• 제목/요약/키워드: acid-etched

검색결과 298건 처리시간 0.02초

치주염에 이환되어 발거된 치아의 치주인대가 없는 치근표면에 EDTA처리를 한 후 3차원적으로 배양한 사람치주인대섬유모세포의 부착에 관한 주사전자현미경적 연구 (The 3-dimensional attachment of human periodontal ligament fibroblasts on periodontally involved root surface following treatment with EDTA: A SEM study in vitro)

  • 조아영;김병옥;박주철;김흥중;장현선
    • Journal of Periodontal and Implant Science
    • /
    • 제37권1호
    • /
    • pp.45-51
    • /
    • 2007
  • This study evaluated the possibility of the 3-dimensional attachment of human periodontal ligament fibroblasts to a periodntally involved root surface after an EDTA treatment in vitro. The human PDL fibroblasts were isolated from the middle third of the root of periodontally healthy teeth extracted for orthodontic reasons. The cells were cultured in a medium containing Dulbecco's modified Eagle medium supplemented with 10% fetal bovine serum at $37^{\circ}C$ in humidified air containing 5% $CO_2$. Eight single-rooted teeth were obtained from patients diagnosed with periodotitis. After scaling and root planing, four teeth were etched with 24% ethylenediaminetetracetic acid (EDTA) for two minutes (Experimental group). The other four teeth were not treated with EDTA and were used as the control group. The human PDL fibroblasts were placed in the total root surface and cultured for 4 weeks. The teeth were fixed in 2.5% glutaraldehyde in PBS before preparation for the scanning electron microscopy (SEM) examination. The human PDL fibroblasts showed a healthy morphology on the root surfaces treated with EDTA (Experimental group) and a relatively unhealthy appearance on the treated root surfaces (Control group). This suggests that EDTA favorably affects the 3-dimensional attachment of human PDL fibroblasts cultured on the root surfaces. which may play an important role in periodontal healing and regeneration.

부착 유지장치의 직, 간접 부착법에 따른 전단 접착력 비교 (Direct and indirect bonding of wire retainers to bovine enamel using three resin systems: shear bond strength comparisons)

  • 권태엽;;;박효상
    • 대한치과교정학회지
    • /
    • 제41권6호
    • /
    • pp.447-453
    • /
    • 2011
  • Objective: We compared the shear bond strength (SBS) of lingual retainers bonded to bovine enamel with three different resins using direct and indirect methods. Methods: Both ends of pre-fabricated twisted ligature wires were bonded to bovine enamel surfaces using Light-Core, Tetric N-Flow, or Transbond XT. Phosphoric acid-etched enamel surfaces were primed with One-Step prior to bonding with Light-Core or Tetric N-Flow. Transbond XT primer was used prior to bonding with Transbond XT. After 24 hours in water at $37^{\circ}C$, we performed SBS tests on the samples. We also assigned adhesive remnant index (ARI) scores after debonding and predicted the clinical performance of materials and bonding techniques from Weibull analyses. Results: Direct bonding produced significantly higher SBS values than indirect bonding for all materials. The SBS for Light-Core was significantly higher than that for Tetric N-Flow, and there was no significant difference between the direct bonding SBS of Transbond XT and that of Light-Core. Weibull analysis indicated Light-Core performed better than other indirectly bonded resins. Conclusions: When the SBS of a wire retainer is of primary concern, direct bonding methods are superior to indirect bonding methods. Light-Core may perform better than Transbond XT or Tetric N-Flow when bonded indirectly.

치과용복합레진과의 결합에 있어, 상아질 내 교원섬유의 역할에 관한 연구 (TITLE : THE ROLE OF COLLAGEN FIBER IN DENTIN BONDING)

  • 박성호
    • Restorative Dentistry and Endodontics
    • /
    • 제22권1호
    • /
    • pp.470-478
    • /
    • 1997
  • The purpose of this study was to investigate the effects of moistening mechods of dentin on the morphologic states of hybrid layers and on the interfacial bond strength between dentin and composite. Specimens were divided into 6 groups based on the surface moistening methods and materials used. After the dentin surface was conditioned with 10 % phoporic acid and irrigated: 1. The dentin surface was dried. Then bonding agent and composite were applied. 2. The dentin surface was blot-dryed. Then primer, bonding atent and composite were applied. 3. The dentin surface was dryed first. Within 20 seconds, the surface was rewetted, then primer, bonding agent and composite were applied. 4. The dentin surface was dryed. Then primer, bonding agnent and composite were applied. 5. The dentin surface was dryed first. Atter 24hrs, the surface was rewetted, and then primer, bonding agent and composite were applied. 6. The surface was conditioned with NaOCl for 5min. Then primer, bonding agent and composite were applied. To reveal the hybrid layer, scanning electron microscopy was used after the samples were ion beam etched. The shear bond strength of each group was tom pared by ANOVA. In groups 2, 3 and 4, the hybrid layer was clearly visible, but the width was more limited in group 4. In group 1 and 5, the hybrid layer was not found, and a gap was formed between dentin and composite. In group 6, the hybrid layer was not found, but the interface between the dentin and composite was intimate. The shear bond strength of each group was as follows: Group 1 : 4MPa, Group 2 : 14MPa, Group 3 : 12MPa, Group 4 : 14MPa, Group 5 : 5MPa, Group 6 : 9MPa.

