• Title/Summary/Keyword: acceptance rates

Search Result 102, Processing Time 0.026 seconds

Development of a method for the determination of 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanone in dust using liquld chromatography tandem mass spectrometry (LC-MS/MS를 이용하여 먼지 속의 NNK (4-(methylnitrosamino)-1-(3-pyridyl)-1-butanone) 정량 분석법 개발)

  • Lee, W.K.;Kang, S.J.;Oh, J.E.;Hwang, S.H.;Lee, D.H.
    • Analytical Science and Technology
    • /
    • v.28 no.1
    • /
    • pp.1-7
    • /
    • 2015
  • 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanone (NNK), a tobacco specific nitrosamine found only in tobacco products. The ability to monitor biomarker concentrations is very important in understanding environmental tobacco smoke (ETS). In this study, an efficient and sensitive method for the analysis of NNK in dust was developed and validated using liquid chromatography tandem mass spectrometry. Dust was collected with filter paper soaked in methanol. The standard solution and dust sample were diluted with 100 mM ammonium acetate and extracted using dichloromethane. Our calibration curves ranged from 25 to $10^4pg/mL$. Excellent linearity was obtained with correlation coefficient values between 0.9996 and 1.0000. The limit of detection (LOD) was 5 pg/mL ($S/N{\geq}3$) and the retention time was 10 min. The limit of quantification (LOQ) was 25 pg/mL, and the acceptance criteria was the rate of 98-103% (80-120% at levels up to $3{\times}LOQ$). The coefficient of variations (CV) was 2.8%. Accuracies determined from dust samples spiked with four different levels of NNK racurves ranged that from 25 to 104 pg/mL. Excellent linearity was obtained between 92.1% and 114%. The precision of the method was acceptable (5% of CV). The recovery rates of the whole analytical procedure at low, medium, and high levels were 105.7-116.5% for NNK. The carry-over effects during LC-MS/MS analysis were not observed for NNK. This manuscript summarizes the scientific evidence on the use of markers to measure ETS.

A Study on News Graphic Design in Social Media (온라인 인포그래픽 뉴스의 커뮤니케이션에 관한 연구)

  • Won, Jongyoun
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.12
    • /
    • pp.57-67
    • /
    • 2019
  • The way people read news is changing, from print to screen. In this study, we aimed to understand the impact of the use of infographics in news on readers. According to a study conducted by Reuters Research Institute at the University of Oxford in 2017, the proportion of online consumers of news is steadily increasing, with over 51 per cent of Americans receiving news via social media. Additionally, newspaper subscription rates are rapidly declining. According to previous studies, the understanding of text information is higher in print media than on screen. Therefore, to compensate for the weaknesses in the understanding of online news, online news media are providing infographic news services to deliver good news. Therefore, this study attempted to understand the impact of using infographics in the news. To this end, three experiments were conducted. The findings from the study indicate that the use of infographics in news has a positive effect on users in terms of the variables measured, including cognitive effect and acceptance of news. As compared with print news, on-screen news was not as effective in terms of comprehension. However, we propose interactive infographics to enhance communication effect along with improved design.

Evaluation of Beam-Matching Accuracy for 8 MV Photon Beam between the Same Model Linear Accelerator (동일 기종 선형가속기간 8 MV 광자선에 대한 빔 매칭 정확도 평가)

