• Title/Summary/Keyword: accident distribution test

Search Result 64, Processing Time 0.028 seconds

Partial Discharge Distribution Characteristics along Defect of CNC Cable (배전급 CNC케이블의 결함 종류에 따른 부분방전 분포특성)

  • Yoon, Jae-Hun;Kang, Seung-Hwa;Choi, Han-Sick;Lim, Gee-Jo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.102-102
    • /
    • 2010
  • A purpose of this paper is to recognize partial discharge pattern for cable insulation. The classification of PD sources was widely studied for two decades. this research sought to use the partial discharge detection method, and to diagnose the interface of cable, which is deemed vulnerable of cable systems. A research abalyzed faults that can occur in the interface of cable joint as well as accident mechanisms, manufactured test 22.9kV CNC cable, invented artificial faults and carried out partial discharge detection experiments. As a result, various PD pattern along defect measured and distinguished.

  • PDF

The Plan of Safety for Pump Station through Hydraulic Transient Analysis & Demonstration (과도수리현상 해석과 실증을 통한 펌프장 안정성 확보방안)

  • Ra, Beyong-pil;Kim, Jin-man;Park, Jong-ho;Kim, Kyung-yup
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.199-207
    • /
    • 2004
  • Water supply facilities are recently getting larger according as domestic waterworks become multi regional water supply system. Large water supply facilities generally consist of the intake pumping station, water treatment station and water supply & distribution facilities. Although pumping stations and pipeline systems are used to pump up water, it often happens pipeline damage and flooding accident by the water hammer. As a result of this study, a pumping station is guaranteed by the computer simulation and field test analysis. Therefore these are contributed safety operation in pumping station through adjustment of the pumping station safety plan, air valve and valve closing time.

  • PDF

Experiments on Sedimentation of Particles in a Water Pool with Gas Inflow

  • Kim, Eunho;Jung, Woo Hyun;Park, Jin Ho;Park, Hyun Sun;Moriyama, Kiyofumi
    • Nuclear Engineering and Technology
    • /
    • v.48 no.2
    • /
    • pp.457-469
    • /
    • 2016
  • During the late phase of severe accidents of light water reactors, a porous debris bed is expected to develop on the bottom of the flooded reactor cavity after breakup of the melt in water. The geometrical configuration, i.e., internal and external characteristics, of the debris bed is significant for the adequate assessment of the coolability of the relocated corium. The internal structure of a debris bed was investigated experimentally using the DAVINCI (Debris bed research Apparatus for Validation of the bubble-Induced Natural Convection effect Issue) test facility. Particle sedimentation under the influence of a two-phase natural convection flow due to the decay heat in the debris bed was simulated by dropping various sizes of particles into a water vessel with air bubble injection from the bottom. Settled particles were collected and sieved to obtain the particle mass, size distribution in the radial and axial positions, and the bed porosity and permeability. The experimental results showed that the center part of the particle bed tended to have larger particles than the peripheral area. For the axial distribution, the lower layer had a higher fraction of larger particles. As the sedimentation progressed, the size distribution in the upper layers can shift to larger sizes because of the higher vapor generation rate and stronger flow intensity.

FISSION PRODUCT AND ACTINIDE RELEASE FROM THE DEBRIS BED TEST PHEBUS FPT4: SYNTHESIS OF THE POST TEST ANALYSES AND OF THE REVAPORISATION TESTING OF THE PLENUM SAMPLES

  • Bottomley P.D.W.;Gregoire A.C.;Carbol P.;Glatz J.P.;Knoche D.;Papaioannou D.;Solatie D.;Van Winckel S.;Gregoire G.;Jacquemain D.
    • Nuclear Engineering and Technology
    • /
    • v.38 no.2
    • /
    • pp.163-174
    • /
    • 2006
  • The $Ph{\acute{e}}bus$ FP project is an international reactor safety project. Its main objective is to study the release, transport and retention of fission products in a severe accident of a light water reactor (LWR). The FPT4 test was performed with a fuel debris bed geometry, to look at late phase core degradation and the releases of low volatile fission products and actinides. Post Test Analyses results indicate that releases of noble gases (Xe, Kr) and high-volatile fission products (Cs, I) were nearly complete and comparable to those obtained during $Ph{\acute{e}}bus$ tests performed with a fuel bundle geometry (FPT1, FPT2). Volatile fission products such as Mo, Te, Rb, Sb were released significantly as in previous tests. Ba integral release was greater than that observed during FPT1. Release of Ru was comparable to that observed during FPT1 and FPT2. As in other $Ph{\acute{e}}bus$ tests, the Ru distribution suggests Ru volatilization followed by fast redeposition in the fuelled section. The similar release fraction for all lanthanides and fuel elements suggests the released fuel particles deposited onto the plenum surfaces. A blockage by molten material induced a steam by-pass which may explain some of the low releases. The revaporisation testing under different atmospheres (pure steam, $H_2/N_2$ and steam /$H_2$) and up to $1000^{\circ}C$ was performed on samples from the first upper plenum. These showed high releases of Cs for all the atmospheres tested. However, different kinetics of revaporisation were observed depending on the gas composition and temperature. Besides Cs, significant revaporisations of other elements were observed: e.g. Ag under reducing conditions, Cd and Sn in steam-containing atmospheres. Revaporisation of small amounts of fuel was also observed in pure steam atmosphere.

