• Title/Summary/Keyword: access probe

Search Result 47, Processing Time 0.024 seconds

Improvement of the access channel algorithm in the CDMA2000 system (CDMA2000시스템에 있어서 액세스채널 알고리즘 개선)

  • Lee Kwang jai;Chun Jong hun;Park Jong an
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.3B
    • /
    • pp.138-143
    • /
    • 2005
  • This paper aims to optimize an access probe algorithm for the CDMA 2000 system. The incremental value of PWR_STEP increases as NUM_STEP as 1dBm±0.2 for access probe of the area with good receiving sensitivity when the mobile station transmits via access channel and does not receive any ACK message. However, for the area with weak receiving sensitivity, according to the algorithm of open-loop power control, the transmitting power amplifier becomes saturated and PWR_STEP incremental value keeps performing access probe to 0dBm±0.2. Therefore interference and battery consumption increases according to the transmission of the mobile station. We have optimized the access probe algorithm according to the receiving sensitivity. We transmit the incremental value of access probe power, with delaying as much RT slot value as indicated by IS-95C standard in case of good receiving sensitivity and with delaying RT+l slot value in case of weak receiving sensitivity. Simulation results showed that the proposed algorithm contributes to decrease of the interference and battery consumption according to the transmitting power of the mobile station and improves the call duration.

Analysis of OPEN LOOP Power Control in CDMA Reverse Link (CDMA 역방향 링크에서 OPEN LOOP 전력제어 알고리즘 분석)

  • 이철희;박종안
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.22 no.4
    • /
    • pp.804-811
    • /
    • 1997
  • In the CDMA mobile communication system, reverse power control can be used to minimize the interference level for a good quality of the voice channel, and used to maxmize the system capacity. In this paper, we have analyed the environment of the K-parameter and the access procedure for the mobile station, and proposed a new algorithm for the access probe procedure of the station. K-parameter is determined according to the environment of the base station and access probe can adaptively control the power according to the position changes of the mobile station or the rapid and various state changes of the channel. Simulation results in the limited test environment show that it can increase the system capacity and decrease the power comsumption of the mobile station while maintaining the good and stable quality of the voice channel.

  • PDF

Optical and Mechanical Characteristics of NF System and NF Gap Control (근접장 광학계의 광학적 및 기계적 특성 분석과 근접장 간격제어)

  • Oh, Hyeong-Ryeol;Lee, Jun-Hee;Gweon, Dae-Gab;Kim, Soo-Kyung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.1528-1532
    • /
    • 2000
  • The conventional optics and near field optics are compared numerically in the view points of the spot size and propagation characteristics. The decaying characteristics of near field light require the optics to access the object within several tens of nanometers. Therefore the gap control is one of the main issues in the near field optics area. In this paper the gap control is done by using the shear force of the NF(Near Field) probe and the characteristics are examined. The probe is modeled as a 2'nd order mass-spring-damper system driven by a harmonic force. The primary cause of the decrease in vibration amplitude is due to the damping force - shear force - between the surface and the probe. Using the model, damping constant and resonance frequency of the probe is calculated as a function of probe-sample distance. Detecting the amplitude and phase shift of the NF probe attached to the high Q-factor piezoelectric tuning fork, we can control the position of the NF probe about 0 to 50nm above the sample. The feedback signal to regulate the probe-sample distance can be used independently for surface topography imaging. 3-D view of the shear force image of a testing sample with the period of $1{\mu}m$ will be shown.

  • PDF

Design and Performance Evaluation of Shear Wave Phased Array Ultrasonic Transducer (횡파 위상배열 초음파 탐촉자 설계 및 성능 평가)

  • Yoon, Byung-Sik;Lee, Hee-Jong;Braconnier, Dominique
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.2
    • /
    • pp.185-191
    • /
    • 2012
  • Typically, a wedge is involved to generate effectively high inspection angle in pipe weld inspection using phased array ultrasonic technique. But the usage of this wedge for weld or access limited area can cause coverage limitation for the examination volume because of the wedge front length. Therefore, the shear wave phased array probe which can generate high inspection angle without wedge is essentially necessary. In this paper, the shear wave phased array ultrasonic probe which can generate high inspection angle designed by modeling and manufactured from the modelling result. And this shear wave probe tested whether it can detect and sizing for EDM test block that contains various depth. As results, the experimental results show that the designed shear wave phased array probe can detect and size with reliable accuracy. Therefore if this phased array probe apply in field inspection, it is expected that it show more reliable inspection result for plant structure having access limitation.