  • PDF

A STUDY ON THE CORRELATION BETWEEN IMPLANT STABILITY VALUES AND INITIAL INSERTION TORQUE

  • Lee Jong-Hyuk;Yang Jae-Ho
    • 대한치과보철학회지
    • /
    • 제44권3호
    • /
    • pp.314-324
    • /
    • 2006
  • Statement of problem. Osseointegration is important mechanism of dental implant but it is not easy to evaluate. Indirect measurement is non-invasive and clinically applicable but they need more study about correlation between indirect values and degree of osseointegration. Purpose. The aims of this study were to evaluate the coefficient of correlation between indirect measurement and direct measurement under different healing time, and assessment of effect of initial insertion torque to the implant stability. Material and Methods. 20 rabbits received 3 implants on each side of tibia. Three kinds of implants (machined surface implant, Sandblasted with Large grit and Acid etched implant, Resorbable Blast Media treated implant) were used. During the surgery implant insertion torque were measured with $Osseocare^{TM}$. After the 1, 4, 8, 12 weeks of healing time, animals were sacrificed and stability values (Implant Stability Quotient with $Osstell^{TM}$, removal torque with torque gauge) were measured. Results. The Bone quality of rabbit tibia was classified into 2 groups according to the insertion torque. Resonance frequency analysis (ISQ) and removal torque showed positive correlation until $4^{th}$ week (r=0.555, p=0.040). After $8^{th}$ week (r=0.011, p=0.970) the correlation became weak and it turned negative at $12^{th}$ week (r=-0.074, p=0.801). Insertion torque and ISQ showed changing correlation upon the healing time ($1^{st}$ week: r=0.301, p=0.033, $4^{th}$ week: r=-0.429, p=0.018, $8^{th}$ week: r=0.032, p=0.865, $12^{th}$ week: r=-0.398, p=0.029). Insertion torque and removal torque has positive correlation but it was not statistically significant ($1^{st}$ week: r=0.410, p=0.129, $4^{th}$ week: r=0.156, p=0.578, $8^{th}$ week: r=0.236, p=0.398, $12^{th}$ week: r=0.260, p=0.350). Conclusion. In this study, bone quality may affect the degree of osseointegration positively during healing time and correlation between ISQ and degree of osseointegration can be different according to the healing time and bone quality.

Effect of dimethyl sulfoxide on bond durability of fiber posts cemented with etch-and-rinse adhesives

  • Shafiei, Fereshteh;Memarpour, Mahtab;Sarafraz, Zahra
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권4호
    • /
    • pp.251-258
    • /
    • 2016
  • PURPOSE. This study was undertaken to investigate whether use of an adhesive penetration enhancer, dimethyl sulfoxide (DMSO), improves bond stability of fiber posts to root dentin using two two-step etch-and-rinse resin cements. MATERIALS AND METHODS. Forty human maxillary central incisor roots were randomly divided into 4 groups after endodontic treatment and post space preparation, based on the fiber post/cement used with and without DMSO pretreatment. Acid-etched root dentin was treated with 5% DMSO aqueous solution for 60 seconds or with distilled water (control) prior to the application of Excite DSC/Variolink II or One-Step Plus/Duolink for post cementation. After micro-slicing the bonded root dentin, push-out bond strength (P-OBS) test was performed immediately or after 1-year of water storage in each group. Data were analyzed using three-way ANOVA and Student's t-test (${\alpha}$=.05). RESULTS. A significant effect of time, DMSO treatment, and treatment${\times}$time interaction were observed (P<.001). DMSO did not affect immediate bonding of the two cements. Aging significantly reduced P-OBS in control groups (P<.001), while in DMSO-treated groups, no difference in P-OBS was observed after aging (P>.05). CONCLUSION. DMSO-wet bonding might be a beneficial method in preserving the stability of resin-dentin bond strength over time when fiber post is cemented with the tested etch-and-rinse adhesive cements.

