• Title/Summary/Keyword: accurate prosthesis

Search Result 59, Processing Time 0.03 seconds

A study of introduction for using Laser in dental prosthesis (치과보철영역에 레이저 이용을 위한 이론적 고찰)

  • Park, Myoung-Ho;Bae, Bong-Jin;Lee, Hwa-Sik
    • Journal of Technologic Dentistry
    • /
    • v.30 no.1
    • /
    • pp.131-139
    • /
    • 2008
  • It's very important to find the most appropriate adhesion technique available, taking into consideration factors such as biocompatibility, non-corrosiveness, mechanical stability, etc. Laser welding is the best choice you can make because from a mechanical viewpoint, a laser welded surface has better particle structure than does a casted particle structure. Furthermore, it requires no additional material and the same metal alloy which is used when casting can be used. Therefore, the resulting mixture will consist of a single alloy, instead of utilizing different alloy combinations. Another benefit is the low economic cost. The most beneficial aspects of laser welding is that it is biologicallly friendlly, doesn't require soldering, can fuse different metal alloys together, and can weld on heat-sensitive spots(E.g. around resin or ceramic). A consistent strong pulse is possible. This technique is capable of welding on master models and creates accurate welds. It is capable of due to its stronger, non-corrosive microscope, which allows 25times magnification during the soldering process. This is possible because of its high stability from the tiny particle structure.

  • PDF

THE MANAGEMENT OF A COMPLEX IMPLANT CASE USING CAD-CAM TECHNOLOGY: A CLINICAL REPORT

  • Park, Eun-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.6
    • /
    • pp.634-638
    • /
    • 2008
  • PURPOSE: The application of computer-aided technology to implant dentistry has created new opportunities for treatment planning, surgery and prosthodontic treatment, but the correct selection and combination of available methods may be challenging in times. Hence, the purpose of this case report is to present a combination of several computer-aided tools as approaches to manage complicated implant case. MATERIAL AND METHODS: A 47 year-old female patient with severe dental anxiety, high expectations, financial restrictions and poor compliance presented for a fixed rehabilitation. A CT scan with a radiographic template obtained with software (SimPlant, Materialize, Leuven, Belgium) was used for treatment planning. The surgical plan was created and converted into a stereolithographic model of the maxilla with bone-supported surgical templates (SurgiGuide, Materialise, Leuven, Belgium), that allowed for the precise placement of 7 implants in a severely resorbed edentulous maxilla. After successful osseointegration, an accurate scan model served as the basis for the fabrication of a one-piece milled titanium framework using the Procera (Nobel Biocare, Gothenburg, Sweden) technology. The final rehabilitation of the edentulous maxilla was rendered in the form of a screw-retained maxillary metal-reinforced resin-based complete prosthesis. RESULTS: Despite challenging circumstances, 7 implants could be placed without bone augmentation in a severely resorbed maxilla using the SimPlant software for pre-implant analysis and the SurgiGuide-system as the surgical template. The patient was successfully restored with a fixed full arch restoration, utilizing the Procera system for the fabrication of a milled titanium framework.

Distal Type of Aortopulmonary Septal Defect with Aortic Origin of Right Pulmonary Artery and Interruption of the Aortic Arch - A Case of Successful Surgical Report -

  • Jeong, Yun-Seop;Song, Myeong-Geun
    • Journal of Chest Surgery
    • /
    • v.24 no.7
    • /
    • pp.693-700
    • /
    • 1991
  • A rare case of the association of distal aortopulmonary septal defect, aortic origin of the right pulmonary artery, intact ventricular septum, patent ductus arteriosus and interrupted aortic isthmus in a 40-day-old infant is reported. The infant was suffered from two operations with an interval of nine days. At the first operation a 10mm polytetrafluoroethylene prosthesis was inserted instead of the interrupted aortic isthmus and ductus was ligated via the left posterolateral thoracotomy. But the patient could not be weaned from the respirator because of large amount of left-to-right shunt. So the total correction was subsequently performed after an interval of nine days. At the second operation, tunneling of the right pulmonary artery to the main pulmonary artery through the aortopulmonary septal defect was performed using the Dacron patch via a longitudinal transaortic approach and a separate autologous pericardial patch was applied to the longitudinally incised margins of the anterior wall of the ascending aorta. The second postoperative course was relatively uneventful except some respiratory distress and nutritional problems. Now he is at 6 months of age and thrives well without any symptom. Because the success of the surgical repair of this complex anomalies depends upon the accurate diagnosis and meticulous design of each step of procedure prior to operation these problems are also discussed.

