• 제목/요약/키워드: accelerometry

검색결과 15건 처리시간 0.025초

정상보행시 체중심의 수직 가속도 특성 (Characteristics of Vertical Acceleration at Center of Mass of the Body in Normal Gait)

  • 이진복;강성재;김영호
    • 한국전문물리치료학회지
    • /
    • 제9권3호
    • /
    • pp.39-46
    • /
    • 2002
  • In this study, vertical acceleration of center of mass was observed along normal gait phases in 9 healthy male volunteers (aged $25.7{\pm}2.18$). The developed wireless accelerometric device was attached on the intervertebral space between L3 and L4 using a semi-elastic waist belt. A three-dimensional motion analysis system, synchronized with the accelerometry, was used for detecting gait phases. There was no significant correlation between the body weight and the acceleration. The first peak curve covered loading response phase. The second downward peak point was matched accurately with the opposite toe-off. In mid-stance and terminal stance, the acceleration curve highly resembled the vertical ground reaction force curve. There was no significant difference in timing between the final upward peak point and the initial contact. Therefore, the developed accelerometry system would be helpful in determining determine temporal gait pattems in patients with gait disorders.

  • PDF

무구속 수면효율 분석을 위한 스마트폰 기반 움직임패턴 특성분석 (Movement Characteristic Analysis for Unconstrained Sleep Efficiency Analysis Based on the Smartphone)

  • 김도윤;신항식
    • 전기학회논문지
    • /
    • 제63권7호
    • /
    • pp.940-944
    • /
    • 2014
  • In this research, we designed representative motion patterns that possibly occurred in sleep situation and evaluated the feasibility of the smartphone based movement recording technique. For this, we designed 7 motions such as posture change, head movement, arm movement (vertical, horizontal), leg movement and hand movement (flipping, folding). Movement was recorded by using the smartphone and the actimetry device simultaneously for comparing the feasibility of smartphone based recording. As a result of experiment, we found that the smartphone based movement recording well reflects the body movement, however, it shows the limitation in recording the small local movement such as hand motion compared with the reference actimetry device, Actiwatch.

가속도센서를 이용한 편마비성보행 평가 (Evaluation of Hemiplegic Gait Using Accelerometer)

  • 이준석;박수지;신항식
    • 전기학회논문지
    • /
    • 제66권11호
    • /
    • pp.1634-1640
    • /
    • 2017
  • The study aims to distinguish hemiplegic gait and normal gait using simple wearable device and classification algorithm. Thus, we developed a wearable system equipped three axis accelerometer and three axis gyroscope. The developed wearable system was verified by clinical experiment. In experiment, twenty one normal subjects and twenty one patients undergoing stroke treatment were participated. Based on the measured inertial signal, a random forest algorithm was used to classify hemiplegic gait. Four-fold cross validation was applied to ensure the reliability of the results. To select optimal attributes, we applied the forward search algorithm with 10 times of repetition, then selected five most frequently attributes were chosen as a final attribute. The results of this study showed that 95.2% of accuracy in hemiplegic gait and normal gait classification and 77.4% of accuracy in hemiplegic-side and normal gait classification.

Comparison of dominant and nondominant handwriting with the signal of a three-axial accelerometer

  • Kim, Tae-Hoon
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제13권2호
    • /
    • pp.260-266
    • /
    • 2021
  • Handwriting using the dominant and nondominant arms was analyzed in 52 young adults with the aid of a three-axial accelerometer. We measured a signal vector magnitude (SVM) and the percentage of the total signal vector magnitude (%TSVM) for the metacarpophalangeal joint (MCP), radial styloid process (RSP), and lateral epicondyle (LE) of both arms. The SVM for the MCP was lower in the dominant arm than the nondominant arm, whereas that for the RSP was higher. %TVSM was lower for the MCP than for the RSP and LE in the nondominant arm, but higher for the MCP than for the LE in the nondominant arm. These findings suggest that controlling the MCP will improve the quality of handwriting, including when using the nondominant arm.