Feasibility Study for Low Pressure Turbine Inspection of Nuclear Power Plant Using Shear Wave Phased Array Ultrasonic Transducer (횡파 위상배열 초음파탐촉자를 이용한 원자력발전소 저압 터빈 검사 적용 타당성 연구)

  • Yoon, Byung Sik;Kim, Yong Sik;Kim, Jin Hoi
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.9 no.1
    • /
    • pp.8-14
    • /
    • 2013
  • Steam turbine blades and discs of nuclear power plants are one of the most highly stressed areas of turbine rotor, and periodic inspection of the blade roots is essential for monitoring integrity and preventing turbine failure. Ultrasonic technique is applied for volumetric inspection of blade root. However, the complexity of blade root geometry imposes challenges to inspection of blades and discs. Recently, phased array ultrasonic inspection technology is being applied to numerous power generation inspection applications including turbine rotor. The phased array ultrasonic technique requires customized inspection wedges which are generally necessary to generate effectively higher incident angle. But the usage of this wedge can cause access limitation for the lower stage blades of turbine because of the wedge front length. Therefore, the shear wave phased array probe which can generate high inspection angle without wedge is essentially necessary. In this study, feasibility study is conducted for the shear wave phased array ultrasonic probe application to blade and disc inspection. As results, the experimental results show that the shear wave phased array probe can detect the flaw and measure its size with reliable accuracy. Therefore if this shear wave phased array probe is applied to field inspection of blade and disc, more reliable inspection is expected for turbine having access limitation.

Highly Productive Process Technologies of Cantilever-type Microprobe Arrays for Wafer Level Chip Testing

  • Lim, Jae-Hwan;Ryu, Jee-Youl;Choi, Woo-Chang
    • Transactions on Electrical and Electronic Materials
    • /
    • v.14 no.2
    • /
    • pp.63-66
    • /
    • 2013
  • This paper describes the highly productive process technologies of microprobe arrays, which were used for a probe card to test a Dynamic Random Access Memory (DRAM) chip with fine pitch pads. Cantilever-type microprobe arrays were fabricated using conventional micro-electro-mechanical system (MEMS) process technologies. Bonding material, gold-tin (Au-Sn) paste, was used to bond the Ni-Co alloy microprobes to the ceramic space transformer. The electrical and mechanical characteristics of a probe card with fabricated microprobes were measured by a conventional probe card tester. A probe card assembled with the fabricated microprobes showed good x-y alignment and planarity errors within ${\pm}5{\mu}m$ and ${\pm}10{\mu}m$, respectively. In addition, the average leakage current and contact resistance were approximately 1.04 nA and 0.054 ohm, respectively. The proposed highly productive microprobes can be applied to a MEMS probe card, to test a DRAM chip with fine pitch pads.

A Study on Smart Soil Resistance Measuring Device for Safety Characterized Ground Design in Converged Information Technology (ICT 융합 환경에서의 안전 특성화 접지 설계를 위한 스마트 대지 저항 측정 기술에 관한 연구)

  • Kim, Hong-Yong;Shin, Seung-Jung
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.1
    • /
    • pp.203-209
    • /
    • 2019
  • In this work, a new land-specific resistance measuring device (GM) and a measuring probe (Grounding Rod) are connected to the WENNER quadrant as power-line communication (PLC). In groups of two (P1,P2) probes, five to ten probes are installed in series on the ground at intervals of 1m, 2m, 4m, 8m, and 16m, respectively. If the PLC signal from the GMD is detected by the receiver of the Probe 1 (P1) for measurement, the minute voltage and current for measurement flow from the PSD (power supply) attached to the probe to the ground, and then, through the soil between P1 and P2, enters the Probe 1 (P2). The resistance value is then measured by the principle of voltage drop due to ground resistance. Measure the earth resistance every T seconds up to 1 trillion and store the measured data on the Arduino Server mounted on the main equipment. Stored measurement data can be derived from formulas by Ohm's Law and from inherent resistance (here,). Data obtained in real time will be linked to CDGES programs installed on Main PC, enabling data analysis and real-time monitoring of the ground environment on land. In addition, a three-dimensional display is possible with 3D graph support by identifying seasonal characteristics such as temperature and humidity of land (soils). The limitations of the study will require specific application measures of Test Bed for commercial access to a model that has been developed and operated experimentally.

