• Title/Summary/Keyword: accurate mass

Search Result 869, Processing Time 0.024 seconds

Feasibility Study of Isotope Ratio Analysis of Individual Uranium-Plutonium Mixed Oxide Particles with SIMS and ICP-MS

  • Esaka, Fumitaka;Magara, Masaaki;Suzuki, Daisuke;Miyamoto, Yutaka;Lee, Chi-Gyu;Kimura, Takaumi
    • Mass Spectrometry Letters
    • /
    • v.2 no.4
    • /
    • pp.80-83
    • /
    • 2011
  • Isotope ratio analysis of nuclear materials in individual particles is of great importance for nuclear safeguards. Although secondary ion mass spectrometry (SIMS) and thermal ionization mass spectrometry (TIMS) are utilized for the analysis of individual uranium particles, few studies were conducted for the analysis of individual uranium-plutonium mixed oxide particles. In this study, we applied SIMS and inductively coupled plasma mass spectrometry (ICP-MS) to the isotope ratio analysis of individual U-Pu mixed oxide particles. In the analysis of individual U-Pu particles prepared from mixed solution of uranium and plutonium standard reference materials, accurate $^{235}U/^{238}U$, $^{240}Pu/^{239}Pu$ and $^{242}Pu/^{239}Pu$ isotope ratios were obtained with both methods. However, accurate analysis of $^{241}Pu/^{239}Pu$ isotope ratio was impossible, due to the interference of the $^{241}Am$ peak to the $^{241}Pu$ peak. In addition, it was indicated that the interference of the $^{238}UH$ peak to the $^{239}Pu$ peak has a possibility to prevent accurate analysis of plutonium isotope ratios. These problems would be avoided by a combination of ICP-MS and chemical separation of uranium, plutonium and americium in individual U-Pu particles.

Comparison of QuEChERS and Solid Phase Extraction for Accurate Determination of Pesticide Residues in Kimchi Cabbage and Strawberry using Isotope Dilution Mass Spectrometry

  • Seonghee Ahn;Kebede Gebeyehu Mekete;Byungjoo Kim
    • Mass Spectrometry Letters
    • /
    • v.14 no.4
    • /
    • pp.178-185
    • /
    • 2023
  • QuEChERS is used worldwide as a universal sample preparation method with many benefits, such as being quick, easy, cheap, effective, rugged and safe. This study examined whether QuEChERS can be employed in isotope dilution mass spectrometry (ID-MS) for accurate analysis of pesticides in food. The ratios of fortified values and measured values of malathion and fenitrothion using the QuEChERS method were compared with those using the solid phase extract (SPE) method which was previously used in this laboratory. The separations of the two pesticides on DB-5MS and VF-1701MS columns were compared. Malathion and fenitrothion were fortified into kimchi cabbage and pretreated with the QuEChERS method and the SPE method. The results obtained using the DB-5MS column varied according to the sample preparation method, column and pesticide level. Using the VF-1701 column, ratios were 98-102% by both QuEChERS and Carb/NH2 SPE method for all fortification level. Malathion and fenitrothion were fortified into strawberry samples for comparison with kimchi cabbage. The results for the strawberry samples indicated that the ratios were not influenced by the sample preparation methods or GC column. The QuEChERS method could be acceptable in the ID-MS method for pesticide residue analysis in food, however other conditions should be carefully considered for accurate determination, such as the column, amount of analyte and food matrix.

Engine Modeling and Validation for Control System Design of a Gaseous-fuel Engine (기체연료엔진의 제어시스템 설계를 위한 엔진 모델링 및 검증)

  • 심한섭;선우명호
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.11 no.1
    • /
    • pp.7-17
    • /
    • 2003
  • Highly accurate control of an air-fuel ratio is very important to reduce exhaust gas emissions of gaseous-fuel engines. In order to achieve this purpose, a precise engine model is required to estimate engine performance from the engine design process which is applied to the design of an engine controller. Engine dynamics are considered to develop a dynamic engine model of a gaseous-fuel engine. An effective air mass ratio is proposed to study variations of the engine dynamics according to the water vapor and the gaseous-fuel in the mixture. The dynamic engine model is validated with the LPG engine under steady and transient operating conditions. The experimental results in the LPG gaseous-fuel engine show that the estimation of the air flow and the air-fuel ratio based upon the effective air mass ratio is more accurate than that of a normal engine model.

Application of a Strip Speed Measurement for Hot Strip Rolling (열연 사상압연공정 스탠드간 열연판속도 측정시스템 적용연구)

  • 홍성철;최승갑
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.212-212
    • /
    • 2000
  • This study was performed to construct a hot strip speed measuring system and check over whether the measured speed can be used for improving the mass flow of the head-end part of a hot strip in the 7-stand finishing mill. Because the mass flow in hot rolling mill affects the looper operation and the thickness and width control of a strip, accurate measurement of strip speed ie important. The measured speed was compared with the roll speeds of No. 6 and No.7 stand to check the performance of the system and analyzed to find how to apply the speed. As a result, it is shown that the accuracy of the system is enough, strip thickness error can be reduced by -275∼+200$\mu\textrm{m}$ using the measured speed and the existing FSU model has low accuracy for predicting forward slip rate. A neural network was developed to calculate forward slip rate instead of FSU model. The test result of the neural network shows that the neural network is more accurate than the FSU model.