Comparative analysis of internal flow characteristics of LBE-cooled fast reactor main coolant pump with different structures under reverse rotation accident conditions

  • Lu, Yonggang;Wang, Xiuli;Fu, Qiang;Zhao, Yuanyuan;Zhu, Rongsheng
    • Nuclear Engineering and Technology
    • /
    • v.53 no.7
    • /
    • pp.2207-2220
    • /
    • 2021
  • Lead alloy is used as coolant in Lead-based cooled Fast Reactor (LFR). The natural characteristics of lead alloy are combined with the simple structural design of LFR. This constitutes the inherent safety characteristics of LFR. The main work of this paper is to take the main coolant pump (MCP) in the lead-cooled fast reactor (LFR) as the research object, and to study the flow pattern distribution of the internal flow field under the reverse rotation pump condition, the reverse rotation positive-flow braking condition and the reverse rotation negative-flow braking condition. In this paper, the double-outlet volute type and the space guide vane are selected as the potential designs of the CLEAR-I MCP. In this paper, the CFD method is used to study the potential reverse accident of the MCP. It is found that the highest flow velocity in the impeller appears at the impeller outlet, and the Q-H curves of the two design programs basically coincide. The space guide vane type MCP has better hydraulic performance under the reverse rotation positive-flow condition, the Q-H curves of the two designs gradually separate with increasing flow rate, and the maximum flow velocity inside the space guide vane type MCP is obviously lower than that of the double-outlet volute type. For the reverse rotation test of MCP, only the condition of the forward rotating pump of the main coolant pump is tested and verified. For the simulation of the MCP in LBE medium, it proved that the turbulence model and basic settings selected in the simulation are reliable.

Risk Assessment of Integrated Leak Rate Test(ILRT) Extension for Korea Standard Nuclear Power Plant (한국표준형원전의 격납건물종합누설률 시험 주기연장에 대한 리스크 평가)

  • Chi, Moon-Goo;Hwang, Seok-Won;Oh, Ji-Yong
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.5
    • /
    • pp.99-104
    • /
    • 2011
  • An ILRT Interval for a nuclear power plant in Korea was extended from once in five years to once in ten years. Therefore, it is necessary to evaluate risk impact for ILRT interval extensions. In this paper, input data were generated for the reference plants, KSNP, using raw data such as meteorological data, population distribution data and source term data. And, using MACCS II code the risk impact assessment was performed based on the two methodologies of NUREG-1493 and NEI Interim Report. The risk impact derived from an ILRT interval extension was identified not to be significant. It is considered to apply this study and results to making an accident management plan and safety goal, and to the field of public acceptance.

The Thermal Analysis of Pole Mount Mold Transformer with One-body Molding by Duct Condition (일체형 주상용 몰드변압기의 덕트에 따른 열해석 특성 연구)

  • Cho, Han-Goo;Lee, Un-Yong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07b
    • /
    • pp.1135-1138
    • /
    • 2003
  • The transformer is major equipment in power receiving and substation facilities. Necessary conditions required for the transformer are compactness, lightness, high reliability, economic advantages, and easy maintenance. The pole-mount transformer installed in distribution system is acting direct role in supply of electric power and it is electric power device should drive for long term. Most of modem transformer are oil-filled transformer and accident is happening considerable. The mold transformers have been widely used in underground substations in large building and have some advantages in comparison to oil-transformer, that is low fire risk, excellent environmental compatibility, compact size and high reliability. In addition, the application of mold transformer for outdoor is possible due to development of epoxy resin. The mold transformer generally has cooling duct between low voltage coil and high voltage coil. A mold transformer made by one body molding method has been developed for small size and low loss. One body molding transformer needs some cooling method because heat radiation between each winding is difficult. In this paper, The thermal analysis of pole mount mold transformer with one body molding by duct condition is investigated and the test result of temperature rise is compared with simulation data.

