• Title/Summary/Keyword: acceleration analysis

Search Result 2,602, Processing Time 0.027 seconds

Effect of Air Bag and Seat Belt on Driver's Safety (에어백과 안전벨트가 운전자 안전에 미치는 영향에 관한 연구)

  • 유장석;장명순
    • Journal of Korean Society of Transportation
    • /
    • v.21 no.2
    • /
    • pp.7-16
    • /
    • 2003
  • To minimize the death and injury by a collision, the installation of an air bag is recommended as a mandatory practice together with the wearing of the seat belt. By using simulated collision experiments, this research focused on the effect of an air bag and seat belt on the driver safety. The vehicle deceleration characteristics were obtained from impact experiment. LSDYNA, a software program for vehicle collision analysis, and MADYMO. a software program for driver motion after collision, were used for simulated experiment. Four cases such as air bag installed and seat belt wearing (case A), air bag installed but seat belt not wearing (case B), air bag not installed but seat belt wearing (case C), air bag not installed and seat belt not wearing (case D) were analyzed. The impact of acceleration on the injury of driver's head was analyzed by Head Injury Criterion (HIC) as well. It was found that having air bag and wearing seat belt effectively reduced driver's head injury about 52.9% to 70.5% compared with the case of having neither air bag nor wearing seat belt.

Construction of RHEED Apparatus and Study on K, Cs/Si)(111) System (RHEED 장치의 제작과 K, Cs/Si(111)계에 관한 연구)

  • 이경원;안기석;강건아;박종윤;이순보
    • Journal of the Korean Vacuum Society
    • /
    • v.1 no.1
    • /
    • pp.43-49
    • /
    • 1992
  • RHEED apparatus which is one of the systems of surface structure analysis has been constructed.Electron beam is focused by means of magnetic lens, and the beam divergence is about $1{\times}10^{-3}$ rad. The Acceleration voltage of this RHEED apparatus is continuously variable from 0 to 20 kV. K and Cs-adsorbed structureson Si(111)$7{\times}7$ surface at room and high temperatures($200{\times}700^{\circ}C$) have been investigated by RHEED. It is observed that the K and Cs-adsorbed Si(111)surface structures at saturation coverage are Si(111)$7{\tiems}7-K$ and Si(111)$1{\tiems}1-Cs$ at room temperature, respectively. When the specimen temperature was elevated during evaporation,the $3{\times}1$ structure appears in the range of temperature between $300^{\circ}C$ and $550^{\circ}C$, and the $1{\tiems}1$ structure appears above $550^{\circ}C$ in K/Si(111)system. Also, in Cs/Si(111) system the $\sqrt{3}{\times}\sqrt{3}$ structure appears at $300^{\circ}C$, and the $\sqrt{3}{\times}\sqrt{3}+3{\times}1$ structure appears between $350^{\circ}C$ and $400^{\circ}C$.

  • PDF

Assessment of Earthquake Induced Landslide Susceptibility with Variation of Groundwater Level (지하수위 변화에 따른 지진 유발 산사태의 취약섬 분석)

  • Kim, Ji-Seok;Park, Hyuek-Jin;Lee, Jung-Hyun
    • Economic and Environmental Geology
    • /
    • v.44 no.4
    • /
    • pp.289-302
    • /
    • 2011
  • Since the frequency of the earthquake occurrence in Korean peninsular is continuously increasing, the possibility that massive landslides are triggered by earthquake is also growing in Korea. Previously, the landslide is known to be induced by large magnitude earthquake, whose magnitude is larger than 6.0. However, the landslide can be induced by only small magnitude earthquake, especially in the fully saturated soil. Therefore, the susceptibility of landslide caused by small magnitude earthquake in fully saturated soil is analyzed in this study. For that, the topographical and geological characteristics of the site were obtained and managed by GIS software. In the procedure of the study, slope angle, cohesion, friction angle, unit weight of soil were obtained and constructed as a spatial database layer. Combining these data sets in a dynamic model based on Newmark's displacement analysis, the landslide displacements were estimated in each grid cell. In order to check out the possibility of the earthquake induced landslides, the level of the groundwater table is varied from dry to 80% saturated soil. In addition, in order to analyze the effect of the magnitude of earthquake and distance to epicenter, four different earthquakes epicenters were considered in the study area.

