• Title/Summary/Keyword: accuracy test

Search Result 4,873, Processing Time 0.036 seconds

Location error analysis of a real time locating system in a multipath environment (다중경로 환경에서 실시간 위치추적 시스템의 위치 오차 분석)

  • Myong, Seung-Il;Mo, Sang-Hyun;Lee, Heyung-Sub;Park, Hyung-Rae;Seo, Dong-Sun
    • Journal of IKEEE
    • /
    • v.14 no.1
    • /
    • pp.25-32
    • /
    • 2010
  • In this paper, we analyze the location accuracy of real-time locating systems (RTLS) in multipath environments, where the RTLS complies with an ISO/IEC 24730-2 international standard. RTLS readers should have an ability not only to recover the transmitted signal but also provide arrival timing information from the received signal. In the multipath environments, in general, the transmitted signal goes through both direct and indirect paths, and then it becomes some distorted form of the transmitted signal. Such multipath components have a critical effect on deciding the first arrival timing of the received signal. To analyze the location error of the RTLS in the multipath environments, we assume two multipath components without considering an additive white Gaussian noise. Through the simulation and real test results, we confirm that the location error does not occur when the time difference between two paths is more than 1.125Tc, but the location error of about 2.4m happens in case of less than 0.5Tc. In particular, we see that the resolvability of two different paths depends largely on the phase difference for the time difference of less than 1Tc.

Study on the Calibration of a Full-Polarimetric Scatterometer System at X-band (X-밴드 완전 편파 Scatterometer 시스템 보정에 관한 연구)

  • Hwang, Ji-Hwan;Park, Seong-Min;Kwon, Soon-Gu;Oh, Yi-Sok
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.4
    • /
    • pp.408-416
    • /
    • 2010
  • A study on the calibration of an X-band HPS(Hongik Polarimetric Scatterometer) system for ground-based operation is presented in this paper. In order to calibrate the scatterometer system, the degree of its distortions are analyzed by comparison between theoretical- and measured-values using the theoretically well-known calibration targets such as a metal sphere, a trihedral corner reflector(CR) and a metal cylinder. The calibration works in the field conditions depend on the precise and stable measurements of those calibration target. we present a measurement technique, so-called, an automatic 2-D target-scanning technique, using the incidence-angle(${\xi}-$ and ${\phi}-$ directions) control of HPS system. Then, we used STCT(Single-Target Calibration Technique) and GCT(General Calibration Technique) to calibrate a distortion of the scatterometer system, and measured the polarimetric RCS(Radar Cross Section) and phase-difference of a trihedral-CR as a test-target to verify the accuracy of the calibration technique. Then, three different types(i.e., 10, 20, 30 cm) of trihedral-CR were used. we obtained the error ranges about ${\pm}1.0$dB, ${\pm}0.5$ dB in a polarimetric RCS and about $-20^{\circ}{\sim}0^{\circ}$ and ${\pm}5^{\circ}$ in the co-polarized phase-difference by using the GCT and STCT, respectively.

A Study of $^{222}Rn\;and\;^{226}Ra$ Analysis in the Groundwater by LSC (액체섬광계수기에 의한 지하수중의 $^{222}Rn$$^{226}Ra$ 분석법 연구)

  • Woo, Hyung-Joo;Yoon, Yoon-Yeol;Cho, Soo-Young;Chun, Sang-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.20 no.4
    • /
    • pp.275-283
    • /
    • 1995
  • PERALS(Photon Electron Rejecting Alpha Liquid Scintillation) spectrometry coupled with solvent extraction method has been set up for the analysis of $^{222}Rn\;and\;^{226}Ra$ in the groundwater. This analytical method offers low background, better energy resolution and lower quenching problem than the other techniques. By the analysis of NIST SRM 4966 $^{226}Ra$ standard, the analytical accuracy and precision were found to be 3% and 1%, respectively, and the relative standard deviation of the recovery of Rn extraction between pH2 and pH10 was 7%. Detection limits of $^{222}Rn$ and $^{226}Ra$ for 10 hours counting were counted to be $0.42 pCi/{\iota}\;and\;0.016 pCi/{\iota}$, respectively. For the test analysis of $^{222}Rn\;and\;^{226}Ra$ in the graundwater, hot spring water samples of 17 regions were analyzed. The concentration of $^{222}Rn$ were in the range of $90{\sim}5200pCi/{\iota}$ and average value was $1470pCi/{\iota}\;^{226}Ra$ concentration showed a peak value of $97.9pCi/{\iota}$ in a Kangwon region, but the average value was $1.14pCi/{\iota}$ except that region.

