• Title/Summary/Keyword: acidic gas

Search Result 160, Processing Time 0.03 seconds

Optimal Operation Condition of Spray Drying Sorber for Simultaneous Removal of Acidic and Organic Gaseous Pollutants (산성 및 유기성 가스의 동시제거를 위한 준건식 세정시스템의 적정 운전 조건)

  • 백경렬;구자공
    • Journal of Environmental Science International
    • /
    • v.10 no.1
    • /
    • pp.59-64
    • /
    • 2001
  • The effect of major operating parameters in spray drying sorber(=SDS) for automatic control for the simultaneous removal of acidic and organic gaseous pollutants from solid waste incinerator was performed. The field experiment was carried out in pilot scale test for the quantification of major operating parameters of hydrophilic and the hydrophobic pollutants. The removal efficiencies of $SO_2$and HCI in the 5wt% slurry condition were being increased with the increase of the stoichiometric ration which is the molecular ratio of lime to the pollutant concentration, and with the decrease of inflow flue gas temperature in the pilot SDS reactor. The removal efficiency along the height of spray drying sorber was closely related to the temperature profile, and more than 90% of total removal efficiency was achieved in an absorption region. For the removal of acidic gas the optimum operating condition considering the economics and a stable operation is the 5wt% of slurry concentration, 1.2 of stoichiometric ratio and 25$0^{\circ}C$ of inflow flue gas temperature. For the organic gases of benzene and toluene the removal efficiencies were 20-60% which is much lower than that of acidic gas. The best removal efficiency was obtained at 1.5 of stoichiometric ratio and 25$0^{\circ}C$ of inflow flue gas temperature. The organic\`s removal efficiency along the height of spray drying sorber was quite different from that of acidic gas, that is, more than 60% of the total removal efficiency for benzene and 90% of the total removal for toluene were achieved in the dried adsorption region, which was formed at the lower or exit part of the reactor.

  • PDF

Plant morphological symptom caused by simulated acidic rain made by fuel gases (排氣가스로 만든 人工酸性雨에 의한 植物의 形態的 症狀)

  • Chang, Nam-Kee;Yun-Sang Lee;Soo-Jin Yi
    • The Korean Journal of Ecology
    • /
    • v.16 no.1
    • /
    • pp.17-26
    • /
    • 1993
  • We investigated the ph change of water caused by several fuel gases regarded as the main cause of the air pollution, To find out the main cause of increase of the acidity of the rain. We measured it while injrcting each fuel gas directiy to the distilled water. It was observed that bunker-c oil gas and anthracite coal gas were the main cause to make the ph of the solution lowest. We examined the effects of simulated acidic water solutions on several plant species. Simulated acidic rain made by bunker-c oil gas has significant symptom on the saxifraga stolonifera and commelina communis, while no injury was observed on plants exposed to simulated rainfall made by anthracite coal gas.

  • PDF

Study on the Effect of Corrosion Gas and Acidic Falling Materials for Conservational Wax on the Copper based Sculpture (동(銅)이 주종을 이루는 조형물 보존용 왁스의 산성강하물 및 부식 가스에서의 영향성 연구)

  • Oh, Seung-Jun;Wi, Koang-Chul
    • Journal of Conservation Science
    • /
    • v.26 no.4
    • /
    • pp.437-443
    • /
    • 2010
  • The influence of noxious corrosive gas, which is the product of fossil fuel, and the acidic descent material, which becomes the reason for such reaction, on wax which protects the cultural assets, and the habitat factor were researched. It could be viewed that corrosion occurred rapidly due to the acidic descent material, which have the long staying on the material, rather than harmful corrosive gas. Also, it could be figured out that such corrosion began from whitening phenomenon of coated wax. As the acidity increased, more whitening phenomenon occurred, and eventually, it could be found out that whitening effect began due to the acidic descent material, corrosive gas and various 0.1 M acid solution, which lead to the exposure of internal metal, and corrosion occurred. The wax with the greatest resistance to the acidity due to its least changing aspect seemed to be Renaissance wax, except sulfuric acid.