전후방향의 플랫폼 이동에 대한 동적균형 회복 특성 (Characteristics of Dynamic Postural Control in Anteroposterior Perturbation of a Platform)

  • 태기식;김영호
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 추계학술대회 논문집
    • /
    • pp.1066-1069
    • /
    • 2002
  • Dynamic postural control varies with the environmental context, specific task and intentions of the subject. In this paper, dynamic postural control against forward-backward perturbations of a platform was estimated using tri-axial accelerometers and a force plate. Ten young healthy volunteers stood upright in comfortable condition on the perturbation system which was controlled by an AC servo motor. With anterior-posterior perturbations, movements of ankle, knee and hip Joints were obtained by tri-axial accelerometers. and ground reaction forces with corresponding displacements of the center of pressure(CoP) by the force plate. The result showed that the ankle moved first and the trunk forward, which implies that the mechanism of the dynamic postural control in forward-backward perturbations, occurred in the procedure of the ankle, the knee and the hip. Knee flexion and hip extension in the period of acceleration, constant velocity and deceleration phase is very important fur the balance recovery. These responses depends on the magnitude and timing of the perturbation. From the present study the accelerometry-system appears to be a promising tool for understanding kinematic accelerative In response to a transient platform perturbation. A more through understanding of balance recovery mechanism may aid in designing methods for reducing falls and the resulting injuries.

  • PDF

가속도계 기반의 편마비 환자 보행 평가를 위한 보 검출 (Detection of Steps or Gait Assessment of Hemiplegic Patient Based on Accelerometer)

  • 이효기;김영호;박시운;이경중
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제55권10호
    • /
    • pp.452-457
    • /
    • 2006
  • In this paper, an algorithm to detect steps in hemiplegic patients using a 3-axis accelerometer a紅ached on the trunk was proposed. The proposed algorithm consisted of the signal pre-processing, the step detector, the classification of steps and the calculation of stride time. Two FIR band-pass filters were designed and steps were measured by the combination of filtered signals in the vertical and the anteroposterior directions. In addition, the classification of steps and the calculation of stride time were computed by using the detected steps and lateral signals. For the experiment, fourteen hemiplegic patients were participated and the linear accelerations of the trunk and foot switch signals were measured synchronously. To evaluate the system performance, the detected steps and initial contacts by the foot switch were compared. The average error between the steps and initial contacts was 0.024ms and the difference of the average stride time was 0.01s. Finally, all gait events were detected exactly. Results showed that the accelerometry could use for the gait evaluation in clinical rehabilitation therapies.

보행 시 무릎관절 내번토크에 미치는 후족왯지의 영향 (Effects of a Heel Wedge on the Knee Varus Torque During Walking)

  • 정임숙;김사엽;김영호;정도영;권오윤
    • 대한의용생체공학회:의공학회지
    • /
    • 제25권4호
    • /
    • pp.289-293
    • /
    • 2004
  • 본 연구에서는 경사각도가 다른 내, 외측 후족 왯지를 착용하고 보행하는 동안 삼차원 동작분석시스템과 무선가속도측정시스템을 이용하여 무릎관절의 내번토크와 내외측 방향 가속도를 측정하였다. 내번토크와 외측 가속도는 하중수용기와 전유각기에서 각각 양의 절정값을 나타내었다. 하중수용기에 내측 왯지의 경우 내번토크와 외측 가속도가 맨발에 비하여 증가되었으며, 외측 왯지의 경우 내번토크와 외측 가속도값이 감소하였다. (p<0.05). 이러한 변화는 왯지의 경사각이 커질수록 더욱 뚜렷한 상관성을 보였다(p<0.05). 그러나 전유각기에서는 왯지의 방향과 경사에 따른 무릎의 내번토크와 내외측 가속도의 상관성을 확인할 수 없었다. 본 연구의 견과를 통하여 외측 왯지 사용 시 무릎관절의 내번토크가 감소되어 퇴행성 무릎관절염의 치료에 도움을 줄 수 있다. 또한, 보행 중 무릎관절의 내번토크 대신에 외측방향 가속도를 측정함으로써 간단히 왯지의 효과를 결정할 수 있을 것이다.