In vivo comparison between the effects of chemically modified hydrophilic and anodically oxidized titanium surfaces on initial bone healing

  • Lee, Hyo-Jung;Yang, Il-Hyung;Kim, Seong-Kyun;Yeo, In-Sung;Kwon, Taek-Ka
    • Journal of Periodontal and Implant Science
    • /
    • 제45권3호
    • /
    • pp.94-100
    • /
    • 2015
  • Purpose: The aim of this study was to investigate the combined effects of physical and chemical surface factors on in vivo bone responses by comparing chemically modified hydrophilic sandblasted, large-grit, acid-etched (modSLA) and anodically oxidized hydrophobic implant surfaces. Methods: Five modSLA implants and five anodized implants were inserted into the tibiae of five New Zealand white rabbits (one implant for each tibia). The characteristics of each surface were determined using field emission scanning electron microscopy, energy dispersive spectroscopy, and confocal laser scanning microscopy before the installation. The experimental animals were sacrificed after 1 week of healing and histologic slides were prepared from the implant-tibial bone blocks removed from the animals. Histomorphometric analyses were performed on the light microscopic images, and bone-to-implant contact (BIC) and bone area (BA) ratios were measured. Nonparametric comparison tests were applied to find any significant differences (P<0.05) between the modSLA and anodized surfaces. Results: The roughness of the anodized surface was $1.22{\pm}0.17{\mu}m$ in Sa, which was within the optimal range of $1.0-2.0{\mu}m$ for a bone response. The modSLA surface was significantly rougher at $2.53{\pm}0.07{\mu}m$ in Sa. However, the modSLA implant had significantly higher BIC than the anodized implant (P=0.02). Furthermore, BA ratios did not significantly differ between the two implants, although the anodized implant had a higher mean value of BA (P>0.05). Conclusions: Within the limitations of this study, the hydrophilicity of the modSLA surface may have a stronger effect on in vivo bone healing than optimal surface roughness and surface chemistry of the anodized surface.

How will surface treatments affect the translucency of porcelain laminate veneers?

  • Turgut, Sedanur;Bagis, Bora;Ayaz, Elif Aydogan;Korkmaz, Fatih Mehmet;Ulusoy, Kivanc Utku;Bagis, Yildirim Hakan
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권1호
    • /
    • pp.8-13
    • /
    • 2014
  • PURPOSE. The purpose of this study was to evaluate whether surface treatments affect the translucency of laminate veneers with different shades and thicknesses. MATERIALS AND METHODS. A total of 224 disc-shaped ceramic veneers were prepared from A1, A3, HT (High Translucent) and HO (High Opaque) shades of IPS e.max Press (Ivoclar Vivadent) with 0.5 mm and 1.0 mm thicknesses. The ceramics were divided into four groups for surface treatments. Group C: no surface treatments; Group HF: etched with hydrofluoric acid; Group SB: sandblasted with 50-${\mu}m$ $Al_2O_3$; and Group L; irradiated with an Er;YAG laser. A translucent shade of resin cement (Rely X Veneer, 3M ESPE) was chosen for cementation. The color values of the veneers were measured with a colorimeter and translucency parameter (TP) values were calculated. A three-way ANOVA with interactions for TP values was performed and Bonferroni tests were used when appropriate (${\alpha}=0.05$). RESULTS. There were significant interactions between the surface treatments, ceramic shades and thicknesses (P=.001). For the 0.5-mm-thick specimens there were significant differences after the SB and L treatments. There was no significant difference between the HF and C treatments for any shades or thicknesses (P>.05). For the 1-mm-thick ceramics, there was only a significant difference between the L and C treatments for the HT shade ceramics (P=.01). There were also significant differences between the SB and C treatments except not for the HO shades (P=.768). CONCLUSION. The SB and L treatments caused laminate veneers to become more opaque; however, HF treatment did not affect the TP values. When the laminate veneers were thinner, both the shade of the ceramic and the SB and laser treatments had a greater effect on the TP values.