Performance Evaluation of Balance Ability Equipment Using VR (VR을 이용한 균형능력 측정장비의 성능평가)

  • Yoon, Sangcheol;An, Howon;Ahn, Taekwon;Choi, Haesung;Lee, Byoungkwon;Seo, Dongkwon;Lee, Kyuhwan;Jung, Sangwoo;Yi, Jaehoon
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.8 no.3
    • /
    • pp.33-41
    • /
    • 2020
  • Purpose : Conventional Balance Measurement can only measure the center of gravity and the shaking movement of the body. As a result, it has the disadvantages of not responding to visual changes and blocking functions of variables. This study was carried out to evaluate the performance of new equipment that measures the balance of the body using changes in body segment and pressure using the acceleration sensor to compensate for the disadvantages of the existing equipment. Methods : To this end, balance ability was measured in 43 healthy male/female adults without orthopedic injuries and nervous system damage in the last 6 months. in a situation where the visual information was restricted by Virtual Reality (VR) gear, all subjects measured and evaluated the balance ability utilizing the new equipment. Balance measurement (Prime Medilab, Korea) and Wii fit (Nintendo, Japan) were used to measure the balance ability of the subjects, and the balance ability test was performed in 4 postures using each device for data acquisition. The test duration for each posture was 30 seconds. For data acquisition, the average value of three experiments measured using each equipment was analyzed, and the statistical test was performed using the independent sample and the corresponding sample t-test, and the significance level was set to α=.05. Results : As a result of measuring the balance ability using individual equipment, blocking visual information using VR gear, the average speed, maximum speed, and moving area of the COP increased equally. It was found that the obtained absolute size of the result in Wii was somewhat larger than that of BM. Conclusion : It is considered that in the future research, it is necessary to measure changes in the body's center of gravity through image analysis, etc., to make clear comparison and evaluation of the usability.

Head motion during cone-beam computed tomography: Analysis of frequency and influence on image quality

  • Moratin, Julius;Berger, Moritz;Ruckschloss, Thomas;Metzger, Karl;Berger, Hannah;Gottsauner, Maximilian;Engel, Michael;Hoffmann, Jurgen;Freudlsperger, Christian;Ristow, Oliver
    • Imaging Science in Dentistry
    • /
    • v.50 no.3
    • /
    • pp.227-236
    • /
    • 2020
  • Purpose: Image artifacts caused by patient motion cause problems in cone-beam computed tomography (CBCT) because they lead to distortion of the 3-dimensional reconstruction. This prospective study was performed to quantify patient movement during CBCT acquisition and its influence on image quality. Materials and Methods: In total, 412 patients receiving CBCT imaging were equipped with a wireless head sensor system that detected inertial, gyroscopic, and magnetometric movements with 6 dimensions of freedom. The type and amplitude of movements during CBCT acquisition were evaluated and image quality was rated in 7 different anatomical regions of interest. For continuous variables, significance was calculated using the Student t-test. A linear regression model was applied to identify associations of the type and extent of motion with image quality scores. Kappa statistics were used to assess intra- and inter-rater agreement. Chi-square testing was used to analyze the impact of age and sex on head movement. Results: All CBCT images were acquired in a 10-month period. In 24% of the investigations, movement was recorded (acceleration: >0.10 [m/s2]; angular velocity: >0.018 [°/s]). In all examined regions of interest, head motion during CBCT acquisition resulted in significant impairment of image quality (P<0.001). Movement in the horizontal and vertical axes was most relevant for image quality (R2>0.7). Conclusion: Relevant head motions during CBCT imaging were frequently detected, leading to image quality loss and potentially impairing diagnosis and therapy planning. The presented data illustrate the need for digital correction algorithms and hardware to minimize motion artefacts in CBCT imaging.