본태성 진전증의 임상 및 전기생리학적 분석 (Clinical and Electrophysiologic Analysis of Essential tremor)

  • 유성용;서만욱;정슬기
    • Annals of Clinical Neurophysiology
    • /
    • 제7권1호
    • /
    • pp.7-12
    • /
    • 2005
  • Background: Essential tremor (ET) is a common movement disorder that often causes functional disability. There have been very few investigations about the clinical characteristics of ET in Korea. Therefore, we performed a study showing the clinical features and electrophysiological findings of ET. Methods: We analyzed medical records and accelerometry data of 152 patients (male vs female; 79 vs 73) with ET, who visited the Neurology Clinic of Hospital from 2000 to 2003. Clinical characteristics of ET were summarized including the age of onset, family history, tremor type, body part involved, and associated symptoms. The frequency of tremor was recorded and the spectral analysis of tremor was performed. Results: The age of tremor onset showed bimodal distribution with peaks in the 2nd and 5th decades. Family history was found in 46 patients (30.3%). The patients with the family history presented earlier onset of tremor than patients without the history (mean age of onset, y: 35.2 vs. 49.9, P < 0.001). Tremor appeared most frequently in hands (94%), and followed by head (25%). In head tremor, "no-no" pattern was mainly observed and the head tremor was more frequently observed in female. The frequency of tremor was negatively correlated with age (r=-0.49, P<0.001). Conclusions: The present study indicated some important findings about ET: (1) bimodal distribution for an age of onset, (2) younger age of onset in patients with a family history, (3) decreasing frequency of the tremor according to age, and (4) higher prevalence of head tremor in female patients.

  • PDF

뇌졸중으로 인한 편마비 환자의 보행평가를 위한 체중심 가속도센서 기반의 새로운 보 검출 알고리즘 개발 (Development of a Novel Step Detection Algorithm for Gait Evaluation of Patients with Hemiplegia Based on Trunk Accelerometer)

  • 이효기;황성재;조성필;이동률;유승현;이경중;김영호;정하중
    • 대한의용생체공학회:의공학회지
    • /
    • 제30권3호
    • /
    • pp.213-220
    • /
    • 2009
  • In this study, we have developed a novel step detection algorithm for gait evaluation of patients with hemiplegia based on trunk accelerometry device. For this, we have used a bandpass filter and a least square acceleration (LSA) filter which is characterized by emphasizing the peak or valley point of the acceleration signals for each 3-axis accelerometer signals. To evaluate the algorithm, the detected steps by developed algorithm and real steps by the motion analysis system were compared. As a result, we could obtain the sensitivity of 96.44%, the specificity of 99.94% and the accuracy of 99.90% for the patients' data sets and the sensitivity of 100%, the specificity of 99.93% and the accuracy of 99.93% for the normal data sets. In conclusion, the developed algorithm is useful for the step detection for patients with hemiplegia as well as normal subjects.

The effect of short-term creatine intake on blood lactic acid and muscle fatigue measured by accelerometer-based tremor response to acute resistance exercise

  • Lee, Sinwook;Hong, Gyuseog;Park, Wonil;Lee, Jaeseong;Kim, Nahyun;Park, Hyejoon;Park, Jonghoon
    • 운동영양학회지
    • /
    • 제24권1호
    • /
    • pp.29-36
    • /
    • 2020
  • [Purpose] The purpose of this study was to investigate the effects of short-term creatine intake on muscle fatigue induced by resistance exercise in healthy adolescent men, i.e., lactic acid concentration and wrist and head tremor measured by an accelerometer. [Methods] Twelve healthy adolescent men who had no experience with creatine intake were included. The subjects were randomly assigned to the creatine group and the placebo group, followed by 5 days of creatine and placebo intake, and 5 times of 5 sets of leg press, leg extension, bench press, and arm curl exercises at 70% repetition maximum (RM). The lactic acid concentration before and after exercising, rate of perceived exertion (RPE), and accelerometer-based wrist tremor and head tremor during exercise were measured. Subsequently, after 7 days to allow for creatine washout, the same exercise treatment and measurement were performed in each group after switching drug and placebo between the groups. [Results] The level of lactic acid before and after the acute resistance exercise trial was significantly lower in the creatine group than in the placebo group (P <0.05). The mean RPE during the resistance exercise was significantly lower in the creatine group than in the placebo group (P <0.05). There was no difference between the two groups in the mean wrist tremor during resistance exercise, but the mean head tremor values were significantly lower in the creatine group than in the placebo group in the arm curl, the last event of the exercise trials (P <0.05). [Conclusion] Short-term creatine intake reduces the blood fatigue factor increased by resistance exercise, and is thought to suppress fatigue, especially in the latter half of resistance exercise. Therefore, these findings indicate that short-term creatine intake can have an improved effect on anaerobic exercise performance.