COMPARATIVE STUDY ON THE DETECTION OF PORPHYROMONAS ENDODONTALIS BY ANAEROBIC CULTURE, IIF AND DNA PROBE METHOD IN INFECTED ROOT CANALS (감염 근관에서 혐기성 배양법과 간접 면역 형광법 및 DNA 프로브법에 의한 Porphyromonas endodontalis의 검출에 관한 비교 연구)

  • Kim, Min-Kyum;Yoon, Soo-Han;Chung, Chong-Pyoung
    • Restorative Dentistry and Endodontics
    • /
    • v.21 no.1
    • /
    • pp.1-18
    • /
    • 1996
  • There are many advantages when using IIF and DNA probe methods over anaerobic culture method in that they are time-and effort-saving, more precise and more sensitive. Furthermore, in IIF and DNA probe methods, the detection is possible only with small amount of bacteria, the quantitative analysis is possible, and the cell viability is not necessary. The purpose of this study is to observe the incidence of P.endodontalis by carrying out anaerobic culture, IIF and colony lift using DNA probe method respectively, and to compare these 3 methods in terms of effectiveness and sensitivity in order to identify the most effective detection method. 30 teeth with at least one clinical symptoms, with single canal, and with pulp necrosis were sampled. For sampling bacteria, access cavity was prepared after disinfecting tooth and its surroundings. Then the paper point was inserted up to the periapical area, leave there for a while, and finally it was placed into PRAS Ringer's sol. and PBS sol. In anaerobic culture method, P.endodontalis was identified by biochemical tests after subculturing black and brown colonies which were produced after 7 days of incubation on BAP and Brucella BAP in anaerobic chamber. To identify P.endodontalis in IIF method, species-specific polyclonal rabbit-antisera of P.endodontalis(ATCC 35406) was reacted with sampled PBS sol. dispensed onto glass slide, and then P.endodontalis was examined by phase contrast microscopy after incubating with Goat anti-rabbit lgG conjugated to Fluorescein isothiocyanate. For colony lift using DNA probe method, membranes were laid over colonies on the surface of BAP and were hybridized with cloned DNA probe of P.endodontalis. The existence of P.endodontalis was then identified by the methods of chemiluminescent detection and color metric detection. Black colony was found in 11 teeth out of 30 teeth and P.endodontalis was detected in 6 teeth (20 %) by anaerobic culture method, 16 teeth (53 %) by IIF method, and 7 teeth (23 %) by DNA probe method. IIF method is significantly better in detecting P.endodontalis than DNA probe method and anaerobic culture method. There was no significant differences between DNA probe method and anaerobic culture method. There was significant correlation between the formation of black colony and the existence of P.endodontalis. The probability of detecting P.endodontalis when black colony being present is 2.89 times higher than when not being present. There was significant relationship between the foul odor of clinical symptoms and P.endodontalis. The sensitivity of existing P.endodontalis when foul odor being present was 93.75 %, while the specificity of not existing P.endodontalis when foul odor not being present was 28.57 %. These results suggested that the probes of P.endodontalis will be used to decide the method and prognosis in endodontic treatments.

  • PDF

Performance Analysis of Access Channel Decoder Implemeted for CDMA2000 1X Smart Antenna Base Station (CDMA2000 1X 스마트 안테나 기지국용으로 구현된 액세스 채널 복조기의 성능 분석)

  • 김성도;현승헌;최승원
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.2A
    • /
    • pp.147-156
    • /
    • 2004
  • This paper presents an implementation and performance analysis of an access channel decoder which exploits a diversity gain due to the independent magnitude of received signals energy at each of antenna elements of a smart antenna BTS (Base-station Transceiver Subsystem) operating in CDMA2000 1X signal environment. Proposed access channel decoder consists of a searcher supporting 4 fingers, Walsh demodulator, and demodulator controller. They have been implemented with 5 of 1 million-gate FPGA's (Field Programmable Gate Array) Altera's APEX EP20K1000EBC652 and TMS320C6203 DSP (digital signal processing). The objective of the proposed access channel decoders is to enhance the data retrieval at co]1-site during the access period, for which the optimal weight vector of the smart antenna BTS is not available. Through experimental tests, we confirmed that the proposed access channel decoder exploitng the diversity technique outperforms the conventional one, which is based on a single antenna channel, in terms of detection probability of access probe, access channel failure probability, and $E_{b/}$ $N_{o}$ in Walsh demodulator.r.r.