  • PDF

Prediction of Stand Volume and Carbon Stock for Quercus variabilis Using Weibull Distribution Model (Weibull 분포 모형을 이용한 굴참나무 임분 재적 및 탄소저장량 추정)

  • Son, Yeong Mo;Pyo, Jung Kee;Kim, So Won;Lee, Kyeong Hak
    • Journal of Korean Society of Forest Science
    • /
    • v.101 no.4
    • /
    • pp.599-605
    • /
    • 2012
  • The purpose of this study is to estimate diameter distribution, volume per hectare, and carbon stock for Quercus variabilis stand. 354 Quercus variabilis stands were selected on the basis of age and structure, the data and samples for these stands are collected. For the prediction of diameter distribution, Weibull model was applied and for the estimation of the parameters, a simplified method-of-moments was applied. To verify the accuracy of estimates, models were developed using 80% of the total data and validation was done on the remaining 20%. For the verification of the model, the fitness index, the root mean square error, and Kolmogorov-Smirnov statistics were used. The fitness index of the site index, height, and volume equation estimated from verification procedure were 0.967, 0.727, and 0.988 respectively and the root mean square error were 2.763, 1.817, and 0.007 respectively. The Kolmogorov-Smirnov test applied to Weibull function resulted in 75%. From the models developed in this research, the estimated volume and above-ground carbon stock were derived as $188.69m^3/ha$, 90.30 tC/ha when site index and stem number of 50-years-old Quercus variabilis stand show 14 and 697 respectively. The results obtained from this study may provide useful information about the growth of broad-leaf species and prediction of carbon stock for Quercus variabilis stand.

Estimation of carcass weight of Hanwoo (Korean native cattle) as a function of body measurements using statistical models and a neural network

  • Lee, Dae-Hyun;Lee, Seung-Hyun;Cho, Byoung-Kwan;Wakholi, Collins;Seo, Young-Wook;Cho, Soo-Hyun;Kang, Tae-Hwan;Lee, Wang-Hee
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.33 no.10
    • /
    • pp.1633-1641
    • /
    • 2020
  • Objective: The objective of this study was to develop a model for estimating the carcass weight of Hanwoo cattle as a function of body measurements using three different modeling approaches: i) multiple regression analysis, ii) partial least square regression analysis, and iii) a neural network. Methods: Data from a total of 134 Hanwoo cattle were obtained from the National Institute of Animal Science in South Korea. Among the 372 variables in the raw data, 20 variables related to carcass weight and body measurements were extracted to use in multiple regression, partial least square regression, and an artificial neural network to estimate the cold carcass weight of Hanwoo cattle by any of seven body measurements significantly related to carcass weight or by all 19 body measurement variables. For developing and training the model, 100 data points were used, whereas the 34 remaining data points were used to test the model estimation. Results: The R2 values from testing the developed models by multiple regression, partial least square regression, and an artificial neural network with seven significant variables were 0.91, 0.91, and 0.92, respectively, whereas all the methods exhibited similar R2 values of approximately 0.93 with all 19 body measurement variables. In addition, relative errors were within 4%, suggesting that the developed model was reliable in estimating Hanwoo cattle carcass weight. The neural network exhibited the highest accuracy. Conclusion: The developed model was applicable for estimating Hanwoo cattle carcass weight using body measurements. Because the procedure and required variables could differ according to the type of model, it was necessary to select the best model suitable for the system with which to calculate the model.