충주 숭선사지 출토 철제유물의 미세조직 분석 (Microstructure investigation of iron artifacts excavated from Sungseonsa Temple in Chungju city)

  • 유재은;고형순;이재성
    • 보존과학연구
    • /
    • 통권24호
    • /
    • pp.187-213
    • /
    • 2003
  • Sungseonsa Temple site in Chungju city in Chungcheongbuk-doProvince is written in "Goryeosa" as a building for Queen Sinmyeongsunseong, the mother of Gwangjong in AD 954 in Goryeo Dynasty. The museum in Chungcheong University takes charge of the excavation for 3 times from 2000 to 2002 and identified that its construction was carried out till Joseon Dynasty. Among the iron artifacts from the first excavation such as a weeding hoe, a hand knife, a lock, two nails and a plow which had conservation treatments, the sample was collected. Its micro-structure and method of manufacture were investigated. Excavation report for those artifacts has not published yet, therefore, the date of each artifacts is not clearly confirmed. The samples were collected from each part of the objects and then embedded in epoxy resin and etched with nitric acid. The examination of its microstructure is carried out under the microscope and the hardness values were measured by Vickers hardness tester. From the results, some artifacts show different manufacture method sin the each parts. The forming processes of the iron weeding hoe and the iron sickle are similar but the blade of iron weeding hoe was strengthened by carbonization whereas the blade of the iron sickle was done by quenching. The hand knife and the nails were produced through almost same methods and shows similar microstructures. The hand knife seems to be made by repeated beating and folding in low temperature resulting in fine crystallization, but the nail shows large crystallization due to processes in high temperature. Lock is made of white cast iron, that does not show any heat treatment.

  • PDF

성장 인자가 농축된 Fibrin rich block을 이용한 상악동 거상술에서의 신생골 형성에 관한 연구 (New bone formation using fibrin rich block with concentrated growth factors in maxillary sinus augmentation)

  • 김지민;이주형;박인숙
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제37권4호
    • /
    • pp.278-286
    • /
    • 2011
  • Introduction: This study examined the predictability of new bone formation in the pneumatized maxillary sinus using only fibrin-rich blocks with concentrated growth factors as an alternative to bone grafts. Materials and Methods: Maxillary sinus augmentation was performed in thirty-three patients with a deficient alveolar bone height (mean 3.9 mm). All patients were treated consecutively with sinus membrane elevation via the lateral window approach and panoramic radiograms and cone-beam computed tomograms were taken to evaluate the remaining bone height and the new bone formation in the maxillary sinus, before and after surgery. Four biopsy specimens were taken at the time of implant consolidation (after an average of five months healing) and were stained by H & E and Trichrome staining. Results: None of the patients had postoperative complications during implant consolidation. After an average of 5 months since sinus augmentation, newly formed bone was observed in all cases by a radiographic evaluation. In 4 biopsy samples, newly formed bone was observed along the floor of the replaced bony window. The osteoblast lining and well distinguished Osteocytes in the lacunas were observed in the newly formed bone. Of the 74 implants (4 different surfaced implants - resorbable blast media-surfaced (RBM), Hydroxyapatite (HA) coated, acid-etched, sintered porous-surfaced implant) placed, one RBM implant failed. The success rate was 98.6% after a mean of 15 months. Discussion: These results suggest that maxillary sinus augmentation using fibrin rich block with concentrated growth factors is a successful and predictable technique.

Histologic evaluation and removal torque analysis of nano- and microtreated titanium implants in the dogs

  • Ahn, Seok;Vang, Mong-Sook;Yang, Hong-So;Park, Sang-Won;Lim, Hyun-Pil
    • The Journal of Advanced Prosthodontics
    • /
    • 제1권2호
    • /
    • pp.75-84
    • /
    • 2009
  • STATEMENT OF PROBLEM. A number of studies about the nano-treated surfaces of implants have been conducting along with micro-treated surfaces of implants. PURPOSE. The purpose of this study was to get information for the clinical use of nano-treated surfaces compared with micro-treated surfaces by measuring removal torque and analyzing histological characteristics after the placement of various surface-treated implants on femurs of dogs. MATERIAL AND METHODS. Machined surface implants were used as a control group. 4 nano-treated surface implants and 3 micro-treated surface implants [resorbable blast media surface (RBM), sandblast and acid-etched surface (SAE), anodized RBM surface] were used as experimental groups. Removal torque values of implants were measured respectively and the histological analyses were conducted on both 4weeks and 8weeks after implant surgery. The surfaces of removed implants after measuring removal torque values were observed by scanning electron microscopy (SEM) at 8 weeks. RESULTS. 1. Removal torque values of the nano-treated groups were lower than those of micro-treated groups. 2. Removal torque values were similar in the anodized RBM surface groups. 3. On the histological views, there was much of bone formation at 8 weeks, but there was no difference between 4 and 8 weeks, and between the types of implant surfaces as well. CONCLUSION. it is suggested that implant topography is more effective in removal torque test than surface chemistry. To get better clinical result, further studies should be fulfilled on the combined effect of surface topography and chemistry for the implant surface treatments.