Fabrication of Chemical Sensors for the Detection of Acidic Gas using 1,3-bisdicyanovinylindane (1,3-bisdicyanovinylindane을 이용한 산성가스 감지용 화학 센서 제작)

  • Song, Hwan-Moon;Park, Young-Min;Son, Young-A;Lee, Chang-Soo
    • Korean Chemical Engineering Research
    • /
    • v.46 no.1
    • /
    • pp.184-188
    • /
    • 2008
  • This study presented simple and efficient fabrication of chemical sensors for the detection of acidic gas using 1,3-bisdicyanovinylindane as an indicator because it can be promising materials having property of the rapid color change according to the variation of pH. The dissociation of proton and dye in acidic condition as changing of ion pairs give rise to dramatically change the absorbance intensity of 1,3-bisdicyanovinylindane, which can be easily applied to the development of chemical sensors. In addition, indicator dyes having negatively charge in aqueous phase can be easily fabricated using layer-by-layer (LBL) methods by way of electrostatic interaction. For the proof of concept, we demonstrated the abrupt presentation of skeleton symbol on the chemical sensor, which could be resulted from the reaction of 1,3-bisdicyanovinylindane as background color with acidic gas. Thus, the rapid appearance of symbol will induce user's caution under the emergency condition. The presented chemical gas sensor using 1,3-bisdicyanovinylindane have strong advantages. First, the fabrication process of gas sensor was very simple and low-cost. Secondly, sensors reacted by acidic gas could be reused for several times. Finally, the chemical gas sensor would be environmentally friend, which can be a basic tool for the realization of eco-organic sensor device.

Influences of Cathodic Protection and Coating Properties on the Corrosion Control of Metallic Structure in Extremely Acidic Fluids

  • Chang, H.Y.;Yoo, Y.R.;Jin, T.E.;Kim, Y.S.
    • Corrosion Science and Technology
    • /
    • v.4 no.6
    • /
    • pp.242-249
    • /
    • 2005
  • A lot of parts in FGD (Flue Gas Desulfurization) systems of fossil-fuel power plants show the environments in which are highly changeable and extremely acidic corrosive medium according to time and locations, e.g. in duct works, coolers and re-heaters etc. These conditions are formed when system materials are immersed in fluid that flows on them or when exhausted gas is condensed into thin layered acidic medium to contact materials of the system walls and roofs. These environments make troublesome corrosion and air pollution problems that are occurred from the leakage of the condensed solution. To cathodically protect the metallic structures in extremely acidic fluid, the properties of the protective coatings on the metal surface were very important, and epoxy Novolac coating was applied in this work. On the base of acid immersion tests, hot sulfuric acid decreased the hardness of the coatings and reduced greatly the content of $Na_2O$, $Al_2O_3$, and $SiO_2$ among the main components of the coating. A special kind of CP(Cathodic Protection) system has been developed and tested in a real scale of the FGD facility. Applied coating for this CP system was peeled off and cracked in some parts of the facility. However, the exposed metal surface to extremely acidic fluid by the failure of the coatings was successfully protected by the new CP system.

Carbon Stable Isotope Ratios of Phytoplankton and Benthic Diatoms in Lake Katanuma with Reference to Those of Other Lakes

  • Kikuchi, Eisuke;Takagi, Shigeto;Shikano, Shuichi;Hideyuki, Doi
    • Korean Journal of Ecology and Environment
    • /
    • v.38 no.spc
    • /
    • pp.8-11
    • /
    • 2005
  • Carbon stable isotope ratios of producers varied in lake ecosystems. In tile present study, we tried to estimate the seasonal variations of carbon isotope ratios of phytoplankton and benthic diatoms in a strongly acidic lake ecosystem. Lake Katanuma is a volcanic, strongly acidic lake (average pH of 2.2), located in Miyagi, Japan. Only two algal species dominate in Lake Katanuma; Pinnularia acidojaponica as a benthic diatom, and Chlamydomonas acidophila as a green alga. Carbon isotope values of P. acidojaponica varied seasonally, while those of particulate organic matter, which were mainly composed of C. acidophila remained fairly stable. The differences suggested that $CO_2$ gas was more frequently limited for P. acidojaponica than C. acidophila, since high density patches of benthic diatoms were sometimes observed on the lake sediment. Generally, carbon concentration mechanisms (CCMs)of microalgae can fix bicarbonate in lakes, and affect the carbon isotope values of microalgae. While, in Lake Katanuma, CCMs of the microalgae may scarcely function because of high $CO_2$ gas concentration and low pH. This is the reason for low seasonal amplitude of carbon isotope values of phytoplankton relative to those in other lakes.