  • Kim, Yon-Lae;Chung, Jin-Beom;Kang, Seong-Hee
    • Journal of radiological science and technology
    • /
    • v.43 no.2
    • /
    • pp.105-114
    • /
    • 2020
  • This study aimed to assess of beam-matching accuracy for an 8 MV beam between the same model linear accelerators(Linac) commissioned over two years. Two models were got the customer acceptance procedure(CAP) criteria. For commissioning data for beam-matched linacs, the percentage depth doses(PDDs), beam profiles, output factors, multi-leaf collimator(MLC) leaf transmission factors, and the dosimetric leaf gap(DLG) were compared. In addition, the accuracy of beam matching was verified at phantom and patient levels. At phantom level, the point doses specified in TG-53 and TG-119 were compared to evaluate the accuracy of beam modelling. At patient level, the dose volume histogram(DVH) parameters and the delivery accuracy are evaluated on volumetric modulated arc therapy(VMAT) plan for 40 patients that included 20 lung and 20 brain cases. Ionization depth curve and dose profiles obtained in CAP showed a good level for beam matching between both Linacs. The variations in commissioning beam data, such as PDDs, beam profiles, output factors, TF, and DLG were all less than 1%. For the treatment plans of brain tumor and lung cancer, the average and maximum differences in evaluated DVH parameters for the planning target volume(PTV) and the organs at risk(OARs) were within 0.30% and 1.30%. Furthermore, all gamma passing rates for both beam-matched Linacs were higher than 98% for the 2%/2 mm criteria and 99% for the 2%/3 mm criteria. The overall variations in the beam data, as well as tests at phantom and patient levels remains all within the tolerance (1% difference) of clinical acceptability between beam-matched Linacs. Thus, we found an excellent dosimetric agreement to 8 MV beam characteristics for the same model Linacs.

Air Sampling For Volatile Organics Using an Adsorbent (흡착제를 이용한 휘발성 유기물 채취)

  • ;L.R.Berrafato
    • Journal of Environmental Science International
    • /
    • v.1 no.1
    • /
    • pp.41-46
    • /
    • 1992
  • To perform a long-term ambient sampling study at a residential site, an air sampler was constructed to collect 24-hour integrated air samples suitable for the volatile organic compounds (VOCs) analysis. It includes an esthetically acceptance due to proximity to homes, as fell as providing the required sampling specifications. The VOCs sampler accomodates four 5/8 "stainless steel(SS) traps packed with adsorbent(Tenax) and is capable of four flow rates in the range of 5 to 50 cc/min. Sintered metal filters(10 micrometer) were directly connected to the inlet of the trap adapters. Additional specifications include: 1) constructed of organically inert materials, 2) weatherproof, 3) battery operated, 4) collecting of VOCs at a breathing zone level, and 5) quiet operation with micro diaphragm pumps wrapped by the sponge. The pump/battery system was separated from the sampling shelter. Sound levels measured for this system were below permissible sound levels (NJDEP) at a residential site. The sampler has been successfully operated at both ground level in a residential area and on the roof of a one story elementary school.hool.

  • PDF

Analysis of major indicators of department of dental hygiene in college through the university information disclosure system (대학정보공시를 이용한 치위생과 주요 지표 분석)

  • Lee, Sun-Mi
    • Journal of Korean society of Dental Hygiene
    • /
    • v.22 no.3
    • /
    • pp.153-160
    • /
    • 2022
  • Objectives: This study tried to use information from the university information disclosure system as basic data to understand dental hygiene departments and search for development directions by analyzing major indicators through information disclosure data collection. Methods: Based on the information released from 2019 to 2021, 53 three-year universities with dental hygiene departments nationwide were analyzed based on data from the last three years of university alerts. Results: The indicators that the colleges with dental hygiene departments had higher averages than the overall junior colleges were: rate of levy with enrolled students within the quota, rate of faculty in full service, rate of lectures conducted by faculty in full service, employment rate, and annual scholarships per person. In the dental hygiene departments, acceptance rates of new students were 1.46-30.53 (average 10.24), admission quota was 27-160 (average 70), the number of continuing students was 39-515 (average 209), number of scholarships was 1,368,348.50 won-4,581,073.13 won (average 3,515,647.32 won) and the employment rate ranged from 57.6% to 98.9% (average 82.8%). Conclusions: In order for the departments of dental hygiene to be competitive, it is necessary for colleges to find ways to increase pride in, and satisfaction with their departments. After graduation, if the professional dental hygienist system is established and the legal role as a dental hygienist is expanded, it will be possible to move forward as a competitive department.