Dosimetric Validation of the Acuros XB Advanced Dose Calculation Algorithm for Volumetric Modulated Arc Therapy Plans

  • Park, So-Yeon;Park, Jong Min;Choi, Chang Heon;Chun, Minsoo;Kim, Jung-in
    • Progress in Medical Physics
    • /
    • v.27 no.4
    • /
    • pp.180-188
    • /
    • 2016
  • Acuros XB advanced dose calculation algorithm (AXB, Varian Medical Systems, Palo Alto, CA) has been released recently and provided the advantages of speed and accuracy for dose calculation. For clinical use, it is important to investigate the dosimetric performance of AXB compared to the calculation algorithm of the previous version, Anisotropic Analytical Algorithm (AAA, Varian Medical Systems, Palo Alto, CA). Ten volumetric modulated arc therapy (VMAT) plans for each of the following cases were included: head and neck (H&N), prostate, spine, and lung. The spine and lung cases were treated with stereotactic body radiation therapy (SBRT) technique. For all cases, the dose distributions were calculated using AAA and two dose reporting modes in AXB (dose-to-water, $AXB_w$, and dose-to-medium, $AXB_m$) with same plan parameters. For dosimetric evaluation, the dose-volumetric parameters were calculated for each planning target volume (PTV) and interested normal organs. The differences between AAA and AXB were statistically calculated with paired t-test. As a general trend, $AXB_w$ and $AXB_m$ showed dose underestimation as compared with AAA, which did not exceed within -3.5% and -4.5%, respectively. The maximum dose of PTV calculated by $AXB_w$ and $AXB_m$ was tended to be overestimated with the relative dose difference ranged from 1.6% to 4.6% for all cases. The absolute mean values of the relative dose differences were $1.1{\pm}1.2%$ and $2.0{\pm}1.2%$ when comparing between AAA and $AXB_w$, and AAA and $AXB_m$, respectively. For almost dose-volumetric parameters of PTV, the relative dose differences are statistically significant while there are no statistical significance for normal tissues. Both $AXB_w$ and $AXB_m$ was tended to underestimate dose for PTV and normal tissues compared to AAA. For analyzing two dose reporting modes in AXB, the dose distribution calculated by $AXB_w$ was similar to those of AAA when comparing the dose distributions between AAA and $AXB_m$.

Development of penetration rate model and optimum operational conditions of shield TBM for electricity transmission tunnels (터널식 전력구를 위한 순굴진율 모델 개발 및 이를 활용한 쉴드TBM 최적운전 조건 제안)

  • Kim, Jeong-Ju;Ryu, Hui-Hwan;Kim, Gyeong-Yeol;Hong, Seong-Yeon;Jeong, Ju-Hwan;Bae, Du-San
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.22 no.6
    • /
    • pp.623-641
    • /
    • 2020
  • About 5 km length of tunnels were constructed by mechanized tunnelling method using closed type shield TBM. In order to avoid construction delay problems for ensuring timely electricity transmission, it is necessary to increase the prediction accuracy of the excavation process involving machines according to rock mass types. This is important to corroborate the project duration and optimum operation for various considerations involved in the machine. So, full-scale tunnelling tests were performed for developing the advance rate model to be appropriately used for 3.6 m diameter shield TBM. About 100 test cases were established and performed using various operational parameters such as thrust force and rotational speed of cuttterhead in representative uniaxial compressive strengths. Accordingly, relationships between normal force and penetration depth and, between UCS and torque were suggested which consider UCS and thrust force conditions according to weathered, soft, hard rocks. Capacity analysis of cutterhead was performed and optimum operational conditions were also suggested based on the developed model. Based on this study, it can be expected that the project construction duration can be reduced and users can benefit from the provision of earlier service.

Study on the Development of Wet Cell Holder for the Measurement of Hydrophilic Contact Lens (친수성 콘택트렌즈 측정용 Wet Cell 홀더 개발에 관한 연구)