  • PDF

Maxillary anterior single implant prosthesis ; a clinical case

  • Kim Seung-June;Kwon Kung-Rock;Lee Sung-Bok;Woo Yi-Hyung;Choi Dae-Gyun;Choi Boo-Byung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.3
    • /
    • pp.306-312
    • /
    • 2001
  • Achieving an aesthetic implant-supported restoration in the single tooth missing case can be challenging when the implant site is in e anterior region. The objective of this report is to focus on presurgical evaluation of implant site and systematic development of related prosthetic modalities. An accurate diagnostic evaluation, a systematically developed pesurgical plan, and knowledge and clinical skill of the various related therapeutic modalities are indispensible. Collection of patient's information, appropriate abutment selection, soft tissue contour, implant axis, and occlusion need to be discussed for aesthetic clinical outcome. For aesthetic restoration, such as surgical guide stent for precise implant positioning customized provisional restoration for development of optimal periimplant soft tissue contours, and fabrication customized abutment (mesiostructure) for veriable emergence profile, are recommended.

  • PDF

Full mounth rehabilitation using OP finder® system for patient with inadequate occlusal plane and multiple occlusal wear tooth state: a case report (부적절한 교합평면과 다수의 교합면 마모를 가진 환자에서 OP finder® system을 이용한 전악 수복증례)

  • Lee, Seon-Ki
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.37 no.3
    • /
    • pp.138-146
    • /
    • 2021
  • The diagnosis and treatment plan for forming ideal occlusal plane in full mouth rehabilitation are difficult because each process is complicated and information exchange between dentist and technician is subjective. The OP finder® system simplifies this process and helps to deliver more objective and accurate information. In this case, full mouth rehabilitation was performed using OP finder® system for patients with old bad fixed prosthesis and severely worn mandibular teeth, and reported that the result of proper occlusal plane setting and masticatory function recovery was obtained.

Accuracy of virtual models in the assessment of maxillary defects

  • Kamburoglu, Kivanc;Kursun, Sebnem;Kilic, Cenk;Ozen, Tuncer
    • Imaging Science in Dentistry
    • /
    • v.45 no.1
    • /
    • pp.23-29
    • /
    • 2015
  • Purpose: This study aimed to assess the reliability of measurements performed on three-dimensional (3D) virtual models of maxillary defects obtained using cone-beam computed tomography (CBCT) and 3D optical scanning. Materials and Methods: Mechanical cavities simulating maxillary defects were prepared on the hard palate of nine cadavers. Images were obtained using a CBCT unit at three different fields-of-views (FOVs) and voxel sizes: 1) $60{\times}60mm$ FOV, $0.125mm^3$ ($FOV_{60}$); 2) $80{\times}80mm$ FOV, $0.160mm^3$ ($FOV_{80}$); and 3) $100{\times}100mm$ FOV, $0.250mm^3$ ($FOV_{100}$). Superimposition of the images was performed using software called VRMesh Design. Automated volume measurements were conducted, and differences between surfaces were demonstrated. Silicon impressions obtained from the defects were also scanned with a 3D optical scanner. Virtual models obtained using VRMesh Design were compared with impressions obtained by scanning silicon models. Gold standard volumes of the impression models were then compared with CBCT and 3D scanner measurements. Further, the general linear model was used, and the significance was set to p=0.05. Results: A comparison of the results obtained by the observers and methods revealed the p values to be smaller than 0.05, suggesting that the measurement variations were caused by both methods and observers along with the different cadaver specimens used. Further, the 3D scanner measurements were closer to the gold standard measurements when compared to the CBCT measurements. Conclusion: In the assessment of artificially created maxillary defects, the 3D scanner measurements were more accurate than the CBCT measurements.

Homograft Replacement in Prosthetic Valve Endocarditis(PVE) -One Case Report (심내막염 환자의 동종이식편 치환술 -1례 보고-)

  • Park, Jung-Won;Park, Guk-Yang;Kim, Ung-Han
    • Journal of Chest Surgery
    • /
    • v.30 no.8
    • /
    • pp.815-818
    • /
    • 1997
  • Prosthetic valve endocarditis(PVE), although uncommon, is associated with significant mortality if the infection spreads into the paravavular structures with later abscess formation. However, combined antibiotic and surgical treatment is often successful. Accurate diagnosis by on echocardiography, effective myocardial protection during operation and increased surgical experience have improved the short-term and long-term outcomes for patients with PVE. A 35-year-old male had a history of replacement of aortic and mitral valve, and tricuspid annuloplasty on August 1994, was admitted due to sudden onset of aphasia, leftward deviation of both eyeballs and spiking fever and diagnosed of having PVE by echocardiography. Reoperation was done after 6weeks of antibiotic treatment. On the operative field, we could notice circumferential vegetation along aortic valve annulus, paravalvular leakage and abscess pocket. The mitral valve amlulus was healthy. The patient underwent redo aortic valve replacement using cryopreserved aortic homograft after radical debridement of infected issue. During the follow up of 7 months period the homograft was well functioning without recurrence of symptoms.