Density-Based Ramp Metering Method Considering Traffic of Freeway and Ramp on ITS (지능형 교통시스템에서 도시 고속도로와 램프의 교통량을 고려한 밀도 기반 램프 미터링 방법)

  • Jeon, Soobin;Jung, Inbum
    • KIISE Transactions on Computing Practices
    • /
    • v.21 no.3
    • /
    • pp.223-238
    • /
    • 2015
  • Ramp metering is the most effective and direct method to control a vehicle entering the freeway. This paper proposed the new density-based ramp metering method. Existing methods that use the flow data had low reliability data and can have various problems. Also, when the ramp metering was operated by freeway congestion, the additional congestion and over-capacity can occur in the ramp. To solve this problem with the existing method, the proposed method used the density and acceleration data of the freeway and considered the ramp status. The developed strategy was tested on Trunk Highway 62 west bound (TH-62 WB) in Minnesota Twin-City and compared with Stratified Zone Metering(SZM), which had been operating in the Twin-City freeway. To constitute the experiment environment, the VISSIM simulator was used. The Traffic Information and Condition Analysis System (TICAS) was developed to control the PTV VISSIM simulator. The experiment condition was set between 2:00 PM and 7:00 PM, Oct 5th, 2014 during severe traffic congestion. The simulation results showed that total travel time was reduced by 20% for SZM. Thus, we solved the problem of ramp congestion and over-capacity.

Lower the Detection Limits of Accelerator Mass Spectrometry

  • John A., Eliades;Song, Jong-Han;Kim, Jun-Gon;Kim, Jae-Yeol;O, Jong-Ju;Kim, Jong-Chan
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.243-244
    • /
    • 2013
  • Over the past 15 years, several groups have incorporated radio-frequency quadrupole (RFQ) based instruments before the accelerator in accelerator mass spectrometry (AMS) systems for ion-gas interactions at low kinetic energy (<40 eV). Most AMS systems arebased on a tandem accelerator, which requires negative ions at injection. Typically, AMS sensitivity abundance ratios for radioactive-to-stable isotope are limited to Xr/Xs >10^-15, and the range of isotopes that can be analyzed is limited because of theneed to produce rather large negative ion beams and the presence of atomic isobaric interferences after stripping. The potential of using low-kinetic energy ion-gas interactions for isobar suppression before the accelerator has been demonstrated for several negative ion isobar systems with a prototype RFQ system incorporated into the AMS system at IsoTrace Laboratory, Canada (Ontario, Toronto). Requisite for any such RFQ system applied to very rare isotope analysis is large transmission of the analyte ion. This requires proper phase-space matching between the RFQ acceptance and the ion beam phase space (e.g. 35 keV, ${\varphi}3mm$, +-35 mrad), and the ability to control the average ion energy during interactions with the gas. A segmented RFQ instrument is currently being designed at Korea Institute for Science and Technology (한국과학기술연구원, KIST). It will consist of: a) an initial static voltage electrode deceleration region, to lower the ion energy from 35 keV down to <40 eV at injection into the first RFQ segment; b) the segmented quadrupole ion-gas interaction region; c) a static voltage electrode re-acceleration region for ion injection into a tandem accelerator. Design considerations and modeling will be discussed. This system should greatly lower the detection limits of the 6 MV AMS system currently being commissioned at KIST. As an example, current detection sensitivity of 41Ca/Ca is limited to the order of 10^-15 while the 41Ca/Ca abundance in modern samples is typically 41Ca/Ca~10^-14 - 10^-15. The major atomic isobaric interference in AMS is 41K. Proof-of-principal work at IsoTrace Lab. has demonstrated that a properly designed system can achieve a relative suppression of KF3-/41CaF3- >4 orders of magnitude while maintaining very high transmission of the 41CaF3- ion. This would lower the 41Ca detection limits of the KIST AMS system to at least 41Ca/Ca~10^-19. As Ca is found in bones and shells, this would potentially allow direct dating of valuable anthropological archives and archives relevant to our understanding of the most pronounced climate change events over the past million years that cannot be directly dated with the presently accessible isotopes.