  • PDF

Applications of MALDI-TOF Mass Spectrometry in Clinical Microbiology

  • Shin, Kyeong Seob;Yum, Jonghwa
    • Biomedical Science Letters
    • /
    • v.28 no.3
    • /
    • pp.145-156
    • /
    • 2022
  • Over the past few decades, few technologies have had a greater impact on clinical microbiology laboratories than matrix-assisted laser desorption time-of-flight mass spectrometry (MALDI-TOF MS). The MALDI-TOF MS is a fast, accurate, and low-cost and efficient method of microbial identification. This technology generates characteristic mass spectral fingerprints that is a unique signature for each microorganism, making it an ideal method for accurate identification at the genus and species levels of both bacterial and fastidious microorganism such as anaerobes, mycobacterium and fungi etc. In addition, MALDI-TOF MS has been successfully used in microbial subtyping and susceptibility tests such as determination of resistance genes. In this study, the authors summarized the application of MALDI-TOF MS in clinical microbiology and clinical research and explored the future of MALDI-TOF MS.

3-D Vibration Analysis of Floating Structures Like Ships Using FEM-BEM

  • Kim, Byung-Hyun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1990.10a
    • /
    • pp.107-112
    • /
    • 1990
  • In the vibration analysis of structure in fluid such as ships and offshore structures, the hydrodynamic added mass considerably affects the result of analysis. Therefore correct evaluation of the hydrodynamic added mass effect is required for an accurate analysis. But the correct evaluation of the effect is not simple because the added mass varies with the mode shape of vibration as well as the configuration of the structure. The universal method employed to evaluate added mass in ship hull vibration is Lewis's method via the introduction of 3 dimensional correction factor. But this conventional method is valid only for beam-like vibration.

  • PDF

SMOLED equipment for Mass-production

  • Kim, Chang-Woo;Cho, Woo-Seok;Kim, Dong-Soo;Bae, Kyung-Bin
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2002.08a
    • /
    • pp.133-136
    • /
    • 2002
  • It is very important to get a stable and large-capacity organic effusion source for achievement of OLED mass-production equipment. We present an organic effusion source with film uniformity less than ${\pm}$ 5%, the material charge volume, 300cc for $400{\times}400\;mm^2$ substrate. The fine metal shadow mask alignment technology, one of the color forming technique, also have to support more accurate and fast operating in mass-production. In this paper, we will describe the OLED mass-production equipment with the large volume effusion source and the precision shadow mask alignment technique.

  • PDF

Unusual Applications of Kendrick Plots: Recalibration and Tolerance

  • Thierry N. J. Fouquet;Orlando Cabarcos
    • Mass Spectrometry Letters
    • /
    • v.14 no.4
    • /
    • pp.173-177
    • /
    • 2023
  • Kendrick plots offer an alternative visualization of mass spectral data which reveals ion series and patterning by turning a mass spectrum into a map, plotting the fractional mass (wrongly called mass defect) as a function of mass-to-charge ratios and ion abundances. Although routinely used for polymer mass spectrometry, two unreported applications of these Kendrick plots are proposed using the program "kendo2": the graphical recalibration of a mass spectrum via the simulation of a theoretical fractional mass and a multi-segment fit; and the rapid evaluation of scan-to-scan variation of accurate mass measurements used as tolerances for the blank subtraction of UPLC-MS data files. Both applications are compatible with any type of high-resolution MS data including LC/GC-MS(/MS).

An Engine Model of a Heavy-Duty Compressed Natural Gas Engine for Design of an Air-Fuel Ratio Controller (대형천연가스차량의 공연비제어기 설계를 위한 엔진모델)

  • 심한섭;이태연
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.12 no.5
    • /
    • pp.80-87
    • /
    • 2003
  • Air partial pressure ratio and inlet air mass flow are influenced by water vapor and gaseous fuel in mixture on Compressed Natural Gas (CNG) engines. In this paper, the effects of the water vapor and the gaseous fuel that change the air mass flow and the air-fuel ratio are studied. Effective air mass ratio is defined as the air mass flow divided by mixture mass flow, and also it is applied to the estimation of the inlet air mass flow and the air-fuel ratio. The presence of the gaseous fuel and the water vapor in the mixture reduces the air partial pressure and the effective air mass ratio of the CNG engines. The experimental results for the CNG engine show that estimation of the air-fuel ratio based upon the effective air mass ratio is more accurate than that of a normal mode.

Development of Thermal Mass Flow Meter (열전달 질량유량계 개발)

  • Chi, Daesung
    • 유체기계공업학회:학술대회논문집
    • /
    • 1999.12a
    • /
    • pp.118-122
    • /
    • 1999
  • Thermal mass flow meter was developed using principle of convective heat transfer. The advantage of thermal mass flow meter is measuring mass flow directly, therefore, it is not required to use densitometer or temperature/pressure and DP gages. The final accuracy of this thermal mass flow meter is $\pm1.0{\%}$ or better, reproducibility is $\pm0.2{\%}$, and the response time is 600 ms. The thermal mass flow meter was developed from a single point to multi-points (maximum is 9 points), and the number of points is determined according to desired accuracy and size of piping/duct. Since this thermal mass flow meter adopted microprocessor based design, it is intrinsically accurate, self-error detectable, and has self-diagnosis function. The applications of this thermal mass flow meter are for measurement and control of HVAC air flow, other gas flow, and liquid flow.

  • PDF