  • PDF

Retreatment of implant overdenture using Milled Bar and Attachment in a patient using a unilateral prosthetic arm: A case report (편측 의수 사용 환자에서 Milled Bar와 Attachment를 이용한 임플란트 피개의치 재수복 증례)

  • Park, So-Hyung;Jeong, Chang-Mo;Yun, Mi-Jung;Huh, Jung-Bo;Lee, So-Hyoun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.2
    • /
    • pp.187-194
    • /
    • 2022
  • The use of implants could improve the support, retention, and stability of removable prosthetic restoration for fully edentulous patients with severe alveolar bone resorption. When the prosthesis is manufactured without accurate diagnosis and evaluation, this may lead to unfavorable treatment result. The patient in this case had the treatment of implant overdentures at a private dental clinic, but visited the hospital for retreatment due to soft tissue pain and decreasing retention of existing dentures. The vertical dimension was raised compared to the existing dentures, and overdentures were manufactured using milled bars and additional attachments. The clinical results were satisfactory in the aspect of improved oral hygiene maintenance, function and esthetics.

Full mouth rehabilitation of a worn dentition using digital guided tooth preparation: a case report (과도한 구치부 마모를 보이는 환자에서 digital guided tooth preparation을 이용한 완전 구강 회복 증례)

  • Kim, Yong-Kyu;Yeo, In-Sung Luke;Yoon, Hyung-In;Lee, Jae-Hyun;Han, Jung-Suk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.1
    • /
    • pp.80-90
    • /
    • 2022
  • With the development of digital dentistry, it is being applied in various ways of dental treatment. This case report presents the definitive prosthesis designed in advance with a re-established vertical dimension and the digital technology, which determined the amount of tooth preparation, in order to preserve as much tooth structure as possible in a patient with pathological wear of the posterior teeth and loss of vertical dimension. For accurate tooth preparation, the guides of the occlusal and axial surfaces were digitally and additively manufactured. Then, aesthetics and anterior guidance were established at the provisional stage. The information of the provisional restoration was delivered to the definitive stage by double scanning. The digital technology, including the virtual planning and the guided tooth removal, produced the definitive restorations satisfactory to both the patient and clinician.

Guidance and rationale for the immediate implant placement in the maxillary molar

  • Kezia Rachellea Mustakim;Mi Young Eo;Ju Young Lee;Hoon Myoung;Mi Hyun Seo;Soung Min Kim
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.49 no.1
    • /
    • pp.30-42
    • /
    • 2023
  • Objectives: While the reliability of immediate implant placement in the maxillary molar has been discussed, its significance is questionable. There have been no guidelines for case selection and surgical technique for successful treatment outcomes of immediate maxillary molar implants. Therefore, in this study, we classified alveolar bone height and socket morphology of the maxillary molar to establish guidelines for immediate implant placement. Materials and Methods: From 2011 to 2019, we retrospectively analyzed 106 patients with 148 immediate implants at the Department of Oral and Maxillofacial Surgery, Seoul National University Dental Hospital. Inclusion and exclusion criteria were applied, and patient characteristics and treatment results were evaluated clinically and radiologically. Results: A total of 29 tapered, sand-blasted, large-grit, and acid-etched (SLA) surfaces of implants were placed in 26 patients. The mean patient age was 64.88 years. Two implants failed and were reinstalled, resulting in a 93.10% survival rate. Fluctuating marginal bone level changes indicating bone regeneration and bone loss were observed in the first year following installation and remained stable after one year of prosthesis loading, with an average bone loss of 0.01±0.01 mm on the distal side and 0.03±0.03 mm on the mesial side. Conclusion: This clinical study demonstrated the significance of immediate implant placement in maxillary molars as a reliable treatment with a high survival rate using tapered SLA implants. With an accurate approach to immediate implantation, surgical intervention and treatment time can be reduced, resulting in patient satisfaction and comfort.