The current status of fibromyalgia in Korea: an electronic population health data study in Korea

  • Cheol-Hyeong Lee;Eun Young Lee;Miyoung Yang;Hyung-Sun Won;Yeon-Dong Kim
    • The Korean Journal of Pain
    • /
    • v.36 no.4
    • /
    • pp.458-464
    • /
    • 2023
  • Background: Fibromyalgia (FM) is a complex disorder characterized by widespread chronic pain and tenderness in the muscles, ligaments, and soft tissues. It is a chronic pain condition often accompanied by other symptoms and comorbidities. To effectively manage FM, it is crucial to obtain fundamental epidemiological data pertaining to the target population. Therefore, this study was conducted to elucidate the epidemiological characteristics of FM in the Korean population. Methods: Population-based medical data of 51,276,314 subscribers to the National Health Insurance Service of Korea from 2014 to 2018 were used in this study. Results: The overall incidence of FM ranged from 441 (2014) to 541 (2018) cases per 100,000 person-years, with a higher prevalence observed among female patients compared to male patients. The incidence gradually increased until middle age, followed by a decrease. The highest incidence rates were observed in the fifth decade of life for females and the sixth decade of life for males. When categorizing the affected parts of the body, the shoulder region was observed to be the most frequently affected. A comparison of the drug prescriptions based on medical specialty showed that antidepressants were the most commonly prescribed medications. The management of FM leads to consistent increases in medical expenses, regional disparities, and variations in prescription patterns across different medical specialties. Conclusions: The findings of this study will not only contribute to the understanding of FM characteristics but also provide a vital foundation for efficient management of FM in Korea.

Optimization of Vegetable Rice Porridge Preparation with Israeli Carp Cyprinus carpio (향어(Cyprinus carpio) 함유 야채죽의 제조공정 최적화)

  • Sang In Kang;Ye Youl Kim;Jin-Soo Kim
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.56 no.3
    • /
    • pp.275-283
    • /
    • 2023
  • This study optimized the vegetable rice porridge preparation process with Israeli carp Cyprinus carpio (VRP-IC). The optimum heating period for Israeli carp paste (IC-P) in a retort was 120 min as per yield results. Response surface methodology was performed with IC-P/[rice (glutinous rice: non-glutinous rice=6:4) (Rice, RI)+vegetable (carrot: zucchini=1:1) (vegetable, VE)] (X1) and RI/VE (X2) as independent variables; viscosity (Y1), hardness (Y2), amino nitrogen (Y3), and overall sensory acceptance (Y4) as dependent variables. Optimum rates of IC-P, RI, and VE were 47.37%, 24.49%, and 28.15%, respectively; predicted multiple response optimum values for the dependent variables were 20,150 mPa·s, 2,002.9 N/m2, 193.1 mg/100 g, and a 6.4 score for Y1, Y2, Y3, and Y4, respectively. Under optimum conditions, experimental values for Y1, Y2, Y3, and Y4 were 20,359.8±191.9 mPa·s, 2,015.0±9.6 N/m2, 188.1±4.9 mg/100 g, and a 6.5±0.2 score, respectively, which were not significantly different from the predicted values (P < 0.05). Results of F0 value, viscosity, hardness, volatile odor intensity, and browning suggested that the optimum sterilization period was 25 min. VRP-IC prepared under the optimum conditions was superior to commercial vegetable rice porridges in sensory evaluations.

Current Usage and Proliferation of Library 2.0 from User Viewpoint: Focusing on Folksonomy (이용자관점에서의 도서관 2.0 서비스 활용현황과 활성화 방안 - 폭소노미 서비스를 중심으로 -)

  • Kim, Sungwon;Kim, Jeongwoo
    • Journal of the Korean BIBLIA Society for library and Information Science
    • /
    • v.24 no.2
    • /
    • pp.269-288
    • /
    • 2013
  • The development of IT (information technology) has brought about many types of new services, and the traditional sectors such as libraries and information management fields have actively applied new technology to improve the quality of their services. Many of these newly developed services are described under the term 'Web 2.0', in the sense they are next-generation forms of services, and this coinage is duplicated in the term 'Library 2.0', specifically referring to the library services equipped with Web 2.0 technology. Active acceptance of advanced IT to library services is very important to enhance the value and role of library in this rapidly changing information environment. So far, libraries in Korea and abroad have already been putting a lot of efforts and resources to develop and provide technically advanced services. Despite these efforts, it is found that some of these new services have failed to attract users' attention and interest, resulting in the low rates of usage. This study, therefore, reviews current state of the "Folksonomy" based services provided in Korean college libraries as a type of Library 2.0 services, and assess their usage rates. The result of this evaluation is then used to develop a guideline to improve and mobilize the use of such services.