  • Song, Kyoung-Sek;Lim, Hyeon-Sun;Joo, Seok-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.4
    • /
    • pp.455-462
    • /
    • 2015
  • Purpose: To develop more accurate wet measuring system combining the wet cell, automatic lensmeter and the related software for hydrophilic contact lenses and to verify the accuracy of those measuring holder system already available in the market. Methods: Refractive power measurement were done in both a conventional method which has been commonly used in optical shops and a new method which is recently developed in korea. Hydrophilic contact lens of korean brand was chosen as a test material and was tested by water content ratio and by spherical refractive power. Results: When spherical power of -3.00 D contact lens is measured in the newly developed wet cell measurement holder with automatic lensmeter, it reads -3.01 D at water content ratio of 38%. -3.00 D at 45% and -2.98 D at 58%. The same experiment with the Poster soft contact lens wet cell measurement holder maintaining other conditions same resulted in -3.60 D at the water content ratio of 38%, -3.06 D at 45% and -2.46 D at 58%. Conclusions: At the higher water content, the refractive power values measured by both of the wet cell measuring holders are shown lower, and additionally, the new method using the wet cell holder and new software program in a automatic lensmeter showed more accurate readings than conventional Poster soft contact lens wet cell measuring system.

Assessing Distress Prediction Model toward Jeju District Hotels (제주지역 호텔기업 부실예측모형 평가)

  • Kim, Si-Joong
    • The Journal of Industrial Distribution & Business
    • /
    • v.8 no.4
    • /
    • pp.47-52
    • /
    • 2017
  • Purpose - This current study will investigate the average financial ratio of top and failed five-star hotels in the Jeju area. A total of 14 financial ratio variables are utilized. This study aims to; first, assess financial ratio of the first-class hotels in Jeju to establishing variables, second, develop distress prediction model for the first-class hotels in Jeju district by using logit analysis and third, evaluate distress prediction capacity for the first-class hotels in Jeju district by using logit analysis. Research design, data, and methodology - The sample was collected from year 2015 and 14 financial ratios of 12 first-class hotels in Jeju district. The results from the samples were analyzed by t-test, and the independent variables were chosen. This was an empirical study where the distress prediction model was evaluated by logit analysis. This current research has focused on critically analyzing and differentiating between the top and failed hotels in the Jeju area by utilizing the 14 financial ratio variables. Results - The verification result of the accuracy estimated by logit analysis has shown to indicate that the distress prediction model's distress prediction capacity was 83.3%. In order to extract the factors that differentiated the top hotels in the Jeju area from the failed hotels among the 14 chosen, the analysis of t-black was utilized by independent variables. Logit analysis was also used in this study. As a result, it was observed that 5 variables were statistically significant and are included in the logit analysis for discernment of top and failed hotels in the Jeju area. Conclusions - The distress prediction press' prediction capability was compared in this research analysis. The distress prediction press prediction capability was shown to range from 75-85% by logit analysis from a previous study. In this current research, the study's prediction capacity was shown to be 83.33%. It was considered a high number and was found to belong to the range of the previous study's prediction capacity range. From a practical perspective, the capacity of the assessment of the distress prediction model in the top and failed hotels in the Jeju area was considered to be a prominent factor in applications of future hotel appraisal.

Structural Disambiguation using Mutual Information and the Measure of Confidence (상호 정보를 이용한 구조적 모호성 해소와 결과에 대한 확신도 측정)

  • 심광섭
    • Korean Journal of Cognitive Science
    • /
    • v.4 no.1
    • /
    • pp.153-176
    • /
    • 1993
  • Structual ambiguity is one of those problem that arise in the analysis of natural language sentences.It has been considered very difficult to solve the problem.Structural ambiguity,however,should be resolved no matter how difficult it may be.Otherwise natural language processing could be virtually impossible.A statistical approach to structural disambiguation is proposed in this dissertation.The information-theoretic concept of mutual information has been empolyed in resolving structural ambiguity Mutual information can be acquired in an automatic way.from text corpora. If a structural disambiguation subsystem had the capability of self-evaluating whether the results of structural disambiguation are correct or not.it would be possible to develop a more intelligent natural language proessing system.In this paper,the concept of confidence measure is also proposed to endow the disambiguation subsystem with such intelligence.Confidence measure is a numeric value calculated after structural disambiguation. Some experiments were performed in order to show the validity of the approach.Mutual information was auto matically acquired from a corpus of 1.6milion words that were collected from scientific abstracts.The accuracy of structural disambiguation was 80%when performed over 1,639 test sentences.Notice that there was no manual tuning in advance for the experiments.The task of detecting and correcting errors in structural disambiguation will be performed very effectively if the concept of confidence measure is employed in the process.