  • PDF

Dynamic Response of PSC I shape girder being used wide upper flange in Railway Bridge (확장된 상부플랜지 PSC I형 거더교의 동특성 및 동적안정성 분석)

  • Park, Jong-Kwon;Jang, Pan-Ki;Cha, Tae-Gweon;Kim, Chan-Woo;Jang, Il-Young
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.4
    • /
    • pp.125-135
    • /
    • 2015
  • The tendency of more longer span length being required economical in railway bridges is studying about PSC I shaped girder. In this case, it is important to analyze and choose the effective girder section for stiffness of bridge. This study investigates the dynamic properties and safety of PSC I shaped girder being used wide upper flange whose selection based on radii and efficiency factor of flexure for railway bridge in different span type. In addition, 40m PSC Box girder bridge adopted in Honam high speed railway is further analyzed to compare dynamic performance of PSC I shaped girder railway bridge with same span length. Time history response is acquired based on the mode superposition method. Static analysis is also analyzed using standard train load combined with the impact factor. Consequently, the result met limit values in every case including vertical displacement, acceleration and distort.

Development of Gait Distance Measurement System Based on Inertial Measurement Units (관성측정장치를 이용한 보행거리 측정 시스템 개발)

  • Lee, K.H.;Kang, S.I.;Cho, J.S.;Lim, D.H.;Lee, J.S.;Kim, I.Y.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.9 no.2
    • /
    • pp.161-168
    • /
    • 2015
  • In this paper, we present an inertial sensor-based gait distance measurement system using accelerometer, gyroscope, and magnetometer. To minimize offset and gain error of inertial sensors, we performed the calibration using the self-made calibration jig with 9 degrees of freedom. For measuring accurate gait distance, we used gradient descent algorithm to remove gravity error and used analysis of gait pattern to remove drift error. Finally, we measured a gait distance by double-integration of the error-removed acceleration data. To evaluate the performance of our system, we walked 10m in a straight line indoors to observe the improvement of removing error which compared un-calibrated to calibrated data. Also, the gait distance measured by the system was compared to the measurement of the Vicon motion capture system. The evaluation resulted in the improvement of $31.4{\pm}14.38%$(mean${\pm}$S.D.), $78.64{\pm}10.84%$ and $69.71{\pm}26.25%$ for x, y and z axis, respectively when walked in a straight line, and a root mean square error of 0.10m, 0.16m, and 0.12m for x, y and z axis, respectively when compared to the Vicon motion capture system.

  • PDF

Comparison Study of the Impact Response Characteristics of Fixed Cylindrical Offshore Structures Considering Seawater Fluid Region (해수유체영역을 고려한 고정식 실린더형 해양구조물의 충격응답특성 비교연구)

  • Lee, Kangsu;Hong, Keyyong
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.4
    • /
    • pp.489-494
    • /
    • 2015
  • This research focused on minimizing the response of fixed cylindrical offshore structures to a ship impact considering the seawater fluid part. A collision between a ship and offshore structure is generally a complex problem and it is often impractical to perform rigorous finite element analyses to include all the effects and sequences during the collision. The structural behavior of a fixed cylindrical type offshore substructure with a seawater fluid part has a simpler response and small deformation due to the dissipation of impact energy. Upon applying the impact force of a ship to the cylindrical structure, the maximum acceleration, internal energy, and plastic strain are calculated for each load cases using Ls-dyna finite element software. In the maximum cases 2.0 m/s velocity, the response result for the structure was carried out to compare between having a fluid region and no fluid region. Fluid-structure interaction analysis was performed using the ALE method, which make it possible to apply a fluid region on the impact problem. The case of a fixed cylindrical type offshore structure without a seawater fluid part can be a more conservative design.