Analysis of a Comparability Test between LX Detergent Cleaning Solution and OC Detergent Cleaning Solution Using OC Sensor PLEDIA (OC Sensor PLEDIA를 이용한 LX Detergent Cleaning Solution과 OC Detergent Cleaning Solution의 동등성 평가)

  • Cha, Kyung Jae
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.53 no.1
    • /
    • pp.19-31
    • /
    • 2021
  • This study aimed at comparing the performance of imported LX detergent cleaning solution (LX-CS) and the self-manufactured OC cleaning solution (OC-CS), based on functional and quantitative analysis. The functional analysis was carried out using apparent diffusion coefficient (ADC) values. For quantitative analysis, precision, linearity, and carry-over rates were measured with commercial control materials according to the Clinical and Laboratory Standards Institute (CLSI) guidelines. Using OC-Sensor PLEDIA (Eiken Chemical, Japan), the ADC value of all cuvettes satisfied the acceptance criteria. For quantitative analysis, precision was less than 5.0% for the two products, and carry-over rates were less than ±1.00%. The linearity slopes and r2 values were 1.0017 and 0.9982 in the LX-CS, and 0.9924 and 0.9996 in the OC-CS, respectively. The correlation coefficient (r) was found to be 0.9997. Also, the percent difference in correlation with 40 artificial-stool specimens was less than 10% and the p-value was less than 0.1. The result of standard deviation ratio (D: ±1 SD ratio) was similar for both products. In conclusion, the functional and quantitative analyses of the two products were compared and showed similar results. In the future, the self-manufactured OC-CS will be able to provide a much more stable and faster supply than the imported LX-CS.

Efficiency Study of 2D Diode Array Detector for IMRT Quality Assurance (2D 어레이 다이오드 검출기를 통한 IMRT 계산선량의 정확성 평가 및 효용성 연구)

  • Kim, Tae-Ho;Oh, Seung-Jong;Kim, Min-Joo;Jung, Won-Gyun;Chung, Jin-Beom;Kim, Jae-Sung;Kim, Si-Yong;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.22 no.2
    • /
    • pp.61-66
    • /
    • 2011
  • In this study, we evaluated the effect of grid size on dose calculation accuracy using 2 head & neck and 2 prostate IMRT cases and based on this study's findings, we also evaluated the efficiency of a 2D diode array detector for IMRT quality assurance. Dose distributions of four IMRT plan data were calculated at four calculation grid sizes (1.25, 2.5, 5, and 10 mm) and the calculated dose distributions were compared with measured dose distributions using 2D diode array detector. Although there was no obvious difference in pass rate of gamma analysis with 3 mm/3% acceptance criteria for the others except 10 mm grid size, we found that the pass rates of 2.5, 5 and 10 mm grid size were decreased 5%, 20% and 31.53% respectively according to the application of the fine acceptance criteria, 3 mm/3%, 2 mm/2% and 1 mm/1%. The calculation time were about 11.5 min, 4.77 min, 2.95 min, and 11.5 min at 1.25, 2.5, 5, and 10 mm, respectively and as the grid size increased to double, the calculation time decreased about one-half. The grid size effect was observed more clearly in the high gradient area than the low gradient area. In conclusion, 2.5 mm grid size is considered acceptable for most IMRT plans but at least in the high gradient area, 1.25 mm grid size is required to accurately predict the dose distribution. These results are exactly same as the precious studies' results and theory. So we confirmed that 2D array diode detector was suitable for the IMRT QA.