Ammonia neutralization and removal using electrolyzed-acidic water (전해산성수를 이용한 암모니아 중화와 제거)

  • Choi, Weon-Kyung
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.5
    • /
    • pp.185-190
    • /
    • 2021
  • An electrolyzed-acidic water treatment was investigated as a methods for removing ammonia, which is a cause of odor in life environment. The prepared electrolyzed-acidic water was found out as stable solvent capable of neutralizing weak alkaline ammonia by measuring changes in pH and ORP. It was found out that ammonia was removed from the mixture solution of electrolyzed-acidic water and ammonia water by the UV-vis absorbance analysis and electrochemical open-circuit potential measurement. The neutralized ammonia by electrolyzed-acidic water and effectively removed odor was measured using ammonia gas detecter. Consequently, we recommend the electrolyzed-acidic water can effectively and safely remove ammonia in eco-friendly.

Characteristics of Acidic Gas Emissions from Combustion with Preblending of Coal and Sludge (석탄과 슬러지의 예혼합연소에 따른 산성가스 배출특성)

  • Shim, Sung-Hoon;Jeong, Sang-Hyun;Min, Hyo-Ki;Lee, Sang-Sup
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.2
    • /
    • pp.103-108
    • /
    • 2014
  • Using dried sludge as a secondary fuel of a coal-fired power plant is proposed as an alternative option for sludge disposal. Because elemental contents of sludge are different from those of coal, different levels of acidic gas emissions are expected from the co-combustion of sludge with coal. In this study, sludge samples were obtained from 7 sewage treatment plants in Korea. Each sludge sample was combusted together with coal in a lab-scale combustor, and the concentrations of nitrogen oxides ($NO_x$), sulfur dioxide ($SO_2$), hydrogen chloride (HCl), chlorine ($Cl_2$) in the flue gas were analyzed. Compared to the combustion of coal only, $NO_x$ concentration was slightly higher in the flue gas from the co-combustion of coal and sludge. $SO_2$ emission increased with the combustion of sludge due to the higher content of sulfur in sludge than in coal. For most of the tested samples, the concentrations of HCl and $Cl_2$ were varied depending on the chlorine content in the sludge sample.

The Study on the Wear Corrosion Behavior of Induction Hardening High Strength Cast Iron in the pH Environments (고주파 열처리한 강인주철재의 마멸부식거동에 관한 연구)

  • Park, Yun-Sik;Lim, Uh-Joh;Park, Dong-Gi
    • Journal of the Korean Institute of Gas
    • /
    • v.12 no.4
    • /
    • pp.52-57
    • /
    • 2008
  • This paper studies on the wear corrosion behavior of induction hardening high strength cast iron in the acidic environments. In a variety of pH solutions, wear corrosion behavior of GC 300 with a variety of contact pressures was investigated, and corrosion wear behavior after immersion test was considered. Also, electrochemical polarization test for GC 300 was carried out in various pH solutions. The main results are as following: In the strong acidic environment, wear corrosion rate of GC 300 appears highly and in the neutral environment is stable. Also, graphitic corrosion in the strong acidic environment occurs. The corrosion current density of GC 300 becomes high in a order of pH 1 > pH 2 > pH 4 > pH 6.5.

  • PDF

Indoor Air Quality of Acidic Air Pollutants at a Private House in Seoul During the Spring Months

  • Lee, Hak-Sung;Kang, Byung-Wook;Kang, Choong-Min;Yeo, Hyun-Gu
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.17 no.E3
    • /
    • pp.109-115
    • /
    • 2001
  • Acidic air pollutants were collected to characterize indoor air quality at a private house in Seoul during the spring period. All indoor and outdoor samples were measured simultaneously using an annular denuder system. The data set was collected on twelve different days with a 24-hr sampling period in April and May 1997. The chemical species measured were HN $O_3$, HN $O_2$, S $O_2$ and N $H_3$in the gas phase and P $M_{2.5}$ (dp 2.5 ${\mu}{\textrm}{m}$), S $O_4$$^{2-}$, N $O_3$$^{[-10]}$ and N $H_4$$^{+}$ in the particulate phase. Indoor concentrations of HN $O_2$, N $H_3$, and P $M_{2.5}$ were greater than outdoor levels. However, indoor concentrations of HN $O_3$, S $O_2$, N $O_3$$^{[-10]}$ and N $H_4$$^{+}$ were less than those found from outdoors. In the case of S $O_4$$^{2-}$, the indoor and outdoor concentrations were similar. Indoor concentrations of P $M_{2.5}$ , S $O_4$$^{2-}$ and N $O_3$$^{[-10]}$ were dependent upon the outdoor concentrations. A tracer-gas decay technique with sulfur hexafluoride (S $F_{6}$ ) as the tracer gas was used to estimate the air exchange rate of a private home in the spring. The average air exchange rate was computed to be 2.87 h $r^{-1}$ .X> .

  • PDF