(1.5%), multicystic kidney(2.27%), hydroureter(2.27%), Bilateral poly cystic kidney(4.55%), hydronephrosis(4.55%), renal agenesis(6.06%) renal calculi(18.18%), simple cyst(60.61%). 5. The frequency with age was 55/1200 case(4.58%) in $41{\sim}50$ years, 13/296 cases(4.39%) in $51{\sim}60$ years, 43/2144 cases(2.01%) in $31{\sim}40$ years, 14/791 cases(1.77%) in $21{\sim}30$ years, 7/53 cases(1.32%) more than 61 years and 0/15(0%) under 20 years. 6. The affected site of renal agenesis 8 cases was right side all. 7. In total renal disease 132 cases, the affected site of 126 cases except bilateral polycystic kidney 6 cases was right kidney 72 cases, left kidney the proportion of right to left 1.6:1 8. In total renal disease 132 cases except bilateral polycystic kidneys 6 cases, the patients affected with both side kidneys were 14 cases. 9. The affection rate with sex in total renal disease 132 cases was 98/2860 cases in male, 34/1819 cases in female and the former was about 2 times than the latter. 10. Classifying the stone with part, nephrolithiasis 24 cases were appeared high frequency, on the contray, ureteral stone 2 cases. 11. 2 cases of ureteral stone developed complication, hydronephrosis and hydroureter. 12. The linear array type transducer was not helpful for the diagnosis of lower ureteral calculi but for the lower ureteral calculi, we could see the stone with high echo in accompanying with acoustic shadowing. 13. In 24 cases of renal calculi, both side nephrolithiasis was 3 cases(12.5%). 14. In renal calculi, solitary stone could be seen extremely much and the number of stone was so much variable from 2 to 10. 15. In 26 cases with renal calculi and ureteral stone, the common clinical manifestation was a intermittent and slight pain. 16. In 80 cases of renal cyst, as one's get older, the affection rate of cyst extremely rised. 17. In bilateral polycystic kidney, large cyst had septum on the whole. 18. The patients with complication were 14 cases(10.6%) of total patients.

  • PDF