  • PDF

A Study on Distribution of Cs-137 and Sr-90 in Soils around Taejon Region (대전지역 토양에 대한 Cs-137 및 Sr-90 방사능농도 분포 조사)

  • Lee, Myung-Ho;Lee, Chang-Woo;Hong, Kwang-Hee;Choi, Yong-Ho;Kim, Sang-Bok;Park, Doo-Won;Lee, Jeong-Ho
    • Journal of Radiation Protection and Research
    • /
    • v.20 no.2
    • /
    • pp.123-128
    • /
    • 1995
  • The concentration of Cs-137 and Sr-90 has been analyzed in soils around Taejon region. A correalation was found between the concentration of Cs-137 and the organic matter content. The mean value of Cs-137 was 14.37Bq/kg-dry and that of Sr-90 was 7.95Bq/kg-dry in undisturbed soils around Taejon region. The concentration ratio of Cs-137/Sr-90 was 1.99. The distribution of Cs-137 and Sr-90 was similar to cumulative fallout level and had been more affected by nuclear weapons test than by the chernobyl accident.

  • PDF

A Study on the Application of Sulfur-Free Odorant for LPG Fuel (LPG 연료용 비황분계 부취제의 적용성 연구)

  • Kim, Jae-Kon;Yim, Eui Soon;Jung, Choong-Sub
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.5
    • /
    • pp.52-59
    • /
    • 2014
  • In general, sulfur containing odorants are added to fuel gases, such as LPG, and city gas, to prevent gas poisoning, ignition, explosion, or other accident caused by fuel gases, and to enable immediate and easy detection of fuel-gas leakage by emitting an offensive smell. In this study, sulfur free odorant for low sulfur fuel and prevention of metal corrosion were developed to replace current sulfur containing odorant for gas fuel. They were selected from 12 odorant containing non-sulfur organic compounds and evaluated by odor olfactory method (odor quality, odor intensity). Finally, selected mixture odorants were methyl isovalerate, methyl acrylate, 2-ethyl-3-methyl pyrazine with blending ratio of 50% : 40% : 10%. Final Sulfur free odorant was added 40 wt ppm in LPG fuels and evaluated fuel quality characteristics, metal corrosion test and long term stability of LPG fuel. It were limit in current LPG fuel standard in fuel quality characteristics. Final Sulfur free odorant also had no influence on metal corrosion and long term stability test with 60 days by adding in LPG fuels. Finally, they were shown to be warning agent candidates to reduce sulfur content and metal corrosion for LPG fuel.

Drivers' Workloads through the Driving Vehicle Test at Intersections (교차로 실차주행 실험을 통한 운전자 부하요인에 관한 연구)

  • Seo, Im-Ki;Park, Je-Jin;Sung, Soo-Lyeon;NamGung, Moon
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.11 no.3
    • /
    • pp.112-123
    • /
    • 2012
  • Different from general roads, intersections are the points where roads having different geometric structure and traffic operation system are met, and thereby they have complicated road structure and environmental factors. Various changes in driving patterns such as collision between vehicles approaching from roads adjacent to intersections, sudden stop of vehicles upon stop sign, quick start upon green lights kept increasing traffic accidents. It is known that traffic accidents are mainly derived from human factors. This study, in order to find out factors affecting drivers' behaviors within intersections, measured physiological responses such as brain wave, sight, driving speed, and so on by using state-of-the-art measuring device. As to concentration brain wave at individual intersections, it was found out that brain wave of testes was higher at main Arterial and accident-prone intersections compared with that of subsidiary Arterial. In addition, it was detected that drivers' visual activity was widely distributed at accident-prone intersections, meaning that it enhanced cautious driving from nearby vehicles. As to major factors causing drivers' workloads, factors from nearby vehicles such as deceleration, acceleration, lane change of nearby vehicles appeared as direct factors causing drivers' workloads, clarifying that these factors were closely related to causes of traffic accidents at intersections. Results of this study are expected to be used as basic data for evaluation of safety at intersections in consideration of physiological response of drivers.